For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ...For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.展开更多
Energy metabolism is fundamental for life.It encompasses the utilization of carbohydrates,lipids,and proteins for internal processes,while aberrant energy metabolism is implicated in many diseases.In the present study...Energy metabolism is fundamental for life.It encompasses the utilization of carbohydrates,lipids,and proteins for internal processes,while aberrant energy metabolism is implicated in many diseases.In the present study,using three-dimensional(3D)printing from polycarbonate via fused deposition modeling,we propose a multi-nuclear radiofrequency(RF)coil design with integrated 1H birdcage and interchangeable X-nuclei(^(2)H,^(13)C,^(23)Na,and^(31)P)single-loop coils for magnetic resonance imaging(MRI)/magnetic resonance spectroscopy(MRS).The single-loop coil for each nucleus attaches to an arc bracket that slides unrestrictedly along the birdcage coil inner surface,enabling convenient switching among various nuclei and animal handling.Compared to a commercial 1H birdcage coil,the proposed 1H birdcage coil exhibited superior signal-excitation homogeneity and imaging signal-to-noise ratio(SNR).For X-nuclei study,prominent peaks in spectroscopy for phantom solutions showed excellent SNR,and the static and dynamic peaks of in vivo spectroscopy validated the efficacy of the coil design in structural imaging and energy metabolism detection simultaneously.展开更多
基金Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200)the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
文摘For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
基金This work was supported in part by the STI 2030-Major Projects(No.2021ZD0200401)the National Key Research and Development Program of China(No.2018YFA0701400)+3 种基金the National Natural Science Foundation of China(Nos.52277232,52293424,81701774,and 61771423)the Fundamental Research Funds for the Central Universities(Nos.226-2022-00136 and 226-2023-00125)the Zhejiang Provincial Natural Science Foundation of China(No.LR23E070001),the Key R&D Program of Jiangsu Province(No.BE2022049)the Key-Area R&D Program of Guangdong Province(No.2018B030333001),China.
文摘Energy metabolism is fundamental for life.It encompasses the utilization of carbohydrates,lipids,and proteins for internal processes,while aberrant energy metabolism is implicated in many diseases.In the present study,using three-dimensional(3D)printing from polycarbonate via fused deposition modeling,we propose a multi-nuclear radiofrequency(RF)coil design with integrated 1H birdcage and interchangeable X-nuclei(^(2)H,^(13)C,^(23)Na,and^(31)P)single-loop coils for magnetic resonance imaging(MRI)/magnetic resonance spectroscopy(MRS).The single-loop coil for each nucleus attaches to an arc bracket that slides unrestrictedly along the birdcage coil inner surface,enabling convenient switching among various nuclei and animal handling.Compared to a commercial 1H birdcage coil,the proposed 1H birdcage coil exhibited superior signal-excitation homogeneity and imaging signal-to-noise ratio(SNR).For X-nuclei study,prominent peaks in spectroscopy for phantom solutions showed excellent SNR,and the static and dynamic peaks of in vivo spectroscopy validated the efficacy of the coil design in structural imaging and energy metabolism detection simultaneously.