For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act...For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.展开更多
The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the...The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the unbalance occurs,the safe operation of the electrical equipment will be seriously jeopardized.This paper proposes a Hierarchical Temporal Memory(HTM)-based three-phase unbalance prediction model consisted by the encoder for binary coding,the spatial pooler for frequency pattern learning,the temporal pooler for pattern sequence learning,and the sparse distributed representations classifier for unbalance prediction.Following the feasibility of spatial-temporal streaming data analysis,we adopted this brain-liked neural network to a real-time prediction for power load.We applied the model in five cities(Tangshan,Langfang,Qinhuangdao,Chengde,Zhangjiakou)of north China.We experimented with the proposed model and Long Short-term Memory(LSTM)model and analyzed the predict results and real currents.The results show that the predictions conform to the reality;compared to LSTM,the HTM-based prediction model shows enhanced accuracy and stability.The prediction model could serve for the overload warning and the load planning to provide high-quality power grid operation.展开更多
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit....A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%.展开更多
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i...In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results.展开更多
This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or abs...This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation.展开更多
The ubiquitous power Internet of Things(UPIoT)is an intelligent service system with comprehensive state perception,efficient processing,and flexible application of information.It focuses on each link of the power syst...The ubiquitous power Internet of Things(UPIoT)is an intelligent service system with comprehensive state perception,efficient processing,and flexible application of information.It focuses on each link of the power system and makes full use of the mobile internet,artificial intelligence,and other advanced information and communication technologies in order to realize the inter-human interaction of all things in all links of the power system.This article systematically presents to the national and international organizations and agencies in charge of UPIoT layer standardization the status quo of the research on the Internet of Things(IoT)-related industry standards system.It briefly describes the generic standard classification methods,layered architecture,conceptual model,and system tables in the UPIoT application layer.Based on the principles of inheritance,innovation,and practicability,this study divides the application layer into customer service,power grid operation,integrated energy,and enterprise operation,emerging business and analyzes the standard requirements of these five fields.This study also proposes a standard plan.Finally,it summarizes the research report and provides suggestions for a follow-up work.展开更多
In the past decade,several efforts around the world were started with the goal of introducing "smart metering" capabilities into the power grid.These efforts have spurred renewed interest in the design of ne...In the past decade,several efforts around the world were started with the goal of introducing "smart metering" capabilities into the power grid.These efforts have spurred renewed interest in the design of next generation Narrowband Power Line Communications(NB-PLC) transceivers.In the past few years,ITU-T and IEEE have standardized a family of next generation OFDM-based NB-PLC transceivers some of which are today being considered for massive deployments in Europe and Asia.This paper addresses the important role that PLC has not only for smart metering but also for many other Smart Grid applications,and also gives an overview of the main differences between these next generation NB-PLC standards.展开更多
This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality i...This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality indices, unknown until now. This work contributes with the search of a low cost devices PQ meter for a cost sensitive market, and introduces the new Brazilian Power Quality Standard to the international community.展开更多
The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electr...The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electrical energy. We used two TSA control models which differ in the method of disturbed currents detection, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives more promising results than the linear control method. When connecting a non-linear load (televisions, lamps, variable speed drives, etc.) directly to the public distribution network, the non-linear nature of the load causes the source current to be deformed due to the presence of harmonic currents and voltages. These harmonics thus generate a high reactive power, and therefore considerable electrical losses in the network. One of the solutions to reduce losses on the electricity grid is to incorporate an electronic circuit called a filter into the electricity grid. This work carried out a comparative study of two types of control of a three-phase shunt active filter (TSAF) in order to carry out a system for cleaning up electricity networks in order to improve the quality of electrical energy. We used two TSA control models that differ in the method of detecting disturbed currents, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives better results than the linear control method.展开更多
Under the background of implementing renewable portfolio standards and the ever-improving tradable green certificate scheme,the increasingly environmentally-friendly preference of power users is leading to changes in ...Under the background of implementing renewable portfolio standards and the ever-improving tradable green certificate scheme,the increasingly environmentally-friendly preference of power users is leading to changes in electricity demand,which,in turn,is driving changes in the decision-making behaviors of various actors in the power supply chain.Based on this,with the goal of pursuing maximum profit,consumer-power-demand functions have been introduced with some consideration of the factors of consumer preference to establish an optimal profit model for each trading subject in non-cooperative states of the power supply chain,under the constraints of meeting renewable energy portfolio standards.Here,the optimal strategy of each trading subject is presented by adopting the reverse induction method.Furthermore,examples are used to analyze factors such as the influence of environmental protection preferences,quota ratios,price substitutions,and market demand as well as the optimal profit of each trading subject in view of providing a reference for the decision-making in the power supply chain trading subjects.展开更多
Appropriate wind power integration standards are of great importance to standardize wind power integration and guarantee the safety and stability of the power system. This article describes the wind power integration ...Appropriate wind power integration standards are of great importance to standardize wind power integration and guarantee the safety and stability of the power system. This article describes the wind power integration standards of China explicitly and explains several important points of the newly revised wind power integration standards of China in comparison with standards of Germany, Denmark, etc. The newly revised standards can meet the technical demand of China's large-scale centralized development of wind power, and guarantee the safety, stability and economy of the grid and wind farm.展开更多
The national standard--Safety Specifications for Power Driven VehiclesOperating on Roads--is the most basic technical regulation for safety and technical management ofmotor vehicles in China. It is the safety and tech...The national standard--Safety Specifications for Power Driven VehiclesOperating on Roads--is the most basic technical regulation for safety and technical management ofmotor vehicles in China. It is the safety and technical basis for the Public Security TrafficControl Dept. to register new vehicles, periodic inspection of vehicles under operation andinspection of vehicles involved in traffic accidents. It is also one of the important technicalbases of our country for compulsory inspection of new vehicles on fi-nalization of its model,ex-works inspection of new vehicles and the inspection of imported motor vehicles. Since the formalcountrywide implementation of GB7258-1997 Safety Specifications for Power Driven Vehicles Operatingon Roads on Jan. 1, 1998, the standard has played a very active role in strengthening the operatingsafety management of motor vehicles, improving the operating safety level of motor vehicles, and insafeguarding road traffic safety, etc. However, along with the rapid and sustainable growth of ournational economy, the number of motor vehicles has increased rapidly, especially privately-ownedautomobiles, so that the incidence of road traffic accidents rises yearly and the road trafficsafety situation is becoming increasingly serious. Therefore, the General Administration of QualitySupervision, Inspection and Quarantine of the People's Republic of China (AQSIQ) and theStandardization Administration of China (SAC) have issued the revised standard GB725 8-2004 SafetySpecifications for Power Driven Vehicles Operating on Roads, which will be put into effect onOctober 1, 2004. The timely revision of this standard is very necessary for upgrading the safety andtechnical requirements for motor vehicles in China.展开更多
This paper briefs the basic objective of pursuing Renewable Portfolio Standard (RPS), puts forward a thinking about the scope and three modes of RPS-implementation in China and enumerates other possible measures, such...This paper briefs the basic objective of pursuing Renewable Portfolio Standard (RPS), puts forward a thinking about the scope and three modes of RPS-implementation in China and enumerates other possible measures, such as public bidding on concession, exemption from value-added tax, to promote wind power exploitation and development.展开更多
Single-poly,576bit non-volatile memory is designed and implemented in an SMIC 0.18μm standard CMOS process for the purpose of reducing the cost and power of passive RFID tag chips. The memory bit cell is designed wit...Single-poly,576bit non-volatile memory is designed and implemented in an SMIC 0.18μm standard CMOS process for the purpose of reducing the cost and power of passive RFID tag chips. The memory bit cell is designed with conventional single-poly pMOS transistors, based on the bi-directional Fowler-Nordheim tunneling effect, and the typical program/erase time is 10ms for every 16bits. A new ,single-ended sense amplifier is proposed to reduce the power dissipation in the current sensing scheme. The average current consumption of the whole memory chip is 0.8μA for the power supply voltage of 1.2V at a reading rate of 640kHz.展开更多
The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is...The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method.展开更多
In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg act...In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective.展开更多
The main goal of this article is to compare traditional three phase system with one wire three-phase system. There are several obvious advantages of one wire system, for example cost, reliability and other. But there ...The main goal of this article is to compare traditional three phase system with one wire three-phase system. There are several obvious advantages of one wire system, for example cost, reliability and other. But there is a problem as well, connected to reactive power in both systems. This article proposes explanation of reactive power emergence in systems SWER, three-phase and in their one wire versions.展开更多
In the context of clean and Low-carbon energy transformation and new power system,China^photovoltaic power generation will usher in great development.Its large-scale access impacts the safe and stable operation of the...In the context of clean and Low-carbon energy transformation and new power system,China^photovoltaic power generation will usher in great development.Its large-scale access impacts the safe and stable operation of the power grid with increasing significance.In order to strengthen the support and Leading roles of the standards,it is urgent to revise the national standard GB/T 29319-2012,Technical requirements for connecting photovoltaic power system to distribution network,based on the current development trend of photovoltaic power generation and power grid transformation needs.This paper firstly interprets the important technical provisions of the standard,then analyzes the problems in its implementation and finally proposes some revision suggestions in terms of grid adaptability,power control and fault crossing,to facilitate safe and orderly development of photovoltaic power generation in China.展开更多
Solar energy is an important renewable energy.Developing photovoltaic power will not only relieve the energy supply-demand contradiction and optimize the energy structure,but also help to restructure this industry.Thi...Solar energy is an important renewable energy.Developing photovoltaic power will not only relieve the energy supply-demand contradiction and optimize the energy structure,but also help to restructure this industry.This paper analyzes the status quo and the development prospects of China's photovoltaic power industry and its existing issues,and puts forward some suggestions and solutions for its healthy and orderly development.展开更多
This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in t...This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading effect on the alternator introduces harmonic currents and increases the alternator apparent power requirements. To overcome these problems and aiming more stability and better design of the alternator, a new third harmonic injection technique is proposed. This technique allows to preserve a good THD (Total Harmonic Distortion) of the input source at any frequency and to decrease losses in semiconductors switches, thereby allowing more stability and reducing the apparent power requirements. A comparative study between the standard and the new technique is made and highlights the effectiveness of the new design. A detailed analysis of the proposed topology is presented and simulations as well as experimental results are shown.展开更多
文摘For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result.
基金This study is supported by the National Natural Science Foundation of China(No.61801019).
文摘The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the unbalance occurs,the safe operation of the electrical equipment will be seriously jeopardized.This paper proposes a Hierarchical Temporal Memory(HTM)-based three-phase unbalance prediction model consisted by the encoder for binary coding,the spatial pooler for frequency pattern learning,the temporal pooler for pattern sequence learning,and the sparse distributed representations classifier for unbalance prediction.Following the feasibility of spatial-temporal streaming data analysis,we adopted this brain-liked neural network to a real-time prediction for power load.We applied the model in five cities(Tangshan,Langfang,Qinhuangdao,Chengde,Zhangjiakou)of north China.We experimented with the proposed model and Long Short-term Memory(LSTM)model and analyzed the predict results and real currents.The results show that the predictions conform to the reality;compared to LSTM,the HTM-based prediction model shows enhanced accuracy and stability.The prediction model could serve for the overload warning and the load planning to provide high-quality power grid operation.
基金This research was supported by the Science and Technology Plan Project of Sichuan Province(No.21YYJC3324)the Science and Technology Plan Project of Sichuan Province(No.2022YFQ0104).
文摘A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%.
基金National Natural Science Foundation of China(Nos.51767013,52067013)。
文摘In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results.
文摘This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation.
基金supported by Science and Technology Foundation of State Grid Corporation of China(Ubiquitous Power Internet of Things Technical Standard System)5442HL 190008National Key Research and Development Program of China(2020YFB0905900)。
文摘The ubiquitous power Internet of Things(UPIoT)is an intelligent service system with comprehensive state perception,efficient processing,and flexible application of information.It focuses on each link of the power system and makes full use of the mobile internet,artificial intelligence,and other advanced information and communication technologies in order to realize the inter-human interaction of all things in all links of the power system.This article systematically presents to the national and international organizations and agencies in charge of UPIoT layer standardization the status quo of the research on the Internet of Things(IoT)-related industry standards system.It briefly describes the generic standard classification methods,layered architecture,conceptual model,and system tables in the UPIoT application layer.Based on the principles of inheritance,innovation,and practicability,this study divides the application layer into customer service,power grid operation,integrated energy,and enterprise operation,emerging business and analyzes the standard requirements of these five fields.This study also proposes a standard plan.Finally,it summarizes the research report and provides suggestions for a follow-up work.
文摘In the past decade,several efforts around the world were started with the goal of introducing "smart metering" capabilities into the power grid.These efforts have spurred renewed interest in the design of next generation Narrowband Power Line Communications(NB-PLC) transceivers.In the past few years,ITU-T and IEEE have standardized a family of next generation OFDM-based NB-PLC transceivers some of which are today being considered for massive deployments in Europe and Asia.This paper addresses the important role that PLC has not only for smart metering but also for many other Smart Grid applications,and also gives an overview of the main differences between these next generation NB-PLC standards.
文摘This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality indices, unknown until now. This work contributes with the search of a low cost devices PQ meter for a cost sensitive market, and introduces the new Brazilian Power Quality Standard to the international community.
文摘The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electrical energy. We used two TSA control models which differ in the method of disturbed currents detection, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives more promising results than the linear control method. When connecting a non-linear load (televisions, lamps, variable speed drives, etc.) directly to the public distribution network, the non-linear nature of the load causes the source current to be deformed due to the presence of harmonic currents and voltages. These harmonics thus generate a high reactive power, and therefore considerable electrical losses in the network. One of the solutions to reduce losses on the electricity grid is to incorporate an electronic circuit called a filter into the electricity grid. This work carried out a comparative study of two types of control of a three-phase shunt active filter (TSAF) in order to carry out a system for cleaning up electricity networks in order to improve the quality of electrical energy. We used two TSA control models that differ in the method of detecting disturbed currents, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives better results than the linear control method.
基金supported by Project of Philosophy and Social Science Foundation of Shanghai,China(Grant No.2020BGL011).
文摘Under the background of implementing renewable portfolio standards and the ever-improving tradable green certificate scheme,the increasingly environmentally-friendly preference of power users is leading to changes in electricity demand,which,in turn,is driving changes in the decision-making behaviors of various actors in the power supply chain.Based on this,with the goal of pursuing maximum profit,consumer-power-demand functions have been introduced with some consideration of the factors of consumer preference to establish an optimal profit model for each trading subject in non-cooperative states of the power supply chain,under the constraints of meeting renewable energy portfolio standards.Here,the optimal strategy of each trading subject is presented by adopting the reverse induction method.Furthermore,examples are used to analyze factors such as the influence of environmental protection preferences,quota ratios,price substitutions,and market demand as well as the optimal profit of each trading subject in view of providing a reference for the decision-making in the power supply chain trading subjects.
文摘Appropriate wind power integration standards are of great importance to standardize wind power integration and guarantee the safety and stability of the power system. This article describes the wind power integration standards of China explicitly and explains several important points of the newly revised wind power integration standards of China in comparison with standards of Germany, Denmark, etc. The newly revised standards can meet the technical demand of China's large-scale centralized development of wind power, and guarantee the safety, stability and economy of the grid and wind farm.
文摘The national standard--Safety Specifications for Power Driven VehiclesOperating on Roads--is the most basic technical regulation for safety and technical management ofmotor vehicles in China. It is the safety and technical basis for the Public Security TrafficControl Dept. to register new vehicles, periodic inspection of vehicles under operation andinspection of vehicles involved in traffic accidents. It is also one of the important technicalbases of our country for compulsory inspection of new vehicles on fi-nalization of its model,ex-works inspection of new vehicles and the inspection of imported motor vehicles. Since the formalcountrywide implementation of GB7258-1997 Safety Specifications for Power Driven Vehicles Operatingon Roads on Jan. 1, 1998, the standard has played a very active role in strengthening the operatingsafety management of motor vehicles, improving the operating safety level of motor vehicles, and insafeguarding road traffic safety, etc. However, along with the rapid and sustainable growth of ournational economy, the number of motor vehicles has increased rapidly, especially privately-ownedautomobiles, so that the incidence of road traffic accidents rises yearly and the road trafficsafety situation is becoming increasingly serious. Therefore, the General Administration of QualitySupervision, Inspection and Quarantine of the People's Republic of China (AQSIQ) and theStandardization Administration of China (SAC) have issued the revised standard GB725 8-2004 SafetySpecifications for Power Driven Vehicles Operating on Roads, which will be put into effect onOctober 1, 2004. The timely revision of this standard is very necessary for upgrading the safety andtechnical requirements for motor vehicles in China.
文摘This paper briefs the basic objective of pursuing Renewable Portfolio Standard (RPS), puts forward a thinking about the scope and three modes of RPS-implementation in China and enumerates other possible measures, such as public bidding on concession, exemption from value-added tax, to promote wind power exploitation and development.
文摘Single-poly,576bit non-volatile memory is designed and implemented in an SMIC 0.18μm standard CMOS process for the purpose of reducing the cost and power of passive RFID tag chips. The memory bit cell is designed with conventional single-poly pMOS transistors, based on the bi-directional Fowler-Nordheim tunneling effect, and the typical program/erase time is 10ms for every 16bits. A new ,single-ended sense amplifier is proposed to reduce the power dissipation in the current sensing scheme. The average current consumption of the whole memory chip is 0.8μA for the power supply voltage of 1.2V at a reading rate of 640kHz.
基金Project(2012AA051601)supported by the High-Tech Research and Development Program of China
文摘The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method.
文摘In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective.
文摘The main goal of this article is to compare traditional three phase system with one wire three-phase system. There are several obvious advantages of one wire system, for example cost, reliability and other. But there is a problem as well, connected to reactive power in both systems. This article proposes explanation of reactive power emergence in systems SWER, three-phase and in their one wire versions.
文摘In the context of clean and Low-carbon energy transformation and new power system,China^photovoltaic power generation will usher in great development.Its large-scale access impacts the safe and stable operation of the power grid with increasing significance.In order to strengthen the support and Leading roles of the standards,it is urgent to revise the national standard GB/T 29319-2012,Technical requirements for connecting photovoltaic power system to distribution network,based on the current development trend of photovoltaic power generation and power grid transformation needs.This paper firstly interprets the important technical provisions of the standard,then analyzes the problems in its implementation and finally proposes some revision suggestions in terms of grid adaptability,power control and fault crossing,to facilitate safe and orderly development of photovoltaic power generation in China.
文摘Solar energy is an important renewable energy.Developing photovoltaic power will not only relieve the energy supply-demand contradiction and optimize the energy structure,but also help to restructure this industry.This paper analyzes the status quo and the development prospects of China's photovoltaic power industry and its existing issues,and puts forward some suggestions and solutions for its healthy and orderly development.
文摘This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading effect on the alternator introduces harmonic currents and increases the alternator apparent power requirements. To overcome these problems and aiming more stability and better design of the alternator, a new third harmonic injection technique is proposed. This technique allows to preserve a good THD (Total Harmonic Distortion) of the input source at any frequency and to decrease losses in semiconductors switches, thereby allowing more stability and reducing the apparent power requirements. A comparative study between the standard and the new technique is made and highlights the effectiveness of the new design. A detailed analysis of the proposed topology is presented and simulations as well as experimental results are shown.