期刊文献+
共找到6,056篇文章
< 1 2 250 >
每页显示 20 50 100
Spin wave resonance frequency in bilayer ferromagnetic films with the biquadratic exchange interaction
1
作者 Xiaojie Zhang Yuting Wang +3 位作者 Yanqiu Chang Huan Wang Jianhong Rong Guohong Yun 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期607-613,共7页
The dependences of spin wave resonance(SWR)frequency on the surface anisotropy field,interface exchange coupling,symmetry,biquadratic exchange(BQE)interaction,film thickness,and the external magnetic field in bilayer ... The dependences of spin wave resonance(SWR)frequency on the surface anisotropy field,interface exchange coupling,symmetry,biquadratic exchange(BQE)interaction,film thickness,and the external magnetic field in bilayer ferromagnetic films are theoretically analyzed by employing the linear spin wave approximation and Green’s function method.A remarkable increase of SWR frequency,except for energetically lower two modes,can be obtained in our model that takes the BQE interaction into account.Again,the effect of the external magnetic field on SWR frequency can be increased by increasing the biquadratic to interlayer exchange ratio.It has been identified that the BQE interaction is of utmost importance in improving the SWR frequency of the bilayer ferromagnetic films.In addition,for bilayer ferromagnetic films,the frequency gap between the energetically highest mode and lowest mode is found to increase by increasing the biquadratic to interlayer exchange ratio and film thickness and destroying the symmetry of the system.These results can be used to improve the understanding of magnetic properties in bilayer ferromagnetic films and thus may have prominent implications for future magnetic devices. 展开更多
关键词 SPIN WAVE resonance frequency biquadratic EXCHANGE interaction interface EXCHANGE coupling surface ANISOTROPY
下载PDF
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
2
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
下载PDF
Seismic evaluation of frequency influence and resonant behavior for lead rubber bearing isolated rigid rectangular liquid tanks
3
作者 Jyoti Ranjan Barik Kishore Chandra Biswal 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第4期973-994,共22页
The seismic behavior of a partially filled rigid rectangular liquid tank is investigated under short-and longduration ground motions.A finite element model is developed to analyze the liquid domain by using four-noded... The seismic behavior of a partially filled rigid rectangular liquid tank is investigated under short-and longduration ground motions.A finite element model is developed to analyze the liquid domain by using four-noded quadrilateral elements.The competency of the model is verified with the available results.Parametric studies are conducted for the dynamic parameters of the base-isolated tank,using a lead rubber bearing to evaluate the optimum damping and time period of the isolator.The application of base isolation has reduced the total and impulsive hydrodynamic components of pressure by 80 to 90 percent,and base shear by 15 to 95 percent,depending upon the frequency content and duration of the considered earthquakes.The sloshing amplitude of the base-isolated tank is reduced by 18 to 94 percent for most of the short-duration earthquakes,while it is increased by 17 to 60 percent for the majority of the long-duration earthquakes.Furthermore,resonance studies are carried out through a long-duration harmonic excitation to obtain the dynamic behavior of non-isolated and isolated tanks,using a nonlinear sloshing model.The seismic responses of the base-isolated tank are obtained as higher when the excitation frequency matches the fundamental sloshing frequency rather than the isolator frequency. 展开更多
关键词 lead rubber bearing frequency domain resonant inputs long-duration excitation
下载PDF
A low-noise X-band microwave source with digital automatic frequency control for electron paramagnetic resonance spectroscopy
4
作者 贺羽 康润琪 +1 位作者 石致富 荣星 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期46-51,共6页
We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital auto... We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital automatic frequency control circuit can be flexibly configured for different experimental conditions,such as the input powers or the quality factors of the resonator.The configurability makes the microwave source universally compatible and greatly extends its application.To demonstrate the ability of adapting to various experimental conditions,the microwave source is tested by varying the input powers and the quality factors of the resonator.A satisfactory phase noise as low as-135 d Bc/Hz at 100-k Hz offset from the center frequency is achieved,due to the use of a phase-locked dielectric resonator oscillator and a direct digital synthesizer.Continuous-wave electron paramagnetic resonance experiments are conducted to examine the performance of the microwave source.The outstanding performance shows a prospect of wide applications of the microwave source in numerous fields of science. 展开更多
关键词 electron paramagnetic resonance X-BAND microwave source automatic frequency control
下载PDF
Modal Frequency Prediction of Chladni Patterns Using Machine Learning
5
作者 Atul Kumar K. P. Wani 《Open Journal of Acoustics》 2024年第1期1-16,共16页
The introduction of machine learning (ML) in the research domain is a new era technique. The machine learning algorithm is developed for frequency predication of patterns that are formed on the Chladni plate and focus... The introduction of machine learning (ML) in the research domain is a new era technique. The machine learning algorithm is developed for frequency predication of patterns that are formed on the Chladni plate and focused on the application of machine learning algorithms in image processing. In the Chladni plate, nodes and antinodes are demonstrated at various excited frequencies. Sand on the plate creates specific patterns when it is excited by vibrations from a mechanical oscillator. In the experimental setup, a rectangular aluminum plate of 16 cm x 16 cm and 0.61 mm thickness was placed over the mechanical oscillator, which was driven by a sine wave signal generator. 14 Chladni patterns are obtained on a Chladni plate and validation is done with modal analysis in Ansys. For machine learning, a large number of data sets are required, as captured around 200 photos of each modal frequency and around 3000 photos with a camera of all 14 Chladni patterns for supervised learning. The current model is written in Python language and model has one convolution layer. The main modules used in this are Tensor Flow Keras, NumPy, CV2 and Maxpooling. The fed reference data is taken for 14 frequencies between 330 Hz to 3910 Hz. In the model, all the images are converted to grayscale and canny edge detected. All patterns of frequencies have an almost 80% - 99% correlation with test sample experimental data. This approach is to form a directory of Chladni patterns for future reference purpose in real-life application. A machine learning algorithm can predict the resonant frequency based on the patterns formed on the Chladni plate. 展开更多
关键词 Chaldni Pattern Modal Analysis Machine Learning resonant frequency Image Processing
下载PDF
Application of Three-Dimensional Magnetic Resonance Imaging in the Diagnosis of Perianal Abscess 被引量:5
6
作者 Fang Zhang Shan Xiong +1 位作者 Sibin Liu Peng Xia 《Health》 2019年第5期535-545,共11页
Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investiga... Perianal abscess is a common disease in anorectal surgery. If the diagnosis is not clear and the cure is thoroughly cleared, the recurrence and spread of anal fistula will cause life-long pain. Objective: To investigate the application of 3.0T MRI 3D CUBE T2WI lipid suppression sequence in the diagnosis of perianal abscess. Methods: Thirty-six patients with perianal abscess confirmed by operation were examined with 2D T2WI and 3D CUBE T2WI lipid suppression sequences before operation. Two imaging techniques were evaluated to show the types of perianal abscess, the number of abscesses, the number of internal orifices of abscess, and the number of fistula branches with anal fistula in abscess. Results: Among 36 cases of perianal abscess, there were 5 cases of anal subcutaneous abscess, 12 cases of ischiorectal space abscess (8 cases complicated with anal fistula), 6 cases of posterior anal space abscess, 5 cases of anal sphincter abscess (3 cases complicated with anal fistula), 2 cases of high intermuscular abscess, 2 cases of rectal submucosal abscess, 3 cases of complex abscess (3 cases complicated with anal fistula), 1 case of misdiagnosis, 2D T2WI lipid suppression sequence and 3D CUBE T2WI suppression. The accuracy of lipid sequence abscess typing was 80.6% (29/36) and 88.9% (32/36), respectively, with no significant difference (P > 0.05). Thirty-six patients were surgically diagnosed as having 32 internal orifices, 68.8% (22/32) and 93.8% (30/32) of 2D T2WI and 3D CUBE T2WI lipid-suppressing sequences, respectively, with significant difference (P Conclusion: 3D CUBE T2WI lipid suppression sequence is superior to 2D T2WI lipid suppression sequence in the classification of perianal abscess, the number of internal orifices of abscess and the number of fistula branches of abscess complicated with anal fistula. It can also determine the number of internal orifices of abscess complicated with anal fistula, the number of fistula branches, the shape of primary and branch fistula and the relationship among pelvic floor muscle tissues. It can provide more accurate images for preoperative and intraoperative clinical surgery. 展开更多
关键词 Magnetic resonance IMAGING three-dimensional IMAGING PERIANAL ABSCESS
下载PDF
Stochastic resonance of coupled time-delayed system with fluctuation of mass and frequency and its application in bearing fault diagnosis 被引量:3
7
作者 ZHANG Gang WANG Hui ZHANG Tian-qi 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第9期2931-2946,共16页
The stochastic resonance behavior of coupled stochastic resonance(SR)system with time-delay under mass and frequency fluctuations was studied.Firstly,the approximate system model of the time-delay system was obtained ... The stochastic resonance behavior of coupled stochastic resonance(SR)system with time-delay under mass and frequency fluctuations was studied.Firstly,the approximate system model of the time-delay system was obtained by the theory of small time-delay approximation.Then,the random average method and Shapiro-Loginov algorithm were used to calculate the output amplitude ratio of the two subsystems.The simulation analysis shows that increasing the time-delay and the input signal amplitude appropriately can improve the output response of the system.Finally,the system is applied to bearing fault diagnosis and compared with the stochastic resonance system with random mass and random frequency.The experimental results show that the coupled SR system taking into account the actual effect of time-delay and couple can more effectively extract the frequency of the fault signal,and thus realizing the diagnosis of the fault signal,which has important engineering application value. 展开更多
关键词 stochastic resonance bearing fault diagnosis the fluctuation of mass and frequency coupled time-delayed system
下载PDF
Stochastic resonance in a single-mode laser driven by frequency modulated signal and coloured noises 被引量:1
8
作者 金国祥 张良英 曹力 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第3期952-957,共6页
By adding frequency modulated signals to the intensity equation of gain noise model of the single-mode laser driven by two coloured noises which are correlated, this paper uses the linear approximation method to calcu... By adding frequency modulated signals to the intensity equation of gain noise model of the single-mode laser driven by two coloured noises which are correlated, this paper uses the linear approximation method to calculate the power spectrum and signal-to-noise ratio (SNR) of the laser intensity. The results show that the SNR appears typical stochastic resonance with the variation of intensity of the pump noise and quantum noise. As the amplitude of a modulated signal has effects on the SNR, it shows suppression, monotone increasing, stochastic resonance, and multiple stochastic resonance with the variation of the frequency of a carrier signal and modulated signal. 展开更多
关键词 Gaussian coloured noise single-mode laser stochastic resonance frequency modulated signal
下载PDF
On the Downshift of Wave Frequency for Bragg Resonance 被引量:2
9
作者 PENG Ji TAO Ai-feng +2 位作者 FAN Jun ZHENG Jin-hai LIU Yu-ming 《China Ocean Engineering》 SCIE EI CSCD 2022年第1期76-85,共10页
For surface gravity waves propagating over a horizontal bottom that consists of a patch of sinusoidal ripples,strong wave reflection occurs under the Bragg resonance condition.The critical wave frequency,at which the ... For surface gravity waves propagating over a horizontal bottom that consists of a patch of sinusoidal ripples,strong wave reflection occurs under the Bragg resonance condition.The critical wave frequency,at which the peak reflection coefficient is obtained,has been observed in both physical experiments and direct numerical simulations to be downshifted from the well-known theoretical prediction.It has long been speculated that the downshift may be attributed to higher-order rippled bottom and free-surface boundary effects,but the intrinsic mechanism remains unclear.By a regular perturbation analysis,we derive the theoretical solution of frequency downshift due to third-order nonlinear effects of both bottom and free-surface boundaries.It is found that the bottom nonlinearity plays the dominant role in frequency downshift while the free-surface nonlinearity actually causes frequency upshift.The frequency downshift/upshift has a quadratic dependence in the bottom/free-surface steepness.Polychromatic bottom leads to a larger frequency downshift relative to the monochromatic bottom.In addition,direct numerical simulations based on the high-order spectral method are conducted to validate the present theory.The theoretical solution of frequency downshift compares well with the numerical simulations and available experimental data. 展开更多
关键词 gravity surface wave Bragg resonance frequency downshift regular perturbation analysis
下载PDF
Frequency modulated weak signal detection based on stochastic resonance and genetic algorithm 被引量:17
10
作者 XING Hongyan LU Chunxia ZHANG Qiang 《Instrumentation》 2016年第1期41-49,共9页
Stochastic resonance system is subject to the restriction of small frequency parameter in weak signal detection,in order to solve this problem,a frequency modulated weak signal detection method based on stochastic res... Stochastic resonance system is subject to the restriction of small frequency parameter in weak signal detection,in order to solve this problem,a frequency modulated weak signal detection method based on stochastic resonance and genetic algorithm is presented in this paper. The frequency limit of stochastic resonance is eliminated by introducing carrier signal,which is multiplied with the measured signal to be injected in the stochastic resonance system,meanwhile,using genetic algorithm to optimize the carrier signal frequency,which determine the generated difference-frequency signal in the lowfrequency range,so as to achieve the stochastic resonance weak signal detection. Results showthat the proposed method is feasible and effective,which can significantly improve the output SNR of stochastic resonance,in addition,the system has the better self-adaptability,according to the operation result and output phenomenon,the unknown frequency of the signal to be measured can be obtained,so as to realize the weak signal detection of arbitrary frequency. 展开更多
关键词 stochastic resonance two-dimension DUFFING OSCILLATOR frequency MODULATED GENETIC algorithm
下载PDF
Magnetic resonance imaging-three-dimensional printing technology fabricates customized scaffolds for brain tissue engineering 被引量:1
11
作者 Feng Fu Zhe Qin +10 位作者 Chao Xu Xu-yi Chen Rui-xin Li Li-na Wang Ding-wei Peng Hong-tao Sun Yue Tu Chong Chen Sai Zhang Ming-liang Zhao Xiao-hong Li 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第4期614-622,共9页
Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to crea... Conventional fabrication methods lack the ability to control both macro- and micro-structures of generated scaffolds. Three-dimensional printing is a solid free-form fabrication method that provides novel ways to create customized scaffolds with high precision and accuracy. In this study, an electrically controlled cortical impactor was used to induce randomized brain tissue defects. The overall shape of scaffolds was designed using rat-specific anatomical data obtained from magnetic resonance imaging, and the internal structure was created by computer- aided design. As the result of limitations arising from insufficient resolution of the manufacturing process, we magnified the size of the cavity model prototype five-fold to successfully fabricate customized collagen-chitosan scaffolds using three-dimensional printing. Results demonstrated that scaffolds have three-dimensional porous structures, high porosity, highly specific surface areas, pore connectivity and good internal characteristics. Neural stem cells co-cultured with scaffolds showed good viability, indicating good biocompatibility and biodegradability. This technique may be a promising new strategy for regenerating complex damaged brain tissues, and helps pave the way toward personalized medicine. 展开更多
关键词 nerve regeneration three-dimensional printing traumatic brain injury tissue engineering scaffolds magnetic resonance imaging COLLAGEN CHITOSAN MIMICS neural regeneration
下载PDF
Three-dimensional reconstructed magnetic resonance scans:Accuracy in identifying and defining knee meniscal tears 被引量:1
12
作者 Neil Kruger Eugene Mc Nally +3 位作者 Sami Al-Ali Raj Rout Jonathan L Rees Andrew J Price 《World Journal of Orthopedics》 2016年第11期731-737,共7页
AIM To determine whether three-dimensional(3D) reconstruction from conventional magnetic resonance imaging(MRI) is able to accurately detect a meniscal tear, and define the configuration.METHODS Thirty-three patients&... AIM To determine whether three-dimensional(3D) reconstruction from conventional magnetic resonance imaging(MRI) is able to accurately detect a meniscal tear, and define the configuration.METHODS Thirty-three patients' 3T MRI scan data were collected and sagittal uni-planar 3D reconstructions performed from the preoperative MRI. There were 24 meniscal tears in 24 patients, and nine controls. All patients had arthroscopic corroboration of MRI findings. Two independent observers prospectively reported on all 33 reconstructions. Meniscal tear presence or absence was noted, and tear configuration subsequently categorised as either radial, bucket-handle, parrot beak, horizontal or complex.RESULTS Identification of control menisci or meniscal tear presence was excellent(Accuracy: observer 1 = 90.9%; observer 2 = 81.8%). Of the tear configurations, bucket handle tears were accurately identified(Accuracy observer 1 and 2 = 80%). The remaining tear configurations were notaccurately discernable.CONCLUSION Uni-planar 3D reconstruction from 3T MRI knee scan sequences are useful in identifying normal menisci and menisci with bucket-handle tears. Advances in MRI sequencing and reconstruction software are awaited for accurate identification of the remaining meniscal tear configurations. 展开更多
关键词 KNEE MENISCUS ARTHROSCOPY Magnetic resonance imaging three-dimensional reconstruction Materialise Interactive Medical Control System TEAR
下载PDF
Diffusion Coefficient at Resonance Frequency as Applied to n+/p/p+ Silicon Solar Cell Optimum Base Thickness Determination 被引量:1
13
作者 Amadou Mar Ndiaye Sega Gueye +6 位作者 Mame Faty Mbaye Fall Gora Diop Amadou Mamour Ba Mamadou Lamine Ba Ibrahima Diatta Lemrabott Habiboullah Gregoire Sissoko 《Journal of Electromagnetic Analysis and Applications》 2020年第10期145-158,共14页
The modelling and determination of the geometric parameters of a solar cell are important data, which influence the evaluation of its performance under specific operating conditions, as well as its industrial developm... The modelling and determination of the geometric parameters of a solar cell are important data, which influence the evaluation of its performance under specific operating conditions, as well as its industrial development for a low cost. In this work, an n+/p/p+ crystalline silicon solar cell is studied under monochromatic illumination in modulation and placed in a constant magnetic field. The minority carriers’ diffusion coefficient (<em>D</em>(<em>ω</em>, <em>B</em>), in the (<em>p</em>) base leads to maximum values (Dmax) at resonance frequencies (<em>ωr</em>). These values are used in expressions of AC minority carriers recombination velocity (Sb(Dmax, H)) in the rear of the base, to extract the optimum thickness while solar cell is subjected to these specific conditions. Optimum thickness modelling relationships, depending respectively on Dmax, <em>ωr</em> and <em>B</em>, are then established, and will be data for industrial development of low-cost solar cells for specific use. 展开更多
关键词 Silicon Solar Cell resonance frequency Magnetic Field Recombination Velocity Base Thickness
下载PDF
Three-dimensional time-of-flight magnetic resonance angiography combined with high resolution T2-weighted imaging in preoperative evaluation of microvascular decompression 被引量:1
14
作者 Chen Liang Ling Yang +2 位作者 Bin-Bin Zhang Shi-Wen Guo Rui-Chun Li 《World Journal of Clinical Cases》 SCIE 2022年第34期12594-12604,共11页
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H... BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD. 展开更多
关键词 three-dimensional time-of-flight magnetic resonance angiography High resolution T2 weighted imaging Neurovascular compression Microvascular decompression META-ANALYSIS
下载PDF
Influence of surface micro-beams with large deflection on the resonance frequency of a quartz crystal resonator in thickness-shear mode vibrations 被引量:1
15
作者 Chi Luo Jiemin Xie Yuantai Hu 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2017年第2期72-75,共4页
We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account t... We study the dynamic behavior of a quartz crystal resonator (QCR) in thickness-shear vibrations with the upper surface covered by an array of micro-beams (MBs) under large deflection. Through taking into account the continuous conditions of shear force and bending moment at the interface of MBs/resonator, dependences of frequency shift of the compound QCR system versus material parameter and geometrical parameter are illustrated in detail for nonlinear and linear vibrations. It is found that the frequency shift produces a little right (left) translation for increasing elastic modulus (length/radius ratio) of MBs. Moreover, the frequency right (left) translation distance caused by nonlinear deformation becomes more serious in the second-order mode than in the first-order one, 展开更多
关键词 Quartz crystal resonator Nonlinear deformation Micro-beams frequency shift
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
16
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location Main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
Combined spatial frequency spectroscopy analysis with visible resonance Raman for optical biopsy of human brain metastases of lung cancers 被引量:1
17
作者 Yan Zhou Cheng-Hui Liu +8 位作者 Yang Pu Binlin Wu Thien An Nguyen Gangge Cheng Lixin Zhou Ke Zhu Jun Chen Qingbo Li Robert R.Alfano 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第2期93-104,共12页
The purpose of this study is to examine optical spatial frequency spectroscopy analysis(SFSA)combined with visible resonance Raman(VRR)spectroscopic method,for thefirst time,to discriminate human brain metastases of l... The purpose of this study is to examine optical spatial frequency spectroscopy analysis(SFSA)combined with visible resonance Raman(VRR)spectroscopic method,for thefirst time,to discriminate human brain metastases of lung cancers adenocarcinoma(ADC)and squamous cell carcinoma(SCC)from normal tissues.A total of 31 label-free micrographic images of three type of brain tissues were obtained using a confocal micro-Raman spectroscopic system.VRR spectra of the corresponding samples were synchronously collected using excitation wavelength of 532 nm from the same sites of the tissues.Using SFSA method,the difference in the randomness of spatial frequency structures in the micrograph images was analyzed using Gaussian functionfitting.The standard deviations,calculated from the spatial frequencies of the micrograph images were then analyzed using support vector machine(SVM)classifier.The key VRR biomolecularfingerprints of carotenoids,tryptophan,amide II,lipids and proteins(methylene/methyl groups)were also analyzed using SVM classifier.All three types of brain tissues were identified with high accuracy in the two approaches with high correlation.The results show that SFSA–VRR can potentially be a dual-modal method to provide new criteria for identifying the three types of human brain tissues,which are on-site,real-time and label-free and may improve the accuracy of brain biopsy. 展开更多
关键词 Spatial frequency spectroscopy analysis(SFSA) visible resonance Raman(VRR) human brain metastatic lung cancer photomicrograph image support vector machine(SVM)
下载PDF
Designing shielded radio-frequency phased-array coils for magnetic resonance imaging 被引量:2
18
作者 徐文龙 张鞠成 +2 位作者 李霞 徐冰俏 陶贵生 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期46-53,共8页
In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed ... In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coll's winding pattern, the selection of a penalty factor is discussed in detail. 展开更多
关键词 active shield phased-array coil radio-frequency coil magnetic resonance imaging
下载PDF
Tunable characteristics of bending resonance frequency in magnetoelectric laminated composites
19
作者 陈蕾 李平 +1 位作者 文玉梅 朱永 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期511-515,共5页
As the magnetoelectric (ME) effect in piezoelectric/magnetostrictive laminated composites is mediated by mechanical deformation, the ME effect is significantly enhanced in the vicinity of resonance frequency. The be... As the magnetoelectric (ME) effect in piezoelectric/magnetostrictive laminated composites is mediated by mechanical deformation, the ME effect is significantly enhanced in the vicinity of resonance frequency. The bending resonance frequency (fr) of bilayered Terfenol-D/PZT (MP) laminated composites is studied, and our analysis predicts that (i) the bending resonance frequency of an MP laminated composite can be tuned by an applied dc magnetic bias (Hdc) due to the E effect; (ii) the bending resonance frequency of the MP laminated composite can be controlled by incorporating FeCuNbSiB layers with different thicknesses. The experimental results show that with H dc increasing from 0 Oe (1 Oe=79.5775 A/m) to 700 Oe, the bending resonance frequency can be shifted in a range of 32.68 kHz≤fr≤33.96 kHz. In addition, with the thickness of the FeCuNbSiB layer increasing from 0 μm to 90 μm, the bending resonance frequency of the MP laminated composite gradually increases from 33.66 kHz to 39.18 kHz. This study offers a method of adjusting the strength of dc magnetic bias or the thicknesses of the FeCuNbSiB layer to tune the bending resonance frequency for ME composite, which plays a guiding role in the ME composite design for real applications. 展开更多
关键词 magnetoelectric effect bending resonance frequency composite materials
下载PDF
Determination of Matrine and Oxymatrine in Radix Sophorae Flavescentis by Resonance Rayleigh Scattering, Second-order Scattering and Frequency Doubling Scattering Technique
20
作者 SONG Yan-qi LIU Shao-pu +1 位作者 LIU Zhong-fang HU Xiao-li 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第5期746-749,共4页
In 0.1 mol/L HCl medium, 12-tungstophosphoric(TP) acid reacted with matrine(Mat) and oxymatrine(Oxy) to form an ion-association complex. As a result, the new spectra of resonance Rayleigh scattering(RRS), seco... In 0.1 mol/L HCl medium, 12-tungstophosphoric(TP) acid reacted with matrine(Mat) and oxymatrine(Oxy) to form an ion-association complex. As a result, the new spectra of resonance Rayleigh scattering(RRS), second-order scattering(SOS) and frequency doubling scattering(FDS) appeared and their intensities were enhanced greatly. The maximum scattering wavelengths of RRS, SOS and FDS were located at 370, 670 and 390 nm, respectively. The in-crements of scattering intensity were directly proportional to the concentration of Mat and Oxy in a certain range. Based on this, the method for the determination of matrine and oxymatrine has been established. It has been applied to the determination of matrine and oxymatrine in samples of Radix sophorae flavescentis with satisfactory result. The reaction mechanism and reasons of RRS enhancement were discussed. 展开更多
关键词 MATRINE OXYMATRINE 12-Tungstophosphoric acid resonance Rayleigh scattering Second-order scattering frequency doubling scattering
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部