Contaminated or infected patients present a risk of cross-contamination for emergency responders, attending medical personnel and medical facilities as they enter a treatment facility. The controlled conditions of an ...Contaminated or infected patients present a risk of cross-contamination for emergency responders, attending medical personnel and medical facilities as they enter a treatment facility. The controlled conditions of an aerosol test chamber are required to examine factors of contamination, decontamination, and cross-contamination. This study presents the design, construction, and a method for characterizing an aerosol test chamber for a full-sized manikin on a standard North Atlantic Treaty Organization litter. The methodology combined air velocity measurements, aerosol particle counts and size distributions, and computational fluid dynamics modeling to describe the chamber’s performance in three dimensions. This detailed characterization facilitates future experimental design by predicting chamber performance for a variety of patient-focused research.展开更多
Objective To study the agreement between ophthalmologists and community health workers in detecting shallow anterior chamber with oblique flashlight test. Methods Totally 425 subjects were given an eye examination in ...Objective To study the agreement between ophthalmologists and community health workers in detecting shallow anterior chamber with oblique flashlight test. Methods Totally 425 subjects were given an eye examination in a community health center. The anterior chamber depth of each subject was examined by one ophthalmologist and two trained community health workers (one nurse and one non-professional health worker) using oblique flashlight test. Inter-observer agreement was determined using the weighted kappa statistic. Results Among the enrolled subjects,148 (35%) were male and 277 (65%) were female. Good agreement was noted in all the three observers. The comparison between the ophthalmologist and the nurse showed a kappa statistic of 0.42 for both eyes (P<0.001). The kappa statistic was 0.54 and 0.52 for right and left eyes respectively between the ophthalmologist and the non-professional health worker (P<0.001). As for agreement between the nurse and the non-professional health worker,the kappa statistic was 0.49 and 0.38 for right and left eyes,respectively (P<0.001). Conclusion The oblique flashlight test may be used as an applicable tool by trained community health workers for screening of shallow anterior chamber and play a role in blindness prevention in community.展开更多
Volatile organic compounds(VOCs) emitted from three types of carpets used in aircrafts were compared by using headspace and dynamic chamber tests. The headspace samples contained many compounds that were not detected ...Volatile organic compounds(VOCs) emitted from three types of carpets used in aircrafts were compared by using headspace and dynamic chamber tests. The headspace samples contained many compounds that were not detected in the dynamic chamber test; in addition, the dominant VOCs found by these two methods were different. The findings indicate that for highly sorptive materials such as carpets, headspace analysis may give inaccurate indication of actual VOC emissions, and it is necessary to conduct dynamic chamber tests over a certain period of time in order to identify the true emission characteristics. From the dynamic chamber tests, 2-ethyl-1-hexanol was the main VOC emitted from all three carpets. The study also examined the emission characteristics of aircraft carpets. In all experiments, total VOC(TVOC) concentration peaked within a few hours after the start of the experiment and was followed by rapid decay. The emission parameters of TVOC emitted by all three carpets were calculated and the simulated data matched the measured data well.展开更多
In this article,novel emulation strategies for the sectored multiple probe anechoic chamber(SMPAC)are proposed to enable the reliable evaluation of the massive multiple-input multiple-output(MIMO)device operating at b...In this article,novel emulation strategies for the sectored multiple probe anechoic chamber(SMPAC)are proposed to enable the reliable evaluation of the massive multiple-input multiple-output(MIMO)device operating at beamforming mode,which requires a realistic non-stationary channel environment.For the dynamic propagation emulation,an efficient closed-form probe weighting strategy minimizing the power angular spectrum(PAS)emulation errors is derived,substantially reducing the associated computational complexity.On the other hand,a novel probe selection algorithm is proposed to reproduce a more accurate fading environment.Various standard channel models and setup configurations are comprehensively simulated to validate the capacity of the proposed methods.The simulation results show that more competent active probes are selected with the proposed method compared to the conventional algorithms.Furthermore,the derived closedform probe weighting strategy offers identical accuracy to that obtained with complicated numerical optimization.Moreover,a realistic dynamic channel measured in an indoor environment is reconstructed with the developed methodologies,and 95.6%PAS similarity can be achieved with 6 active probes.The satisfactory results demonstrate that the proposed algorithms are suitable for arbitrary channel emulation.展开更多
Current portable power generators are mainly based on internal combustion engine since they present higher values of efficiency comparing to other engines;the main reason why internal combustion engine is not convenie...Current portable power generators are mainly based on internal combustion engine since they present higher values of efficiency comparing to other engines;the main reason why internal combustion engine is not convenient for micro power generation (5 - 30 kW) is because of their heaviness. Micro and ultra micro gas turbine devices, based on a micro compressor and a micro turbine installed on the same shaft, are more suitable for this scope for several reasons. Micro turbine systems have many advantages over reciprocating engine generators, such as higher power density (with respect to size and weight), extremely low emissions and few, or just one, moving part. Those designed with foil bearings and air-cooling operate without oil, coolants or other hazardous materials. Micro turbines also have the advantage of having the majority of their waste heat contained in their relatively high temperature exhaust. Micro turbines offer several potential advantages compared to other technologies for small-scale power generation, including: a small number of moving parts, compact size, lightweight, greater efficiency, lower emissions, lower electricity costs, and opportunities to utilize waste fuels. The object of this study is the experimental tests on a stand-alone gas turbine device with a pre-heated combustion chamber (CC), to validate the fuel consumption reduction, compared to an actual and commercial device, used on air models.展开更多
[目的]气候变化新形势下,进一步筛选适宜西北地区抗寒、抗抽干葡萄砧木品种,可为葡萄免埋土栽培推广提供理论依据和技术支撑。[方法]本文以41Bmgt、Riparia、420Bmgt、101-14、196-17、44-53ma、110R、Rupestris du Lot、SO4、161-490、...[目的]气候变化新形势下,进一步筛选适宜西北地区抗寒、抗抽干葡萄砧木品种,可为葡萄免埋土栽培推广提供理论依据和技术支撑。[方法]本文以41Bmgt、Riparia、420Bmgt、101-14、196-17、44-53ma、110R、Rupestris du Lot、SO4、161-490、1103P、5BB、3309、Leon Millt共14种13年生葡萄砧木为试材,通过测定离体一年生枝条累计失水速率,结合田间调查葡萄砧木存活率和离体一年生枝条抽干率,以此来评价不同葡萄砧木品种抗抽干能力;结合前人研究及砧木品种特性,采用高低温交变试验箱模拟低温的方法,设置4(对照)、-15、-20、-25和-30℃一系列温度梯度水平,测定不同葡萄砧木一年生枝条相对电导率、丙二醛、游离脯氨酸、可溶性糖及可溶性蛋白5个生理生化指标,利用隶属函数法进行综合评价不同葡萄砧木的抗寒性。[结果]不同葡萄砧木的抗抽干能力由强到弱依次为:3309>161-490>196-17>Leon Millt>420Bmgt>44-53ma>Riparia>110R>1103P>SO4>101-14>41Bmgt>5BB>Rupestris du Lot;随着处理温度的降低,不同葡萄砧木枝条的抗寒指标总体呈现上升趋势,但不同品种之间存在差异。根据隶属函数的综合分析,结果显示各葡萄砧木的抗寒性由强到弱依次为:SO4>196-17>Leon Millt>5BB>Riparia>44-53ma>420Bmgt>1103P>3309>110R>Rupestris du Lot>101-14>41Bmgt>161-490。[结论]Riparia、196-17、44-53ma和Leon Millt具有较强的抗抽干能力和抗寒性,可作为我国西北地区免埋土葡萄砧木使用。展开更多
文摘Contaminated or infected patients present a risk of cross-contamination for emergency responders, attending medical personnel and medical facilities as they enter a treatment facility. The controlled conditions of an aerosol test chamber are required to examine factors of contamination, decontamination, and cross-contamination. This study presents the design, construction, and a method for characterizing an aerosol test chamber for a full-sized manikin on a standard North Atlantic Treaty Organization litter. The methodology combined air velocity measurements, aerosol particle counts and size distributions, and computational fluid dynamics modeling to describe the chamber’s performance in three dimensions. This detailed characterization facilitates future experimental design by predicting chamber performance for a variety of patient-focused research.
基金Supported by Tsinghua-Yue-Yuen Medical Sciences Fund (20240000564) and Norwegian Fredskorpset Exchange Program
文摘Objective To study the agreement between ophthalmologists and community health workers in detecting shallow anterior chamber with oblique flashlight test. Methods Totally 425 subjects were given an eye examination in a community health center. The anterior chamber depth of each subject was examined by one ophthalmologist and two trained community health workers (one nurse and one non-professional health worker) using oblique flashlight test. Inter-observer agreement was determined using the weighted kappa statistic. Results Among the enrolled subjects,148 (35%) were male and 277 (65%) were female. Good agreement was noted in all the three observers. The comparison between the ophthalmologist and the nurse showed a kappa statistic of 0.42 for both eyes (P<0.001). The kappa statistic was 0.54 and 0.52 for right and left eyes respectively between the ophthalmologist and the non-professional health worker (P<0.001). As for agreement between the nurse and the non-professional health worker,the kappa statistic was 0.49 and 0.38 for right and left eyes,respectively (P<0.001). Conclusion The oblique flashlight test may be used as an applicable tool by trained community health workers for screening of shallow anterior chamber and play a role in blindness prevention in community.
基金Funded by the National Basic Research Program of China(973 Program) under Grant No.2012CB720100
文摘Volatile organic compounds(VOCs) emitted from three types of carpets used in aircrafts were compared by using headspace and dynamic chamber tests. The headspace samples contained many compounds that were not detected in the dynamic chamber test; in addition, the dominant VOCs found by these two methods were different. The findings indicate that for highly sorptive materials such as carpets, headspace analysis may give inaccurate indication of actual VOC emissions, and it is necessary to conduct dynamic chamber tests over a certain period of time in order to identify the true emission characteristics. From the dynamic chamber tests, 2-ethyl-1-hexanol was the main VOC emitted from all three carpets. The study also examined the emission characteristics of aircraft carpets. In all experiments, total VOC(TVOC) concentration peaked within a few hours after the start of the experiment and was followed by rapid decay. The emission parameters of TVOC emitted by all three carpets were calculated and the simulated data matched the measured data well.
基金supported by National Natural Science Foundation of China(No.62090015,No.61821001)BUPT Excellent Ph.D.Students Foundation under Grant(CX2021216)。
文摘In this article,novel emulation strategies for the sectored multiple probe anechoic chamber(SMPAC)are proposed to enable the reliable evaluation of the massive multiple-input multiple-output(MIMO)device operating at beamforming mode,which requires a realistic non-stationary channel environment.For the dynamic propagation emulation,an efficient closed-form probe weighting strategy minimizing the power angular spectrum(PAS)emulation errors is derived,substantially reducing the associated computational complexity.On the other hand,a novel probe selection algorithm is proposed to reproduce a more accurate fading environment.Various standard channel models and setup configurations are comprehensively simulated to validate the capacity of the proposed methods.The simulation results show that more competent active probes are selected with the proposed method compared to the conventional algorithms.Furthermore,the derived closedform probe weighting strategy offers identical accuracy to that obtained with complicated numerical optimization.Moreover,a realistic dynamic channel measured in an indoor environment is reconstructed with the developed methodologies,and 95.6%PAS similarity can be achieved with 6 active probes.The satisfactory results demonstrate that the proposed algorithms are suitable for arbitrary channel emulation.
文摘Current portable power generators are mainly based on internal combustion engine since they present higher values of efficiency comparing to other engines;the main reason why internal combustion engine is not convenient for micro power generation (5 - 30 kW) is because of their heaviness. Micro and ultra micro gas turbine devices, based on a micro compressor and a micro turbine installed on the same shaft, are more suitable for this scope for several reasons. Micro turbine systems have many advantages over reciprocating engine generators, such as higher power density (with respect to size and weight), extremely low emissions and few, or just one, moving part. Those designed with foil bearings and air-cooling operate without oil, coolants or other hazardous materials. Micro turbines also have the advantage of having the majority of their waste heat contained in their relatively high temperature exhaust. Micro turbines offer several potential advantages compared to other technologies for small-scale power generation, including: a small number of moving parts, compact size, lightweight, greater efficiency, lower emissions, lower electricity costs, and opportunities to utilize waste fuels. The object of this study is the experimental tests on a stand-alone gas turbine device with a pre-heated combustion chamber (CC), to validate the fuel consumption reduction, compared to an actual and commercial device, used on air models.
文摘[目的]气候变化新形势下,进一步筛选适宜西北地区抗寒、抗抽干葡萄砧木品种,可为葡萄免埋土栽培推广提供理论依据和技术支撑。[方法]本文以41Bmgt、Riparia、420Bmgt、101-14、196-17、44-53ma、110R、Rupestris du Lot、SO4、161-490、1103P、5BB、3309、Leon Millt共14种13年生葡萄砧木为试材,通过测定离体一年生枝条累计失水速率,结合田间调查葡萄砧木存活率和离体一年生枝条抽干率,以此来评价不同葡萄砧木品种抗抽干能力;结合前人研究及砧木品种特性,采用高低温交变试验箱模拟低温的方法,设置4(对照)、-15、-20、-25和-30℃一系列温度梯度水平,测定不同葡萄砧木一年生枝条相对电导率、丙二醛、游离脯氨酸、可溶性糖及可溶性蛋白5个生理生化指标,利用隶属函数法进行综合评价不同葡萄砧木的抗寒性。[结果]不同葡萄砧木的抗抽干能力由强到弱依次为:3309>161-490>196-17>Leon Millt>420Bmgt>44-53ma>Riparia>110R>1103P>SO4>101-14>41Bmgt>5BB>Rupestris du Lot;随着处理温度的降低,不同葡萄砧木枝条的抗寒指标总体呈现上升趋势,但不同品种之间存在差异。根据隶属函数的综合分析,结果显示各葡萄砧木的抗寒性由强到弱依次为:SO4>196-17>Leon Millt>5BB>Riparia>44-53ma>420Bmgt>1103P>3309>110R>Rupestris du Lot>101-14>41Bmgt>161-490。[结论]Riparia、196-17、44-53ma和Leon Millt具有较强的抗抽干能力和抗寒性,可作为我国西北地区免埋土葡萄砧木使用。