A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined b...A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.展开更多
A new method for determination of Cu(Ⅱ) by DDCT chelating resin preconcentration and thin layer resin phase spectrophotometry was developed. The method has a high sensitivity (ε455= 3.6×10^5L/mol·cm), ...A new method for determination of Cu(Ⅱ) by DDCT chelating resin preconcentration and thin layer resin phase spectrophotometry was developed. The method has a high sensitivity (ε455= 3.6×10^5L/mol·cm), which is 33 times higher than that of liquid phase spectrophotometry. It has a good selectivity (most coexisting ions could not influence determination) and an ideal precision [30μg Cu(Ⅱ), n=6, RSD= l.67%]. The content of Cu(Ⅱ) in water, high purity rare earth and its oxide was determined. The detection limit of Cu(Ⅱ) is 5.3μg/L , and the linear range is 0-7.2μg/ml. The result is satisfactory.展开更多
A method to determine Fe(Ⅲ) by thin layer resin phase spectrophotometry has been developed in this paper. The colored complex formed by Fe(Ⅲ) and 1,2-benzendiol is concentrated on the 717^# resin, then Fe(Ⅲ) ...A method to determine Fe(Ⅲ) by thin layer resin phase spectrophotometry has been developed in this paper. The colored complex formed by Fe(Ⅲ) and 1,2-benzendiol is concentrated on the 717^# resin, then Fe(Ⅲ) can be determined directly by making thin layer. The method is sensitive with a apparent molar absorption of 4.8×10^4L/mol.cm, which is 16 times higher than that of liquid phase spectrophotornetry, most coexisting ions do not influence the determination. The detection limit for Fe(Ⅲ) is 1.47μg/L with the precision of 3.3% [n=6, 7μg/50mL Fe(Ⅲ)]. The calibration curve is linear in the range of 0-25μg/50mL. The preposed method was applied to the determination of Fe(Ⅲ) in water sample with satisfactory results.展开更多
文摘A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.
文摘A new method for determination of Cu(Ⅱ) by DDCT chelating resin preconcentration and thin layer resin phase spectrophotometry was developed. The method has a high sensitivity (ε455= 3.6×10^5L/mol·cm), which is 33 times higher than that of liquid phase spectrophotometry. It has a good selectivity (most coexisting ions could not influence determination) and an ideal precision [30μg Cu(Ⅱ), n=6, RSD= l.67%]. The content of Cu(Ⅱ) in water, high purity rare earth and its oxide was determined. The detection limit of Cu(Ⅱ) is 5.3μg/L , and the linear range is 0-7.2μg/ml. The result is satisfactory.
基金Advanced Fund Item of Jiangsu University (07KJB610021)
文摘A method to determine Fe(Ⅲ) by thin layer resin phase spectrophotometry has been developed in this paper. The colored complex formed by Fe(Ⅲ) and 1,2-benzendiol is concentrated on the 717^# resin, then Fe(Ⅲ) can be determined directly by making thin layer. The method is sensitive with a apparent molar absorption of 4.8×10^4L/mol.cm, which is 16 times higher than that of liquid phase spectrophotornetry, most coexisting ions do not influence the determination. The detection limit for Fe(Ⅲ) is 1.47μg/L with the precision of 3.3% [n=6, 7μg/50mL Fe(Ⅲ)]. The calibration curve is linear in the range of 0-25μg/50mL. The preposed method was applied to the determination of Fe(Ⅲ) in water sample with satisfactory results.