期刊文献+
共找到1,774篇文章
< 1 2 89 >
每页显示 20 50 100
Experimental Behavior of Recycled Aggregate Concrete Filled Steel Tubular Columns
1
作者 Thirumalai R Suresh Babu S 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第6期1414-1417,共4页
During the modernization or rehabilitation activity,the demolished structural waste causes large soil pollution and unavailability of natural aggregate is the big concern for the construction industry.Therefore,this m... During the modernization or rehabilitation activity,the demolished structural waste causes large soil pollution and unavailability of natural aggregate is the big concern for the construction industry.Therefore,this manuscript deals with the Composite Steel Circular Column(CSCC)with Recycled Aggregate concrete(RAC)as infill is partly used,with the replacement of 25%and 50%in M30 grade of Concrete.And internal reinforcement steel is fully replaced by rolled steel tubes(circular and square)with varied thickness,ISA-unequal angle.Around 14 specimens are cast and examined under axial load for analysis of the deflection characteristics,the load-bearing capacity along with its buckling behavior.The experimental values are estimated through LVDT(linear variable differential transducer)at 3-phase.The curve of load-deflection is drawn with the load pattern.From the date interpretation,it is found column made of 50%-RAC has more than 25%-RAC. 展开更多
关键词 composite steel circular column(CSCC) recycled aggregate concrete(RAC) ISAinternational standard angle LVDT(linear variable differential transducer)
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
2
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) column replacement percentage cyclic loading seismicperformance
下载PDF
Damage assessment for seismic response of recycled concrete filled steel tube columns 被引量:4
3
作者 Huang Yijie Xiao Jianzhuang Shen Luming 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期607-616,共10页
A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the eff... A model for evaluating structural damage of recycled aggregate concrete filled steel tube (RCFST) columns under seismic effects is proposed in this paper. The proposed model takes the lateral deformation and the effect of repeated cyclic loading into account. Available test results were collected and utilized to calibrate the parameters of the proposed model. A seismic test for six RCFST columns was also performed to validate the proposed damage assessment model. The main test parameters were the recycled coarse aggregate (RCA) replacement percentage and the bond-slip property. The test results indicated that the seismic performance of the RCFST member depends on the RCA contents and their damage index increases as the RCA replacement percentage increases. It is also indicated that the damage degree of RCFST changes with the variation of the RCA replacement percentage. Finally, comparisons between the RCA contents, lateral deformation ratio and damage degree were implemented. It is suggested that an improvement procedure should be implemented in order to compensate for the performance difference between the RCFST and normal concrete filled steel tubes (CFST). 展开更多
关键词 recycled aggregate concrete (RAC) recycled concrete filled steel tube (RCFST) column seismicperformance damage assessment model (DAM)
下载PDF
Seismic behavior of large-scale FRP–recycled aggregate concrete–steel columns with shear connectors 被引量:2
4
作者 Zeng Lan Li Lijuan +1 位作者 Yang Xianqian Liu Feng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2019年第4期823-844,共22页
The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggr... The application of fi ber-reinforced polymer (FRP) composites for the development of high-performance composite structural systems has received signifi cant recent research attention. A composite of FRP–recycled aggregate concrete (RAC)–steel column (FRSC), consisting of an outer FRP tube, an inner steel tube and annular RAC fi lled between two tubes, is proposed herein to facilitate green disposal of demolished concrete and to improve the ductility of concrete columns for earthquake resistance. To better understand the seismic behavior of FRSCs, quasi-static tests of large-scale basalt FRSCs with shear connectors were conducted. The infl uence of the recycled coarse aggregate (RCA) replacement percentage, shear connectors and axial loading method on the lateral load and deformation capacity, energy dissipation and cumulative damage were analyzed to evaluate the seismic behavior of FRSCs. The test results show that FRSCs have good seismic behavior, which was evidenced by high lateral loads, excellent ductility and energy dissipation capacity, indicating RAC is applicable in FRSCs. Shear connectors can signifi cantly postpone the steel buckling and increase the lateral loads of FRSCs, but weaken the deformation capacity and energy dissipation performance. 展开更多
关键词 recycled AGGREGATE concrete (RAC) fi ber-reinforced polymer (FRP) FRP–RAC–steel column (FRSC) shear connector seismic behavior
下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
5
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
下载PDF
Behavior of High Strength Concrete Filled Square Steel Tube Stub Columns with Inner CFRP Tube Under Biaxial Eccentric Compression 被引量:1
6
作者 Zhijian Yang Guochang Li +1 位作者 Yan Lang Zengmei Qiu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第4期273-290,共18页
This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of compo... This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper. 展开更多
关键词 CFRP tube concrete-filled square steel tube high strength concrete bi-axial bending stub column
下载PDF
Three-dimensional nonlinear analysis of creep in concrete filled steel tube columns 被引量:1
7
作者 程晓东 李广宇 叶贵如 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期826-835,共10页
This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. Th... This paper proposes a based on 3D-VLE (three-dimensional nonlinear viscoelastic theory) three-parameters viscoelastic model for studying the time-dependent behaviour of concrete filled steel tube (CFT) columns. The method of 3D-VLE was developed to analyze the effects of concrete creep behavior on CFT structures. After the evaluation of the parameters in the proposed creep model, experimental measurements of two prestressed reinforced concrete beams were used to investigate the creep phenomenon of three CFT columns under long-term axial and eccentric load was investigated. The experimentally obtained time-dependent creep behaviour accorded well with the cu~'es obtained from the proposed method. Many factors (such as ratio of long-term load to strength, slenderness ratio, steel ratio, and eccentricity ratio) were considered to obtain the regularity of influence of concrete creep on CFT structures. The analytical results can be consulted in the engineering practice and design. 展开更多
关键词 Three-dimensional virtual laminated element (3D-VLE) Creep analysis Three-dimensional viscoelastic theory Three-parameters viscoelastic model concrete filled steel tube columns
下载PDF
Performance Investigation of Square Concrete-filled Steel Tube Columns
8
作者 陈兵 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第4期730-736,共7页
The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying... The behaviour of square concrete-filled steel tube columns under concentrical loading was studied. More than one hundred specimens were tested to investigate the effects of thickness of steel tube on the load carrying capacity of the concrete-filled tubular columns (CFTs). The effect of the grade of concrete and content of expansive agent were also investigated. The effect of these parameters on the confinement of the concrete core was studied as well. From the experimental study it was found that for both CFTs with different strength grade concrete core, the ultimate load carrying capacity increases with the increase in percentage of expansive agent up to 20% but it again decreases at 25% of expansive agent content. It was also shown that the failure mode of CFTs depends on the strength grade of concrete core. 展开更多
关键词 concrete filled steel tubes concrete columns ultimate capacity expansive agent
下载PDF
Experimental and Numerical Studies on Sea Sand Concrete Filled Stainless Steel Tube with Inner FRP Tube Subjected to Axial Compression
9
作者 ZENG Lan YU Wen-lan +2 位作者 MO Zi-yong HUANG Shi-qing YUAN Hong 《China Ocean Engineering》 SCIE EI CSCD 2023年第2期272-287,共16页
Since fibre-reinforced polymer(FRP) and stainless steel(SS) offer advantages of corrosion resistance and hybrid confinement, this study proposed a new type of composite column: sea sand concrete(SSC)-filled SS tubular... Since fibre-reinforced polymer(FRP) and stainless steel(SS) offer advantages of corrosion resistance and hybrid confinement, this study proposed a new type of composite column: sea sand concrete(SSC)-filled SS tubular columns with an inner FRP tube(CFSTFs) to help exploit abundant ocean resources in marine engineering. To study compressive behaviours of these novel members, eight CFSTFs and two SSC-filled SS tubular columns(CFSTs)were tested under axial compression. Their axial load-displacement curves, axial load-strain curves in SS or FRP tubes were obtained, and influences of key test parameters(the existence of glass FRP(GFRP) tubes, steel tube shapes, and GFRP tube thicknesses and diameters) were discussed. Further, specimen failure mechanism was analyzed employing the finite element method using ABAQUS software. Test results confirmed the excellent ductility and load-bearing capacity of CFSTFs. The existence of GFRP tubes inside can postpone SS tube buckling, and the content of inner FRP tubes, particularly increasing diameters, was found to improve compressive behaviours. GFRP contents helped develop the second elastic-plastic stage of the load-displacement curves. Furthermore, the bearing capacity of CFSTFs with a circular cross-section was approximately 26% higher than that with a square cross-section, and this difference narrowed with the increase in GFRP ratios. 展开更多
关键词 sea-sand concrete(SSC) confined concrete column fibre-reinforced polymer(FRP)tube stainless steel tube axial compression
下载PDF
Experimental study on the seismic behavior of high strength concrete fi lled double-tube columns 被引量:13
10
作者 Qian Jiaru Li Ningbo +1 位作者 Ji Xiaodong Zhao Zuozhou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期47-57,共11页
To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column sp... To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1. 展开更多
关键词 high strength concrete fi lled double-tube(CFDT)column seismic behavior area ratio of the square steel tube width-to-thickness ratio of the square steel tube axial force ratio quasi-static test
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
11
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 columns concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
12
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Seismic behavior of thin-walled circular and stiffened square steel tubed-reinforced-concrete columns 被引量:3
13
作者 GAN Dan ZHOU XuHong +1 位作者 LIU JiePeng LI Jiang 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2019年第3期511-520,共10页
Steel tubed-reinforced-concrete(TRC) columns have been gradually used in the construction of high-rise buildings recently because of their high axial load-carrying capacities and excellent seismic behavior. Existing s... Steel tubed-reinforced-concrete(TRC) columns have been gradually used in the construction of high-rise buildings recently because of their high axial load-carrying capacities and excellent seismic behavior. Existing studies about their seismic behavior were focused on columns with relatively thick tubes, i.e., diameter-to-thickness/width-to-thickness(D/t) ratios were below 100,while little is known about thin-walled TRC columns, especially for square TRC columns. Considering the infilled concrete of square TRC columns is non-uniformly and non-effectively confined, accordingly, stiffened square TRC columns are usually adopted in practice. Thus, two thin-walled circular TRC columns(D/t=120) and two stiffened square ones with diagonal stiffeners in plastic hinge regions(D/t=106) were tested under a constant axial compression combined with cyclic lateral loading.Both the circular and stiffened square TRC columns had the same cross sectional area, tube thickness, reinforcing bar ratio and column height. Flexural failure occurred for all the four specimens. Test results showed the strengths of the stiffened square TRC columns were a little higher in comparison to their circular counterparts; the ductility and energy dissipation capacities were excellent for both the stiffened and circular TRC columns, indicating very good confinement was gained from the yielded steel tubes of the plastic hinge regions at the peak loads. And shear stresses(35–90 MPa) in the sheared plates showed their moderate contribution of carrying lateral loads. Finally, cross sectional capacity analysis results demonstrated the method for TRC columns is acceptable for the stiffened square TRC columns. 展开更多
关键词 steel tubed-reinforced-concrete column concrete filled steel tube composite column cyclic behavior steel JACKET
原文传递
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
14
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Behaviors of recycled aggregate concrete-filled steel tubular columns under eccentric loadings 被引量:1
15
作者 Vivian W.Y.TAM Jianzhuang XIAO +1 位作者 Sheng LIU Zixuan CHEN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2019年第3期628-639,共12页
The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in t... The paper investigates the behaviors of recycled aggregate concrete-filled steel tubular(RACFST)columns under eccentric loadings with the incorporation of expansive agents.A total of 16 RACFST columns were tested in this study.The main parameters varied in this study are recycled coarse aggregate replacement percentages(0%,30%,50%,70%,and 100%),expansive agent dosages(0%,8%,and 15%)and an eccentric distance of compressive load from the center of the column(0 and 40 mm).Experimental results showed that the ultimate stresses of RACFST columns decreased with increasing recycled coarse aggregate replacement percentages but appropriate expansive agent dosages can reduce the decrement;the incorporation of expansive agent decreased the ultimate stresses of RACFST columns but an appropriate dosage can increase the deformation ability.The recycled coarse aggregate replacement percentages have limited influence on the ultimate stresses of the RACFST columns and has more effect than that of the normal aggregate concretesteel tubular columns. 展开更多
关键词 concrete filled steel tubeS recycled AGGREGATE concrete columns expansive agent ECCENTRIC load
原文传递
Axial compression tests and numerical simulation of steel reinforced recycled concrete short columns confined by carbon fiber reinforced plastics strips 被引量:1
16
作者 Hui MA Fangda LIU +2 位作者 Yanan WU Xin A Yanli ZHAO 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第7期817-842,共26页
To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated ... To research the axial compression behavior of steel reinforced recycled concrete(SRRC)short columns confined by carbon fiber reinforced plastics(CFRP)strips,nine scaled specimens of SRRC short columns were fabricated and tested under axial compression loading.Subsequently,the failure process and failure modes were observed,and load-displacement curves as well as the strain of various materials were analyzed.The effects on the substitution percentage of recycled coarse aggregate(RCA),width of CFRP strips,spacing of CFRP strips and strength of recycled aggregate concrete(RAC)on the axial compression properties of columns were also analyzed in the experimental investigation.Furthermore,the finite element model of columns which can consider the adverse influence of RCA and the constraint effect of CFRP strips was founded by ABAQUS software and the nonlinear parameter analysis of columns was also implemented in this study.The results show that the first to reach the yield state was the profile steel in the columns,then the longitudinal rebars and stirrups yielded successively,and finally RAC was crushed as well as the CFRP strips was also broken.The replacement rate of RCA has little effect on the columns,and with the substitution rate of RCA from 0 to 100%,the bearing capacity of columns decreased by only 4.8%.Increasing the CFRP strips width or decreasing the CFRP strips spacing could enhance the axial bearing capacity of columns,the maximum increase was 10.5%or 11.4%,and the ductility of columns was significantly enhanced.Obviously,CFRP strips are conducive to enhance the axial bearing capacity and deformation capacity of columns.On this basis,considering the restraint effect of CFRP strips and the adverse effects of RCA,the revised formulas for calculating the axial bearing capacity of SRRC short columns confined by CFRP strips were proposed. 展开更多
关键词 steel reinforced recycled concrete CFRP strips short columns axial compression behavior recycled aggregate concrete
原文传递
Stress-strain relationship of recycled self-compacting concrete filled steel tubular column subjected to eccentric compression
17
作者 Feng YU Cheng QIN +2 位作者 Shilong WANG Junjie JIANG Yuan FANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第3期760-772,共13页
As a typical compression member,the concrete-filled steel tube has been widely used in civil engineering structures.However,little research on recycled self-compacting concrete flled circular steel tubular(RSCCFCST)co... As a typical compression member,the concrete-filled steel tube has been widely used in civil engineering structures.However,little research on recycled self-compacting concrete flled circular steel tubular(RSCCFCST)columns subjected to eccentric load was reported.In this study,21 specimens were designed and experimental studies on the stress-strain relationship of were carried out to study the mechanical behaviors.Recycled coarse aggregate replacement ratio,concrete strength grade,length to diameter ratio and eccentric distance of specimens were considered as the main experimental parameters to carry out eccentric compression tests.The corresponding stress-strain relationship curves were used to analyze the influence of concerned parameters on ecentric load-bearing capacity of RSCCFCST columns.The experimental results show that the strain of the eccentric compression stress-strain curves increase with the increase of recycled coarse aggregate replacement ratio and concrete strength grade.With increase of eccentric distance,the ductility of specimens increases while the bearing capacity decreases.Moreover,a phenomenological model of RSCCFCST columns is proposed,which exhibits versatile ability to capture the process during loading.The present study is expected to further understanding the behaviors and to provide guidance of RSCCFCST columns in design and engineering applications. 展开更多
关键词 concrete flleld circular steel tubular columns recycled self-compacting concrete eccentric compression recycled coarse aggregate replacement ratio stress-strain relationship
原文传递
A New Method for Predicting the UL of Circular CFST Columns
18
作者 Xinmeng Yu Baochun Chen 《Open Journal of Civil Engineering》 2013年第3期188-193,共6页
Concrete filled steel tube structures have gained booming development in recent decades, especially in China. Simplified methods have been proposed in design codes, such as the Eurocode 4 (EC4) and the China engineeri... Concrete filled steel tube structures have gained booming development in recent decades, especially in China. Simplified methods have been proposed in design codes, such as the Eurocode 4 (EC4) and the China engineering and construction specification (CECS). In EC4, the confinement effect is reasonably related to slenderness and load eccentricity. The CECS method is much straight forward in that the slenderness ratio and load eccentricity are treated as independent reduction factors. To make use of the advantages of both the CECS and the EC4 methods, the CECS method is modified to consider the confinement effect associated with slenderness and load eccentricity. It is shown that the proposed method can predict well the ultimate load capacity of circular section concrete filled steel tube columns. 展开更多
关键词 concrete FILLED steel tube column ULTIMATE Load Capacity Simplified Method Reduction Factor
下载PDF
反复荷载下圆钢管型钢再生混凝土组合柱恢复力模型研究 被引量:2
19
作者 马辉 刘一 +1 位作者 赵艳丽 白恒宇 《计算力学学报》 CAS CSCD 北大核心 2024年第2期320-327,共8页
为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合... 为建立圆钢管型钢再生混凝土组合柱的恢复力模型,对11根圆钢管型钢再生混凝土组合柱试件进行了低周反复荷载试验研究,考虑了再生骨料取代率、配钢率及钢管径厚比等不同设计参数的影响,分析了组合柱的地震破坏形态及滞回性能。基于组合柱的力学特征及曲线形状,提出了圆钢管型钢再生混凝土组合柱骨架曲线的三折线参数模型,采用理论推导与数据拟合的方法确定了组合柱骨架曲线的模型参数。在此基础上,给出了组合柱的滞回规则和卸载规律,构建了组合柱的恢复力模型,计算滞回曲线与试验滞回曲线吻合良好,表明该恢复力模型较好地反映了反复荷载下组合柱的受力特征点及滞回性能,可为此类组合柱的推广提供技术参考。 展开更多
关键词 型钢再生混凝土 钢管再生混凝土柱 恢复力模型 骨架曲线 滞回曲线
下载PDF
圆钢管型钢再生混凝土组合柱滞回性能非线性有限元分析 被引量:1
20
作者 马辉 张国恒 +2 位作者 白恒宇 席嘉诚 赵艳丽 《应用力学学报》 CAS CSCD 北大核心 2024年第1期148-157,共10页
基于圆钢管型钢再生混凝土组合柱低周反复荷载试验研究,采用OpenSees软件对该组合柱进行了滞回性能数值分析,获取了组合柱的滞回曲线及抗震性能指标,并与试验结果进行了比较,验证了组合柱数值模型的合理性。在此基础上,对组合柱的滞回... 基于圆钢管型钢再生混凝土组合柱低周反复荷载试验研究,采用OpenSees软件对该组合柱进行了滞回性能数值分析,获取了组合柱的滞回曲线及抗震性能指标,并与试验结果进行了比较,验证了组合柱数值模型的合理性。在此基础上,对组合柱的滞回性能开展了参数影响分析。结果表明:再生骨料取代率从0增大到100%,组合柱的峰值荷载下降了7.78%,延性略有降低;提高再生混凝土强度、型钢强度及圆钢管强度,对于提升组合柱的承载力及刚度是有利的,但却使组合柱的脆性增大;随着轴压比的增大,组合柱的承载力呈现先上升后下降的趋势,而延性逐渐变差;型钢配钢率从5.54%增至9.99%,组合柱的峰值荷载提高了24.34%,但对于改善组合柱的延性不明显;增大钢管壁厚对组合柱的承载力和延性均是有利的。 展开更多
关键词 钢管再生混凝土 型钢再生混凝土 组合柱 滞回性能 有限元分析
下载PDF
上一页 1 2 89 下一页 到第
使用帮助 返回顶部