Introduction THick Gas Electron Multiplier(THGEM)is considered in many UV photon detector applications.It has the capability of detecting single photon and imaging with high sensitivity.Operating parameters such as ch...Introduction THick Gas Electron Multiplier(THGEM)is considered in many UV photon detector applications.It has the capability of detecting single photon and imaging with high sensitivity.Operating parameters such as choice of gas mixture,pressure,drift field,drift gap,multiplication voltage,induction field and induction gap play an important role in deciding the spatial resolution of the detector.Detailed simulation study enables to optimize the above-mentioned parameters for a given THGEM-based imaging detector and hence to achieve improved performance for the same.Materials and methods Simulation,using ANSYS and Garfield++,starts with the release of primary electrons at random coordinates on the photocathode plane.They are tracked as they pass through the drift gap and THGEM hole till the electron cloud reaches anode plane.Distribution of electron cloud on the anode plane along X and Y axis is plotted in histogram and fitted with Gaussian function to determine spatial resolution.Ar/CO_(2)(70:30)mixture,which shows higher ETE and lower transverse diffusion,is chosen for this simulation study.Conclusion Transverse diffusion has a major impact on both ETE and the spatial resolution.Lower transverse diffusion coefficient is always desired for having better resolution as well as for ETE.It is found from the simulation study that higher gas pressure,lower drift field and induction field,smaller drift and induction gap can provide optimum detection efficiency with the best spatial resolution.The simulation method proposed here can also be extended to X-ray imaging detectors.展开更多
An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm...An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8 keV X-rays.展开更多
文摘Introduction THick Gas Electron Multiplier(THGEM)is considered in many UV photon detector applications.It has the capability of detecting single photon and imaging with high sensitivity.Operating parameters such as choice of gas mixture,pressure,drift field,drift gap,multiplication voltage,induction field and induction gap play an important role in deciding the spatial resolution of the detector.Detailed simulation study enables to optimize the above-mentioned parameters for a given THGEM-based imaging detector and hence to achieve improved performance for the same.Materials and methods Simulation,using ANSYS and Garfield++,starts with the release of primary electrons at random coordinates on the photocathode plane.They are tracked as they pass through the drift gap and THGEM hole till the electron cloud reaches anode plane.Distribution of electron cloud on the anode plane along X and Y axis is plotted in histogram and fitted with Gaussian function to determine spatial resolution.Ar/CO_(2)(70:30)mixture,which shows higher ETE and lower transverse diffusion,is chosen for this simulation study.Conclusion Transverse diffusion has a major impact on both ETE and the spatial resolution.Lower transverse diffusion coefficient is always desired for having better resolution as well as for ETE.It is found from the simulation study that higher gas pressure,lower drift field and induction field,smaller drift and induction gap can provide optimum detection efficiency with the best spatial resolution.The simulation method proposed here can also be extended to X-ray imaging detectors.
基金Supported by National Natural Science Foundation of China (10575101)
文摘An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8 keV X-rays.