A numerical study of a standing-wave thermoacoustic engine is presented. The aim of this work is to study the effect of increasing the heat exchangers length on the acoustic power. The analysis of the flow and the pre...A numerical study of a standing-wave thermoacoustic engine is presented. The aim of this work is to study the effect of increasing the heat exchangers length on the acoustic power. The analysis of the flow and the prediction of the heat transfer are performed by solving the non linear unsteady Navier-Stocks equations using the finite volume method implemented in -ANSYS CFX- CFD code. The results show an increase in the limit cycle acoustic pressure and power as well as the specific work per cycle with the increase of heat exchangers length.展开更多
Pressure ratio is one of the important parameters for evaluating a thermoacoustic heat en- gine. A so-called acoustical pump, which is capable of significantly increasing pressure ratio of a ther- moacoustic heat engi...Pressure ratio is one of the important parameters for evaluating a thermoacoustic heat en- gine. A so-called acoustical pump, which is capable of significantly increasing pressure ratio of a ther- moacoustic heat engine, is proposed. Its operating principle is given. Also, a verification experiment is done with nitrogen gas in the energy-focused ther- moacoustic heat engine, showing that the pressure ratio increased from 1.25 to 1.47.展开更多
An acoustic pressure amplifier (APA) is capable of improving the match between a thermoacoustic engine and a load by elevating pressure ratio and acoustic power output. A standing-wave thermoacoustic engine driving a ...An acoustic pressure amplifier (APA) is capable of improving the match between a thermoacoustic engine and a load by elevating pressure ratio and acoustic power output. A standing-wave thermoacoustic engine driving a resistance- and-compliance (RC) load through an APA was simulated with linear thermoacoustics to study the impact of load impedance on the performance of the thermoacoustic system. Based on the simulation results, analysis focuses on the distribution of pressure amplitude and velocity amplitude in APA with an RC load of diverse acoustic resistances and compliance impedances. Variation of operating parameters, including pressure ratio, acoustic power, hot end temperature of stack, etc., versus impedance of the RC load is presented and analyzed according to the abovementioned distribution. A verifying experiment has been performed, which indicates that the simulation can roughly predict the system operation in the fundamental-frequency mode.展开更多
文摘A numerical study of a standing-wave thermoacoustic engine is presented. The aim of this work is to study the effect of increasing the heat exchangers length on the acoustic power. The analysis of the flow and the prediction of the heat transfer are performed by solving the non linear unsteady Navier-Stocks equations using the finite volume method implemented in -ANSYS CFX- CFD code. The results show an increase in the limit cycle acoustic pressure and power as well as the specific work per cycle with the increase of heat exchangers length.
基金supported by the Chinese Academy of Sciences(Grant No.KJCX2-SW12-12-0)National Natural Science Foundation of China(Grant No 50536040).
文摘Pressure ratio is one of the important parameters for evaluating a thermoacoustic heat en- gine. A so-called acoustical pump, which is capable of significantly increasing pressure ratio of a ther- moacoustic heat engine, is proposed. Its operating principle is given. Also, a verification experiment is done with nitrogen gas in the energy-focused ther- moacoustic heat engine, showing that the pressure ratio increased from 1.25 to 1.47.
基金Project supported by the National Natural Sciences Foundation of China (No. 50536040)the University Doctoral Subject Special Foundation of China (No. 20050335047)+1 种基金the Postdoctoral Science Foundation of Zhejiang Province (No. 2006-bsh-21)the Natural Science Foundation of Zhejiang Province (No. Y107229), China
文摘An acoustic pressure amplifier (APA) is capable of improving the match between a thermoacoustic engine and a load by elevating pressure ratio and acoustic power output. A standing-wave thermoacoustic engine driving a resistance- and-compliance (RC) load through an APA was simulated with linear thermoacoustics to study the impact of load impedance on the performance of the thermoacoustic system. Based on the simulation results, analysis focuses on the distribution of pressure amplitude and velocity amplitude in APA with an RC load of diverse acoustic resistances and compliance impedances. Variation of operating parameters, including pressure ratio, acoustic power, hot end temperature of stack, etc., versus impedance of the RC load is presented and analyzed according to the abovementioned distribution. A verifying experiment has been performed, which indicates that the simulation can roughly predict the system operation in the fundamental-frequency mode.