In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuo...In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuous casting mold, the magnetic field in a NFC Mold were measured by Tesla meter of Model CT-3. The method of vector synthesis was adopted in the measurement of magnetic fields. The results showed that the magnetic field in the NFC Mold was composed of two main magnetic areas that were symmetrical. Although there was leaking magnetic flux between the lower surface of the upper pole and the upper surface of the lower pole on the sides, it was restrained by the main magnetic fields effectively. Therefore the NFC Mold was more preferably satisfied to be used in controlling the molten steel flow in continuous casting mold.展开更多
The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid ...The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement.展开更多
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc...Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.展开更多
In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare co...In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare comprehensively considered, and the governing equations are solved bysimplifying the boundary conditions. The axial magnetization of the sectorshapedpermanent magnets is accurately described in an algebraic form bythe parameters, which makes the physical meaning more explicit than thepurely mathematical expression in general series forms. The parameters of theBessel function are determined simply and the magnetic field distribution ofpermanent magnets and the air-gap is solved. Furthermore, the field solutionsare completely analytical, which provides convenience and satisfactoryaccuracy for modeling a series of electromagnetic performance parameters,such as the axial electromagnetic force density, axial electromagnetic force,and electromagnetic torque. The correctness and accuracy of the analyticalmodels are fully verified by three-dimensional finite element simulations and a15 kW prototype and the results of calculations, simulations, and experimentsunder three methods are highly consistent. The influence of several designparameters on magnetic field distribution and performance is studied and discussed.The results indicate that the modeling method proposed in this papercan calculate the magnetic field distribution and performance accurately andrapidly, which affords an important reference for the design and optimizationof axial-flux permanent magnet drivers.展开更多
Non-contact magnetic measurement method is an effective way to study the air arc behavior experimentally. One of the crucial techniques is to solve an inverse problem for the electromagnetic field. This study is devot...Non-contact magnetic measurement method is an effective way to study the air arc behavior experimentally. One of the crucial techniques is to solve an inverse problem for the electromagnetic field. This study is devoted to investigating different algorithms for this kind of inverse problem preliminarily, including the preconditioned conjugate gradient method, penalty function method and genetic algorithm. The feasibility of each algorithm is analyzed. It is shown that the preconditioned conjugate gradient method is valid only for few arc segments, the estimation accuracy of the penalty function method is dependent on the initial conditions, and the convergence of genetic algorithm should be studied further for more segments in an arc current.展开更多
The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno tim...The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno time has been shown to be temperature dependent. From the calculation it is evident that the Zeno time decreases with the increase of temperature. Moreover, the result restricts the Zeno time to a maximum limiting value, irrespective of how frequent the measurement process is.展开更多
The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hyste...The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hysteresis, of which the critical magnetic fields are temperature-dependent and show anisotropy. By using a pulsed high magnetic field up to 75 T, the magnetization behavior shows that the critical transition magnetic fields of spin- flip/flop shift to lower field regions with an increase in temperature. According to the magnetization curves, a complete magnetic phase diagram is depicted.展开更多
The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contai...The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.展开更多
We used data from 1960.0,1970.0,1980.0,1990.0,and 2000.0 to study the geomagnetic anomaly field over the Chinese mainland by using the three-dimensional Taylor polynomial(3DTP) and the surface spline(SS) models.To...We used data from 1960.0,1970.0,1980.0,1990.0,and 2000.0 to study the geomagnetic anomaly field over the Chinese mainland by using the three-dimensional Taylor polynomial(3DTP) and the surface spline(SS) models.To obtain the pure anomaly field,the main field and the induced field of the ionospheric and magnetospheric fields were removed from measured data.We also compared the SS model anomalies and the data obtained with Kriging interpolation(KI).The geomagnetic anomaly distribution over the mainland was analyzed based on the SS and 3DTP models by transferring all points from 1960.0-1990.0 to 2000.0.The results suggest that the total intensity F anomalies estimated based on the SS and KI for each year are basically consistent in distribution and intensity.The anomalous distributions in the X-,Y-,and Z-direction and F are mainly negative.The 3DTP model anomalies suggest that the intensity in the X-direction increases from-100 nT to 0 nT with longitude,whereas the intensity in the Y-direction decreases from 400 nT to 20 nT with longitude and over the eastern mainland is almost negative.The intensity in the Z-direction and F are very similar and in most areas it is about-50 nT and higher in western Tibet.The SS model anomalies overall reflect the actual distribution of the magnetic field anomalies;however,because of the uneven distribution of measurements,it yields several big anomalies.Owing to the added altitude term,the 3DTP model offers higher precision and is consistent with KI.展开更多
At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rota...At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design.展开更多
It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate t...It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.展开更多
The interference of carrier magnetic field to geomagnetic field has been a difficult problem for a long time,which influences on the deviation of navigation compass and the error of geomagnetic measurement. To increas...The interference of carrier magnetic field to geomagnetic field has been a difficult problem for a long time,which influences on the deviation of navigation compass and the error of geomagnetic measurement. To increase the geomagnetic measuring accuracy required for the geomagnetic matching localization,the strategy to eliminate the effect of connatural and induced magnetic fields of carrier on the geomagnetic measuring accuracy is investigated. The magnetic-dipole's magnetic field distributing theory is used to deduce the magnetic composition in the position of the sensor installed on the carrier. A geomagnetic measurement model is established by using the measuring data with the ideal sensor. Considering the magnetic disturbance of carrier and the error of sensor,a geomagnetic measuring compensation model is built. This model can be used to compensate the errors of carrier magnetic field and magnetic sensor in any case and its parameters have clear or specific physical meaning. The experimented results show that the model has higher geomagnetic measuring accuracy than that of others.展开更多
An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing rati...An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing ratios (M=1.5, 2) on the flow field are studied. The experimental results reveal the classical phenomena of the formation of kidney vortex pair and secondary flow in wake region behind the jet hole. And the changes of the kidney vortex pair and the wake at different locations away from the hole on the suction and pressure sides are also studied. Compared with the flow field in stationary cascade, there are centrifugal force and Coriolis force existing in the flow field of rotating turbine, and these forces bring the radial velocity in the jet flow. The effect of rotatien on the flow field of the pressure side is more distinct than that on the suction side from the measured flow fields in Y-Z plane and radial velocity contours. The increase of blowing ratio makes the kidney vortex pair and the secondary flow in the wake region stronger and makes the range of the wake region enlarged.展开更多
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the...Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly.展开更多
The intrinsic radial magnetic field(B r) in a tokamak is explored by the solution of the Grad–Shafranov equation in axisymmetric configurations through an expansion of the four terms of the magnetic surfaces. It ca...The intrinsic radial magnetic field(B r) in a tokamak is explored by the solution of the Grad–Shafranov equation in axisymmetric configurations through an expansion of the four terms of the magnetic surfaces. It can be inferred from the simulation results that at the core of the device, the tokamak should possess a three-dimensional magnetic field configuration, which could be reduced to a two-dimensional one when the radial position is greater than 0.6a. The radial magnetic field and the amzimuthal magnetic field have the same order of magnitude at the core of the device. These results can offer a reference for the analysis of the plasma instability, the property of the core plasma, and the magnetic field measurement.展开更多
According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magne...According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magnetic field levels close to power transmission lines at inhabited areas in Kuwait to see if current levels are safe and to establish a database of 50 Hz magnetic field levels at inhabited areas. Measurements were made, according to the international standard procedures in winter, spring, summer and fall, and three times of a day. Four inhabited areas were surveyed. Results provide us with an independent view of the levels in the vicinity of power lines and houses. Results show that the highest level is measured in the summer, reaching 115 mG while the minimum level is measured in the fall. We found that some houses were at less than 50 meters distance from the edge of the transmission lines. Some houses were, as close as 22 meters to the line. We found that levels at the entrance of houses and at outdoor parking areas were mostly higher than 4 mG.展开更多
The three-dimensional magnetic field of a permanent permanent (PM) disc-type generator is analyzed by the scalar potential method. In the analysis the permanent magnets are taken as magnetic charges. Hexahedron elemen...The three-dimensional magnetic field of a permanent permanent (PM) disc-type generator is analyzed by the scalar potential method. In the analysis the permanent magnets are taken as magnetic charges. Hexahedron element meshes are automatically generated by a prc-proccssing program developed by the authors. The flux densily is computed by a 3D scalar potential method program. Based on the linite elcment analysis the induced emf, current, armaturc reaction effects and electromagnetic torque of the disc machine are all calculated.展开更多
A new interpolation method for rotation and divergence free fields is presented. It is based on a suitable choice of a tricubic interpolation scheme and reaches an accuracy of third order in grid size (Δx). With the ...A new interpolation method for rotation and divergence free fields is presented. It is based on a suitable choice of a tricubic interpolation scheme and reaches an accuracy of third order in grid size (Δx). With the interpolation method it is possible to increase the accuracy with a factor of grid size/distance with respect to the trilinear interpolation method using exactly the same data points. Simulations for several distances of dipoles (r) to the interpolation area show that the maximum relative deviation is approximately 3(Δx/r)3 ppm.展开更多
Purpose: Exposure to a particular pattern of weak (~3 to 5 μT) magnetic fields produced by computer-generated point durations within three-dimensions completely dissolved malignant cancer cells but not healthy cells....Purpose: Exposure to a particular pattern of weak (~3 to 5 μT) magnetic fields produced by computer-generated point durations within three-dimensions completely dissolved malignant cancer cells but not healthy cells. Biomolecular analyses and confocal microscopy indicated excessive expansion followed by contraction contributed to the “explosion” of the cell. However, after months of replicable effects, the phenomenon slowly ceased. Considering the potency of the complete dissolution of cancer cell lines after 5 days of 6.5-hour daily exposures and the implications for human treatment, the potential source of the disappearance of the effect was pursued by summarizing all of the 50 experiments and assessing the likely etiologies. Materials and Methods: B16-BL6, MDAMB 231 and MCF7 malignant cells and HSG, a non-malignant cell line, were exposed to a sham-field condition or to a specific pattern of computer-generated magnetic fields produced from converting different voltages, each with point durations of 3 ms to 3-D magnetic fields. Conclusion: The specific serial presentation of the two field patterns (one frequency modulated;the other amplitude and frequency modulated) completely dissolved malignant cells but not normal cells within a “zone” within the exposure volume at the conjunction of the three planes of the applied magnetic fields. The affected cells underwent massive melanin production, expansion, contraction and “beading” of submembrane actin structures before fragmentation within this zone. However, this powerful all-or-none phenomenon may have been disrupted by moving the cells, excess mechanical agitation during exposure, or non-optimal point durations of the field parameters. Indirect effects from communication signals (WIFI) through line currents that operated the incubators could not be excluded.展开更多
Lorentz force velocimetry(LFV) is a noncontact technique for measuring electrically conducting fluids based on the principle of electromagnetic induction. This work aims to answer the open and essential question of wh...Lorentz force velocimetry(LFV) is a noncontact technique for measuring electrically conducting fluids based on the principle of electromagnetic induction. This work aims to answer the open and essential question of whether LFV can work properly under a surrounding external magnetic field(ExMF). Two types of Ex MFs with different magnetic intensities were examined: a magnetic field with a typical order of 0.4 T generated by a permanent magnet(PM) and another generated by an electromagnet(EM) on the order of 2 T. Two forces, including the magnetostatic force between the Ex MF and PM in the LFV, and the Lorentz force generated by the PM in LFV were measured and analyzed in the experiment. In addition,Ex MFs of varying strengths were added to the LFV, and the location of the LFV device in the iron cores of the EM was considered. The experimental outcomes demonstrate that it is possible for a LFV device to operate normally under a moderate Ex MF. However, the magnetostatic force will account for a high proportion of the measured force,thus inhibiting the normal LFV operation, if the Ex MF is too high.展开更多
基金the National Natural Science Foundation of China (Grant No. 59734080), the National Key Basic Research and Development Programme of China (Grant No. G1998061510) and the Project of National High Te
文摘In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuous casting mold, the magnetic field in a NFC Mold were measured by Tesla meter of Model CT-3. The method of vector synthesis was adopted in the measurement of magnetic fields. The results showed that the magnetic field in the NFC Mold was composed of two main magnetic areas that were symmetrical. Although there was leaking magnetic flux between the lower surface of the upper pole and the upper surface of the lower pole on the sides, it was restrained by the main magnetic fields effectively. Therefore the NFC Mold was more preferably satisfied to be used in controlling the molten steel flow in continuous casting mold.
基金Supported by the National Basic Research Program of China(No 2011CB921200)the Strategic Priority Research Program(B)of the Chinese Academy of Sciences under Grant (No XDB01030200)+1 种基金the National Natural Science Foundation of China(No11374290)the Fundamental Research Funds for the Central Universities and the Foundation for Authors of National Excellent Doctoral Dissertation of China
文摘The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement.
文摘Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.
基金supported by the National Natural Science Foundation of China under Grant[52077027]Liaoning Province Science and Technology Major Project[No.2020JH1/10100020].
文摘In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare comprehensively considered, and the governing equations are solved bysimplifying the boundary conditions. The axial magnetization of the sectorshapedpermanent magnets is accurately described in an algebraic form bythe parameters, which makes the physical meaning more explicit than thepurely mathematical expression in general series forms. The parameters of theBessel function are determined simply and the magnetic field distribution ofpermanent magnets and the air-gap is solved. Furthermore, the field solutionsare completely analytical, which provides convenience and satisfactoryaccuracy for modeling a series of electromagnetic performance parameters,such as the axial electromagnetic force density, axial electromagnetic force,and electromagnetic torque. The correctness and accuracy of the analyticalmodels are fully verified by three-dimensional finite element simulations and a15 kW prototype and the results of calculations, simulations, and experimentsunder three methods are highly consistent. The influence of several designparameters on magnetic field distribution and performance is studied and discussed.The results indicate that the modeling method proposed in this papercan calculate the magnetic field distribution and performance accurately andrapidly, which affords an important reference for the design and optimizationof axial-flux permanent magnet drivers.
基金supported by National Natural Science Foundation of China (No.50977072)the key project of Chinese Ministry of Education (No.109141)
文摘Non-contact magnetic measurement method is an effective way to study the air arc behavior experimentally. One of the crucial techniques is to solve an inverse problem for the electromagnetic field. This study is devoted to investigating different algorithms for this kind of inverse problem preliminarily, including the preconditioned conjugate gradient method, penalty function method and genetic algorithm. The feasibility of each algorithm is analyzed. It is shown that the preconditioned conjugate gradient method is valid only for few arc segments, the estimation accuracy of the penalty function method is dependent on the initial conditions, and the convergence of genetic algorithm should be studied further for more segments in an arc current.
文摘The Zeno time has been calculated for a metastable two-level atom tunneling through a interacting thermal magnetic field. The process of weak measurement has been utilized for the estimation of the timescale. Zeno time has been shown to be temperature dependent. From the calculation it is evident that the Zeno time decreases with the increase of temperature. Moreover, the result restricts the Zeno time to a maximum limiting value, irrespective of how frequent the measurement process is.
基金Supported by the National Natural Science Foundation of China under Grant No 11104091the Guangxi Key Laboratory of Information Materials of Guilin University of Electronic Technology under Grant No 1210908-05-K
文摘The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hysteresis, of which the critical magnetic fields are temperature-dependent and show anisotropy. By using a pulsed high magnetic field up to 75 T, the magnetization behavior shows that the critical transition magnetic fields of spin- flip/flop shift to lower field regions with an increase in temperature. According to the magnetization curves, a complete magnetic phase diagram is depicted.
文摘The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.
基金supported by the National Natural Science Foundation of China(No.41404053)Special Project for MeteoScientific Research in the Public Interest(No.GYHY201306073)+1 种基金Natural Science Foundation of Jiangsu Province(No.BK20140994),Natural Science Foundation of Higher Education Institutions of Jiangsu Province(No.14KJB170012)Training Program of Innovation and Entrepreneurship for Undergraduates of NUIST(No.201510300178)
文摘We used data from 1960.0,1970.0,1980.0,1990.0,and 2000.0 to study the geomagnetic anomaly field over the Chinese mainland by using the three-dimensional Taylor polynomial(3DTP) and the surface spline(SS) models.To obtain the pure anomaly field,the main field and the induced field of the ionospheric and magnetospheric fields were removed from measured data.We also compared the SS model anomalies and the data obtained with Kriging interpolation(KI).The geomagnetic anomaly distribution over the mainland was analyzed based on the SS and 3DTP models by transferring all points from 1960.0-1990.0 to 2000.0.The results suggest that the total intensity F anomalies estimated based on the SS and KI for each year are basically consistent in distribution and intensity.The anomalous distributions in the X-,Y-,and Z-direction and F are mainly negative.The 3DTP model anomalies suggest that the intensity in the X-direction increases from-100 nT to 0 nT with longitude,whereas the intensity in the Y-direction decreases from 400 nT to 20 nT with longitude and over the eastern mainland is almost negative.The intensity in the Z-direction and F are very similar and in most areas it is about-50 nT and higher in western Tibet.The SS model anomalies overall reflect the actual distribution of the magnetic field anomalies;however,because of the uneven distribution of measurements,it yields several big anomalies.Owing to the added altitude term,the 3DTP model offers higher precision and is consistent with KI.
基金Supported by China Coal Science and Technology Group Technology Innovation Fund Major Project(Grand No.2018ZD002)China Coal Science and Technology Group Technology Innovation Fund Youth Project(Grand No.2018-2-QN010)
文摘At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design.
基金supported in part by the National Natural Science Foundation of China(Grant No.92060114)in part by the Sichuan Science and Technology Program(Nos.2022YFS0524 and 2022YFG0044).
文摘It is known that eddy current effect has a great influence on magnetic flux leakage testing(MFL).Usually,contacttype encoder wheels are used to measure MFL testing speed to evaluate the effect and further compensate testing signals.This speed measurement method is complicated,and inevitable abrasion and occasional slippage will reduce the measurement accuracy.In order to solve this problem,based on eddy current effect due to the relative movement,a speed measurement method is proposed,which is contactless and simple.In the high-speed MFL testing,eddy current induced in the specimen will cause an obvious modification to the applied field.This modified field,which is measured by Hall sensor,can be utilized to reflect the moving speed.Firstly,the measurement principle is illustrated based on Faraday’s law.Then,dynamic finite element simulations are conducted to investigate the modified magnetic field distribution.Finally,laboratory experiments are performed to validate the feasibility of the proposed method.The results show that Bmz(r1)and Bmx(r2)have a linear relation with moving speed,which could be used as an alternative measurement parameter.
基金Sponsored by National Defence the 11th Five-Year Pre-research Project (51309060301)
文摘The interference of carrier magnetic field to geomagnetic field has been a difficult problem for a long time,which influences on the deviation of navigation compass and the error of geomagnetic measurement. To increase the geomagnetic measuring accuracy required for the geomagnetic matching localization,the strategy to eliminate the effect of connatural and induced magnetic fields of carrier on the geomagnetic measuring accuracy is investigated. The magnetic-dipole's magnetic field distributing theory is used to deduce the magnetic composition in the position of the sensor installed on the carrier. A geomagnetic measurement model is established by using the measuring data with the ideal sensor. Considering the magnetic disturbance of carrier and the error of sensor,a geomagnetic measuring compensation model is built. This model can be used to compensate the errors of carrier magnetic field and magnetic sensor in any case and its parameters have clear or specific physical meaning. The experimented results show that the model has higher geomagnetic measuring accuracy than that of others.
基金This project is supported by National Natural Science Foundation ofChina(No. 50406017)
文摘An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing ratios (M=1.5, 2) on the flow field are studied. The experimental results reveal the classical phenomena of the formation of kidney vortex pair and secondary flow in wake region behind the jet hole. And the changes of the kidney vortex pair and the wake at different locations away from the hole on the suction and pressure sides are also studied. Compared with the flow field in stationary cascade, there are centrifugal force and Coriolis force existing in the flow field of rotating turbine, and these forces bring the radial velocity in the jet flow. The effect of rotatien on the flow field of the pressure side is more distinct than that on the suction side from the measured flow fields in Y-Z plane and radial velocity contours. The increase of blowing ratio makes the kidney vortex pair and the secondary flow in the wake region stronger and makes the range of the wake region enlarged.
基金Project supported by the National Natural Science Foundation of China(Grant No.42074216).
文摘Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly.
基金Project supported by the Special Domestic Program of ITER,China(Grant No.2009GB105003)
文摘The intrinsic radial magnetic field(B r) in a tokamak is explored by the solution of the Grad–Shafranov equation in axisymmetric configurations through an expansion of the four terms of the magnetic surfaces. It can be inferred from the simulation results that at the core of the device, the tokamak should possess a three-dimensional magnetic field configuration, which could be reduced to a two-dimensional one when the radial position is greater than 0.6a. The radial magnetic field and the amzimuthal magnetic field have the same order of magnitude at the core of the device. These results can offer a reference for the analysis of the plasma instability, the property of the core plasma, and the magnetic field measurement.
文摘According to surveyed literature, there may be a health hazard associated with extremely low frequency magnetic fields. This study aims at presenting a recent survey of this literature. It also aims at measuring magnetic field levels close to power transmission lines at inhabited areas in Kuwait to see if current levels are safe and to establish a database of 50 Hz magnetic field levels at inhabited areas. Measurements were made, according to the international standard procedures in winter, spring, summer and fall, and three times of a day. Four inhabited areas were surveyed. Results provide us with an independent view of the levels in the vicinity of power lines and houses. Results show that the highest level is measured in the summer, reaching 115 mG while the minimum level is measured in the fall. We found that some houses were at less than 50 meters distance from the edge of the transmission lines. Some houses were, as close as 22 meters to the line. We found that levels at the entrance of houses and at outdoor parking areas were mostly higher than 4 mG.
文摘The three-dimensional magnetic field of a permanent permanent (PM) disc-type generator is analyzed by the scalar potential method. In the analysis the permanent magnets are taken as magnetic charges. Hexahedron element meshes are automatically generated by a prc-proccssing program developed by the authors. The flux densily is computed by a 3D scalar potential method program. Based on the linite elcment analysis the induced emf, current, armaturc reaction effects and electromagnetic torque of the disc machine are all calculated.
文摘A new interpolation method for rotation and divergence free fields is presented. It is based on a suitable choice of a tricubic interpolation scheme and reaches an accuracy of third order in grid size (Δx). With the interpolation method it is possible to increase the accuracy with a factor of grid size/distance with respect to the trilinear interpolation method using exactly the same data points. Simulations for several distances of dipoles (r) to the interpolation area show that the maximum relative deviation is approximately 3(Δx/r)3 ppm.
文摘Purpose: Exposure to a particular pattern of weak (~3 to 5 μT) magnetic fields produced by computer-generated point durations within three-dimensions completely dissolved malignant cancer cells but not healthy cells. Biomolecular analyses and confocal microscopy indicated excessive expansion followed by contraction contributed to the “explosion” of the cell. However, after months of replicable effects, the phenomenon slowly ceased. Considering the potency of the complete dissolution of cancer cell lines after 5 days of 6.5-hour daily exposures and the implications for human treatment, the potential source of the disappearance of the effect was pursued by summarizing all of the 50 experiments and assessing the likely etiologies. Materials and Methods: B16-BL6, MDAMB 231 and MCF7 malignant cells and HSG, a non-malignant cell line, were exposed to a sham-field condition or to a specific pattern of computer-generated magnetic fields produced from converting different voltages, each with point durations of 3 ms to 3-D magnetic fields. Conclusion: The specific serial presentation of the two field patterns (one frequency modulated;the other amplitude and frequency modulated) completely dissolved malignant cells but not normal cells within a “zone” within the exposure volume at the conjunction of the three planes of the applied magnetic fields. The affected cells underwent massive melanin production, expansion, contraction and “beading” of submembrane actin structures before fragmentation within this zone. However, this powerful all-or-none phenomenon may have been disrupted by moving the cells, excess mechanical agitation during exposure, or non-optimal point durations of the field parameters. Indirect effects from communication signals (WIFI) through line currents that operated the incubators could not be excluded.
基金supported by the National Natural Science Foundation of China(No.51374190)the Major Equipment Fund of Chinese Academy of Sciences(No.YZ201567)
文摘Lorentz force velocimetry(LFV) is a noncontact technique for measuring electrically conducting fluids based on the principle of electromagnetic induction. This work aims to answer the open and essential question of whether LFV can work properly under a surrounding external magnetic field(ExMF). Two types of Ex MFs with different magnetic intensities were examined: a magnetic field with a typical order of 0.4 T generated by a permanent magnet(PM) and another generated by an electromagnet(EM) on the order of 2 T. Two forces, including the magnetostatic force between the Ex MF and PM in the LFV, and the Lorentz force generated by the PM in LFV were measured and analyzed in the experiment. In addition,Ex MFs of varying strengths were added to the LFV, and the location of the LFV device in the iron cores of the EM was considered. The experimental outcomes demonstrate that it is possible for a LFV device to operate normally under a moderate Ex MF. However, the magnetostatic force will account for a high proportion of the measured force,thus inhibiting the normal LFV operation, if the Ex MF is too high.