With a concrete pavement slab prestressed, its load carrying capacity can be significantly increased; thus a thinner slab may be used for the same loading. Prestressing modify the structural behavior of the pavement ...With a concrete pavement slab prestressed, its load carrying capacity can be significantly increased; thus a thinner slab may be used for the same loading. Prestressing modify the structural behavior of the pavement slab and there is a greater resistance to impact, vibration and overloading. This paper discusses the major design considerations necessary in the successful construction of prestressed concrete pavements and presents a design procedure developed to predict the compressive stress due to prestressing in the pavements at early stage, during service and after cracking. Variation in the approach for repetitive and nonrepetitive loads is clearly distinguished. Check on the recovery after cracking for overloading in prestressed pavements is also needed. Finally, a design example is illustrated the application of the approach developed.展开更多
A bidirectional ribbed concrete beam slab structure was widly adopted for the upper space of industrial buildings.To maintain ample space and minimize the presence of conventional columns,a bidirectional prestressed c...A bidirectional ribbed concrete beam slab structure was widly adopted for the upper space of industrial buildings.To maintain ample space and minimize the presence of conventional columns,a bidirectional prestressed concrete beam is often employed.The intersection node of the prestressed concrete frame beam column was characterized by a high density of steel reinforcement,significant structural loads,and complex construction requirements.To ensure the quality,safety,and progress of prestressed frame beamcolumn intersection nodes during construction,this article proposed a new technology for constructing such nodes,which includes setting the tensioning and haunching ends of nodes at different positions,using ABAQUS finite element software to optimize the design of cross-sectional dimensions,conducting stress analysis simulations.展开更多
Normal strength prestressed concrete I-girders are commonly used as the primary superstructure components in highway bridges. However, shear design guidelines for high strength PC girders are not available in the curr...Normal strength prestressed concrete I-girders are commonly used as the primary superstructure components in highway bridges. However, shear design guidelines for high strength PC girders are not available in the current structural codes. Recently, ten 7.62 m (25 feet) long girders made with high strength concrete were designed, cast, and tested at the University of Houston (UH) to study the ultimate shear strength and the shear concrete contribution (Vc) as a function of concrete strength (f'c). A simple semi-empirical set of equations was developed based on the test results to predict the ultimate shear strength of prestressed concrete I-girders. The UH-developed set of equations is a function of concrete strength (√f'c), web area (bwd), shear span to effective depth ratio (a/d), and percentage of transverse steel (Pt). The proposed UH-Method was found to accurately predict the ultimate shear strength of PC girders with concrete strength up to 117 MPa (17000 psi) ensuring satisfactory ductility. The UH-Method was found to be not as overly conservative as the ACI-318 (2011) code provisions, and also not to overestimate the ultimate shear strength of high strength PC girders as the AASHTO LRFD (2010) code provisions. Moreover, the proposed UH-Method was found fairly accurate and not exceedingly conservative in predicting the concrete contribution to shear for concrete strength up to 117 MPa (17000 psi).展开更多
The ultra-high-performance concrete(UHPC)and fiber-reinforced polymer(FRP)are well-accepted high-performance materials in the field of civil engineering.The combination of these advanced materials could contribute to ...The ultra-high-performance concrete(UHPC)and fiber-reinforced polymer(FRP)are well-accepted high-performance materials in the field of civil engineering.The combination of these advanced materials could contribute to improvement of structural performance and corrosion resistance.Unfortunately,only limited studies are available for shear behavior of UHPC beams reinforced with FRP bars,and few suggestions exist for prediction methods for shear capacity.This paper presents an experimental investigation on the shear behavior of UHPC beams reinforced with glass FRP(GFRP)and prestressed with external carbon FRP(CFRP)tendons.The failure mode of all specimens with various shear span to depth ratios from 1.7 to 4.5 was diagonal tension failure.The shear span to depth ratio had a significant influence on the shear capacity,and the effective prestressing stress affected the crack propagation.The experimental results were then applied to evaluate the equations given in different codes/recommendations for FRPreinforced concrete structures or UHPC structures.The comparison results indicate that NF P 18-710 and JSCE CES82 could appropriately estimate shear capacity of the slender specimens with a shear span to depth ratio of 4.5.Further,a new shear design equation was proposed to take into account the effect of the shear span to depth ratio and the steel fiber content on shear capacity.展开更多
文摘With a concrete pavement slab prestressed, its load carrying capacity can be significantly increased; thus a thinner slab may be used for the same loading. Prestressing modify the structural behavior of the pavement slab and there is a greater resistance to impact, vibration and overloading. This paper discusses the major design considerations necessary in the successful construction of prestressed concrete pavements and presents a design procedure developed to predict the compressive stress due to prestressing in the pavements at early stage, during service and after cracking. Variation in the approach for repetitive and nonrepetitive loads is clearly distinguished. Check on the recovery after cracking for overloading in prestressed pavements is also needed. Finally, a design example is illustrated the application of the approach developed.
基金Funded by the Nantong Science and Technology Plan Project(No.JC2021172)the Cyan and Blue Project of Universities in Jiangsu Province。
文摘A bidirectional ribbed concrete beam slab structure was widly adopted for the upper space of industrial buildings.To maintain ample space and minimize the presence of conventional columns,a bidirectional prestressed concrete beam is often employed.The intersection node of the prestressed concrete frame beam column was characterized by a high density of steel reinforcement,significant structural loads,and complex construction requirements.To ensure the quality,safety,and progress of prestressed frame beamcolumn intersection nodes during construction,this article proposed a new technology for constructing such nodes,which includes setting the tensioning and haunching ends of nodes at different positions,using ABAQUS finite element software to optimize the design of cross-sectional dimensions,conducting stress analysis simulations.
文摘Normal strength prestressed concrete I-girders are commonly used as the primary superstructure components in highway bridges. However, shear design guidelines for high strength PC girders are not available in the current structural codes. Recently, ten 7.62 m (25 feet) long girders made with high strength concrete were designed, cast, and tested at the University of Houston (UH) to study the ultimate shear strength and the shear concrete contribution (Vc) as a function of concrete strength (f'c). A simple semi-empirical set of equations was developed based on the test results to predict the ultimate shear strength of prestressed concrete I-girders. The UH-developed set of equations is a function of concrete strength (√f'c), web area (bwd), shear span to effective depth ratio (a/d), and percentage of transverse steel (Pt). The proposed UH-Method was found to accurately predict the ultimate shear strength of PC girders with concrete strength up to 117 MPa (17000 psi) ensuring satisfactory ductility. The UH-Method was found to be not as overly conservative as the ACI-318 (2011) code provisions, and also not to overestimate the ultimate shear strength of high strength PC girders as the AASHTO LRFD (2010) code provisions. Moreover, the proposed UH-Method was found fairly accurate and not exceedingly conservative in predicting the concrete contribution to shear for concrete strength up to 117 MPa (17000 psi).
基金The authors sincerely appreciate the funding support from the National Natural Science Foundation of China(Grant No.51938012).The authors would sincerely acknowledge Miss Wei Zhang and Dr.Wang Qiwu for their language editing and insightful comments.
文摘The ultra-high-performance concrete(UHPC)and fiber-reinforced polymer(FRP)are well-accepted high-performance materials in the field of civil engineering.The combination of these advanced materials could contribute to improvement of structural performance and corrosion resistance.Unfortunately,only limited studies are available for shear behavior of UHPC beams reinforced with FRP bars,and few suggestions exist for prediction methods for shear capacity.This paper presents an experimental investigation on the shear behavior of UHPC beams reinforced with glass FRP(GFRP)and prestressed with external carbon FRP(CFRP)tendons.The failure mode of all specimens with various shear span to depth ratios from 1.7 to 4.5 was diagonal tension failure.The shear span to depth ratio had a significant influence on the shear capacity,and the effective prestressing stress affected the crack propagation.The experimental results were then applied to evaluate the equations given in different codes/recommendations for FRPreinforced concrete structures or UHPC structures.The comparison results indicate that NF P 18-710 and JSCE CES82 could appropriately estimate shear capacity of the slender specimens with a shear span to depth ratio of 4.5.Further,a new shear design equation was proposed to take into account the effect of the shear span to depth ratio and the steel fiber content on shear capacity.