Two national stalagmite standard (GBW04412, GBW04413) and one international coral standard (RKM4) have been determined by using thermal ionization mass spectrometry (TIMS) method. The values of ( 234 U/ 238 U)...Two national stalagmite standard (GBW04412, GBW04413) and one international coral standard (RKM4) have been determined by using thermal ionization mass spectrometry (TIMS) method. The values of ( 234 U/ 238 U) act , ( 230 Th/ 234 U) act and age are all consistent in error range with the standard values obtained by using α spectrometry.展开更多
Dating techniques including gypsum dissolution in water, iron hydroxide co-precipitation with uranium and thorium and mass spectrometric determination have been investigated in this note. The ages of the gypsum sample...Dating techniques including gypsum dissolution in water, iron hydroxide co-precipitation with uranium and thorium and mass spectrometric determination have been investigated in this note. The ages of the gypsum samples in a CK core from Luobubo lacustrine sediments are in the range of (12.85±0.21) kaBP (4 m distance from the top core) to (153.2 ± 7.2) kaBP (49 m distance from the top core) with the relative errors of ( 1.6%-±4.7%. It indicates that the sedimental environment of the CK core was situated in the middle-late Pleistocene and Holocene periods, corresponding to 1-6 stages of oxygen isotopes in the abyssal sediments and included much information from last inter-glacial to Holocene warm periods.展开更多
A high precision thermal ionization mass spectrometric (HP-TIMS) technique is used to determine 238U,234U,232Th,230Th concentrations and their ratios in whole rocks and minerals separated from Ouaternary Maanshan, Day...A high precision thermal ionization mass spectrometric (HP-TIMS) technique is used to determine 238U,234U,232Th,230Th concentrations and their ratios in whole rocks and minerals separated from Ouaternary Maanshan, Dayingshan and Heikongshan volcanic rocks of Tengchong volcanic field .Yunnan Province, China. The 238U-230Th isochrons are given, yielding four age values (227 ? 20) ka (D-1, Dayingshan), (79.6 ±5.5) ka (D-7, Dayingshan), (21.9 ± 3.0) ka (h-1, Heikongshan), and (7.5 ± 1.0) ka (M-1, Maanshan). The result is not only consistent with but also preciser than those measured by the K-Ar method and the alpha spectrometry U-series method, indicating that the HP-TIMS method is reliable and has high precision. Besides, a procedure of HP-TIMS analysis of young volcanic rocks in China is set up preliminarily.展开更多
The discovery of abrupt paleo\|climate change events and the prediction of environmental changes in the future time have raised an urgent request for high\|resolution paleo\|environmental records. This paper reviews t...The discovery of abrupt paleo\|climate change events and the prediction of environmental changes in the future time have raised an urgent request for high\|resolution paleo\|environmental records. This paper reviews the progress made in chronology and paleo\|environment of stalagmites from karst caves in China and presents some of the results of TIMS\|U\|series dating of stalagmites composed of secondary carbonates, taken from the Dongge, Longquan and Yamen karst caves in Libo County and the Qixing karst cave in Duyun, Guizhou Province, on a MAT\|262 mass spectrometer.展开更多
采用热电离质谱法(thermal ionization mass spectrometry,TIMS)测定铀同位素过程中,质量分馏效应会引起同位素比值测量值偏离真值,一般采用外标校正法对质量分馏效应进行校正,这要求测量过程中标准物质和样品产生一致的质量分馏行为。...采用热电离质谱法(thermal ionization mass spectrometry,TIMS)测定铀同位素过程中,质量分馏效应会引起同位素比值测量值偏离真值,一般采用外标校正法对质量分馏效应进行校正,这要求测量过程中标准物质和样品产生一致的质量分馏行为。因此,除考虑点样的一致性外,测量过程中产生单一的目标离子也非常重要。本研究采用热电离质谱技术考察了铼灯丝氧化对铀同位素测定的影响。将1μg铀以硝酸盐溶液的形式点于铼样品带上,通过监测铀及其氧化物的离子流强度,发现铀主要存在U+和UOx+(x=1或2)的电离形态,并且灯丝表面氧化程度越高,UOx+的产率越高(UOx+/U+可达到1)。实验结果表明,灯丝去气过程过早使灯丝暴露于大气或点样过程中,以及使用较高的样品蒸干电流都会加剧灯丝的氧化。控制灯丝表面氧化或点样过程中加入石墨,可有效降低UOx+的产率,提高目标离子的电离效率。全蒸发测量结果表明,UOx+离子流强度大小对测量结果无明显影响,但通过降低UOx+的离子流强度,可提高测量结果的重现性,进而提高测量过程中分馏行为的一致性。该研究可为提高铀同位素测定过程中样品的利用率提供理论依据。展开更多
文摘Two national stalagmite standard (GBW04412, GBW04413) and one international coral standard (RKM4) have been determined by using thermal ionization mass spectrometry (TIMS) method. The values of ( 234 U/ 238 U) act , ( 230 Th/ 234 U) act and age are all consistent in error range with the standard values obtained by using α spectrometry.
基金This work was supported by the National Key Basis Research Project (Grant No. G19990434) the Innovative Project of the Chinese Academy of Sciences (Grant No. KZCX 1-y 05) and the Resources and Environment Basis Project of the University of Science an
文摘Dating techniques including gypsum dissolution in water, iron hydroxide co-precipitation with uranium and thorium and mass spectrometric determination have been investigated in this note. The ages of the gypsum samples in a CK core from Luobubo lacustrine sediments are in the range of (12.85±0.21) kaBP (4 m distance from the top core) to (153.2 ± 7.2) kaBP (49 m distance from the top core) with the relative errors of ( 1.6%-±4.7%. It indicates that the sedimental environment of the CK core was situated in the middle-late Pleistocene and Holocene periods, corresponding to 1-6 stages of oxygen isotopes in the abyssal sediments and included much information from last inter-glacial to Holocene warm periods.
文摘A high precision thermal ionization mass spectrometric (HP-TIMS) technique is used to determine 238U,234U,232Th,230Th concentrations and their ratios in whole rocks and minerals separated from Ouaternary Maanshan, Dayingshan and Heikongshan volcanic rocks of Tengchong volcanic field .Yunnan Province, China. The 238U-230Th isochrons are given, yielding four age values (227 ? 20) ka (D-1, Dayingshan), (79.6 ±5.5) ka (D-7, Dayingshan), (21.9 ± 3.0) ka (h-1, Heikongshan), and (7.5 ± 1.0) ka (M-1, Maanshan). The result is not only consistent with but also preciser than those measured by the K-Ar method and the alpha spectrometry U-series method, indicating that the HP-TIMS method is reliable and has high precision. Besides, a procedure of HP-TIMS analysis of young volcanic rocks in China is set up preliminarily.
文摘The discovery of abrupt paleo\|climate change events and the prediction of environmental changes in the future time have raised an urgent request for high\|resolution paleo\|environmental records. This paper reviews the progress made in chronology and paleo\|environment of stalagmites from karst caves in China and presents some of the results of TIMS\|U\|series dating of stalagmites composed of secondary carbonates, taken from the Dongge, Longquan and Yamen karst caves in Libo County and the Qixing karst cave in Duyun, Guizhou Province, on a MAT\|262 mass spectrometer.
文摘采用热电离质谱法(thermal ionization mass spectrometry,TIMS)测定铀同位素过程中,质量分馏效应会引起同位素比值测量值偏离真值,一般采用外标校正法对质量分馏效应进行校正,这要求测量过程中标准物质和样品产生一致的质量分馏行为。因此,除考虑点样的一致性外,测量过程中产生单一的目标离子也非常重要。本研究采用热电离质谱技术考察了铼灯丝氧化对铀同位素测定的影响。将1μg铀以硝酸盐溶液的形式点于铼样品带上,通过监测铀及其氧化物的离子流强度,发现铀主要存在U+和UOx+(x=1或2)的电离形态,并且灯丝表面氧化程度越高,UOx+的产率越高(UOx+/U+可达到1)。实验结果表明,灯丝去气过程过早使灯丝暴露于大气或点样过程中,以及使用较高的样品蒸干电流都会加剧灯丝的氧化。控制灯丝表面氧化或点样过程中加入石墨,可有效降低UOx+的产率,提高目标离子的电离效率。全蒸发测量结果表明,UOx+离子流强度大小对测量结果无明显影响,但通过降低UOx+的离子流强度,可提高测量结果的重现性,进而提高测量过程中分馏行为的一致性。该研究可为提高铀同位素测定过程中样品的利用率提供理论依据。