The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve...The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct.展开更多
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw...The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.展开更多
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str...The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.展开更多
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ...This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application.展开更多
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le...Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.展开更多
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w...In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.展开更多
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f...This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.展开更多
Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-pow...Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-power systems,large-scale PV systems are more commercially attractive,because they can reduce the cost of the system per watt.The PV inverters with centralized and string structure have been applied in large-scale PV plant,but it is difficult to further increase the voltage and power levels for a single converter.In addition,the line-frequency isolation transformer requires a large amount of materials and has a large volume and weight.Therefore,it is a current trend for large-scale PV system to increase the voltage and power levels to directly connect to the medium-voltage power grid.Based on this,this paper investigates and compares several topologies of PV inverters without line-frequency transformer,including the MMC structure and the three-phase cascaded H-bridge(CHB)structure,which are able to directly connect to the 35kV medium-voltage power grid,and can not only make the voltage and power levels higher,but also further reduce the cost and volume of the whole system.展开更多
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima...This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.展开更多
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin...As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.展开更多
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing...One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms.展开更多
Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inver...Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inverter.The proposed circuit topology,control strategy,and related analysis are presented.The circuit topology of the inverter comprises a quasi-Z-source network with an integrated magnetic inductor,an active clamp circuit,a three-phase inverter bridge,and an output LC filter,all of which are connected in series.An improved 12-sector space vector modulation scheme is proposed based on the root-mean-square value of the voltage and the instantaneous value of the current.Furthermore,analyses of the inverter voltage transmission ratio,resonant process,and parametric design guidelines for integrated magnetic inductor and zero-voltage switching conditions are presented.Experimental results on a 1-kVA prototype inverter demonstrate that the proposed inverter exhibits a higher transmission ratio and efficiency than existing inverters;thus,the proposed inverter would have broad prospects in low-voltage DC-AC applications.展开更多
A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with t...A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (two inductors in series and two X connected capacitors). This new topology, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. As a result, the new embedded controlled reduced switch Z-source inverter system provides ride through capability during voltage sags, reduces line harmonics, improves power factor, reliability and extends output voltage range. Analysis, simulation and experiment result will be presented to demonstrate these new features.展开更多
This paper presents an electronic VSD (variable speed drive) for three-phase IM (induction motor) using a microcontroller. The VSD is designed for cooling applications where the 1M is coupled to a cooling fan. The...This paper presents an electronic VSD (variable speed drive) for three-phase IM (induction motor) using a microcontroller. The VSD is designed for cooling applications where the 1M is coupled to a cooling fan. The drive receives temperature feedback from objects to be cooled and output a corresponding frequency to the IM. A prototype of the VSD is constructed to control a 175 W, four pole, squirrel cage three-phase IM. The heart of the control circuit is a low-cost microchip's PICI6F777 microcontroller which is programmed using C language to generate variable frequency SPWM (sinusoidal pulse width modulation) switching signals. These switching signals are fed to an 1GBT inverter. The VSD constructed can be switched between two modes of speed control" automatic temperature-controlled mode and manual user-controlled mode. Cost savings using the prototype are demonstrated.展开更多
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr...In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype.展开更多
When multiple distributed converters are integrated, the high frequency harmonics will randomly accumulate at the point of common coupling(PCC). This paper proposes a new fast global synchronous discontinuous pulse wi...When multiple distributed converters are integrated, the high frequency harmonics will randomly accumulate at the point of common coupling(PCC). This paper proposes a new fast global synchronous discontinuous pulse width modulation(GSDPWM) method of threephase inverters to effectively attenuate the high frequency current harmonics at PCC. Firstly, the basic principle and the realization method of GSDPWM for three-phase inverters are explained, which can be employed for different modulation types. Then a fast calculation method,which can equally derive the minimized total harmonic distortion(THD) of total current, is proposed to release the calculation burden. Finally, MATLAB simulations and experimental results are presented to verify the performance of GSDPWM.展开更多
The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, present...The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, presenting itself as a voltage source with significant impedance. This means that an inverter using an LCL filter may interact with other grid-connected inverters via the nonideal grid. In this paper, damping optimization of LCLfilters to reduce this interaction is studied for a three-phase voltage source inverter(VSI). Simulation results show that resonant oscillation occurs in a distributed power grid, even if the VSI with an LCL filter is well designed for standalone applications. A small-signal analysis is performed to predict this stability problem and to locate the boundary of the instability using an impedance approach. Based on these analytical results, optimized damping of the LCLfilter can be designed. The oscillation phenomena and optimized damping design are verified by simulations and experimental measurements.展开更多
This paper proposes a sliding mode controller based on robust model reference adaptive proportional-integral(RMRA-PI)control for a stand-alone voltage source inverter(SA-VSI).The proposed controller has two control lo...This paper proposes a sliding mode controller based on robust model reference adaptive proportional-integral(RMRA-PI)control for a stand-alone voltage source inverter(SA-VSI).The proposed controller has two control loops where the coefficients of PI controller are regulated by the adaptive sliding law.This method is used to regulate the output voltage of the inverter under different load conditions and uncertainty,and adapts the output to the reference model to reduce the total harmonic distortion(THD).In this paper,the stability of the proposed controller is proven by using Lyapunov's theory and Barbalet’s lemma.The proposed controller performs well in voltage regulation such as low THD under sudden load change and uncertainty.Also,the results of the proposed controller are compared with PI controller to show the effectiveness of the presented control system.展开更多
Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase ...Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase line losses but also result in neutral potential variations.For the LV AC distribution grid established by a grid-forming inverter(e.g.,uninterruptible power supply and solid-state-transformer),it also suffers from the same neutral current issues.Therefore,this paper comparatively studies several neutral current control approaches and their impacts on grid voltage balance,which is required by grid code.Then,this paper proposes an optimal neutral current control approach,which can obtain maximum neutral current suppression with less impact on grid voltage balance.The correctness of the theoretical analysis is validated through both simulation and experimental results.展开更多
Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control pe...Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control performance of interfaced inverter in MG and dramatically leads to MG voltage unbalance. In this paper, a negative-sequence compensation based three-phase voltage unified correction strategy is proposed. While MG operates in islanded mode, a positive virtual impedance control is used to eliminate the negative voltage resulted from the negative-sequence current,and then a positive-sequence voltage control loop and negative-sequence control loop are used to improve the inverter control performance. While MG operates in grid-tied mode,the inverter operates as a negative-sequence current source to compensate the negative-sequence currents of loads to guarantee the point of common coupling(PCC) voltage balance.By using the proposed strategy, the voltage control performance of inverter can be improved;the MG power quality can be enhanced significantly. Simulation and experimental results verify the effectiveness of the proposed method.展开更多
文摘The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct.
基金Project (No. 50477033) supported by the National Natural Science Foundation of China
文摘The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly.
基金National Natural Science Foundation of China(No.51767014)China Railway Corporation of Science and Technology Research and Development Projects(No.2016J010-C)
文摘The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness.
文摘This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application.
文摘Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.
基金supported by the Shanghai Education Committee Scientific Research Subsidization (Grant No.05AZ30)the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20060280018)
文摘In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
文摘This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.
基金This work was supported by National Natural Science Foundation of China(51937003).
文摘Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-power systems,large-scale PV systems are more commercially attractive,because they can reduce the cost of the system per watt.The PV inverters with centralized and string structure have been applied in large-scale PV plant,but it is difficult to further increase the voltage and power levels for a single converter.In addition,the line-frequency isolation transformer requires a large amount of materials and has a large volume and weight.Therefore,it is a current trend for large-scale PV system to increase the voltage and power levels to directly connect to the medium-voltage power grid.Based on this,this paper investigates and compares several topologies of PV inverters without line-frequency transformer,including the MMC structure and the three-phase cascaded H-bridge(CHB)structure,which are able to directly connect to the 35kV medium-voltage power grid,and can not only make the voltage and power levels higher,but also further reduce the cost and volume of the whole system.
文摘This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.
文摘As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.
文摘One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms.
基金the National Natural Science Foundation of China(Grant No.51537001)Fund of“Taishan Scholar”Climbing Plan of Shandong Province,China。
文摘Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inverter.The proposed circuit topology,control strategy,and related analysis are presented.The circuit topology of the inverter comprises a quasi-Z-source network with an integrated magnetic inductor,an active clamp circuit,a three-phase inverter bridge,and an output LC filter,all of which are connected in series.An improved 12-sector space vector modulation scheme is proposed based on the root-mean-square value of the voltage and the instantaneous value of the current.Furthermore,analyses of the inverter voltage transmission ratio,resonant process,and parametric design guidelines for integrated magnetic inductor and zero-voltage switching conditions are presented.Experimental results on a 1-kVA prototype inverter demonstrate that the proposed inverter exhibits a higher transmission ratio and efficiency than existing inverters;thus,the proposed inverter would have broad prospects in low-voltage DC-AC applications.
文摘A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (two inductors in series and two X connected capacitors). This new topology, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. As a result, the new embedded controlled reduced switch Z-source inverter system provides ride through capability during voltage sags, reduces line harmonics, improves power factor, reliability and extends output voltage range. Analysis, simulation and experiment result will be presented to demonstrate these new features.
文摘This paper presents an electronic VSD (variable speed drive) for three-phase IM (induction motor) using a microcontroller. The VSD is designed for cooling applications where the 1M is coupled to a cooling fan. The drive receives temperature feedback from objects to be cooled and output a corresponding frequency to the IM. A prototype of the VSD is constructed to control a 175 W, four pole, squirrel cage three-phase IM. The heart of the control circuit is a low-cost microchip's PICI6F777 microcontroller which is programmed using C language to generate variable frequency SPWM (sinusoidal pulse width modulation) switching signals. These switching signals are fed to an 1GBT inverter. The VSD constructed can be switched between two modes of speed control" automatic temperature-controlled mode and manual user-controlled mode. Cost savings using the prototype are demonstrated.
基金supported by The Scientific and Technological Research Council of Turkey(TUBITAK)(No.110E212)
文摘In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype.
文摘When multiple distributed converters are integrated, the high frequency harmonics will randomly accumulate at the point of common coupling(PCC). This paper proposes a new fast global synchronous discontinuous pulse width modulation(GSDPWM) method of threephase inverters to effectively attenuate the high frequency current harmonics at PCC. Firstly, the basic principle and the realization method of GSDPWM for three-phase inverters are explained, which can be employed for different modulation types. Then a fast calculation method,which can equally derive the minimized total harmonic distortion(THD) of total current, is proposed to release the calculation burden. Finally, MATLAB simulations and experimental results are presented to verify the performance of GSDPWM.
基金supported by National Natural Science Foundation of China(No.51507118)by Open Fund of State Key Laboratory of Operation and Control of Renewable Energy and Storage Systems,China Electric Power Research Institute(Research on renewable energy power generation grid-connected converter fault tolerance evaluation method
文摘The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, presenting itself as a voltage source with significant impedance. This means that an inverter using an LCL filter may interact with other grid-connected inverters via the nonideal grid. In this paper, damping optimization of LCLfilters to reduce this interaction is studied for a three-phase voltage source inverter(VSI). Simulation results show that resonant oscillation occurs in a distributed power grid, even if the VSI with an LCL filter is well designed for standalone applications. A small-signal analysis is performed to predict this stability problem and to locate the boundary of the instability using an impedance approach. Based on these analytical results, optimized damping of the LCLfilter can be designed. The oscillation phenomena and optimized damping design are verified by simulations and experimental measurements.
文摘This paper proposes a sliding mode controller based on robust model reference adaptive proportional-integral(RMRA-PI)control for a stand-alone voltage source inverter(SA-VSI).The proposed controller has two control loops where the coefficients of PI controller are regulated by the adaptive sliding law.This method is used to regulate the output voltage of the inverter under different load conditions and uncertainty,and adapts the output to the reference model to reduce the total harmonic distortion(THD).In this paper,the stability of the proposed controller is proven by using Lyapunov's theory and Barbalet’s lemma.The proposed controller performs well in voltage regulation such as low THD under sudden load change and uncertainty.Also,the results of the proposed controller are compared with PI controller to show the effectiveness of the presented control system.
基金the National Natural Science Foundation of China(NSFC)under Grant 51767017National Science and Technology Major Project of Gansu Province under Grant 19ZD2GA003.
文摘Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase line losses but also result in neutral potential variations.For the LV AC distribution grid established by a grid-forming inverter(e.g.,uninterruptible power supply and solid-state-transformer),it also suffers from the same neutral current issues.Therefore,this paper comparatively studies several neutral current control approaches and their impacts on grid voltage balance,which is required by grid code.Then,this paper proposes an optimal neutral current control approach,which can obtain maximum neutral current suppression with less impact on grid voltage balance.The correctness of the theoretical analysis is validated through both simulation and experimental results.
基金supported by the project of China Electric Power Research Institute(No.GYB51201404488)National High Technology Research and Development Program of China(863 Program)(No.2015AA050606)
文摘Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control performance of interfaced inverter in MG and dramatically leads to MG voltage unbalance. In this paper, a negative-sequence compensation based three-phase voltage unified correction strategy is proposed. While MG operates in islanded mode, a positive virtual impedance control is used to eliminate the negative voltage resulted from the negative-sequence current,and then a positive-sequence voltage control loop and negative-sequence control loop are used to improve the inverter control performance. While MG operates in grid-tied mode,the inverter operates as a negative-sequence current source to compensate the negative-sequence currents of loads to guarantee the point of common coupling(PCC) voltage balance.By using the proposed strategy, the voltage control performance of inverter can be improved;the MG power quality can be enhanced significantly. Simulation and experimental results verify the effectiveness of the proposed method.