A unilateral self-locking mechanism(USM) was proposed to increase the tractive ability of the inchworm in-pipe robots for pipeline inspection.The USM was basically composed of a cam,a torsional spring and an axis.The ...A unilateral self-locking mechanism(USM) was proposed to increase the tractive ability of the inchworm in-pipe robots for pipeline inspection.The USM was basically composed of a cam,a torsional spring and an axis.The self-locking and virtual work principles were applied to studying the basic self-locking condition of the USM.In order to make the cooperation between the crutch and telescopic mechanism more harmonical,the unlocking time of the USM was calculated.A set of parameters were selected to build a virtual model and fabricate a prototype.Both the simulation and performance experiments were carried out in a pipe with a nominal inside diameter of 160 mm.The results show that USM enables the robot to move quickly in one way,and in the other way it helps the robot get self-locking with the pipe wall.The traction of the inchworm robot can rise to 1.2 kN,beyond the limitation of friction of 0.497 kN.展开更多
BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plat...BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plate may cause various complications.The invention of the ACDF with a self-locking fusion cage(ROI-C)has effectively decreased the incidence of postoperative complications.AIM To observe the outcomes of CDD disease treated by ACDF with a ROI-C.METHODS Ninety patients with CDD disease treated at our hospital from March 2019 to March 2021 were included.They were divided into two groups(control group and observation group,n=45 in each)using a random number table.Patients in the control group received ACDF plus internal fixation with a titanium plate.Those in the observation group received ACDF+ROI-C placement.The two groups of patients were compared in terms of surgical parameters,pain,cervical spine function,range of motion,and complications.RESULTS The two groups of patients showed no significant differences in surgical time,blood loss,drainage volume,and length of hospital stay(P>0.05).No significant differences in the visual analogue scale(VAS),Japanese Orthopedic Association(JOA),and neck disability index(NDI)scores were observed between the two groups before surgery(P>0.05).The VAS and NDI scores in the observation group were considerably lower than those in the control group after surgery;however,the JOA scores in the observation group were significantly higher than those in the control group(P<0.05).No significant differences were observed in cervical disc height and the range of motion of the superior or inferior adjacent vertebrae between the two groups before surgery(P>0.05).The disc height in the observation group was larger than that in the control group after surgery.The range of motion of both the superior and inferior adjacent vertebrae was significantly smaller in the observation group than in the control group(P<0.05).The incidence of complications was only 2.22% in the observation group compared to 15.56% in the control group,and the difference was statistically significant(P<0.05).CONCLUSION Cervical spine function restoration was better with ROI-C with internal fixation in ACDF than with conventional titanium plates in ACDF for CDD disease.展开更多
We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuratio...We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuration lessens wear, increases load capacity, and improves efficiency. The threaded chain consists of nut-shaped links. This paper presents the results of tests carried out on a prototype with a reduction ratio of 46.展开更多
针对基于Linux和TCG软件栈(Trusted computing group Software Stack,TSS)的复杂性问题,提出一种轻量级的可信软件栈。分析了TSS的基本结构与TSS在嵌入式系统的局限,总结出基于嵌入式系统的可信软件栈设计需求,设计出软件栈命令调用的...针对基于Linux和TCG软件栈(Trusted computing group Software Stack,TSS)的复杂性问题,提出一种轻量级的可信软件栈。分析了TSS的基本结构与TSS在嵌入式系统的局限,总结出基于嵌入式系统的可信软件栈设计需求,设计出软件栈命令调用的机制和软件栈的结构。此外,分析了TSS密钥管理缓存算法,在flash中定义一块密钥槽空间,方便密钥管理中直接访问,阐述密钥生成的逻辑过程,实现面向嵌入式系统的可信软件系统。经实验验证,该软件栈可以结合RT-Thread实时系统实现基本的可信计算功能。展开更多
基金Project(2007AA04Z256) supported by the National High-Tech Research and Development Program of China
文摘A unilateral self-locking mechanism(USM) was proposed to increase the tractive ability of the inchworm in-pipe robots for pipeline inspection.The USM was basically composed of a cam,a torsional spring and an axis.The self-locking and virtual work principles were applied to studying the basic self-locking condition of the USM.In order to make the cooperation between the crutch and telescopic mechanism more harmonical,the unlocking time of the USM was calculated.A set of parameters were selected to build a virtual model and fabricate a prototype.Both the simulation and performance experiments were carried out in a pipe with a nominal inside diameter of 160 mm.The results show that USM enables the robot to move quickly in one way,and in the other way it helps the robot get self-locking with the pipe wall.The traction of the inchworm robot can rise to 1.2 kN,beyond the limitation of friction of 0.497 kN.
文摘BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plate may cause various complications.The invention of the ACDF with a self-locking fusion cage(ROI-C)has effectively decreased the incidence of postoperative complications.AIM To observe the outcomes of CDD disease treated by ACDF with a ROI-C.METHODS Ninety patients with CDD disease treated at our hospital from March 2019 to March 2021 were included.They were divided into two groups(control group and observation group,n=45 in each)using a random number table.Patients in the control group received ACDF plus internal fixation with a titanium plate.Those in the observation group received ACDF+ROI-C placement.The two groups of patients were compared in terms of surgical parameters,pain,cervical spine function,range of motion,and complications.RESULTS The two groups of patients showed no significant differences in surgical time,blood loss,drainage volume,and length of hospital stay(P>0.05).No significant differences in the visual analogue scale(VAS),Japanese Orthopedic Association(JOA),and neck disability index(NDI)scores were observed between the two groups before surgery(P>0.05).The VAS and NDI scores in the observation group were considerably lower than those in the control group after surgery;however,the JOA scores in the observation group were significantly higher than those in the control group(P<0.05).No significant differences were observed in cervical disc height and the range of motion of the superior or inferior adjacent vertebrae between the two groups before surgery(P>0.05).The disc height in the observation group was larger than that in the control group after surgery.The range of motion of both the superior and inferior adjacent vertebrae was significantly smaller in the observation group than in the control group(P<0.05).The incidence of complications was only 2.22% in the observation group compared to 15.56% in the control group,and the difference was statistically significant(P<0.05).CONCLUSION Cervical spine function restoration was better with ROI-C with internal fixation in ACDF than with conventional titanium plates in ACDF for CDD disease.
文摘We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuration lessens wear, increases load capacity, and improves efficiency. The threaded chain consists of nut-shaped links. This paper presents the results of tests carried out on a prototype with a reduction ratio of 46.
文摘针对基于Linux和TCG软件栈(Trusted computing group Software Stack,TSS)的复杂性问题,提出一种轻量级的可信软件栈。分析了TSS的基本结构与TSS在嵌入式系统的局限,总结出基于嵌入式系统的可信软件栈设计需求,设计出软件栈命令调用的机制和软件栈的结构。此外,分析了TSS密钥管理缓存算法,在flash中定义一块密钥槽空间,方便密钥管理中直接访问,阐述密钥生成的逻辑过程,实现面向嵌入式系统的可信软件系统。经实验验证,该软件栈可以结合RT-Thread实时系统实现基本的可信计算功能。