期刊文献+
共找到3,523篇文章
< 1 2 177 >
每页显示 20 50 100
Influence of sampling on three-dimensional surface shape measurement
1
作者 QIAO Nao-sheng Shang Xue 《中国光学(中英文)》 EI CAS CSCD 北大核心 2024年第6期1512-1520,共9页
In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation o... In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results. 展开更多
关键词 three-dimensional surface shape measurement sampling interval spectra overlapping measurement accuracy
下载PDF
Multi-objective strategy to optimize dithering technique for high-quality three-dimensional shape measurement 被引量:2
2
作者 Ning Cai Zhe-Bo Chen +1 位作者 Xiang-Qun Cao Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期381-386,共6页
Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the pro... Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts. 展开更多
关键词 three-dimensional(3D) SHAPE measurement MULTI-OBJECTIVE dithering GENETIC algorithm
下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
3
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
下载PDF
A fast and precise three-dimensional measurement system based on multiple parallel line lasers 被引量:1
4
作者 Yao Wang Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期276-284,共9页
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on... This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm. 展开更多
关键词 three-dimensional shape measurement multiple parallel line lasers fast and precise measurement parameter calibration
下载PDF
Three-Dimensional Measurement and Reconstruction of Fabric Drape Shape 被引量:1
5
作者 沈毅 尹红媛 刘玄木 《Journal of Donghua University(English Edition)》 EI CAS 2007年第1期39-42,共4页
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes... This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics. 展开更多
关键词 fabric drape non-contact measurement structurelight image process three-dimension reconstruction.
下载PDF
A method for phase reconstruction in optical three-dimensional shape measurement
6
作者 乔闹生 贺志 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第9期267-270,共4页
In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that ... In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method. 展开更多
关键词 phase reconstruction optical three-dimensional shape measurement measurement pre-cision
下载PDF
Three-Dimensional Velocity Distribution Measurement Using Ultrasonic Velocity Profiler with Developed Transducer
7
作者 Naruki Shoji Hiroshige Kikura +1 位作者 Hideharu Takahashi Wongsakorn Wongsaroj 《Journal of Flow Control, Measurement & Visualization》 2022年第1期32-55,共24页
This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with u... This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span> 展开更多
关键词 Doppler Frequency Liquid Velocity three-dimensional measurement Transducer Design ULTRASONIC
下载PDF
Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology
8
作者 胡永成 《外科研究与新技术》 2011年第2期125-125,共1页
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer... Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the 展开更多
关键词 BONE Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology CT
下载PDF
Instantaneous rotation speed measurement and error analysis for variable speed hydraulic system 被引量:1
9
作者 杨彬 谷立臣 +1 位作者 刘永 王平 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第4期315-321,共7页
In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer a... In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer and data acquisition card are introduced, and the major error source, influence mechanism and processing method of data quantization error are dis- cussed. By means of hybrid programming approach of LabVIEW and MATLAB, the instantaneous rotation speed measurement system for the piston motor in variable speed hydraulic system is designed. The simulation and experimental results show that the designed instantaneous speed measurement system is feasible. Furthermore, the sampling frequency has an important influ- ence on the instantaneous rotation speed measurement of piston motor and higher sampling frequency can lower quantization er- ror and improve measurement accuracy. 展开更多
关键词 variable speed hydraulic system instantaneous rotation speed measurement error analysis hybrid programming
下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
10
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
APPROACH OF IMPROVING PRECISION IN ULTRASONIC DOPPLER BLOODSTREAM SPEED MEASUREMENT BY CHAOS-BASED FREQUENCY DETECTING 被引量:3
11
作者 Zhang Shuqing Jin Shijiu +2 位作者 Lv Jiangtao Zhang Liguo Li Jun 《Journal of Electronics(China)》 2006年第3期457-460,共4页
It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with d... It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%. 展开更多
关键词 CHAOS Frequency detecting Bloodstream speed measuring Ultrasonic Doppler Signal-to-Noise Ratio (SNR) measuring precision
下载PDF
Volumetric measurement techniques for assessment of cutaneous neurofibromas:A review
12
作者 Xinyu Wang Jiayi Xu +2 位作者 Yun Zhu Chengjiang Wei Zhichao Wang 《Chinese Journal of Plastic and Reconstructive Surgery》 2024年第2期83-86,共4页
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc... Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain. 展开更多
关键词 Cutaneous neurofibroma Tumor volume measurement Vernier caliper Ultrasound Computed tomography Magnetic resonance imaging three-dimensional scanning imaging
下载PDF
A new method for high precsion instantaneous speedmeasurement of hydraulic system 被引量:1
13
作者 LIU Jia-min GU Li-chen SUN Yu 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第4期307-314,共8页
The instantaneous speed of a hydraulic system contains a wealth of operational information,and its accurate extraction is the basis for condition monitoring and fault diagnosis.In order to solve the problem of high ha... The instantaneous speed of a hydraulic system contains a wealth of operational information,and its accurate extraction is the basis for condition monitoring and fault diagnosis.In order to solve the problem of high hardware requirement for instantaneous speed measurement based on data acquisition card,a new method of high precision measurement is proposed.In this method,the time-displacement information of each tooth is obtained from the pulsed square wave signal of the gear disk collected by magnetoelectric sensors.The time-displacement curve is interpolated by the cubic spline interpolation method,and then the instantaneous speed is calculated by the five-point digital differential formula.The experimental results show that the method improves the speed measurement resolution and reduces the quantization error.The high precision instantaneous speed signal can also be acquired by hardware devices with less teeth and low sampling frequency.The related research results provide a theoretical basis and a method for improving the accuracy of instantaneous speed measurement. 展开更多
关键词 instantaneous speed measurement variable speed hydraulic system cubic spline interpolation five-point digital differentiation
下载PDF
Development of a Three-Dimensional Measuring System for Neonates' Head and Facial Morphology 被引量:1
14
作者 邓咏梅 易洁伦 +2 位作者 郭绮莲 黄小珍 吴新培 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期309-312,共4页
A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch... A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units. 展开更多
关键词 close-range photogrammetry (CRP) three-dimensional measurement NEONATES head and facialmorphology
下载PDF
Information fusion of train speed and distance measurements based on fuzzy adaptive Kalman filter algorithm 被引量:1
15
作者 FAN Ze yuan DONG Yu 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第3期286-292,共7页
The measurement accuracy of speed and distance in high speed train directly affects the control precision and driving efficiency of train control system. To improve the capability of train self control, a combined spe... The measurement accuracy of speed and distance in high speed train directly affects the control precision and driving efficiency of train control system. To improve the capability of train self control, a combined speed measurement and positioning method based on speed sensor and radar which is assisted by global positioning system(GPS) is proposed to improve the accuracy of measurement and reduce the dependence on the ground equipment. In consideration of the fact that the filtering precision of Kalman filter will decrease when the statistical characteristics are changing, this paper uses fuzzy comprehensive evaluation method to evaluate the sub filter, and information distribution coefficients are dynamically adjusted according to filtering reliability, which can improve the fusion accuracy and fault tolerance of the system. The sub filter is required to carry on the covariance shaping adaptive filtering when it is in the suboptimal state. The adjustment factor of error covariance is obtained according to the minimized cost function, which can improve the matching degree between the measured residual variance and the system recursive residual. The simulation results show that the improved filter algorithm can track the changes of the system effectively, enhance the filtering accuracy significantly, and improve the measurement accuracies of train speed and distance. 展开更多
关键词 information fusion federated Kalman filter fuzzy comprehensive evaluation train speed and distance measurements
下载PDF
Research on the measurement of belt speed by video in coal mine based on improved template matching algorithm 被引量:1
16
作者 ZHU Ai-chun HUA Wei +1 位作者 WANG Chun WANG Yong-xing 《Journal of Coal Science & Engineering(China)》 2011年第4期469-474,共6页
In order to improve the intelligence of video monitoring system of belt and make up the deficiency of higher failure rate and bad real-time performance in the traditional systems of measurement of belt speed, accordin... In order to improve the intelligence of video monitoring system of belt and make up the deficiency of higher failure rate and bad real-time performance in the traditional systems of measurement of belt speed, according to the fact that the light of coal mine is uneven, the strength of light changes greatly, the direction of belt movement is constant, and the position of camera was fixed, various algorithms of speed measurement by video were studied, and algorithm for template matching based on sum of absolute differences (SAD) and correlation coefficient was proposed and improved, besides, the tracking of feature regions was realized. Then, a camera calibration method using the invariance of the cross-ratio was adopted and the real-time measurement of belt speed by the hardware platform based on DM642 was realized. Finally, experiment results show that this method not only has advantages of high precision and strong anti-jamming capability but also can real-time reflect the changes of belt speed, so it has a comprehensive applicability. 展开更多
关键词 speed measurement by video template matching algorithm DM642 invariance of cross-ratio
下载PDF
A New Approach to Speed Measurement of Rotating Objects by Laser Interference Method
17
作者 李鹏生 张琢 +1 位作者 赵慧洁 陈军 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1994年第1期23-25,共3页
ANewApproachtoSpeedMeasurementofRotatingObjectsbyLaserInterferenceMethodLIPengshengZHANGZhuoZHAOHuijieCHENJu... ANewApproachtoSpeedMeasurementofRotatingObjectsbyLaserInterferenceMethodLIPengshengZHANGZhuoZHAOHuijieCHENJun(李鹏生)(张琢)(赵慧洁)(陈... 展开更多
关键词 ss: LASER INTERFERENCE ROTATING speed ROTATING angle measurement
下载PDF
High-speed railway channel measurements and characterizations: a review 被引量:3
18
作者 Tao ZHOU Cheng TAO +2 位作者 Liu LIU Jiahui QIU Rongchen SUN 《Journal of Modern Transportation》 2012年第4期199-205,共7页
Wireless communication for high-speed railways (HSRs) that provides reliable and high data rate communi- cation between the train and trackside networks is a challenging task. It is estimated that the wireless commu... Wireless communication for high-speed railways (HSRs) that provides reliable and high data rate communi- cation between the train and trackside networks is a challenging task. It is estimated that the wireless communication traffic could be as high as 65 Mbps per high-speed train. The development of such HSR communications systems and standards requires, in turn, accurate models for the HSR propagation channel. This article provides an overview of ex- isting HSR channel measurement campaigns in recent years. Particularly, some important measurement and modeling results in various HSR scenarios, such as viaduct and U-shaped groove (USG), are briefly described and analyzed. In addition, we review a novel channel sounding method, which can highly improve the measurement efficiency in HSR environment. 展开更多
关键词 high-speed railways wireless communication channel measurement VIADUCT U-shaped groove
下载PDF
Quantum speed limit of the double quantum dot in pure dephasing environment under measurement
19
作者 Zhenyu Lin Tian Liu +2 位作者 Zongliang Li Yanhui Zhang Kang Lan 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期146-151,共6页
The quantum speed limit(QSL)of the double quantum dot(DQD)system has been theoretically investigated by adopting the detection of the quantum point contact(QPC)in the pure dephasing environment.The Mandelstam–Tamm(MT... The quantum speed limit(QSL)of the double quantum dot(DQD)system has been theoretically investigated by adopting the detection of the quantum point contact(QPC)in the pure dephasing environment.The Mandelstam–Tamm(MT)type of the QSL bound which is based on the trace distance has been extended to the DQD system for calculating the shortest evolving time.The increase of decoherence rate can weaken the capacity for potential speedup(CPS)and delay the evolving process due to the frequently measurement localizing the electron in the DQD system.The system needs longer time to evolve to the target state as the enhancement of dephasing rate,because the strong interaction between pure dephasing environment and the DQD system could vary the oscillation of the electron.Increasing the dephasing rate can sharp the QSL bound,but the decoherence rate would weaken the former effect and vice versa.Moreover,the CPS would be raised by increasing the energy displacement,while the enhancement of the coupling strength between two quantum dots can diminish it.It is interesting that there has an inflection point,when the coupling strength is less than the value of the point,the increasing effect of the CPS from the energy displacement is dominant,otherwise the decreasing tendency of the CPS is determined by the coupling strength and suppress the action of the energy displacement if the coupling strength is greater than the point.Our results provide theoretical reference for studying the QSL time in a semiconductor device affected by numerous factors. 展开更多
关键词 quantum speed limits the DQD system the pure dephasing environment quantum measurement
下载PDF
Application of Fiber in Blood Speed Measurement
20
作者 SHANG Li-ping, ZHENG De-zhong, XIE Hua-bing, SHI Jin-shan (Yanshan University, Qinhuangdao 066004, CHN) 《Semiconductor Photonics and Technology》 CAS 2000年第2期126-128,共3页
There exist many methods to measure blood speed, all of which have some serious shortcomings. As fiber is characterized by tiny diameter, and low lost ratio of power and flexibility, it is suitable for measuring blood... There exist many methods to measure blood speed, all of which have some serious shortcomings. As fiber is characterized by tiny diameter, and low lost ratio of power and flexibility, it is suitable for measuring blood speed. It is proved that the speedometer has high space resolving power,high time resolving power, and outstanding capability of approaching target, etc. 展开更多
关键词 FIBER speed measurement Doppler frequency shifting
下载PDF
上一页 1 2 177 下一页 到第
使用帮助 返回顶部