期刊文献+
共找到18篇文章
< 1 >
每页显示 20 50 100
The Research of Three-phase Boost/Buck-boost DC-AC Inverter
1
作者 Xiangli Li Zhaoyang Yan +1 位作者 Yanni Gao Hanhong Qi 《Energy and Power Engineering》 2013年第4期906-913,共8页
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ... This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application. 展开更多
关键词 three-phase BOOST SINGLE-STAGE inverter three-phase BUCK-BOOST SINGLE-STAGE inverter Double-loop CONTROLLER Sliding Mode CONTROLLER
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
2
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE inverter three-phase FOUR-LEG inverter Unbalanced LOAD Imbalanced VOLTAGE
下载PDF
Sensorless Control of Four-Switch Inverter for Brushless DC Motor Drive and Its Simulation
3
作者 Sathish Kumar Shanmugam Meenakumari Ramachandran +1 位作者 Krishna Kumar Kanagaraj Anbarasu Loganathan 《Circuits and Systems》 2016年第6期726-734,共9页
The major function of this proposed research is to control the speed of the brushless DC motor with sensor less control for four-switch three phase inverter. This proposed system is simplified the topological structur... The major function of this proposed research is to control the speed of the brushless DC motor with sensor less control for four-switch three phase inverter. This proposed system is simplified the topological structure of the conventional six-switch three phase inverter. In this proposed method, a new structure of four-switch three phase inverter [1] with reduced number of switches for system is introduced to reduce the mechanical commutation, switching losses that occur in the six-switch method. The proposed inverter fed brushless DC motor used in sensorless control schemes which is used for sensing positioning signals. To improve sensor less control performance, four-switch electronic commutation modes based proportional intergral controller scheme is implemented. In this four-switch three phase inverter reduction of switches, low cost control and saving of hall sensor were incorporated. The feasibility of the proposed sensor less control four-switch three phase inverter fed brushless DC motor drive is implemented, analysed using MATLAB/SIMULINK, effective simulation results have been validated out successfully. 展开更多
关键词 Brushless DC Motor four-switch Three Phase inverter Proportional Integral Controller Sensorless Control
下载PDF
Topological Comparison and Analysis of Medium-voltage and High-power Direct-linked PV Inverter 被引量:2
4
作者 Xing Zhang Mingda Wang +3 位作者 Tao Zhao Wang Mao Yuhua Hu Renxian Cao 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期327-334,共8页
Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-pow... Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-power systems,large-scale PV systems are more commercially attractive,because they can reduce the cost of the system per watt.The PV inverters with centralized and string structure have been applied in large-scale PV plant,but it is difficult to further increase the voltage and power levels for a single converter.In addition,the line-frequency isolation transformer requires a large amount of materials and has a large volume and weight.Therefore,it is a current trend for large-scale PV system to increase the voltage and power levels to directly connect to the medium-voltage power grid.Based on this,this paper investigates and compares several topologies of PV inverters without line-frequency transformer,including the MMC structure and the three-phase cascaded H-bridge(CHB)structure,which are able to directly connect to the 35kV medium-voltage power grid,and can not only make the voltage and power levels higher,but also further reduce the cost and volume of the whole system. 展开更多
关键词 Direct-linked PV inverter large-scale PV system MMC structure three-phase CHB structure.
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:3
5
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
6
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter three-phase GRID-CONNECTED inverter DECOUPLING Control
下载PDF
Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads
7
作者 Wenhua HU Weiming Ma Chunxi LIU 《Journal of Electromagnetic Analysis and Applications》 2010年第1期39-44,共6页
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing... One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms. 展开更多
关键词 three-phase inverter Unbalanced Load the three-phase OUTPUT Voltage SYMMETRIC Medium Frequency P+Resonant CONTROLLER
下载PDF
Practical Implementation of Embedded Controlled Reduced Switch Z-Source Inverter-Fed Induction Motor Drive
8
作者 K. Srinivasan T. Vijayakumar 《Circuits and Systems》 2016年第9期2189-2195,共8页
A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with t... A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (two inductors in series and two X connected capacitors). This new topology, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. As a result, the new embedded controlled reduced switch Z-source inverter system provides ride through capability during voltage sags, reduces line harmonics, improves power factor, reliability and extends output voltage range. Analysis, simulation and experiment result will be presented to demonstrate these new features. 展开更多
关键词 Embedded Controller Harmonic Distortion four-switch three-phase inverter Z-Source inverter
下载PDF
SVM strategy and analysis of a three-phase quasi-Z-source inverter with high voltage transmission ratio
9
作者 CHEN DaoLian ZHAO JiaWei QIN ShuRan 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第10期2996-3010,共15页
Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inver... Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inverter.The proposed circuit topology,control strategy,and related analysis are presented.The circuit topology of the inverter comprises a quasi-Z-source network with an integrated magnetic inductor,an active clamp circuit,a three-phase inverter bridge,and an output LC filter,all of which are connected in series.An improved 12-sector space vector modulation scheme is proposed based on the root-mean-square value of the voltage and the instantaneous value of the current.Furthermore,analyses of the inverter voltage transmission ratio,resonant process,and parametric design guidelines for integrated magnetic inductor and zero-voltage switching conditions are presented.Experimental results on a 1-kVA prototype inverter demonstrate that the proposed inverter exhibits a higher transmission ratio and efficiency than existing inverters;thus,the proposed inverter would have broad prospects in low-voltage DC-AC applications. 展开更多
关键词 quasi-Z-source inverter three-phase inverter ZERO-VOLTAGE-SWITCHING magnetically integrated inductor space vector modulation
原文传递
Highly efficient three-phase grid-connected parallel inverter system 被引量:3
10
作者 Evren ISEN Ahmet Faruk BAKAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1079-1089,共11页
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr... In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype. 展开更多
关键词 Active filter inverter efficiency RIPPLE CANCELLATION three-phase GRID-CONNECTED inverter
原文传递
Global synchronous discontinuous pulse width modulation method with fast calculation capability for distributed three-phase inverters 被引量:3
11
作者 Tao XU Ran WEI +1 位作者 Ke ZHOU Feng GAO 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期103-112,共10页
When multiple distributed converters are integrated, the high frequency harmonics will randomly accumulate at the point of common coupling(PCC). This paper proposes a new fast global synchronous discontinuous pulse wi... When multiple distributed converters are integrated, the high frequency harmonics will randomly accumulate at the point of common coupling(PCC). This paper proposes a new fast global synchronous discontinuous pulse width modulation(GSDPWM) method of threephase inverters to effectively attenuate the high frequency current harmonics at PCC. Firstly, the basic principle and the realization method of GSDPWM for three-phase inverters are explained, which can be employed for different modulation types. Then a fast calculation method,which can equally derive the minimized total harmonic distortion(THD) of total current, is proposed to release the calculation burden. Finally, MATLAB simulations and experimental results are presented to verify the performance of GSDPWM. 展开更多
关键词 Global synchronous pulse width modulation three-phase inverters High frequency harmonics Discontinuous pulse width modulation
原文传递
A Sliding Mode Controller Based on Robust Model Reference Adaptive Proportional-integral Control for Stand-alone Three-phase Inverter 被引量:1
12
作者 Hadi Esmaeili Mehdi Asadi 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第3期668-678,共11页
This paper proposes a sliding mode controller based on robust model reference adaptive proportional-integral(RMRA-PI)control for a stand-alone voltage source inverter(SA-VSI).The proposed controller has two control lo... This paper proposes a sliding mode controller based on robust model reference adaptive proportional-integral(RMRA-PI)control for a stand-alone voltage source inverter(SA-VSI).The proposed controller has two control loops where the coefficients of PI controller are regulated by the adaptive sliding law.This method is used to regulate the output voltage of the inverter under different load conditions and uncertainty,and adapts the output to the reference model to reduce the total harmonic distortion(THD).In this paper,the stability of the proposed controller is proven by using Lyapunov's theory and Barbalet’s lemma.The proposed controller performs well in voltage regulation such as low THD under sudden load change and uncertainty.Also,the results of the proposed controller are compared with PI controller to show the effectiveness of the presented control system. 展开更多
关键词 Robust model reference adaptive proportional-integral(RMRA-PI)control stand-alone inverter three-phase inverter voltage control Lyapunov's theory
原文传递
Optimized damping for LCL filters in three-phase voltage source inverters coupled by power grid 被引量:1
13
作者 Meng HUANG Jianjun SUN +1 位作者 Yu PENG Xiaoming ZHA 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期642-651,共10页
The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, present... The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, presenting itself as a voltage source with significant impedance. This means that an inverter using an LCL filter may interact with other grid-connected inverters via the nonideal grid. In this paper, damping optimization of LCLfilters to reduce this interaction is studied for a three-phase voltage source inverter(VSI). Simulation results show that resonant oscillation occurs in a distributed power grid, even if the VSI with an LCL filter is well designed for standalone applications. A small-signal analysis is performed to predict this stability problem and to locate the boundary of the instability using an impedance approach. Based on these analytical results, optimized damping of the LCLfilter can be designed. The oscillation phenomena and optimized damping design are verified by simulations and experimental measurements. 展开更多
关键词 LCL filter three-phase voltage source inverter Non-ideal power grid Optimized design Interacting converters
原文传递
Zero Sequence Voltage and Current Control in Four-wire Grids-fed by Grid-forming Inverters
14
作者 Zixian Zhu Wei Chen Vito Giuseppe Monopoli 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第6期2272-2279,共8页
Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase ... Low voltage three-phase four-wire AC distribution grids may experience high neutral current,mainly caused by asymmetrical distribution of single-phase loads in three phases.High neutral current will not only increase line losses but also result in neutral potential variations.For the LV AC distribution grid established by a grid-forming inverter(e.g.,uninterruptible power supply and solid-state-transformer),it also suffers from the same neutral current issues.Therefore,this paper comparatively studies several neutral current control approaches and their impacts on grid voltage balance,which is required by grid code.Then,this paper proposes an optimal neutral current control approach,which can obtain maximum neutral current suppression with less impact on grid voltage balance.The correctness of the theoretical analysis is validated through both simulation and experimental results. 展开更多
关键词 LV AC grid neutral current reduction grid-forming inverter three-phase four-wire system
原文传递
Overview on Fault-Tolerant Four-Switch Three-Phase Voltage Source Converters
15
作者 Kai Ni Yihua Hu +1 位作者 Yang Liu Chun Gan 《Chinese Journal of Electrical Engineering》 CSCD 2017年第2期87-101,共15页
With the rapid development and widespread applications of power electronic converters,strong fault-tolerant capability of power electronic converters is required since they play important roles in power systems.In thi... With the rapid development and widespread applications of power electronic converters,strong fault-tolerant capability of power electronic converters is required since they play important roles in power systems.In this paper,a review of one of the most promising fault-tolerant topologies for semiconductor open-circuit fault,called four-switch three-phase(FSTP)topology,is presented in terms of modeling analysis,modulation techniques,and control strategies.The configuration of FSTP voltage source converter(VSC)is illustrated.To minimize the negative effects caused by the innate drawbacks of this fault-tolerant converter topology,considerable research has been carried out regarding modulation techniques and control strategies.The modulation principle for FSTP topology is explained in detail,since the performance of FSTP VSCs relies on it.This paper aims to illustrate current research progress on this fault-tolerant FSTP VSC topology. 展开更多
关键词 Fault-tolerant ability four-switch three-phase(FSTP)topology voltage source converter(VSC) modeling analysis modulation techniques control strategies
原文传递
Control strategy for microgrid under three-phase unbalance condition 被引量:10
16
作者 Hongtao SHI Fang ZHUO +1 位作者 Hao YI Zhiqing GENG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期94-102,共9页
Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control pe... Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control performance of interfaced inverter in MG and dramatically leads to MG voltage unbalance. In this paper, a negative-sequence compensation based three-phase voltage unified correction strategy is proposed. While MG operates in islanded mode, a positive virtual impedance control is used to eliminate the negative voltage resulted from the negative-sequence current,and then a positive-sequence voltage control loop and negative-sequence control loop are used to improve the inverter control performance. While MG operates in grid-tied mode,the inverter operates as a negative-sequence current source to compensate the negative-sequence currents of loads to guarantee the point of common coupling(PCC) voltage balance.By using the proposed strategy, the voltage control performance of inverter can be improved;the MG power quality can be enhanced significantly. Simulation and experimental results verify the effectiveness of the proposed method. 展开更多
关键词 MICROGRID inverter three-phase unbalance Negative compensation
原文传递
Adaptive perturb and observe maximum power point tracking with current predictive and decoupled power control for gridconnected photovoltaic inverters 被引量:9
17
作者 Yong YANG Huiqing WEN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第2期422-432,共11页
In order to improve maximum power point tracking(MPPT) performance, a variable and adaptive perturb and observe(P&O)method with current predictive control is proposed. This is applied in three-phase threelevel neu... In order to improve maximum power point tracking(MPPT) performance, a variable and adaptive perturb and observe(P&O)method with current predictive control is proposed. This is applied in three-phase threelevel neutral-point clamped(NPC) photovoltaic(PV)generation systems. To control the active power and the reactive power independently,the decoupled power control combined with a space vector modulation block is adopted for three-phase NPC inverters in PV generation systems.To balance the neutral-point voltage of the three-phase NPC grid-connected inverter, a proportional and integral control is used by adj usting the dwell time of small voltage vectors. A three-phase NPC inverter rated at 12 kVA was established. The performance of the proposed method was tested and compared with the fixed perturbation MPPT algorithm under different conditions. Experimental results confirm the feasibility and advantages of the proposed method. 展开更多
关键词 Maximum POWER POINT tracking(MPPT) Perturb and observe(P&O) CURRENT PREDICTIVE controlDecoupled POWER control three-phase neutral-point CLAMPED inverter
原文传递
Open-circuit fault diagnosis and fault tolerance for shunt active power filter 被引量:1
18
作者 彭涛 赵帅 +1 位作者 但汉兵 玉华雄 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第11期2582-2595,共14页
The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is... The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method. 展开更多
关键词 FAULT diagnosis FAULT TOLERANT reference model over-modulation three-phase four-switch TOPOLOGY SHUNT active power filter
下载PDF
上一页 1 下一页 到第