Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a ...Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.展开更多
The direct current-direct current (DC-DC) converter is designed for 1 T static random access memory (SRAM) used in display driver integrated circuits (ICs), which consists of positive word-line voltage (VpwL),...The direct current-direct current (DC-DC) converter is designed for 1 T static random access memory (SRAM) used in display driver integrated circuits (ICs), which consists of positive word-line voltage (VpwL), negative word-line voltage (VinyL) and half-VDD voltage (VHDo) generator. To generate a process voltage temperature (PVT)-insensitive VpWL and VNWL, a set of circuits were proposed to generate reference voltages using bandgap reference current generators for respective voltage level detectors. Also, a VOWL regulator and a VNWL charge pump were proposed for a small-area and low-power design. The proposed VpwL regulator can provide a large driving current with a small area since it regulates an input voltage (VCI) from 2.5 to 3.3 V. The VmvL charge pump can be implemented as a high-efficiency circuit with a small area and low power since it can transfer pumped charges to VNWL node entirely. The DC-DC converter for 1 T SRAM were designed with 0.11 μm mixed signal process and operated well with satisfactory measurement results.展开更多
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche...This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.展开更多
基金supported by the State Key Laboratory of Advanced Power Transmission Technology(GEIRI-SKL-2020-011)。
文摘Due to the large number of submodules(SMs),and modular multilevel converters(MMCs)in high-voltage applications,they are usually regulated by the nearest level modulation(NLM).Moreover,the large number of SMs causes a challenge for the fault diagnosis strategy(FDS).This paper proposes a currentless FDS for MMC with NLM.In FDS,the voltage sensor is relocated to measure the output voltage of the SM.To acquire the capacitor voltage and avoid increasing extra sensors,a capacitor voltage calculation method is proposed.Based on the measurement of output voltages,the faults can be detected and the number of different-type switch open-circuit faults can be confirmed from the numerous SMs in an arm,which narrows the scope of fault localization.Then,the faulty SMs and faulty switches in these SMs are further located without arm current according to the sorting of capacitor voltages in the voltage balancing algorithm.The FDS is independent of the arm current,which can reduce the communication cost in the hierarchical control system of MMC.Furthermore,the proposed FDS not only simplifies the identification of switch open-circuit faults by confirming the scope of faults,but also detects and locates multiple different-type faults in an arm.The effectiveness of the proposed strategy is verified by the simulation results.
基金supported by the Second Stage of Brain Korea 21 Projectsfinancially supported by Changwon National University in 2011-2013
文摘The direct current-direct current (DC-DC) converter is designed for 1 T static random access memory (SRAM) used in display driver integrated circuits (ICs), which consists of positive word-line voltage (VpwL), negative word-line voltage (VinyL) and half-VDD voltage (VHDo) generator. To generate a process voltage temperature (PVT)-insensitive VpWL and VNWL, a set of circuits were proposed to generate reference voltages using bandgap reference current generators for respective voltage level detectors. Also, a VOWL regulator and a VNWL charge pump were proposed for a small-area and low-power design. The proposed VpwL regulator can provide a large driving current with a small area since it regulates an input voltage (VCI) from 2.5 to 3.3 V. The VmvL charge pump can be implemented as a high-efficiency circuit with a small area and low power since it can transfer pumped charges to VNWL node entirely. The DC-DC converter for 1 T SRAM were designed with 0.11 μm mixed signal process and operated well with satisfactory measurement results.
文摘This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.