Prediction of Core Losses of Three-Phase Distribution Transformer
1
作者 Mihail Digalovski Krste Najdenkoski Goran Rafajlovski 《Journal of Energy and Power Engineering》 2013年第12期2347-2353,共7页
Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additi... Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in transformer parts. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these problems, the rated capacity of transformer which supplies harmonic loads must be reduced. In this work, a typical 50 kVA three-phase distribution transformer with real practical parameters is taken under non-linear loads generated due to domestic loads. The core losses is evaluated using the three dimensional model of the transformer developed in FEM (finite element method) program based on valid model of transformer under high harmonic conditions. And finally a relation associated with core losses and amplitude of high harmonic order are reviewed & analyzed and then a comparison is being carried out on the results obtained by different excitation current in transformer windings. 展开更多
关键词 Core losses three-phase transformer HARMONIC 3D model finite element method magnetic flux distribution.
下载PDF
Analysis of the flow pattern and periodicity of gas–liquid–liquid three-phase flow in a countercurrent mixer-settler
2
作者 Minghang Zhang Wangfeng Cai +2 位作者 Pei Zhu Le Xie Yan Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第11期135-145,共11页
In contrast to the concurrent mixer-settler,the interaction between the mixing and settling chambers have to be taken into account in the simulation of the countercurrent mixer-settler,and no work has been reported fo... In contrast to the concurrent mixer-settler,the interaction between the mixing and settling chambers have to be taken into account in the simulation of the countercurrent mixer-settler,and no work has been reported for this equipment.In this work,a three-phase flow model based on the Eulerian multiphase model,coupled with a sliding mesh model is proposed for a countercurrent mixer-settler.Based on this,the dispersed phase distribution,flow pattern,and pressure distribution are investigated,which can help to fill the gap in the operation mechanism.In addition,the velocity vector distribution at the phase port shows an intriguing phenomenon that two types of vectors with opposite directions are distributed on the left and right sides of the same plane,which indicates that the material exchange in the mixing and settling chambers is simultaneous.Analysis of this variation at this location by a fast Fourier transform(FFT)method reveals that it is mainly influenced by the mixing chamber and is consistent with the main period of the outlet flow fluctuations.Therefore,by monitoring the fluctuation of the outlet flow and then analyzing it by the FFT method,the state of the whole tank can be determined,which makes it promising for the design of control systems for countercurrent mixer-settlers. 展开更多
关键词 Countercurrent mixer-settler three-phase flow Sliding mesh model(SMM) Fast Fourier transform(FFT)
下载PDF
Voltage Profile Enhancement and Power Loss Reduction with Economic Feasibility Using Small Capacity Distribution Transformers
3
作者 Rasool M.Imran Mohammed R.Saeed +5 位作者 Mohammed Amer Mohammed Osama A.Suhry Ihsan H.Abdulqadder Hasan Wahhab Salih Mohammed R.Almallah Firas M.F.Flaih 《Energy Engineering》 EI 2022年第6期2447-2467,共21页
Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop f... Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months. 展开更多
关键词 Single-phase pole-mounted transformer three-phase transformer power losses voltage profile distribution networks
下载PDF
Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection 被引量:3
4
作者 Zhifeng Zhang Yue Wu +1 位作者 Hequn Su Quanzeng Sun 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期306-314,共9页
This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transforma... This paper proposes a novel control approach for fault-tolerant control of dual three-phase permanent magnet synchronous motor(PMSM) under one-phase open-circuit fault.A modified six-phase static coordinate transformation matrix and an extended rotating coordinate transformation matrix are investigated considering the influence of the fifth harmonic space on fault-tolerant control. These mathematical models are further analyzed in the fundamental space and the fifth harmonic space after the fault and to eliminate the coupling between the d-q axis voltage equation in the fundamental wave space and the d-q axis voltage equation in the fifth harmonic space, a secondary rotation coordinate transformation matrix is proposed. To achieve the purpose of reducing torque ripple, the fault-tolerant control method proposed in this paper not only takes the minimum copper loss as the constraint condition, but also injects the fifth harmonic current. The experimental result of current and torque is used to verify the accuracy of fault-tolerant control. 展开更多
关键词 Extended rotating coordinate transformation matrix Fault-tolerant control Fifth harmonic current injection Modified six-phase static coordinate transformation matrix Dual three-phase permanent magnet synchronous motor Torque ripple
下载PDF
Grid-Connected PV Solar Energy Converter with Active and Reactive Power Control
5
作者 Roberto F. Coelho Artur Pagnoncelli Galbiatti Denizar Cruz Martins 《Journal of Energy and Power Engineering》 2014年第2期331-342,共12页
This work proposes a 12 kW three-phase grid-connected single stage PWM DC-AC converter destined to process the energy provided by a photovoltaic array composed of 57 KC200GT PV modules with high power factor for any s... This work proposes a 12 kW three-phase grid-connected single stage PWM DC-AC converter destined to process the energy provided by a photovoltaic array composed of 57 KC200GT PV modules with high power factor for any solar radiation. The PWM inverter modeling and the control strategy, using dqO transformation, are proposed in order to also allow the system operation as an active power filter, capable to compensate harmonic components and react power generated by the non-linear loads connected to the mains grid. An input voltage clamping technique is proposed to impose the photovoltaic operation on the maximum power point. Simulation and experimental results are presented to validate the proposed methodology for grid connected photovoltaic generation system. 展开更多
关键词 Active and reactive power dqO transformation grid-connected PV systems three-phase DC-AC PWM converter.
下载PDF
Power Flow Model for Medium-voltage Distribution Systems Considering Measurement and Structure Characteristics
6
作者 Zhengmei Lu Wei Yan +3 位作者 Dezhi Huang Junjie Tang Ferdinanda Ponci Antonello Monti 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期571-583,共13页
Medium-voltage distribution systems(MVDSs)mainly consist of a feeder head,lines,distribution transformers,and the equivalent load or power supply interfaced with the distribution transformers.The information of such l... Medium-voltage distribution systems(MVDSs)mainly consist of a feeder head,lines,distribution transformers,and the equivalent load or power supply interfaced with the distribution transformers.The information of such load or power supply can be measured via the three-wattmeter method(THM)and the two-wattmeter method(TWM).The measurements can be used to perform the control of the power supply and simulate the characteristics of the load,so the models of the load and the power supply need to consider the measurement characteristics.Existing research works on three-phase power flow(PF)just consider the measurement characteristics of THM.Hence,the PF equation of the bus measured via TWM is firstly built.Based on conventional measurements,an accurate and general model of the grounded and ungrounded slack bus is proposed.Furthermore,the influence arising from the connection type and angle shift of distribution transformers on the admittance matrix is considered,and thus a general three-phase transformer model is summarized,which is applicable for all the transformers mentioned herein.Finally,Newton's method is adopted to solve the PF calculation,and the performance of the proposed PF model is demonstrated through designed tests. 展开更多
关键词 Medium-voltage distribution system three-phase power flow calculation measurement characteristic slack bus modeling distribution transformer