The electroslag remelting(ESR)process is widely used to produce high-quality ingots and billets for high-alloyed steels and alloys.Both the single-phase and three-phase alternating current diagram with bifilar and mon...The electroslag remelting(ESR)process is widely used to produce high-quality ingots and billets for high-alloyed steels and alloys.Both the single-phase and three-phase alternating current diagram with bifilar and monofilar connection are in use for heavy ingot manufacturing.The numerical simulation of the three-phase bifilar circuit for the 120 t three-phase bifilar six-electrode ESR furnace at different variants of electric connection was presented and discussed.At the bifilar diagram of power supply,the geometrical location of electrodes in a mould holds critical importance for performances:the close location of bifilar pair electrodes provides the highest heat productivity,but the equidistant location of electrodes gives a much more uniform heat distribution.The monofilar mulit-electrode diagram of three-phase connection without phase shift shows the most uniform distribution of potential and heat generation as well as a favorable magnetic field that makes this kind the most promising for providing a high quality of heavy ingots.展开更多
作为一种典型多端口变换器,三有源桥(triple active bridge,TAB)DC-DC变换器广泛应用于分布式直流系统中,其开关器件开路故障将严重影响系统运行。为降低开关故障带来的影响,该文提出TAB变换器开路故障诊断方法与容错运行策略。首先,分...作为一种典型多端口变换器,三有源桥(triple active bridge,TAB)DC-DC变换器广泛应用于分布式直流系统中,其开关器件开路故障将严重影响系统运行。为降低开关故障带来的影响,该文提出TAB变换器开路故障诊断方法与容错运行策略。首先,分析TAB变换器正常运行特性以及开关管开路故障暂态过程,提出利用TAB变换器各桥臂中点电压平均值实现开路故障定位。通过闭锁故障开关所在桥臂的驱动信号消除开路故障导致的直流偏置;然后,分析闭锁状态下TAB变换器的运行特性,确定能够保证TAB变换器实现开路故障容错运行的移相角范围,当开路故障发生于直流母线侧,调节移相角使得直流母线吸收功率,当开路故障发生于储能侧时,调节移相角使故障储能切除。实验结果验证所提方法可准确快速实现各开关管开路故障诊断,并实现容错运行,提升TAB变换器的可靠性。展开更多
为将真空断路器应用于更高电压等级,多断口真空断路器的研究成为行业内的热点问题。在分析总结此前研究成果的基础上,设计了一种由3个光控真空断路器模块(FCVIM)串联组成的126 k V真空断路器。断路器按照U形方式串联光控真空断路器模块...为将真空断路器应用于更高电压等级,多断口真空断路器的研究成为行业内的热点问题。在分析总结此前研究成果的基础上,设计了一种由3个光控真空断路器模块(FCVIM)串联组成的126 k V真空断路器。断路器按照U形方式串联光控真空断路器模块,光控真空断路器模块主要由外绝缘部件、真空灭弧室、均压电容、永磁操动机构及其控制器和操动电源等部分组成,在低电位通过光纤控制技术对工作于高电位的永磁操动机构进行控制。对三断口真空断路器和单断口真空断路器模块分别施加雷电冲击电压,结果显示三断口真空断路器相对单断口真空断路器的击穿电压增益倍数为1.59;在并联不同均压电容和人为制造三断口不同步分断情况下研究三断口真空断路器暂态电压分布特性,发现低分散性操动机构和均压电容的应用可以有效提高其开断能力。三断口真空断路器在额定电压下成功开断40 k A短路电流,在不同试验方式下完成重合闸操作,并已顺利通过挂网试运行。展开更多
超高压(extra high voltage,EHV)同塔三回线路复杂的电磁耦合给其零序参数的精确测量带来极大的挑战。该文总结了现有的零序参数测量方法,分析了各测量方法的优缺点。在此基础上提出了一种基于双端同步测量的EHV同塔三回线路零序参数的...超高压(extra high voltage,EHV)同塔三回线路复杂的电磁耦合给其零序参数的精确测量带来极大的挑战。该文总结了现有的零序参数测量方法,分析了各测量方法的优缺点。在此基础上提出了一种基于双端同步测量的EHV同塔三回线路零序参数的精确测量方法。建立了长距离EHV同塔三回线路的分布参数模型,推导了利用双端同步测量信息的同塔三回线路传输线方程的求解公式,给出了同塔三回线路的测量接线方式和零序参数的测量步骤,利用PSCAD/EMTDC验证了所提测量方法的准确性,并与传统测量方法进行了对比。仿真结果表明:传统方法测量精度低,改进的传统方法能提高短距离输电线路的测量精度,但应用于200km及以上的线路的零序参数测量会造成很大的误差,而该文提出的测量方法在测量精度和测量效率上都有很大的提高,能够满足实际工程的需求。展开更多
文摘The electroslag remelting(ESR)process is widely used to produce high-quality ingots and billets for high-alloyed steels and alloys.Both the single-phase and three-phase alternating current diagram with bifilar and monofilar connection are in use for heavy ingot manufacturing.The numerical simulation of the three-phase bifilar circuit for the 120 t three-phase bifilar six-electrode ESR furnace at different variants of electric connection was presented and discussed.At the bifilar diagram of power supply,the geometrical location of electrodes in a mould holds critical importance for performances:the close location of bifilar pair electrodes provides the highest heat productivity,but the equidistant location of electrodes gives a much more uniform heat distribution.The monofilar mulit-electrode diagram of three-phase connection without phase shift shows the most uniform distribution of potential and heat generation as well as a favorable magnetic field that makes this kind the most promising for providing a high quality of heavy ingots.
文摘作为一种典型多端口变换器,三有源桥(triple active bridge,TAB)DC-DC变换器广泛应用于分布式直流系统中,其开关器件开路故障将严重影响系统运行。为降低开关故障带来的影响,该文提出TAB变换器开路故障诊断方法与容错运行策略。首先,分析TAB变换器正常运行特性以及开关管开路故障暂态过程,提出利用TAB变换器各桥臂中点电压平均值实现开路故障定位。通过闭锁故障开关所在桥臂的驱动信号消除开路故障导致的直流偏置;然后,分析闭锁状态下TAB变换器的运行特性,确定能够保证TAB变换器实现开路故障容错运行的移相角范围,当开路故障发生于直流母线侧,调节移相角使得直流母线吸收功率,当开路故障发生于储能侧时,调节移相角使故障储能切除。实验结果验证所提方法可准确快速实现各开关管开路故障诊断,并实现容错运行,提升TAB变换器的可靠性。
文摘为将真空断路器应用于更高电压等级,多断口真空断路器的研究成为行业内的热点问题。在分析总结此前研究成果的基础上,设计了一种由3个光控真空断路器模块(FCVIM)串联组成的126 k V真空断路器。断路器按照U形方式串联光控真空断路器模块,光控真空断路器模块主要由外绝缘部件、真空灭弧室、均压电容、永磁操动机构及其控制器和操动电源等部分组成,在低电位通过光纤控制技术对工作于高电位的永磁操动机构进行控制。对三断口真空断路器和单断口真空断路器模块分别施加雷电冲击电压,结果显示三断口真空断路器相对单断口真空断路器的击穿电压增益倍数为1.59;在并联不同均压电容和人为制造三断口不同步分断情况下研究三断口真空断路器暂态电压分布特性,发现低分散性操动机构和均压电容的应用可以有效提高其开断能力。三断口真空断路器在额定电压下成功开断40 k A短路电流,在不同试验方式下完成重合闸操作,并已顺利通过挂网试运行。
文摘超高压(extra high voltage,EHV)同塔三回线路复杂的电磁耦合给其零序参数的精确测量带来极大的挑战。该文总结了现有的零序参数测量方法,分析了各测量方法的优缺点。在此基础上提出了一种基于双端同步测量的EHV同塔三回线路零序参数的精确测量方法。建立了长距离EHV同塔三回线路的分布参数模型,推导了利用双端同步测量信息的同塔三回线路传输线方程的求解公式,给出了同塔三回线路的测量接线方式和零序参数的测量步骤,利用PSCAD/EMTDC验证了所提测量方法的准确性,并与传统测量方法进行了对比。仿真结果表明:传统方法测量精度低,改进的传统方法能提高短距离输电线路的测量精度,但应用于200km及以上的线路的零序参数测量会造成很大的误差,而该文提出的测量方法在测量精度和测量效率上都有很大的提高,能够满足实际工程的需求。