期刊文献+
共找到69,818篇文章
< 1 2 250 >
每页显示 20 50 100
MICRO-ROBOT FOR MEASUREMENT AND THREE-DIMENSION RECONSTRUCTION OF MICROPIPES 被引量:2
1
作者 Li Jiangxiong Ke Yinglin Guo Tong Wu Enqi Jin Chengzhu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第3期371-375,共5页
The presented system consists of field devices, a control system and a host computer system. The field devices, which are composed of an in-pipe micro-robot, a displacement sensor, a curvature sensor, and an inner sur... The presented system consists of field devices, a control system and a host computer system. The field devices, which are composed of an in-pipe micro-robot, a displacement sensor, a curvature sensor, and an inner surface measurement unit, can go into the pipe to get the data of displace- ment and axis curvature, and the shape data of the inner surface. With the conic-shape laser beam shot by the inner surface measurement unit, the intersectional curve between the laser beam and the inner-surface of the tested pipe can be calculated in the local coordination system (LCS) of the inner surface measurement unit. The relation between the LCS and the global coordination system (GCS) can be deduced, too. After the robot reaches the end of the pipe, all measured intersectional curves can be translated into the same coordination system to become a point cloud of the inner surface of the pipe according to the relations between LCS and GCS. Depending on this points cloud, the CAD model of the inner surface of the pipe can be reconstructed easily with reverse engineering tools, and the feature of flaw of the pipe can be obtained with flaw analysis tools. 展开更多
关键词 3D reconstruction Curved micro-pipe In-pipe micro-robot
下载PDF
Computed tomography three-dimensional reconstruction in the diagnosis of bleeding small intestinal polyps:A case report
2
作者 Shu-Hui Zhang Ming-Wei Fan +2 位作者 Yan Chen Ying-Bin Hu Cheng-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第16期2831-2836,共6页
BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s... BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy. 展开更多
关键词 Computed tomography three-dimensional reconstruction Capsule endoscopy Single-balloon enteroscopy Gastrointestinal bleeding Case report
下载PDF
Evaluating the use of three-dimensional reconstruction visualization technology for precise laparoscopic resection in gastroesophageal junction cancer
3
作者 Dan Guo Xiao-Yan Zhu +2 位作者 Shuai Han Yu-Shu Liu Da-Peng Cui 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第5期1311-1319,共9页
BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby provi... BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby providing patients with better treatment outcomes and quality of life.Nonetheless,this surgical technique also presents some challenges and limitations.Therefore,three-dimensional reconstruction visualization technology(3D RVT)has been introduced into the procedure,providing doctors with more comprehensive and intuitive anatomical information that helps with surgical planning,navigation,and outcome evaluation.AIM To discuss the application and advantages of 3D RVT in precise laparoscopic resection of EGJ carcinomas.METHODS Data were obtained from the electronic or paper-based medical records at The First Affiliated Hospital of Hebei North University from January 2020 to June 2022.A total of 120 patients diagnosed with EGJ carcinoma were included in the study.Of these,68 underwent laparoscopic resection after computed tomography(CT)-enhanced scanning and were categorized into the 2D group,whereas 52 underwent laparoscopic resection after CT-enhanced scanning and 3D RVT and were categorized into the 3D group.This study had two outcome measures:the deviation between tumor-related factors(such as maximum tumor diameter and infiltration length)in 3D RVT and clinical reality,and surgical outcome indicators(such as operative time,intraoperative blood loss,number of lymph node dissections,R0 resection rate,postoperative hospital stay,postoperative gas discharge time,drainage tube removal time,and related complications)between the 2D and 3D groups.RESULTS Among patients included in the 3D group,27 had a maximum tumor diameter of less than 3 cm,whereas 25 had a diameter of 3 cm or more.In actual surgical observations,24 had a diameter of less than 3 cm,whereas 28 had a diameter of 3 cm or more.The findings were consistent between the two methods(χ^(2)=0.346,P=0.556),with a kappa consistency coefficient of 0.808.With respect to infiltration length,in the 3D group,23 patients had a length of less than 5 cm,whereas 29 had a length of 5 cm or more.In actual surgical observations,20 cases had a length of less than 5 cm,whereas 32 had a length of 5 cm or more.The findings were consistent between the two methods(χ^(2)=0.357,P=0.550),with a kappa consistency coefficient of 0.486.Pearson correlation analysis showed that the maximum tumor diameter and infiltration length measured using 3D RVT were positively correlated with clinical observations during surgery(r=0.814 and 0.490,both P<0.05).The 3D group had a shorter operative time(157.02±8.38 vs 183.16±23.87),less intraoperative blood loss(83.65±14.22 vs 110.94±22.05),and higher number of lymph node dissections(28.98±2.82 vs 23.56±2.77)and R0 resection rate(80.77%vs 61.64%)than the 2D group.Furthermore,the 3D group had shorter hospital stay[8(8,9)vs 13(14,16)],time to gas passage[3(3,4)vs 4(5,5)],and drainage tube removal time[4(4,5)vs 6(6,7)]than the 2D group.The complication rate was lower in the 3D group(11.54%)than in the 2D group(26.47%)(χ^(2)=4.106,P<0.05).CONCLUSION Using 3D RVT,doctors can gain a more comprehensive and intuitive understanding of the anatomy and related lesions of EGJ carcinomas,thus enabling more accurate surgical planning. 展开更多
关键词 Gastroesophageal junction cancer ENDOSCOPY Tumor resection three-dimensional reconstruction visualization Two-dimensional imaging computed tomography
下载PDF
GPU-accelerated three-dimensional reconstruction method of the Compton camera and its application in radionuclide imaging 被引量:1
4
作者 Ren-Yao Wu Chang-Ran Geng +6 位作者 Feng Tian Zhi-Yang Yao Chun-Hui Gong Hao-Nan Han Jian-Feng Xu Yong-Shun Xiao Xiao-Bin Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期54-68,共15页
A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method wit... A novel and fast three-dimensional reconstruction method for a Compton camera and its performance in radionuclide imaging is proposed and analyzed in this study. The conical surface sampling back-projection method with scattering angle correction(CSS-BP-SC) can quickly perform the back-projection process of the Compton cone and can be used to precompute the list-mode maximum likelihood expectation maximization(LM-MLEM). A dedicated parallel architecture was designed for the graphics processing unit acceleration of the back-projection and iteration stage of the CSS-BP-SC-based LM-MLEM. The imaging results of the two-point source Monte Carlo(MC) simulation demonstrate that by analyzing the full width at half maximum along the three coordinate axes, the CSS-BP-SC-based LM-MLEM can obtain imaging results comparable to those of the traditional reconstruction algorithm, that is, the simple back-projection-based LM-MLEM. The imaging results of the mouse phantom MC simulation and experiment demonstrate that the reconstruction results obtained by the proposed method sufficiently coincide with the set radioactivity distribution, and the speed increased by more than 664 times compared to the traditional reconstruction algorithm in the mouse phantom experiment. The proposed method will further advance the imaging applications of Compton cameras. 展开更多
关键词 Compton camera three-dimensional reconstruction Radionuclide imaging GPU
下载PDF
Three-dimensional computed tomography reconstruction diagnosed digestive tract perforation and acute peritonitis caused by Monopterus albus:A case report
5
作者 Jin-Han Yang Jin-Ying Lan +2 位作者 An-Yuan Lin Wei-Biao Huang Jin-Yuan Liao 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第10期2351-2356,共6页
BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign... BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic. 展开更多
关键词 Digestive tract perforation Acute peritonitis Monopterus albus three-dimensional computed tomography reconstruction Case report
下载PDF
Image processing based three-dimensional model reconstruction for cross-platform numerical simulation
6
作者 Yu-cheng Sun Yu-hang Huang +5 位作者 Na Li Xiao Han Ai-long Jiang Jin-wu Kang Ji-wu Wang Hai-liang Yu 《China Foundry》 SCIE CAS CSCD 2023年第2期139-147,共9页
Numerical simulation is the most powerful computational and analysis tool for a large variety of engineering and physical problems.For a complex problem relating to multi-field,multi-process and multi-scale,different ... Numerical simulation is the most powerful computational and analysis tool for a large variety of engineering and physical problems.For a complex problem relating to multi-field,multi-process and multi-scale,different computing tools have to be developed so as to solve particular fields at different scales and for different processes.Therefore,the integration of different types of software is inevitable.However,it is difficult to perform the transfer of the meshes and simulated results among software packages because of the lack of shared data formats or encrypted data formats.An image processing based method for three-dimensional model reconstruction for numerical simulation was proposed,which presents a solution to the integration problem by a series of slice or projection images obtained by the post-processing modules of the numerical simulation software.By means of mapping image pixels to meshes of either finite difference or finite element models,the geometry contour can be extracted to export the stereolithography model.The values of results,represented by color,can be deduced and assigned to the meshes.All the models with data can be directly or indirectly integrated into other software as a continued or new numerical simulation.The three-dimensional reconstruction method has been validated in numerical simulation of castings and case studies were provided in this study. 展开更多
关键词 cross-platform numerical simulation 3D model reconstruction image processing SLICE
下载PDF
Multi-Segmental Osteocutaneous Free Fibula Flap for Three-Dimensional Post-Traumatic Thumb and Wrist Reconstruction
7
作者 Jack D. Sudduth Shireen Dogar +1 位作者 Narges L. Horriat Marc E. Walker 《Modern Plastic Surgery》 2023年第1期23-31,共9页
Thumb reconstruction following a traumatic injury challenge depends on the extent of the injury. Ideally, reconstruction should restore thumb length and position and retain thumb stability, mobility, and strength, whi... Thumb reconstruction following a traumatic injury challenge depends on the extent of the injury. Ideally, reconstruction should restore thumb length and position and retain thumb stability, mobility, and strength, while preserving sensation and aesthetics. Achieving these outcomes can be especially challenging in severe cases of soft tissue and bony loss. The authors present a case of a 20-year-old right-hand dominant female involved in a motor vehicle accident who sustained severe crush injuries and burns to her right hand. Her injuries included soft tissue and bony defects extending from the thumb to the distal radius, namely avulsion of the thumb and significant loss of the distal radial and carpal column, resulting in severe wrist instability. We employed a three-segment vascularized osteocutaneous fibula flap to reconstruct the thumb and wrist to restore bony construct, carpal support, and soft tissue coverage. Thumb motion could not be achieved, but this technique offered a sensate, functional post for opposition and the appearance of an anatomic hand. Because of this surgery, the patient was enabled to graduate from college and pursue full-time employment. The authors hope that this report will add to the fund of knowledge and surgeon armamentarium for similar devastating injuries demanding thumb and wrist reconstruction. 展开更多
关键词 Thumb reconstruction Wrist reconstruction Microvascular reconstruction Free Fibula Flap Thumb Amputation
下载PDF
SAR regional all-azimuth observation orbit design for target 3D reconstruction
8
作者 WANG Yanan ZHOU Chaowei +1 位作者 LIU Aifang MAO Qin 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期609-618,共10页
Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, ... Three-dimensional(3D) synthetic aperture radar(SAR)extends the conventional 2D images into 3D features by several acquisitions in different aspects. Compared with 3D techniques via multiple observations in elevation, e.g. SAR interferometry(InSAR) and SAR tomography(TomoSAR), holographic SAR can retrieve 3D structure by observations in azimuth. This paper focuses on designing a novel type of orbit to achieve SAR regional all-azimuth observation(AAO) for embedded targets detection and holographic 3D reconstruction. The ground tracks of the AAO orbit separate the earth surface into grids. Target in these grids can be accessed with an azimuth angle span of360°, which is similar to the flight path of airborne circular SAR(CSAR). Inspired from the successive coverage orbits of optical sensors, several optimizations are made in the proposed method to ensure favorable grazing angles, the performance of 3D reconstruction, and long-term supervision for SAR sensors. Simulation experiments show the regional AAO can be completed within five hours. In addition, a second AAO of the same area can be duplicated in two days. Finally, an airborne SAR data process result is presented to illustrate the significance of AAO in 3D reconstruction. 展开更多
关键词 synthetic aperture radar(SAR) orbit design all-azimuth observation(AAO) three-dimensional(3D)reconstruction successive coverage
下载PDF
Sparse Modal Decomposition Method Addressing Underdetermined Vortex-Induced Vibration Reconstruction Problem for Marine Risers 被引量:1
9
作者 DU Zun-feng ZHU Hai-ming YU Jian-xing 《China Ocean Engineering》 SCIE EI CSCD 2024年第2期285-296,共12页
When investigating the vortex-induced vibration(VIV)of marine risers,extrapolating the dynamic response on the entire length based on limited sensor measurements is a crucial step in both laboratory experiments and fa... When investigating the vortex-induced vibration(VIV)of marine risers,extrapolating the dynamic response on the entire length based on limited sensor measurements is a crucial step in both laboratory experiments and fatigue monitoring of real risers.The problem is conventionally solved using the modal decomposition method,based on the principle that the response can be approximated by a weighted sum of limited vibration modes.However,the method is not valid when the problem is underdetermined,i.e.,the number of unknown mode weights is more than the number of known measurements.This study proposed a sparse modal decomposition method based on the compressed sensing theory and the Compressive Sampling Matching Pursuit(Co Sa MP)algorithm,exploiting the sparsity of VIV in the modal space.In the validation study based on high-order VIV experiment data,the proposed method successfully reconstructed the response using only seven acceleration measurements when the conventional methods failed.A primary advantage of the proposed method is that it offers a completely data-driven approach for the underdetermined VIV reconstruction problem,which is more favorable than existing model-dependent solutions for many practical applications such as riser structural health monitoring. 展开更多
关键词 motion reconstruction vortex-induced vibration(VIV) marine riser modal decomposition method compressed sensing
下载PDF
Estimation-free spatial-domain image reconstruction of structured illumination microscopy 被引量:1
10
作者 Xiaoyan Li Shijie Tu +4 位作者 Yile Sun Yubing Han Xiang Hao Cuifang kuang Xu Liu 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期45-58,共14页
Structured illumination microscopy(SIM)achieves super-resolution(SR)by modulating the high-frequency information of the sample into the passband of the optical system and subsequent image reconstruction.The traditiona... Structured illumination microscopy(SIM)achieves super-resolution(SR)by modulating the high-frequency information of the sample into the passband of the optical system and subsequent image reconstruction.The traditional Wiener-filtering-based reconstruction algorithm operates in the Fourier domain,it requires prior knowledge of the sinusoidal illumination patterns which makes the time-consuming procedure of parameter estimation to raw datasets necessary,besides,the parameter estimation is sensitive to noise or aberration-induced pattern distortion which leads to reconstruction artifacts.Here,we propose a spatial-domain image reconstruction method that does not require parameter estimation but calculates patterns from raw datasets,and a reconstructed image can be obtained just by calculating the spatial covariance of differential calculated patterns and differential filtered datasets(the notch filtering operation is performed to the raw datasets for attenuating and compensating the optical transfer function(OTF)).Experiments on reconstructing raw datasets including nonbiological,biological,and simulated samples demonstrate that our method has SR capability,high reconstruction speed,and high robustness to aberration and noise. 展开更多
关键词 Structured illumination microscopy image reconstruction spatial domain digital micromirror device(DMD)
下载PDF
Post-disaster spatial reconstruction from the perspective of a rural settlement niche in the upper reaches of the Minjiang River
11
作者 LIU Yanguo WANG Li +5 位作者 ZOU Qiang LI Jingji LU Yafeng LI Lin XU Binni WANG Lihui 《Journal of Mountain Science》 SCIE CSCD 2024年第5期1630-1646,共17页
Post-disaster recovery and reconstruction provide an effective way to reduce the disaster vulnerability of, and promote leapfrog development in, an affected area. To date, studies that have used administrative boundar... Post-disaster recovery and reconstruction provide an effective way to reduce the disaster vulnerability of, and promote leapfrog development in, an affected area. To date, studies that have used administrative boundaries to investigate the reconstruction of settlement space have not been able to clearly define the real boundaries of land use changes or quantify the degree of response to the ‘Build-Back-Better’ initiative, and have lacked any consideration of the fourth reconstruction stage–development period(10 years). This study constructed a mountain settlement niche and analyzed the characteristics, spatial reconstruction, and drivers of rural settlements during 2009–2019 in the upper reaches of the Minjiang River, southwest China. The results showed the following:(1) Natural factors were the basis for the formation and development of mountain settlement niches. The scale of the settlement niche and its land use structure depended on the physical geography features and the ethnic farming and grazing traditions. The settlement niche provided a realistic boundary for the spatial reconstruction.(2) The layout of residential land around cropland was the common feature of the mountain settlement niche. Of all the land use types, the roads and rural residential lands showed the most change over the 10 years;13,860 residential patches increased in size and 4,742 patches were abandoned.(3) The area of orchards, planted to reconstruct the economy in the mountains, increased by nearly 2.5 times.(4) Collapses, landslides, and debris flow disasters and the ecological red line influenced the spatial reconstruction. While the main focus of post-disaster recovery is spatial reconstruction, initiatives should include economic and spiritual recovery, and should also achieve sustainable development of the region. 展开更多
关键词 Rural settlements Spatial reconstruction Settlement niche Post-Wenchuan Earthquake reconstruction Southwest China
下载PDF
Quantitative geochemical reconstruction of Eocene paleoenvironment in Fushun Basin,northeast China
12
作者 Yuanji Li Pingchang Sun +1 位作者 Qiang Zhang Junxian Wang 《Acta Geochimica》 EI CAS CSCD 2024年第3期571-587,共17页
The quantitative estimation of key parameters of paleotemperature and paleoprecipitation is crucial for paleoclimate reconstruction.Geochemical data from mod-ern sediments are highly consistent with climate data,and t... The quantitative estimation of key parameters of paleotemperature and paleoprecipitation is crucial for paleoclimate reconstruction.Geochemical data from mod-ern sediments are highly consistent with climate data,and their relationship can provide an important reference for the quantitative reconstruction of the paleoclimate.In this study,detailed inorganic geochemical analysis was carried out using high-precision sampling of the Paleogene(LFD-1 well)Guchengzi,Jijuntun and Xiloutian Formations in the Fushun Basin located in the mid-latitudes of the Northern Hemisphere.The Eocene Guchengzi Formation(54.51–47.8 Ma)and Jijuntun Formation(47.8–41.2 Ma)in the Fushun Basin were found to have been deposited under a humid climate.The lower(41.2–40.1 Ma)and upper(40.1–37.8 Ma)parts of the Xiloutian Formation were character-ized by semiarid and semihumid–semiarid climates,respec-tively,which is very similar to the paleoclimatic information reflected by organic carbon isotopes.The Eocene Thermal Maximum 2(ETM2,~53.7 Ma),Early Eocene Climatic Optimum(EECO,~53.1–46.5 Ma),Eocene Thermal Maxi-mum 3(ETM 3,~52.8 Ma),and Middle Eocene Climatic Optimum(MECO,~40.7–40.1 Ma)events significantly enhanced chemical weathering during these periods.The rapid increase in pCO_(2)concentration leads to an increase in temperature,precipitation,and surface runoff,exhibiting strong chemical weathering.The mean annual temperature(MATa)and mean annual precipitation(MAPa,MAPb,and MAPc)were estimated using parameters,such as the corrosion index without potassium(CIA-K),CaO/Al_(2)O_(3),and(Na_(2)O+K_(2)O)/Al_(2)O_(3).Comparing MAPa,MAPb,and MAPc with the MAP estimated using pollen data,MAPa and MAPb were found to be more sensitive to the climate during high precipitation periods(precipitation>1000 mm,Guchengzi Formation),and the recovered average precipi-tation was similar to MAP.In contrast,MAPc was more sensitive to the climate during low precipitation periods(precipitation<1000 mm,Jijuntun,and Xiloutian Forma-tions),with higher accuracy.To fully consider the influence of soluble inorganic salts Ca^(2+)and Na^(+),multivariate linear equations of CIA-K and CaO/Al_(2)O_(3)with CIA,and CIA-K and CaO/Al_(2)O_(3)with MAP were constructed,namely MAPd and MAPe.The results show that MAPe has the highest per-formance and can be effectively used to estimate the change of paleoprecipitation in Northeast Asia. 展开更多
关键词 EOCENE Fushun Basin Major element PALEOCLIMATE Geochemical reconstruction
下载PDF
Comparative analysis of two digestive tract reconstruction methods in total laparoscopic radical total gastrectomy
13
作者 Tian-Xiang Dong Dong Wang +10 位作者 Qun Zhao Zhi-Dong Zhang Xue-Feng Zhao Bi-Bo Tan Yu Liu Qing-Wei Liu Pei-Gang Yang Ping-An Ding Tao Zheng Yong Li Zi-Jing Liu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第4期1109-1120,共12页
BACKGROUND The incidence of gastric cancer has significantly increased in recent years.Surgical resection is the main treatment,but the method of digestive tract reconstruction after gastric cancer surgery remains con... BACKGROUND The incidence of gastric cancer has significantly increased in recent years.Surgical resection is the main treatment,but the method of digestive tract reconstruction after gastric cancer surgery remains controversial.In the current study,we sought to explore a reasonable method of digestive tract reconstruction and improve the quality of life and nutritional status of patients after surgery.To this end,we statistically analyzed the clinical results of patients with gastric cancer who underwent jejunal interposition double-tract reconstruction(DTR)and esophageal jejunum Roux-en-Y reconstruction(RY).AIM To explore the application effect of DTR in total laparoscopic radical total gastrectomy(TLTG)and evaluate its safety and efficacy.METHODS We collected the relevant data of 77 patients who underwent TLTG at the Fourth Hospital of Hebei Medical University from October 2021 to January 2023.Among them,35 cases were treated with DTR,and the remaining 42 cases were treated with traditional RY.After 1:1 propensity score matching,the cases were grouped into 31 cases per group,with evenly distributed data.The clinical characteristics and short-and long-term clinical outcomes of the two groups were statistically analyzed.RESULTS The two groups showed no significant differences in basic data,intraoperative blood loss,number of lymph node dissections,first defecation time after operation,postoperative hospital stay,postoperative complications,and laboratory examination results on the 1st,3rd,and 5th days after operation.The operation time of the DTR group was longer than that of the RY group[(307.58±65.14)min vs(272.45±62.09)min,P=0.016],but the first intake of liquid food in the DTR group was shorter than that in the RY group[(4.45±1.18)d vs(6.0±5.18)d,P=0.028].The incidence of reflux heartburn(Visick grade)and postoperative gallbladder disease in the DTR group was lower than that in the RY group(P=0.033 and P=0.038).Although there was no significant difference in body weight,hemoglobin,prealbumin,and albumin between the two groups at 1,3 and 6 months after surgery,the diet of patients in the DTR group was better than that in the RY group(P=0.031).CONCLUSION The clinical effect of DTR in TLTG is better than that of RY,indicating that it is a more valuable digestive tract reconstruction method in laparoscopic gastric cancer surgery. 展开更多
关键词 Gastric cancer Jejunal interposition double-tract reconstruction Roux-en-Y reconstruction LAPAROSCOPE
下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
14
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
下载PDF
Application of multi-planar reconstruction technique in endovascular repair of aortic dissection
15
作者 Guo-Jie Li Ming-Xian Zhao 《World Journal of Clinical Cases》 SCIE 2024年第17期2989-2994,共6页
BACKGROUND Endovascular repair of aortic dissection is an effective method commonly used in the treatment of Stanford type B aortic dissection.Stent placement during the operation was one-time and could not be repeate... BACKGROUND Endovascular repair of aortic dissection is an effective method commonly used in the treatment of Stanford type B aortic dissection.Stent placement during the operation was one-time and could not be repeatedly adjusted during the operation.Therefore,it is of great significance for cardiovascular physicians to fully understand the branch status,position,angle,and other information regarding aortic arch dissection before surgery.AIM To provide more references for clinical cardiovascular physicians to develop treatment plans.METHODS Data from 153 patients who underwent endovascular repair of aortic dissection at our hospital between January 2021 and December 2022 were retrospectively collected.All patients underwent multi-slice spiral computed tomography angiography.Based on distinct post-image processing techniques,the patients were categorized into three groups:Multiplanar reconstruction(MPR)(n=55),volume reconstruction(VR)(n=46),and maximum intensity projection(MIP)(n=52).The detection rate of aortic rupture,accuracy of the DeBakey classification,rotation,and tilt angles of the C-arm during the procedure,dispersion after stent release,and the incidence of late complications were recorded and compared.RESULTS The detection rates of interlayer rupture in the MPR and VR groups were significantly higher than that in the MIP group(P<0.05).The detection rates of De-Bakey subtypesⅠ,Ⅱ,andⅢin the MPR group were higher than those in the MIP group,and the detection rate of typeⅢin the MPR group was significantly higher than that in the VR group(P<0.05).There was no statistically significant difference in the detection rates of typesⅠandⅡcompared to the VR group(P>0.05).The scatter rate of markers and the incidence of complications in the MPR group were significantly lower than those in the VR and MIP groups(P<0.05).CONCLUSION The application of MPR in the endovascular repair of aortic dissection has improved the detection rate of dissection rupture,the accuracy of anatomical classification,and safety. 展开更多
关键词 Multiplanar reconstruction Endovascular repair of aortic dissection Image-processing technology Rate of aortic rupture Volume reconstruction
下载PDF
Scene 3-D Reconstruction System in Scattering Medium
16
作者 Zhuoyifan Zhang Lu Zhang +1 位作者 LiangWang Haoming Wu 《Computers, Materials & Continua》 SCIE EI 2024年第8期3405-3420,共16页
Research on neural radiance fields for novel view synthesis has experienced explosive growth with the development of new models and extensions.The NeRF(Neural Radiance Fields)algorithm,suitable for underwater scenes o... Research on neural radiance fields for novel view synthesis has experienced explosive growth with the development of new models and extensions.The NeRF(Neural Radiance Fields)algorithm,suitable for underwater scenes or scattering media,is also evolving.Existing underwater 3D reconstruction systems still face challenges such as long training times and low rendering efficiency.This paper proposes an improved underwater 3D reconstruction system to achieve rapid and high-quality 3D reconstruction.First,we enhance underwater videos captured by a monocular camera to correct the image quality degradation caused by the physical properties of the water medium and ensure consistency in enhancement across frames.Then,we perform keyframe selection to optimize resource usage and reduce the impact of dynamic objects on the reconstruction results.After pose estimation using COLMAP,the selected keyframes undergo 3D reconstruction using neural radiance fields(NeRF)based on multi-resolution hash encoding for model construction and rendering.In terms of image enhancement,our method has been optimized in certain scenarios,demonstrating effectiveness in image enhancement and better continuity between consecutive frames of the same data.In terms of 3D reconstruction,our method achieved a peak signal-to-noise ratio(PSNR)of 18.40 dB and a structural similarity(SSIM)of 0.6677,indicating a good balance between operational efficiency and reconstruction quality. 展开更多
关键词 Underwater scene reconstruction image enhancement NeRF
下载PDF
Model-driven CT reconstruction algorithm for nano-resolution x-ray phase contrast imaging
17
作者 谭雨航 蔡学宝 +5 位作者 杨杰成 苏婷 郑海荣 梁栋 朱佩平 葛永帅 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期646-650,共5页
The low-density imaging performance of a zone plate-based nano-resolution hard x-ray computed tomography(CT)system can be significantly improved by incorporating a grating-based Lau interferometer. Due to the diffract... The low-density imaging performance of a zone plate-based nano-resolution hard x-ray computed tomography(CT)system can be significantly improved by incorporating a grating-based Lau interferometer. Due to the diffraction, however,the acquired nano-resolution phase signal may suffer splitting problem, which impedes the direct reconstruction of phase contrast CT(nPCT) images. To overcome, a new model-driven nPCT image reconstruction algorithm is developed in this study. In it, the diffraction procedure is mathematically modeled into a matrix B, from which the projections without signal splitting can be generated invertedly. Furthermore, a penalized weighted least-square model with total variation(PWLSTV) is employed to denoise these projections, from which nPCT images with high accuracy are directly reconstructed.Numerical experiments demonstrate that this new algorithm is able to work with phase projections having any splitting distances. Moreover, results also reveal that nPCT images of higher signal-to-noise-ratio(SNR) could be reconstructed from projections having larger splitting distances. In summary, a novel model-driven nPCT image reconstruction algorithm with high accuracy and robustness is verified for the Lau interferometer-based hard x-ray nano-resolution phase contrast imaging. 展开更多
关键词 splitting phase image reconstruction algorithm grating interferometer
下载PDF
High formability Mg-Zn-Gd wire facilitates ACL reconstruction via its swift degradation to accelerate intra-tunnel endochondral ossification
18
作者 Xuan He Ye Li +14 位作者 Hongwei Miao Jiankun Xu Michael Tim-yun Ong Chenmin Wang Lizhen Zheng Jiali Wang Le Huang Haiyue Zu Zhi Yao Jie Mi Bingyang Dai Xu Li Patrick Shu-hang Yung Guangyin Yuan Ling Qin 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期295-315,共21页
After reconstructing the anterior cruciate ligament(ACL),unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage.With good biological features and high formability,M... After reconstructing the anterior cruciate ligament(ACL),unsatisfactory bone tendon interface healing may often induce tunnel enlargement at the early healing stage.With good biological features and high formability,Magnesium-Zinc-Gadolinium(ZG21)wires are developed to bunch the tendon graft for matching the bone tunnel during transplantation.Microstructure,tensile strength,degradation,and cytotoxicity of ZG21 wire are evaluated.The rabbit model is used for assessing the biological effects of ZG21 wire by Micro-CT,histology,and mechanical test.The SEM/EDS,immunochemistry,and in vitro assessments are performed to investigate the underlying mechanism.Material tests demonstrate the high formability of ZG21 wire as surgical suture.Micro-CT shows ZG21 wire degradation accelerates tunnel bone formation,and histologically with earlier and more fibrocartilage regeneration at the healing interface.The mechanical test shows higher ultimate load in the ZG21 group.The SEM/EDS presents ZG21 wire degradation triggered calcium phosphate(Ca-P)deposition.IHC results demonstrate upregulation of Wnt3a,BMP2,and VEGF at the early phase and TGFβ3 and Type II collagen at the late phase of healing.In vitro tests also confirmed the Ca-P in the metal extract could elevate the expression of Wnt3a,βcatenin,ocn and opn to stimulate osteogenesis.Ex vivo tests of clinical samples indicated suturing with ZG21 wire did not weaken the ultimate loading of human tendon tissue.In conclusion,the ZG21 wire is feasible for tendon graft bunching.Its degradation products accelerated intra-tunnel endochondral ossification at the early healing stage and therefore enhanced bone-tendon interface healing in ACL reconstruction. 展开更多
关键词 Magnesium wire ACL reconstruction Magnesium alloy BIOMATERIALS Endochondral ossification
下载PDF
FPGA-based position reconstruction method for neutron beam flux spatial distribution measurement in BNCT
19
作者 Wei Jiang Ping Cao +5 位作者 Yi-Ming Wu Xian-Ke Liu Zhu-Jun Fang Zhi-Yong Zhang Bin Shi Jun Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期96-108,共13页
A new measurement method for the spatial distribution of neutron beam flux in boron neutron capture therapy(BNCT)is being developed based on the two-dimensional Micromegas detector.To address the issue of long process... A new measurement method for the spatial distribution of neutron beam flux in boron neutron capture therapy(BNCT)is being developed based on the two-dimensional Micromegas detector.To address the issue of long processing times in traditional offline position reconstruction methods,this paper proposes a field programmable gate array based online position reconstruction method utilizing the micro-time projection chamber principle.This method encapsulates key technical aspects:a self-adaptive serial link technique built upon the dynamical adjustment of the delay chain length,fast sorting,a coordinate-matching technique based on the mapping between signal timestamps and random access memory(RAM)addresses,and a precise start point-merging technique utilizing a circular combined RAM.The performance test of the selfadaptive serial link shows that the bit error rate of the link is better than 10-12 at a confidence level of 99%,ensuring reliable data transmission.The experiment utilizing the readout electronics and Micromegas detector shows a spatial resolution of approximately 1.4 mm,surpassing the current method’s resolution level of 5 mm.The beam experiment confirms that the readout electronics system can obtain the flux spatial distribution of neutron beams online,thus validating the feasibility of the position reconstruction method.The online position reconstruction method avoids traditional methods,such as bubble sorting and traversal searching,simplifies the design of the logic firmware,and reduces the time complexity from O(n2)to O(n).This study contributes to the advancement in measuring neutron beam flux for BNCT. 展开更多
关键词 Position reconstruction FPGA Readout electronics Neutron flux spatial distribution
下载PDF
Stabilizing iridium sites via interface and reconstruction regulations for water oxidation in alkaline and acidic media
20
作者 Weibin Chen Yanhui Song +2 位作者 Lei Li Junjie Guo Zhan Lin 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期355-363,I0009,共10页
Exploring effective iridium(Ir)-based electrocatalysts with stable iridium centers is highly desirable for oxygen evolution reaction(OER).Herein,we regulated the incorporation manner of Ir in Co_(3)O_(4)support to sta... Exploring effective iridium(Ir)-based electrocatalysts with stable iridium centers is highly desirable for oxygen evolution reaction(OER).Herein,we regulated the incorporation manner of Ir in Co_(3)O_(4)support to stabilize the Ir sites for effective OER.When anchored on the surface of Co_(3)O_(4)in the form of Ir(OH)_6 species,the created Ir-OH-Co interface leads to a limited stability and poor acidic OER due to Ir leaching.When doped into Co_(3)O_(4)lattice,the analyses of X-ray absorption spectroscopy,in-situ Raman,and OER measurements show that the partially replacement of Co in Co_(3)O_(4)by Ir atoms inclines to cause strong electronic effect and activate lattice oxygen in the presence of Ir-O-Co interface,and simultaneously master the reconstruction effect to mitigate Ir dissolution,realizing the improved OER activity and stability in alkaline and acidic environments.As a result,Ir_(lat)@Co_(3)O_(4)with Ir loading of 3.67 wt%requires 294±4 mV/285±3 mV and 326±2 mV to deliver 10 mA cm^(-2)in alkaline(0.1 M KOH/1.0 M KOH)and acidic(0.5 M H_(2)SO_(4))solution,respectively,with good stability. 展开更多
关键词 Interface effect reconstruction Ir dissolution Ir-O-Co Oxygen evolution reaction
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部