期刊文献+
共找到373篇文章
< 1 2 19 >
每页显示 20 50 100
A Modified Iterative Learning Control Approach for the Active Suppression of Rotor Vibration Induced by Coupled Unbalance and Misalignment
1
作者 Yifan Bao Jianfei Yao +1 位作者 Fabrizio Scarpa Yan Li 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第1期242-253,共12页
This paper proposes a modified iterative learning control(MILC)periodical feedback-feedforward algorithm to reduce the vibration of a rotor caused by coupled unbalance and parallel misalignment.The control of the vibr... This paper proposes a modified iterative learning control(MILC)periodical feedback-feedforward algorithm to reduce the vibration of a rotor caused by coupled unbalance and parallel misalignment.The control of the vibration of the rotor is provided by an active magnetic actuator(AMA).The iterative gain of the MILC algorithm here presented has a self-adjustment based on the magnitude of the vibration.Notch filters are adopted to extract the synchronous(1×Ω)and twice rotational frequency(2×Ω)components of the rotor vibration.Both the notch frequency of the filter and the size of feedforward storage used during the experiment have a real-time adaptation to the rotational speed.The method proposed in this work can provide effective suppression of the vibration of the rotor in case of sudden changes or fluctuations of the rotor speed.Simulations and experiments using the MILC algorithm proposed here are carried out and give evidence to the feasibility and robustness of the technique proposed. 展开更多
关键词 Rotor vibration suppression Modified iterative learning control unbalance Parallel misalignment Active magnetic actuator
下载PDF
Optimization of Control Loops and Operating Parameters for Three-Phase Separators Used in Oilfield Central Processing Facilities
2
作者 Zhenfeng Li Yaqiao Li Guangjun Wei 《Fluid Dynamics & Materials Processing》 EI 2023年第3期635-649,共15页
In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to... In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to)the typical size of oil and water droplets,the residence time and temperature of fluid and the dosage of demulsifier.Using the“Specification for Oil and Gas Separators”as a basis,the control loops and operating parameters of each separator are optimized Considering the Halfaya Oilfield as a testbed,it is shown that the proposed approach can lead to good results in the production stage. 展开更多
关键词 Distributed control system(DCS) three-phase separator control loop operating parameter
下载PDF
Three-Phase Unbalance Prediction of Electric Power Based on Hierarchical Temporal Memory 被引量:1
3
作者 Hui Li Cailin Shi +2 位作者 Xin Liu Aziguli Wulamu Alan Yang 《Computers, Materials & Continua》 SCIE EI 2020年第8期987-1004,共18页
The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the... The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the unbalance occurs,the safe operation of the electrical equipment will be seriously jeopardized.This paper proposes a Hierarchical Temporal Memory(HTM)-based three-phase unbalance prediction model consisted by the encoder for binary coding,the spatial pooler for frequency pattern learning,the temporal pooler for pattern sequence learning,and the sparse distributed representations classifier for unbalance prediction.Following the feasibility of spatial-temporal streaming data analysis,we adopted this brain-liked neural network to a real-time prediction for power load.We applied the model in five cities(Tangshan,Langfang,Qinhuangdao,Chengde,Zhangjiakou)of north China.We experimented with the proposed model and Long Short-term Memory(LSTM)model and analyzed the predict results and real currents.The results show that the predictions conform to the reality;compared to LSTM,the HTM-based prediction model shows enhanced accuracy and stability.The prediction model could serve for the overload warning and the load planning to provide high-quality power grid operation. 展开更多
关键词 three-phase unbalance power load prediction model hierarchical temporal memory
下载PDF
Research of Three-Phase Unbalanced Treatment in Low-Voltage Distribution Network Based on New Commutation Switch 被引量:1
4
作者 Xue Liu Jun Jia Jian Wang 《World Journal of Engineering and Technology》 2019年第4期10-17,共8页
Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance i... Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance in low-voltage distribution system, and seriously affect the quality of power supply. A new type of the commutation system and an improved quantum genetic algorithm (IQGA) are proposed in the paper. At last, the rationality and the efficiency of the method are verified by a practical example. 展开更多
关键词 LOW-VOLTAGE DISTRIBUTION Network three-phase unbalance COMMUTATION SWITCH IQGA
下载PDF
Speed Regulation Method Using Genetic Algorithm for Dual Three-phase Permanent Magnet Synchronous Motors 被引量:1
5
作者 Xiuhong Jiang Yuying Wang Jiarui Dong 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期171-178,共8页
Dual three-phase Permanent Magnet Synchronous Motor(DTP-PMSM)is a nonlinear,strongly coupled,high-order multivariable system.In today’s application scenarios,it is difficult for traditional PI controllers to meet the... Dual three-phase Permanent Magnet Synchronous Motor(DTP-PMSM)is a nonlinear,strongly coupled,high-order multivariable system.In today’s application scenarios,it is difficult for traditional PI controllers to meet the requirements of fast response,high accuracy and good robustness.In order to improve the performance of DTP-PMSM speed regulation system,a control strategy of PI controller based on genetic algorithm is proposed.Firstly,the basic mathematical model of DTP-PMSM is established,and the PI parameters of DTP-PMSM speed regulation system are optimized by genetic algorithm,and the modeling and simulation experiments of DTP-PMSM control system are carried out by MATLAB/SIMULINK.The simulation results show that,compared with the traditional PI control,the proposed algorithm significantly improves the performance of the control system,and the speed output overshoot of the GA-PI speed control system is smaller.The anti-interference ability is stronger,and the torque and double three-phase current output fluctuations are smaller. 展开更多
关键词 Dual three-phase permanent magnet synchronous motor Genetic algorithm PI control Speed regulation
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
6
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
Comparative Study of Linear and Non-Linear Controls of Three-Phase Shunt Active Filters for Improving the Quality of Electrical Energy
7
作者 Mamane Adamou Nabil Alkassoum +1 位作者 André Foulani Amadou Seidou Maiga 《Energy and Power Engineering》 2019年第3期149-166,共18页
The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electr... The aim of this work is to comparatively study two types of control of a three-phase shunt active filter (TSAF) in order to realize a system of depollution of electrical networks so as to improve the quality of electrical energy. We used two TSA control models which differ in the method of disturbed currents detection, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives more promising results than the linear control method. When connecting a non-linear load (televisions, lamps, variable speed drives, etc.) directly to the public distribution network, the non-linear nature of the load causes the source current to be deformed due to the presence of harmonic currents and voltages. These harmonics thus generate a high reactive power, and therefore considerable electrical losses in the network. One of the solutions to reduce losses on the electricity grid is to incorporate an electronic circuit called a filter into the electricity grid. This work carried out a comparative study of two types of control of a three-phase shunt active filter (TSAF) in order to carry out a system for cleaning up electricity networks in order to improve the quality of electrical energy. We used two TSA control models that differ in the method of detecting disturbed currents, one linear and the other non-linear. The results show that the non-linear control method, although with high calculation blocks, gives better results than the linear control method. 展开更多
关键词 Power QUALITY Active three-phase SHUNT Filter NON-LINEAR control LINEAR control
下载PDF
Research on a New Control Strategy of Three Phase Inverter for Unbalanced Loads
8
作者 Wenhua HU Weiming Ma Chunxi LIU 《Journal of Electromagnetic Analysis and Applications》 2010年第1期39-44,共6页
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing... One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms. 展开更多
关键词 three-phase INVERTER unbalanced Load the three-phase OUTPUT Voltage SYMMETRIC Medium Frequency P+Resonant controlLER
下载PDF
Sliding mode control of three-phase AC/DC converters using exponential rate reaching law
9
作者 JEERANANTASIN Narin NUNGAM Suksun 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2022年第1期210-221,共12页
Sliding mode control(SMC) becomes a common tool in designing robust nonlinear control systems, due to its inherent characteristics such as insensitivity to system uncertainties and fast dynamic response.Two modes are ... Sliding mode control(SMC) becomes a common tool in designing robust nonlinear control systems, due to its inherent characteristics such as insensitivity to system uncertainties and fast dynamic response.Two modes are involved in the SMC operation, namely reaching mode and sliding mode.In the reaching mode, the system state is forced to reach the sliding surface in a finite time.The major drawback of the SMC approach is the occurrence of chattering in the sliding mode, which is undesirable in most applications.Generally, the trade-off between chattering reduction and fast reaching time must be considered in the conventional SMC design.This paper proposes SMC design with a novel reaching law called the exponential rate reaching law(ERRL) to reduce chattering, and the control structure of the converter is designed based on the multiinput SMC that is applied to a three-phase AC/DC power converter.The simulation and experimental results show the effectiveness of the proposed technique. 展开更多
关键词 exponential rate reaching law(ERRL) multi-input sliding mode control(SMC) chattering reduction three-phase AC-to-DC converter
下载PDF
Predictive direct power control of three-phase PWM rectifier based on TOGI grid voltage sensor free algorithm
10
作者 ZHAO Feng LI Shute +4 位作者 CHEN Xiaoqiang WANG Ying GAN Yanqi NIU Xinqiang ZHANG Fan 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第4期451-459,共9页
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i... In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results. 展开更多
关键词 three-phase PWM rectifier predictive direct power control grid voltage sensor free algorithm third-order generalized integrator power correction
下载PDF
Vector Control of Three-Phase Solar Farm Converters Based on Fictive-Axis Emulation
11
作者 Kai Kang Qiaoyu Wang Jiayi Meng 《Journal of Computer Science Research》 2020年第3期10-13,共4页
In this paper,a new method for adjusting the current of three-phase voltage source DC-AC converter in orthogonal(DQ)reference frame is presented.In the DQ reference system,AC variable appears in the constant form of D... In this paper,a new method for adjusting the current of three-phase voltage source DC-AC converter in orthogonal(DQ)reference frame is presented.In the DQ reference system,AC variable appears in the constant form of DC,making the controller design the same as the DC-DC converter[1].It provides controllable gain benefits at the steady-state operating point,and finally realizes zero steady-state error[2].In addition,the creative analytical model is dedicated to building up a series of virtual quantities orthogonal to the actual single-phase system.In general,orthogonal imaginary numbers get the reference signal by delaying the real quantity by a quarter period.However,the introduction of such time delay makes the dynamic response of the system worse.In this paper,orthogonal quantities are generated from a virtual axis system parallel to the real axis,which can effectively improve the dynamic performance of traditional methods without increasing the complexity of controller structure.Through PSCAD simulation,the ideal experimental results are obtained. 展开更多
关键词 Current controller Fictive-axis Emulation(FAE) three-phase voltage-source converters(VSCs) Vector controller
下载PDF
Finite Set-Model Predictive Current Control of Three-Phase Voltage Source Inverter for RES (Renewable Energy Systems) Applications
12
作者 Ali Almaktoof Atanda Raji Tariq Kahn 《Journal of Energy and Power Engineering》 2014年第4期749-756,共8页
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f... This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system. 展开更多
关键词 Finite set-model predictive control three-phase voltage source inverter renewable energy system application AC filter Matlab/Simulink.
下载PDF
Finite control set model predictive control of three-port converter for interfacing a PV-battery energy storage system to a three-phase stand-alone AC system 被引量:1
13
作者 Gangashetty A.Preeti Anbalagan Karthikeyan 《Clean Energy》 EI CSCD 2024年第2期73-84,共12页
This paper proposes a multiport bidirectional non-isolated converter topology that provides advantages in terms of simultaneous multiple operations,single-stage conversion,high power density and reduced power losses d... This paper proposes a multiport bidirectional non-isolated converter topology that provides advantages in terms of simultaneous multiple operations,single-stage conversion,high power density and reduced power losses due to the lower number of switches.The proposed multiport converter uses a centralized non-linear controller known as a finite control set model predictive controller to manage the flow of power between different ports.It deals with the parallel operation of photovoltaic and battery energy storage systems for stand-alone alternating current(AC)systems.The converter connects the lower voltage battery to the photovoltaic port using a bidirectional buck/boost converter and the photovoltaic port is linked to the stand-alone AC load through a three-phase full-bridge inverter.Each leg of the three-phase converter will act as a bidirectional direct current(DC)/DC converter as well as an inverter simultaneously.Only six switches manage the power transfer between all the connected ports of photovoltaic-battery energy storage system linked to the stand-alone AC load.The proposed multiport converter is mathematically modelled and controlled by a finite control set model predictive controller.The system is validated in simulation(1-kW rating)and experimental environment(200-W rating).The hardware prototype is developed in the laboratory and the controller is implemented on the field-programmable gate array board.Two independent case studies are carried out to validate the efficacy of the system.The first scenario is for a change in solar irradiance,while the second scenario is for a change in the output load. 展开更多
关键词 multiport converter DC/AC converter DC/DC converter finite control set model predictive controller(FCSMPC) PV-BESS three-phase converter
原文传递
Unbalance Vibratory Displacement Compensation for Active Magnetic Bearings 被引量:15
14
作者 GAO Hui XU Longxiang ZHU Yili 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第1期95-103,共9页
As the dynamic stiffness of radial magnetic bearings is not big enough, when the rotor spins at high speed, unbalance displacement vibration phenomenon will be produced. The most effective way for reducing the displac... As the dynamic stiffness of radial magnetic bearings is not big enough, when the rotor spins at high speed, unbalance displacement vibration phenomenon will be produced. The most effective way for reducing the displacement vibration is to enhance the radial magnetic bearing stiffness through increasing the control currents, but the suitable control currents are not easy to be provided, especially, to be provided in real time. To implement real time unbalance displacement vibration compensation, through analyzing active magnetic bearings (AMB) mathematical model, the existence of radial displacement runout is demonstrated. To restrain the runout, a new control scheme-adaptive iterative learning control (A1LC) is proposed in view of rotor frequency periodic uncertainties during the startup process. The previous error signal is added into AILC learning law to enhance the convergence speed, and an impacting factor/3 influenced by the rotor rotating frequency is introduced as learning output coefficient to improve the rotor control effects, As a feed-forward compensation controller, AILC can provide one tmknown and perfect compensatory signal to make the rotor rotate around its geometric axis through power amplifier and radial magnetic bearings. To improve AMB closed-loop control system robust stability, one kind of incomplete differential PID feedback controller is adopted. The correctness of the AILC algorithm is validated by the simulation of AMB mathematical model adding AILC compensation algorithm through MATLAB soft. And the compensation for fixed rotational frequency is implemented in the actual AMB system. The simulation and experiment results show that the compensation scheme based on AILC algorithm as feed-forward compensation and PID algorithm as close-loop control can realize AMB system displacement minimum compensation at one fixed frequency, and improve the stability of the control system. The proposed research provides a new adaptive iterative/earning control algorithm and control strategy for AMB displacement minimum compensation, and provides some references for time-varied displacement minimum compensation. 展开更多
关键词 active magnetic bearings unbalance displacement compensation mathematical model adaptive iterative learning control
下载PDF
Distributed Cooperative Secondary Voltage Control in an Unbalanced Microgrid
15
作者 Xiangzhen Yang Haixi Zhao +3 位作者 Mengke Duan Yan Du Haining Wang Jian Zhang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期222-234,共13页
The negative-sequence reactive power-conductance(Q^(−)-G) droop control strategy is a conventional method to compensate for the output unbalanced voltages in an islanded MG.Nevertheless, the conflict between unbalance... The negative-sequence reactive power-conductance(Q^(−)-G) droop control strategy is a conventional method to compensate for the output unbalanced voltages in an islanded MG.Nevertheless, the conflict between unbalanced voltage compensation and negative-sequence reactive power sharing, caused bythe impedance mismatching of distribution lines and distributedgenerators, has not been solved only by Q^(−)-G droop control.In this paper, a distributed cooperative secondary unbalancedvoltage control strategy is proposed to decrease the outputvoltage unbalance factor (VUF) of each droop-controlled DG,as well as to further enhance the negative-sequence reactivepower sharing effectiveness among DGs by properly shiftingup and down the Q^(−)-G droop characteristics of each DG.An algorithm for adaptive VUF weight coefficient is proposedto better suppress VUF under severe imbalance conditions.Furthermore, a negative-sequence small-signal model of an MGunder an unbalanced condition, considering the communicationdelay time of the proposed SUVC, is established to analyze thesystem’s stability and transient performance under the influenceof some critical parameters. Finally, the effectiveness of theproposed strategy is validated by the simulation results froma real-time emulator of StarSim HIL. 展开更多
关键词 Distributed cooperative control MG negativesequence reactive power starsim real-time platform time delay voltage unbalance compensation
原文传递
A Sliding Mode Approach to Enhance the Power Quality of Wind Turbines Under Unbalanced Voltage Conditions 被引量:2
16
作者 Mohammad Javad Morshed Afef Fekih 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第2期566-574,共9页
An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, an... An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, and high quality transient characteristics of the integral terminal sliding mode control with the estimation properties of disturbance observers. The controller gains were auto-tuned using a fuzzy logic approach.The effectiveness of the proposed design was assessed under deep voltage sag conditions and parameter variations. Its dynamic response was also compared to that of a standard SMC approach.The performance analysis and simulation results confirmed the ability of the proposed approach to maintain the active power,currents, DC-link voltage and electromagnetic torque within their acceptable ranges even under the most severe unbalanced voltage conditions. It was also shown to be robust to uncertainties and parameter variations, while effectively mitigating chattering in comparison with the standard SMC. 展开更多
关键词 Doubly fed induction generators(DFIG) fuzzy approach integral terminal sliding mode control(ITSMC) OBSERVER power quality voltage unbalances wind turbines
下载PDF
The Research of Three-phase Boost/Buck-boost DC-AC Inverter
17
作者 Xiangli Li Zhaoyang Yan +1 位作者 Yanni Gao Hanhong Qi 《Energy and Power Engineering》 2013年第4期906-913,共8页
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ... This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application. 展开更多
关键词 three-phase BOOST SINGLE-STAGE INVERTER three-phase BUCK-BOOST SINGLE-STAGE INVERTER Double-loop controlLER Sliding Mode controlLER
下载PDF
Optimization of Rotor Assembly Process of Rotor Initial Unbalance of an Aeroengine Gas Generator
18
作者 BAO Youlin LI Lixin +2 位作者 CAO Peng LI Ciying HUANG Xinglong 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2021年第1期132-139,共8页
The rotor initial unbalance of an aeroengine gas generator of turboshaft engine seriously affects rotor assembly process.To reasonably optimize rotor assembly process,the effect analyses of rotor initial unbalance of ... The rotor initial unbalance of an aeroengine gas generator of turboshaft engine seriously affects rotor assembly process.To reasonably optimize rotor assembly process,the effect analyses of rotor initial unbalance of single disc and combined discs on rotor dynamic characteristics are firstly implemented in respect of the dispersity of rotor initial unbalance.It is found that the most important factors contributing to rotor vibration are the unbalances of the first stage compressor disc and the second stage turbine disc.However,reducing the mass of two discs conflicts with the control of the whole gas generator rotor balance resulting from the unbalance increase of single components.Thus,we further analyze the key control factors of affecting rotor initial unbalance,and give the strict control measures of centrifugal impeller runout in the assembly process by adjusting the angle of central tie rod axis.The purpose of this measures to make the assembly process simpler and more effective for timely controlling rotor initial unbalance.The efforts of this study validate that the proposed method is workable for the rotor tightened by a central tie rod and possesses the significant meaning of practical application in engineering. 展开更多
关键词 turboshaft engine initial unbalance assembly process gas generator rotor control technique
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
19
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Relevant Factors to a Statistical Analysis of Overvoltages - Application to Three-Phase Reclosing of Compensated Transmission Lines
20
作者 P. Mestas M.C. Tavares 《Energy and Power Engineering》 2013年第4期1165-1171,共7页
This paper describes the statistical study of important factors that influences transient over voltages resulting from three-phase reclosing of shunt compensated transmission lines. These factors include the model use... This paper describes the statistical study of important factors that influences transient over voltages resulting from three-phase reclosing of shunt compensated transmission lines. These factors include the model used for transmission line representation and the influence of line transposition. Additionally, the over voltages reduction to proper levels depending on the type of control technique are illustrated and analyzed in statistical terms. The evaluation covers three shunt compensation degrees. The digital simulations were performed using the PSCAD/EMTDC software. 展开更多
关键词 Transient OVERVOLTAGES three-phase RECLOSING controlled Switching SURGE ARRESTERS Pre-insertion Re-sistor
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部