Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying availabl...Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying available cold wind in cold regions.This is achieved by a static heat transfer device called thermosyphon equipped with an air insulation layer.A refrigeration unit can be optionally integrated to meet additional cooling requirements.The introduction of air insulation isolates the thermosyphon from ground zones where freezing is not needed,resulting in:(1)steering the cooling resources(cold wind or refrigeration)towards zones of interest;and(2)minimizing refrigeration load.This design is demonstrated using well-validated mathematical models from our previous work based on two-phase enthalpy method of the ground coupled with a thermal resistance network for the thermosyphon.Two Canadian mines are considered:the Cigar Lake Mine and the Giant Mine.The results show that our proposed design can speed the freezing time by 30%at the Giant Mine and by two months at the Cigar Lake Mine.Further,a cooling load of 2.4 GWh can be saved at the Cigar Lake Mine.Overall,this study provides mining practitioners with sustainable solutions of underground AGF.展开更多
An in-depth investigation is made on the problem of an arc-shapedinterface insulating crack in a three-phase concentric circularcylindrical piezoelectric composite constitutive model. An exactsolution in series form i...An in-depth investigation is made on the problem of an arc-shapedinterface insulating crack in a three-phase concentric circularcylindrical piezoelectric composite constitutive model. An exactsolution in series form is derived by employing the complex variablemethod. In addition, the distribution of physical quantities such asstresses, strains, electric displacements and electric fields in thewhole field and along the interface is also presented.展开更多
On the basis of on-site measured data of the newly constructed Gonghe-Yushu Highway in a permafrost region, this paper analyzed thermal conditions of the subgrade with XPS insulated board according to different select...On the basis of on-site measured data of the newly constructed Gonghe-Yushu Highway in a permafrost region, this paper analyzed thermal conditions of the subgrade with XPS insulated board according to different selected monitoring sections in various locations. We also summarized the geothermal distribution and change rules of subgrade with XPS insulation board under the asphalt pavement in summarized a high temperature frozen soil region. It is suggested that the shoulder of subgrade with XPS insulation board be widen to a reasonable width so as to keep the subgrade stable.展开更多
Today the entire globe is shrouded in an inefficient three-phase system. There is however an efficient single-wire system. To use the single wire method, three phase systems can be converted to triple one wire systems.
This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire usi...This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.展开更多
文摘Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying available cold wind in cold regions.This is achieved by a static heat transfer device called thermosyphon equipped with an air insulation layer.A refrigeration unit can be optionally integrated to meet additional cooling requirements.The introduction of air insulation isolates the thermosyphon from ground zones where freezing is not needed,resulting in:(1)steering the cooling resources(cold wind or refrigeration)towards zones of interest;and(2)minimizing refrigeration load.This design is demonstrated using well-validated mathematical models from our previous work based on two-phase enthalpy method of the ground coupled with a thermal resistance network for the thermosyphon.Two Canadian mines are considered:the Cigar Lake Mine and the Giant Mine.The results show that our proposed design can speed the freezing time by 30%at the Giant Mine and by two months at the Cigar Lake Mine.Further,a cooling load of 2.4 GWh can be saved at the Cigar Lake Mine.Overall,this study provides mining practitioners with sustainable solutions of underground AGF.
基金the National Natural Science Foundation of China(No.59635140)the Doctorate Foundation of Xi'an Jiaotong University
文摘An in-depth investigation is made on the problem of an arc-shapedinterface insulating crack in a three-phase concentric circularcylindrical piezoelectric composite constitutive model. An exactsolution in series form is derived by employing the complex variablemethod. In addition, the distribution of physical quantities such asstresses, strains, electric displacements and electric fields in thewhole field and along the interface is also presented.
基金supported by the National Key Basic Research Program of China 973 Project(No.2012CB026104)National Natural Science Foundation of China(No.41271072 and No.51378057)Service Performance Evaluation of the Subsidiary Structure in The Permafrost Regions of the Qinghai Tibet Plateau(2014-07-01)
文摘On the basis of on-site measured data of the newly constructed Gonghe-Yushu Highway in a permafrost region, this paper analyzed thermal conditions of the subgrade with XPS insulated board according to different selected monitoring sections in various locations. We also summarized the geothermal distribution and change rules of subgrade with XPS insulation board under the asphalt pavement in summarized a high temperature frozen soil region. It is suggested that the shoulder of subgrade with XPS insulation board be widen to a reasonable width so as to keep the subgrade stable.
文摘Today the entire globe is shrouded in an inefficient three-phase system. There is however an efficient single-wire system. To use the single wire method, three phase systems can be converted to triple one wire systems.
文摘This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator.