期刊文献+
共找到13篇文章
< 1 >
每页显示 20 50 100
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
1
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
2
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
3
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
4
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter three-phase grid-connected inverter DECOUPLING Control
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
5
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(LCL)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
6
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
7
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
The Resonance Suppression for Parallel Photovoltaic Grid-connected Inverters in Weak Grid 被引量:6
8
作者 Qiu-Xia Yang Kun Li +1 位作者 Cui-Mei Zhao Hu Wang 《International Journal of Automation and computing》 EI CSCD 2018年第6期716-727,共12页
Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o... Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method. 展开更多
关键词 Parallel photovoltaic grid-connected inverters weak grid grid impedance resonance peak branch voltage and current double feedback.
原文传递
Highly efficient three-phase grid-connected parallel inverter system 被引量:3
9
作者 Evren ISEN Ahmet Faruk BAKAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1079-1089,共11页
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr... In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype. 展开更多
关键词 Active filter inverter efficiency RIPPLE CANCELLATION three-phase grid-connected inverter
原文传递
Impedance Modeling and Stability Analysis of PV Grid-connected Inverter Systems Considering Frequency Coupling 被引量:12
10
作者 Shaojian Song Ze Wei +2 位作者 Yuzhang Lin Bin Liu Hui Liu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期279-290,共12页
Impedance analysis is an effective method to analyze the oscillation issue associated with grid-connected photovoltaic systems.However,the existing impedance modeling of a gridconnected photovoltaic inverter usually o... Impedance analysis is an effective method to analyze the oscillation issue associated with grid-connected photovoltaic systems.However,the existing impedance modeling of a gridconnected photovoltaic inverter usually only considers the effect of a single perturbation frequency,ignoring the coupling frequency response between the internal control loops of a grid-connected inverter,which severely affects the accuracy of the stability analysis.Hence,a method of impedance modeling and stability analysis for grid-connected photovoltaic inverters considering cross-coupling frequency is proposed in this paper.First,the generation mechanism of frequency coupling in gridconnected photovoltaic inverters,and the relationship between the coupling frequency and perturbation frequency are analyzed.Secondly,a sequence impedance model of grid-connected photovoltaic systems considering the coupling frequency is established by using the harmonic linearization method.The impact of DC bus voltage control strategy on frequency coupling characteristics of a grid-connected photovoltaic system is evaluated,and the impact of a coupling frequency term on system stability is quantitatively analyzed.Finally,the advantages of the proposed method are verified by several simulations.The results show that the proposed impedance model can accurately predict the potential resonance points of the system,and the coupling frequency characteristics will become much stronger with smaller DC bus capacitance or larger bandwidth of the DC bus controller. 展开更多
关键词 DC bus voltage control frequency coupling grid-connected photovoltaic inverter system(PVs) harmonic linearization sub-synchronous oscillation
原文传递
New inverter topology for ground current suppression in transformerless photovoltaic system application 被引量:9
11
作者 Xiaoqiang GUO Huaibao WANG +1 位作者 Zhigang LU Baocheng WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第2期191-194,共4页
An interesting inverter topology is proposed in this paper.It is similar to the typical three-phase full bridge inverter from the topology point of view,but smartly designed for the ground current reduction in single-... An interesting inverter topology is proposed in this paper.It is similar to the typical three-phase full bridge inverter from the topology point of view,but smartly designed for the ground current reduction in single-phase photovoltaic(PV)inverter applications.Theoretical analysis is conducted to clarify the operation mechanism of the proposed topology.Performance evaluation is carried out to verify the effectiveness of the proposed topology for the ground current suppression. 展开更多
关键词 Ground current grid-connected inverter photovoltaic(PV)system
原文传递
Techno-economic-environmental feasibility study of a photovoltaic system in northern part of Iran including a two-stage multi-string inverter with DC-DC ZETA converter and a modified P&O algorithm
12
作者 Sina Semeskandeh Mehrdad Hojjat Mohamad Hosseini Abardeh 《Clean Energy》 EI 2022年第1期127-140,共14页
Inverters play a significant role in the configuration of grid-connected photovoltaic(PV)systems.The perturb-and-observe(P&O)algorithm is a common method to derive the maximum power from grid-connected inverters;h... Inverters play a significant role in the configuration of grid-connected photovoltaic(PV)systems.The perturb-and-observe(P&O)algorithm is a common method to derive the maximum power from grid-connected inverters;however,the possibility of losing maximum power due to sudden changes in radiation is a significant drawback of this control strategy.To overcome this barrier,the two-stage multi-string inverter using the ZETA DC-DC converter and a novel P&O algorithm has been proposed to increase the efficiency of these systems.The proposed inverter has been simulated in MATLAB/SIMULINK software.To investigate the performance of the proposed inverter,technical,environmental and economic feasibility studies have been performed for the construction of a 5-kW PV power plant in a northern city of Iran(Sari)using the RETScreen software developed by Natural Resources Canada.On the other hand,most feasibility studies for power-plant construction are based on the concept of inverter peak efficiency,which leads to non-optimal system design due to the short operation duration of the inverter at this value.However,the weighted European efficiency has been used in the feasibility study for more accurate computations.Moreover,the performance of the proposed inverter is compared to that of a two-stage multi-string inverter using a conventional P&O algorithm and the single-stage(central)inverter.The simulation results indicated that the proposed inverter injects 7.6 MW of power into the grid per year.Moreover,it prevents the emission of 88 tons of CO_(2)(over 20 years),which is equivalent to saving 1883.5 litres of gasoline per year. 展开更多
关键词 photovoltaic ENVIRONMENTAL inverter grid-connected feasibility P&O algorithm
原文传递
Single-phase Grid-connected PV System with Golden Section Search-based MPPT Algorithm
13
作者 Shuang Xu Riming Shao +1 位作者 Bo Cao Liuchen Chang 《Chinese Journal of Electrical Engineering》 CSCD 2021年第4期25-36,共12页
Maximum power point tracking(MPPT)is a technique employed for with variable-power sources,such as solar,wind,and ocean,to maximize energy extraction under all conditions.The commonly used perturb and observe(P&O)a... Maximum power point tracking(MPPT)is a technique employed for with variable-power sources,such as solar,wind,and ocean,to maximize energy extraction under all conditions.The commonly used perturb and observe(P&O)and incremental conductance(INC)methods have advantages such as ease of implementation,but they also have the challenge of selecting the most optimized perturbation step or increment size while considering the trade-off between convergence time and oscillation.To address these issues,an MPPT solution for grid-connected photovoltaic(PV)systems is proposed that combines the golden section search(GSS),P&O,and INC methods to simultaneously achieve faster convergence and smaller oscillation,converging to the MPP by repeatedly narrowing the width of the interval at the rate of the golden ratio.The proposed MPPT technique was applied to a PV system consisting of a PV array,boost chopper,and inverter.Simulation and experimental results verify the feasibility and effectiveness of the proposed MPPT technique,by which the system is able to locate the MPP in 36 ms and regain a drifting MPP in approximately 30 ms under transient performance.The overall MPPT efficiency is 98.99%. 展开更多
关键词 grid-connected system maximum power point tracking(MPPT) photovoltaic(PV)system single-phase inverter
原文传递
上一页 1 下一页 到第