期刊文献+
共找到131篇文章
< 1 2 7 >
每页显示 20 50 100
Three-Phase Unbalance Prediction of Electric Power Based on Hierarchical Temporal Memory 被引量:1
1
作者 Hui Li Cailin Shi +2 位作者 Xin Liu Aziguli Wulamu Alan Yang 《Computers, Materials & Continua》 SCIE EI 2020年第8期987-1004,共18页
The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the... The difference in electricity and power usage time leads to an unbalanced current among the three phases in the power grid.The three-phase unbalanced is closely related to power planning and load distribution.When the unbalance occurs,the safe operation of the electrical equipment will be seriously jeopardized.This paper proposes a Hierarchical Temporal Memory(HTM)-based three-phase unbalance prediction model consisted by the encoder for binary coding,the spatial pooler for frequency pattern learning,the temporal pooler for pattern sequence learning,and the sparse distributed representations classifier for unbalance prediction.Following the feasibility of spatial-temporal streaming data analysis,we adopted this brain-liked neural network to a real-time prediction for power load.We applied the model in five cities(Tangshan,Langfang,Qinhuangdao,Chengde,Zhangjiakou)of north China.We experimented with the proposed model and Long Short-term Memory(LSTM)model and analyzed the predict results and real currents.The results show that the predictions conform to the reality;compared to LSTM,the HTM-based prediction model shows enhanced accuracy and stability.The prediction model could serve for the overload warning and the load planning to provide high-quality power grid operation. 展开更多
关键词 three-phase unbalance power load prediction model hierarchical temporal memory
下载PDF
Research of Three-Phase Unbalanced Treatment in Low-Voltage Distribution Network Based on New Commutation Switch 被引量:1
2
作者 Xue Liu Jun Jia Jian Wang 《World Journal of Engineering and Technology》 2019年第4期10-17,共8页
Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance i... Low-voltage distribution systems in our country are mostly used in agricultural loads and household loads. The value and using time of these kinds of loads are uncontrollable, which lead to the three-phase imbalance in low-voltage distribution system, and seriously affect the quality of power supply. A new type of the commutation system and an improved quantum genetic algorithm (IQGA) are proposed in the paper. At last, the rationality and the efficiency of the method are verified by a practical example. 展开更多
关键词 LOW-VOLTAGE DISTRIBUTION Network three-phase unbalance COMMUTATION SWITCH IQGA
下载PDF
Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network
3
作者 Ghullam Mustafa Bhutto Birgitte Bak-Jensen +1 位作者 Pukar Mahat Carlo Cecati 《Energy and Power Engineering》 2013年第9期551-559,共9页
Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc.... Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and networks like this. The voltage unbalances, for the tested cases in the CIGRE LV test network are mainly due to single phase loads and due to unbalanced faults. The compensation of unbalanced voltage sags and voltage unbalance in the CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0. 展开更多
关键词 Power Quality unbalanced VOLTAGE Sags MITIGATION of VOLTAGE unbalance VOLTAGE unbalance factor (VUF) Distributed Static COMPENSATOR (STATCOM)
下载PDF
Three-Phase Optimal Power Flow for Study of PV Plant Distributed Impact on Distribution Systems
4
作者 Malinwo E. Ayikpa Katia C. de Almeida Guilherme C. Danielski 《Journal of Electrical Engineering》 2017年第1期47-56,共10页
This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or abs... This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation. 展开更多
关键词 three-phase optimal power flow photovoltaic generation unbalance voltage LOSS primal-dual interior point method.
下载PDF
Optimal Planning of Hybrid AC/DC Low-voltage Distribution Networks Considering DC Conversion of Three-phase Four-wire Low-voltage AC Systems
5
作者 Bo Zhang Lu Zhang +2 位作者 Wei Tang Gen Li Chen Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期141-153,共13页
The increasing integration of distributed household photovoltaics(PVs)and electric vehicles(EVs)may further ag gravate voltage violations and unbalance of low-voltage distribu tion networks(LVDNs).DC distribution netw... The increasing integration of distributed household photovoltaics(PVs)and electric vehicles(EVs)may further ag gravate voltage violations and unbalance of low-voltage distribu tion networks(LVDNs).DC distribution networks can increase the accommodation of PVs and EVs and mitigate mutilple pow er quality problems by the flexible power regulation capability of voltage source converters.This paper proposes schemes to es tablish hybrid AC/DC LVDNs considering the conversion of the existing three-phase four-wire low-voltage AC systems to DC op eration.The characteristics and DC conversion constraints of typical LVDNs are analyzed.In addition,converter configura tions for typical LVDNs are proposed based on the three-phase four-wire characteristics and quantitative analysis of various DC configurations.Moreover,an optimal planning method of hybrid AC/DC LVDNs is proposed,which is modeled as a bi-level programming model considering the annual investments and three-phase unbalance.Simulations are conducted to verify the effectiveness of the proposed optimal planning method.Sim ulation results show that the proposed optimal planning method can increase the integration of PVs while simultaneously reduc ing issues related to voltage violation and unbalance. 展开更多
关键词 Optimal planning low-voltage distribution net work three-phase unbalance DC conversion
原文传递
工厂分布式光伏电能质量综合治理分析 被引量:1
6
作者 黎光泽 《上海节能》 2024年第6期1029-1035,共7页
装备制造业工厂用电负荷较高,建设屋面分布式光伏项目能产生较好的经济效益和社会效益,但工厂电力供应系统由于增加了光伏发电设备,导致用电系统电能质量下降,表现为功率因数过低、产生力调电费等,故工厂迫切希望对此类用电系统进行电... 装备制造业工厂用电负荷较高,建设屋面分布式光伏项目能产生较好的经济效益和社会效益,但工厂电力供应系统由于增加了光伏发电设备,导致用电系统电能质量下降,表现为功率因数过低、产生力调电费等,故工厂迫切希望对此类用电系统进行电能质量治理,以解决电费罚款问题。 展开更多
关键词 电能质量 功率因数 无功补偿 谐波电流 三相不平衡
下载PDF
Control strategy for microgrid under three-phase unbalance condition 被引量:10
7
作者 Hongtao SHI Fang ZHUO +1 位作者 Hao YI Zhiqing GENG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期94-102,共9页
Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control pe... Microgrid(MG) is generally developed at utility terminal which contains lots of unbalanced loads and distributed generations(DGs). The interaction between MG and the unbalance loads or DGs will degrades the control performance of interfaced inverter in MG and dramatically leads to MG voltage unbalance. In this paper, a negative-sequence compensation based three-phase voltage unified correction strategy is proposed. While MG operates in islanded mode, a positive virtual impedance control is used to eliminate the negative voltage resulted from the negative-sequence current,and then a positive-sequence voltage control loop and negative-sequence control loop are used to improve the inverter control performance. While MG operates in grid-tied mode,the inverter operates as a negative-sequence current source to compensate the negative-sequence currents of loads to guarantee the point of common coupling(PCC) voltage balance.By using the proposed strategy, the voltage control performance of inverter can be improved;the MG power quality can be enhanced significantly. Simulation and experimental results verify the effectiveness of the proposed method. 展开更多
关键词 MICROGRID INVERTER three-phase unbalance Negative compensation
原文传递
Power Factor Correction Rectifier with a Variable Frequency Voltage Source in Vehicular Application 被引量:1
8
作者 Amine Toumi Mohamed Radhouan Hachicha +1 位作者 Moez Ghariani Rafik Neji 《Intelligent Control and Automation》 2014年第1期1-11,共11页
This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in t... This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading effect on the alternator introduces harmonic currents and increases the alternator apparent power requirements. To overcome these problems and aiming more stability and better design of the alternator, a new third harmonic injection technique is proposed. This technique allows to preserve a good THD (Total Harmonic Distortion) of the input source at any frequency and to decrease losses in semiconductors switches, thereby allowing more stability and reducing the apparent power requirements. A comparative study between the standard and the new technique is made and highlights the effectiveness of the new design. A detailed analysis of the proposed topology is presented and simulations as well as experimental results are shown. 展开更多
关键词 ASYNCHRONOUS Machine Control-Oriented Vector of Rotor Flux PWM BOOST Converter HARMONIC Injection Power factor Correction three-phase RECTIFIER JUNCTION Temperature
下载PDF
Investigation of Power Factor Behavior in AC Railway System Based on Special Traction Transformers
9
作者 Mohsen Kalantari Mohammad Javad Sadeghi +1 位作者 Seyed Saeed Fazel Siamak Farshad 《Journal of Electromagnetic Analysis and Applications》 2010年第11期618-626,共9页
The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unba... The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unbalance loading are investigated simultaneously for electrical railway systems. Special traction transformers (i.e. single-phase, V/V, Wye-Delta, Scott, and Le Blanc) are used between the utility grid and the traction load. For analysis, different defini-tions of power factors are considered, which are presented by IEEE Std.1459. The detailed simulation study is made with MATLAB/SIMULINK program to represent the impacts of harmonic components and unbalance loading on the power factor behavior in the Electrical Railway systems. 展开更多
关键词 Power factor TRACTION TRANSFORMER unbalance LOADING
下载PDF
带中点平衡的VIENNA整流器改进SVPWM策略
10
作者 王党树 杨亚强 +3 位作者 仪家安 邓翾 董振 王新霞 《广西师范大学学报(自然科学版)》 CAS 北大核心 2023年第1期67-75,共9页
VIENNA整流器的中点电压不平衡问题使得两均压电容及主开关器件承受的电压应力不均衡,导致交流侧输入电流波形畸变,较大降低系统可靠性。对于此问题,本文研究传统三电平空间矢量调制对VIENNA整流器中点电压的作用原理,在此基础上提出一... VIENNA整流器的中点电压不平衡问题使得两均压电容及主开关器件承受的电压应力不均衡,导致交流侧输入电流波形畸变,较大降低系统可靠性。对于此问题,本文研究传统三电平空间矢量调制对VIENNA整流器中点电压的作用原理,在此基础上提出一种改进SVPWM控制策略来抑制中点电位的波动:将传统扇区与输入侧三相电流极性结合,对传统扇区进一步划分,通过新扇区的判断和正负小矢量的调节因子抵消中矢量作用,从而达到中点平衡。最后通过仿真验证所提控制策略与传统SVPWM相比,中点电位和电流的波动由±5 V和±18 A减小为±2.5 V和±7.5V,有效抑制了中点电压不平衡的问题。 展开更多
关键词 改进SVPWM控制策略 中点电压不平衡 调节因子 VIENNA整流器 正负小矢量
下载PDF
三相非正弦配电网的多重矢量功率理论及无功电流补偿策略
11
作者 孙佳安 李琳 《中国电力》 CSCD 北大核心 2023年第3期109-117,共9页
随着配电网源网荷储的复杂性提升使电压不平衡和畸变更加严重,现有三相功率理论不能满足平衡条件并导致无功补偿效果不佳。为此,提出了三相非正弦配电网的多重矢量功率理论和无功补偿策略。利用对电压和电流的频域分解结果建立基向量并... 随着配电网源网荷储的复杂性提升使电压不平衡和畸变更加严重,现有三相功率理论不能满足平衡条件并导致无功补偿效果不佳。为此,提出了三相非正弦配电网的多重矢量功率理论和无功补偿策略。利用对电压和电流的频域分解结果建立基向量并形成电压和电流矢量,并定义两矢量的几何积为多重矢量功率,并证明该理论满足功率平衡。根据多重矢量功率理论提出了以单位基波功率因数和理想谐波消除为补偿目标的2种改进补偿策略。在不同非理想电压工况下对比了不同功率理论下的7种无功分量检测算法,并选择结果较好的5种算法进行无功补偿仿真分析和实验验证。结果表明,改进单位基波功率因数法可实现流入系统的视在功率最低,从而实现传输损耗最低;改进完美谐波消除法对无功、谐波和不平衡分量的综合补偿效果最好。 展开更多
关键词 多重矢量功率 三相不平衡和谐波 无功补偿 单位功率因数法 完美谐波消除法
下载PDF
电网的无功及三相不平衡综合补偿研究 被引量:46
12
作者 李心广 赖声礼 +1 位作者 秦华标 徐向民 《电网技术》 EI CSCD 北大核心 2001年第10期30-33,共4页
电力系统无功功率补偿不足会引起功率因数下降,而三相功率不平衡则会影响到用电设备的 安全。此问题在不十分严重的情况下未引起人们足够的重视。基于无功补偿的原理 ,作者提出了一种新的综合补偿方法,在用它补偿无功功率的同时,... 电力系统无功功率补偿不足会引起功率因数下降,而三相功率不平衡则会影响到用电设备的 安全。此问题在不十分严重的情况下未引起人们足够的重视。基于无功补偿的原理 ,作者提出了一种新的综合补偿方法,在用它补偿无功功率的同时,三相不平衡也得到了改善。仿真结果和实际运行表明,此方法是有效的。此外,还介绍了一种对补偿电容器的人工神经网络控制方法。 展开更多
关键词 电网 无功功率补偿 感性负载 三相不平衡综合补偿
下载PDF
500kV主变单相置换可行性研究 被引量:6
13
作者 夏成军 黄冬燕 +1 位作者 代文良 邱桂华 《电力系统保护与控制》 EI CSCD 北大核心 2011年第17期93-97,102,共6页
结合某500kV变电站#2主变替换可行性研究的工程实例,从理论分析和基于PSCAD/EMTDC仿真计算两个方面研究用原#1主变A相变压器临时替代存在故障的#2主变B相后,正常方式及变压器重载方式下因三相绕组短路电压百分比不一致引起的相间环流、... 结合某500kV变电站#2主变替换可行性研究的工程实例,从理论分析和基于PSCAD/EMTDC仿真计算两个方面研究用原#1主变A相变压器临时替代存在故障的#2主变B相后,正常方式及变压器重载方式下因三相绕组短路电压百分比不一致引起的相间环流、电压电流不平衡情况及谐波电流问题,并进行替换前后的对比。初步认为可以使用#1主变A相临时替换#2主变B相运行,同时也说明变压器运行时其三相绕组的短路电压百分比允许一定程度的不对称性,为进一步研究三相变压器单相置换的适用性及可行性提供了新的思路和想法。 展开更多
关键词 500 kV主变 电压不平衡度 电流不平衡度 谐波电流
下载PDF
多回并联电缆线路参数的不对称性分析 被引量:30
14
作者 邓星 蒙绍新 +4 位作者 尹项根 张哲 赵健康 王育学 孔祥平 《高电压技术》 EI CAS CSCD 北大核心 2010年第12期3119-3124,共6页
输电线路参数的不对称性对电网的安全运行有着重要影响。为分析并联电缆线路参数的不对称性,首先以卡松线路模型为基础,建立电缆序阻抗参数的计算模型,将高压单芯电缆的金属护套视作普通线路,与大地构成"护套-大地"回路,进而... 输电线路参数的不对称性对电网的安全运行有着重要影响。为分析并联电缆线路参数的不对称性,首先以卡松线路模型为基础,建立电缆序阻抗参数的计算模型,将高压单芯电缆的金属护套视作普通线路,与大地构成"护套-大地"回路,进而推广到多回并联运行的电缆线路,并阐述了多回电缆序阻抗参数的计算方法;然后通过引入线路参数不平衡度的概念,重点对比分析了几种典型相序排列方式下并联双回电缆线路序阻抗参数的不对称性。分析结果表明:双回并联电缆导线"品"字型排列的对称性优于垂直排列和水平排列,其中又以"品"字型垂直排列的对称性最佳。 展开更多
关键词 并联电缆 参数计算 金属护套 不平衡度 不对称 相序排列
下载PDF
1000kV同塔双回线路不平衡度及换位方式分析 被引量:51
15
作者 王晓彤 林集明 +2 位作者 班连庚 项祖涛 韩彬 《电网技术》 EI CSCD 北大核心 2009年第5期1-5,16,共6页
对1000kV淮南-皖南同塔双回线路参数、母线电压和发电机电流的不平衡度进行了分析,研究中考虑了2种常用的换位方式,对不同换位方式下的潜供电流和恢复电压、感应电压和感应电流进行了比较。结果表明,从降低母线电压和发电机电流不平衡... 对1000kV淮南-皖南同塔双回线路参数、母线电压和发电机电流的不平衡度进行了分析,研究中考虑了2种常用的换位方式,对不同换位方式下的潜供电流和恢复电压、感应电压和感应电流进行了比较。结果表明,从降低母线电压和发电机电流不平衡度的角度来看,采用换位方式2较好;从减少潜供电流和感应电压的角度来看,采用换位方式1更佳。在满足国标要求的前提下,为了限制线路的潜供电流、感应电压和感应电流,推荐淮皖线采用换位方式1。 展开更多
关键词 同塔双回线路 不平衡度 换位方式 潜供电流 感应电压
下载PDF
500kV电缆线路工频参数的计算与分析 被引量:22
16
作者 王晓彤 项祖涛 +3 位作者 班连庚 蒋卫平 钱康 牛涛 《电网技术》 EI CSCD 北大核心 2013年第8期2310-2315,共6页
采用电磁暂态仿真程序(EMTP),以一条8.7 km的500 kV交联聚乙稀(XLPE)电缆为例,对电缆线路的工频相参数、序参数进行计算及分析。研究表明,不同布置方式对电缆的电容矩阵没有影响,且零序电容和正序电容相等;若电缆线路不换位、将金属护... 采用电磁暂态仿真程序(EMTP),以一条8.7 km的500 kV交联聚乙稀(XLPE)电缆为例,对电缆线路的工频相参数、序参数进行计算及分析。研究表明,不同布置方式对电缆的电容矩阵没有影响,且零序电容和正序电容相等;若电缆线路不换位、将金属护套交叉互联后,会增加电缆线路的电磁不平衡度;而在电缆线路换位、金属护套也交叉互联的条件下,其电磁不平衡度则很低,可认为是平衡线路。在护套两端接地的条件下,将金属护套进行交叉互联,会使得电缆线路的正序阻抗增加,而对零序阻抗没有影响;电缆线路两端的接地电阻对零序阻抗影响显著,中间单元的接地电阻则影响较小。 展开更多
关键词 500kV 电缆线路 工频 相参数 序参数 不平衡度
下载PDF
矩阵变换器的输入电流控制策略 被引量:6
17
作者 佘宏武 林桦 +1 位作者 王兴伟 乐利民 《电力自动化设备》 EI CSCD 北大核心 2010年第6期45-49,54,共6页
根据有功功率平衡原理推导出不平衡输入电压下表征矩阵变换器输入电流特性的通用方程,分析表明矩阵变换器的输入电流特性只能通过对输出功率及输入电流偏置角的控制来调节。根据矩阵变换器输入电流特性方程及输入电流控制目标得到3种典... 根据有功功率平衡原理推导出不平衡输入电压下表征矩阵变换器输入电流特性的通用方程,分析表明矩阵变换器的输入电流特性只能通过对输出功率及输入电流偏置角的控制来调节。根据矩阵变换器输入电流特性方程及输入电流控制目标得到3种典型输入电流控制策略。在输出电压平衡正弦的情况下:使矩阵变换器的输入电流矢量与输入电压矢量保持固定的功率因数角(策略1),可得到不平衡且非正弦的输入电流;使输入电流矢量跟踪输入电压正序分量与负序分量之差的方向(策略2),可得到不平衡但正弦的输入电流;输出电压矢量幅值变化并使输入电流矢量与输入电压正序分量保持固定的功率因数角(策略3),可得到平衡正弦的输入电流,但输出电压不平衡且非正弦。其中,策略1的输入功率因数及输出电压控制能力最强,但输入电流波形质量最差;策略2的输入电流波形质量较好,但输入功率因数和输出电压控制能力有限;策略3得到的输入电流波形质量最好,但输出电压特性最差。通过仿真及实验验证了理论分析的正确性。 展开更多
关键词 矩阵变换器 输入电流 不平衡 谐波 功率因数
下载PDF
基于有限元的呼吸裂纹转子动力学特性 被引量:11
18
作者 刘长利 谢朋儒 +2 位作者 周邵萍 李诚 郑建荣 《振动.测试与诊断》 EI CSCD 北大核心 2011年第2期185-189,265,共5页
采用有限单元法建立了含裂纹Jeffcott转子的有限元模型,利用应变能释放率方法得到了裂纹单元的刚度矩阵,采用应力强度因子为零法模拟了裂纹的呼吸效应。计算分析了在一个稳态旋转周期内裂纹开闭的规律,以及直斜裂纹转子振动响应的特点... 采用有限单元法建立了含裂纹Jeffcott转子的有限元模型,利用应变能释放率方法得到了裂纹单元的刚度矩阵,采用应力强度因子为零法模拟了裂纹的呼吸效应。计算分析了在一个稳态旋转周期内裂纹开闭的规律,以及直斜裂纹转子振动响应的特点。计算结果表明,斜裂纹开始张开以及闭合的时间迟后于直裂纹,斜裂纹处于全闭与全开状态所经历的时间比直裂纹长。直斜裂纹转轴的1X和2X倍频响应随着裂纹深度的增加而增加,但3X倍频分量变化不大。 展开更多
关键词 转子 直裂纹 斜裂纹 应力强度因子为零法 不平衡响应
下载PDF
基于负荷功率的三相不平衡度的计算方法 被引量:55
19
作者 同向前 王海燕 尹军 《电力系统及其自动化学报》 CSCD 北大核心 2011年第2期24-30,共7页
三相不平衡度的估算是贯彻国家标准、提高电能质量的基础,故提出一种三相三线配电系统中由不对称负荷引起的三相不平衡度的实用计算方法。在引入了三相不对称负荷的序容量的概念之后,负荷电流不平衡度等于负荷负序容量与正序容量之比,... 三相不平衡度的估算是贯彻国家标准、提高电能质量的基础,故提出一种三相三线配电系统中由不对称负荷引起的三相不平衡度的实用计算方法。在引入了三相不对称负荷的序容量的概念之后,负荷电流不平衡度等于负荷负序容量与正序容量之比,由该不对称负荷在某公共连接点引起的三相电压不平衡度等于负荷负序容量与系统短路容量之比;建立了三相不对称负荷的序容量与负荷相间功率之间的函数关系,简化了三相不平衡度的计算过程。算例表明该方法简便易用。该方法适合于工业配电网在设计规划阶段对三相不平衡度的估算。 展开更多
关键词 三相负荷序容量 三相不平衡度 不对称负荷 电能质量
下载PDF
电压不平衡度的加窗FFT快速测量方法 被引量:14
20
作者 温和 金冉 +1 位作者 蒙娟 黎福海 《电工技术学报》 EI CSCD 北大核心 2017年第16期275-283,共9页
电压不平衡度是电能质量的重要参数之一,其准确测量一方面依赖于三相电压基波相量(幅值和相位)的精确估计,另一方面需要快速求取相序分量。但是,频谱泄漏和栅栏效应会严重影响电压幅值和相位的估计精度,而相序分量计算过程中的开方运算... 电压不平衡度是电能质量的重要参数之一,其准确测量一方面依赖于三相电压基波相量(幅值和相位)的精确估计,另一方面需要快速求取相序分量。但是,频谱泄漏和栅栏效应会严重影响电压幅值和相位的估计精度,而相序分量计算过程中的开方运算又降低了不平衡度测量的实时性。提出电压不平衡度加窗快速傅里叶变换(FFT)测量方法。首先采用加窗FFT实现三相电压相量的准确计算,然后根据几何原理将方均根计算简化为多项式计算,从而实现相序分量及电压不平衡度的快速测量。仿真结果表明,所提方法可以达到与GB/T 15543—2008推荐方法相同的精度等级。实际测量实验进一步验证了所提算法的有效性及可行性。 展开更多
关键词 电压不平衡度 电压相量 相序分量 加窗快速傅里叶变换 多项式
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部