The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized li...The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.展开更多
BACKGROUND Intraoperative and postoperative biliary injuries remain significant complications of laparoscopic common bile duct exploration(LCBDE).Indocyanine green(ICG)has been shown to significantly reduce injuries c...BACKGROUND Intraoperative and postoperative biliary injuries remain significant complications of laparoscopic common bile duct exploration(LCBDE).Indocyanine green(ICG)has been shown to significantly reduce injuries caused by intraoperative operational errors.We found that the J-tube can reduce postoperative strictures and injuries to the common bile duct.At this moment,we aim to analyze and compare the complications,efficacy,short-term outcomes,and feasibility of these two adjunctive tools for LCBDE.AIM To evaluate the efficacy of ICG fluorescence imaging In LCBDE and J-tube drainage for patients with common bile duct stones.METHODS We retrospectively collected the clinical case data of patients who were treated at the Hepatobiliary Surgery Department of the Third People’s Hospital of Nantong,affiliated with Nantong University,from January 2016 to January 2021 due to gallbladder stones with choledocholithiasis and who underwent LCBDE combined with a primary suture and either J-tube or T-tube drainage.The patients were divided into groups:Traditional white-light laparoscopy+T-tube group(WL+T-tube),traditional WL+J-tube group,fluorescent laparoscopy+T-tube group(ICG+T-tube)and fluorescent laparoscopy+J-tube group(ICG+J-tube).The preoperative and postoperative clinical case data,laboratory examination data,and intraoperative and postoperative complications(including postoperative bile leakage,electrolyte disturbances,biliary peritonitis,and postoperative infections)and other relevant indicators were compared.RESULTS A total of 198 patients(112 males and 86 females)were included in the study,with 74 patients in the WL+T-tube,47 in the WL+J-tube,42 in the ICG+T-tube,and 35 in the ICG+J-tube.Compared with the other groups,the ICG+J had significantly shorter operation time(114 minutes,P=0.001),less blood loss(42 mL,P=0.02),shorter postoperative hospital stays(7 days,P=0.038),and lower surgical costs(China yuan 30178,P=0.001).Furthermore,patients were subdivided into two groups based on whether a T-tube or J-tube was placed during the surgery.By the third postoperative day,the aspartate transaminase,glutamic pyruvic transaminase,total bilirubin,and direct bilirubin levels were lower in the J-tube group than in the T-tube group(P<0.001).At last,follow-up observations showed that the incidence of biliary strictures at three months postoperatively was significantly lower in the J-tube group than in the T-tube group(P=0.002).CONCLUSION ICG fluorescence imaging in laparoscopic cholecystectomy with common bile duct exploration and J-tube drainage facilitates rapid identification of biliary anatomy and variations,reducing intraoperative bile duct injury,blood loss,surgery duration,and postoperative bile duct stenosis rates,supporting its clinical adoption.展开更多
It is of great significance to study the brain structure and function in deep-tissue for neuroscience research and bio-medical applications because of the urgent demand for precise theranostics.Three-photon fluorescen...It is of great significance to study the brain structure and function in deep-tissue for neuroscience research and bio-medical applications because of the urgent demand for precise theranostics.Three-photon fluorescence microscopic(3PFM)bioimaging excited by the light in near-infrared IIb(NIR-IIb,1,500–1,700 nm)spectral region is one of the most promising imaging techniques with the advantages of high spatial resolution,large imaging depth,and reduced scattering.Herein,a type of NIR-IIb light excitable deep-red emissive semiconducting polymer dots(P-dots)with bright 3PF and large three-photon absorption cross-section(σ3)at 1,550 nm was prepared.Then the P-dots were functionalized with polystyrene polymer polystyrene graft ethylene oxide functionalized with carboxyl groups(PS-PEG-COOH)and modified with NH2-poly(ethylene glycol)(PEG)to synthesis photochemically stable and biocompatible P-dots nanoparticles(NPs).Further the P-dots NPs were utilized for in vivo 3PFM bioimaging of cerebral vasculature with and without the brain skull under 1,550 nm femtosecond(fs)laser excitation.In vivo 3PFM bioimaging of the mice cerebral vasculature at various vertical depths was obtained.Moreover,a vivid three-dimensional structure of the mice vascular architecture beneath the skull was reconstructed.At the depth of 350μm beneath the brain skull,3.8μm blood vessels could still be clearly recognized.NIR-IIb excitable P-dots assisted 3PFM bioimaging has great potential in accurate deep tissue bioimaging.展开更多
Aggregation-induced emission (AIE) luminogen displays bright fluorescence and has photobleaching resistance in its aggregation state. It is an ideal fluorescent contrast agent for bioimaging. Multiphoton microscopy ...Aggregation-induced emission (AIE) luminogen displays bright fluorescence and has photobleaching resistance in its aggregation state. It is an ideal fluorescent contrast agent for bioimaging. Multiphoton microscopy is an important tool for bioimaging since it possesses the ability to penetrate deep into biological tissues. Herein, we used AIE luminogen together with multiphoton microscopy for long-term imaging of zebrafish. A typical AIE luminogen, 2,3-bis(4-(phenyl(4- (1,Z2-triphenylvinyl) phenyl)amino)phenyl) fumaronitrile (TPE-TPA-FN or TTF), was encapsulated with 1,2-distearoyl-sn-glycero-3-phosphoethanola-mine-N- [methoxy(polyethylene glycol)-2000] (DSPE-mPEG2000) to form nanodots that exhibited bright three-photon fluorescence under 1,560 nm-femtosecond (fs) laser excitation. The TTF-nanodots were chemically stable in a wide range of pH values and showed no in vivo toxicity in zebrafish according to a series of biological tests. The TTF-nanodots were microinjected into zebrafish embryos, and the different growth stages of the labeled embryos were monitored with a three-photon fluorescence microscope. TTF-nanodots could be traced inside the zebrafish body for as long as 120 hours. In addition, the TTF-nanodots were utilized to target the blood vessel of zebrafish, and three-photon fluorescence angiogram was performed. More importantly, these nanodots were highly resistant to photobleaching under 1,560 nm-fs excitation, allowing long-term imaging of zebrafish.展开更多
White matter,a densely packed collection of myelinated axons,plays an essential part in neural networks.With high spatial resolution and deep penetration,multi-photon microscopy(MPM)is promising for white matter imagi...White matter,a densely packed collection of myelinated axons,plays an essential part in neural networks.With high spatial resolution and deep penetration,multi-photon microscopy(MPM)is promising for white matter imaging in animal models in vivo.The third harmonic generation(THG)signal can be generated from white matter,but the bottom part of the white matter layer generates weak THG due to its high scattering.Here,we demonstrate an in vivo labeling and imaging technology,capable of visualizing the white matter layer in the mouse brain,combining°uorescence labeling with MitoTracker Red and three-photon°uorescence(3PF)microscopy excited at the 1700 nm window.3PF signals are several times higher than THG signals,resulting in deeper imaging of the white matter layer with the former.Our results indicate that 3PF microscopy is a promising technology for white matter imaging in the deep brain in vivo.展开更多
In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpat...In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.展开更多
Chymosin is one of the critical enzymes in cheese making.Herein,we proposed a novel fluorometric assay for chymosin determination.Firstly,covalent organic frameworks(COF)were synthesized and exfoliated to 2-dimensiona...Chymosin is one of the critical enzymes in cheese making.Herein,we proposed a novel fluorometric assay for chymosin determination.Firstly,covalent organic frameworks(COF)were synthesized and exfoliated to 2-dimensional COF nanosheets(COF NS)by ultrasound treatment.Gold nanoparticles(Au NPs)were loaded with COF NS to prepare AuNPs/COF NS(Au@COF NS).Secondly,rhodamine B(RhB)modified substrate peptide(Pep)for chymosin was linked with Au@COF NS to construct a Pep-Au@COF NS nanocomposite.For the sensing principle,fluorescence of RhB was quenched by Au@COF NS and the fluorescence intensity was weak due to the fluorescence resonance energy transfer between COF NS and RhB of Pep.However,in the presence of chymosin,the RhB was released by specific cleavage of the substrate peptide by chymosin and resulted in the recovery of fluorescence.The increased fluorescence intensity was proportional to the increase of chymosin concentration and thus a“turn on”fluorescent sensor for chymosin was constructed.The sensor showed a linear range in the concentration of 0.05-60.00μg/mL for the detection of chymosin with a detection limit of 20 ng/mL.The sensor was used to quantify chymosin in rennet product with good selectivity,which has the potential applications in cheese manufacturing.展开更多
BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperat...BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperative identification of the biliary system and reduces the risk of bile duct injury.However,the usual single color fluorescence imaging(SCFI)has limitations in manifesting the fluorescence signal of the target structure when its intensity is relatively low.Moreover,sur-geons often experience visual fatigue.We hypothesized that a novel imaging stra-tegy,named multi-color fluorescence imaging(MCFI),could potentially address these issues by decreasing hepatic and background fluorescence pollution and improving biliary visualization.AIM To investigate the novel imaging strategy MCFI in LC.METHODS This was a single-center retrospective study conducted at Peking Union Medical College Hospital,Beijing,China.Patients who underwent LC from June 2022 to March 2023 by the same surgical team were enrolled.Demographic features,clinical and surgical information were collected.The clarity,visual comfort,and effectiveness of different imaging strategies were subjectively evaluated by surgeons.RESULTS A total of 155 patients were included,60 patients were in the non-ICG group in which only bright light illuminance without ICG was applied,60 patients were in the SCFI group,and 35 patients were in the MCFI group.No statist-ically significant differences were found in demographics or clinical history.Post-surgical complications were minimal in all 3 groups with no significant differences observed.MCFI improved the clarity of imaging and visual comfort.Clarity of imaging and visual comfort were improved with MCFI.CONCLUSION MCFI improves biliary visualization and reduces liver fluorescence contamination,which supports its routine use in LC.MCFI may also be a better choice than SCFI in other clinical settings.展开更多
A near infrared to visible blue, green, and red upconversion luminescence in a Tb^3+-doped CaO-Al2O3-SiO2 glass was studied, which was excited using 800 nm femtosecond laser irradiation. The upconversion luminescence...A near infrared to visible blue, green, and red upconversion luminescence in a Tb^3+-doped CaO-Al2O3-SiO2 glass was studied, which was excited using 800 nm femtosecond laser irradiation. The upconversion luminescence was attributed to ^5D3→^7F5, ^5D3→^7F4, ^5D3→^7F3, ^5D4→^7F6, ^5D4→^7F5, ^5D4→^7F4, and ^5D4→^7F3 transitions of Tb^3+. The relationship between upconversion luminescence intensity and the pump power indicated that a three-photon simultaneous absorption process was dominant in this upconversion luminescence. The intense red, green, and blue upconversion luminescence of Tb^3+-doped CaO-Al2O3-SiO2 glass may be potentially useful in developing three-dimensional display applications.展开更多
Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imagi...Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation.展开更多
Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvol...Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvolution becomes invalid in the presence of noise as it leads to infinite amplification of high-frequency noise components.To address this issue,we propose a deconvolution algorithm based on the maximum entropy principle.We validate the effectiveness of the proposed algorithm by utilizing simulated LIF spectra at various noise levels(signal-to-noise ratio,SNR=20–80 d B)and measured LIF spectra with Xe as the working fluid.In the typical measured spectrum(SNR=26.23 d B)experiment,compared with the Gaussian filter and the Richardson–Lucy(R-L)algorithm,the proposed algorithm demonstrates an increase in SNR of 1.39 d B and 4.66 d B,respectively,along with a reduction in the root-meansquare error(RMSE)of 35%and 64%,respectively.Additionally,there is a decrease in the spectral angle(SA)of 0.05 and 0.11,respectively.In the high-quality spectrum(SNR=43.96 d B)experiment,the results show that the running time of the proposed algorithm is reduced by about98%compared with the R-L iterative algorithm.Moreover,the maximum entropy algorithm avoids parameter optimization settings and is more suitable for automatic implementation.In conclusion,the proposed algorithm can accurately resolve Doppler spectrum details while effectively suppressing noise,thus highlighting its advantage in LIF spectral deconvolution applications.展开更多
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical...Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.展开更多
In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduce...In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduced electron transfer(PET)effect.Two perylene diimide isomers PDI-P and PDI-B were designed and synthesized,and their molecular structures were characterized by high-resolution Fourier transform mass spectrometry(HRMS),nuclear magnetic resonance hydrogen and carbon spectroscopy(~1H and~(13)C NMR).The interaction between ionizing radiation and fluorescent molecules was simulated by HCl titration.The results show that combining PDIs and HCl can improve fluorescence through the retro-PET process.Despite the similarities in chemical structures,the fluorescent enhancement multiple of PDI-B with aromatic amine as electron donor is much higher than that of PDI-P with alkyl amine.In the direct irradiation experiments of ionizing radiation,the emission enhancement multiples of PDI-P and PDI-B are 2.01 and 45.4,respectively.Furthermore,density functional theory(DFT)and time-dependent density functional theory(TDDFT)calculations indicate that the HOMO and HOMO-1 energy ranges of PDI-P and PDI-B are 0.54 e V and 1.13 e V,respectively.A wider energy range has a stronger driving force on electrons,which is conducive to fluorescence quenching.Both femtosecond transient absorption spectroscopy(fs-TAS)and transient fluorescence spectroscopy(TFS)tests show that PDI-B has shorter charge separation lifetime and higher electron transfer rate constant.Although both isomers can significantly reduce LOD during PET process,PDI-B with aromatic amine has a wider detection range of 0.118—240 Gy due to its larger emission enhancement,which is a leap of three orders of magnitude.It breaks through the detection range of gamma radiation reported in existing studies,and provides theoretical support for the further study of sensitive and effective new materials for ionizing radiation detection.展开更多
In energy-dispersive X-ray fluorescence spectroscopy,the estimation of the pulse amplitude determines the accuracy of the spectrum measurement.The error generated by the amplitude estimation of the pulse output distor...In energy-dispersive X-ray fluorescence spectroscopy,the estimation of the pulse amplitude determines the accuracy of the spectrum measurement.The error generated by the amplitude estimation of the pulse output distorted by the measurement system leads to false peaks in the measured spectrum.To eliminate these false peaks and achieve an accurate estimation of the distorted pulse amplitude,a composite neural network model is proposed,which embeds long and short-term memory(LSTM)into the UNet structure.The UNet network realizes the fusion of pulse sequence features and the LSTM model realizes pulse amplitude estimation.The model is trained using simulated pulse datasets with different amplitudes and distortion times.For the pulse height estimation,the average relative error of the trained model on the test set was approximately 0.64%,which is 27.37% lower than that of the traditional trapezoidal shaping algorithm.Offline processing of a standard iron source further validated the pulse height estimation performance of the UNet-LSTM model.After estimating the amplitude of the distorted pulses using the model,the false peak area was reduced by approximately 91% over the full spectrum and was corrected to the characteristic peak region of interest(ROI).The corrected peak area accounted for approximately 1.32%of the characteristic peak ROI area.The results indicate that the model can accurately estimate the height of distorted pulses and has substantial corrective effects on false peaks.展开更多
Tumor vaccine therapy offers significant advantages over conventional treatments,including reduced toxic side effects.However,it currently functions primarily as an adjuvant treatment modality in clinical oncology due...Tumor vaccine therapy offers significant advantages over conventional treatments,including reduced toxic side effects.However,it currently functions primarily as an adjuvant treatment modality in clinical oncology due to limitations in tumor antigen selection and delivery methods.Tumor vaccines often fail to elicit a sufficiently robust immune response against progressive tumors,thereby limiting their clinical efficacy.In this study,we developed a nanoparticle-based tumor vaccine,OVA@HA-PEI,utilizing ovalbumin(OVA)as the presenting antigen and hyaluronic acid(HA)and polyethyleneimine(PEI)as adjuvants and carriers.This formulation significantly enhanced the proliferation of immune cells and cytokines,such as CD3,CD8,interferon-,and tumor necrosis factor-,in vivo,effectively activating an immune response against B16–F10 tumors.In vivofluorescenceflow cytometry(IVFC)has already become an effective method for monitoring circulating tumor cells(CTCs)due to its direct,noninvasive,and long-term detection capabilities.Our study utilized a laboratory-constructed IVFC system to monitor the immune processes induced by the OVA@HA-PEI tumor vaccine and an anti-programmed death-1(PD-1)antibody.The results demonstrated that the combined treatment of OVA@HA-PEI and anti-PD-1 antibody significantly improved the survival time of mice compared to anti-PD-1 antibody treatment alone.Additionally,this combination therapy substantially reduced the number of CTCs in vivo,increased the clearance rate of CTCs by the immune system,and slowed tumor progression.Thesefindings greatly enhance the clinical application prospects of IVFC and tumor vaccines.展开更多
Optical imaging in the second near-infrared(NIR-II;900-1880 nm)window is currently a popular research topic in the field of biomedical imaging.This study aimed to explore the application value of NIR-II fluorescence i...Optical imaging in the second near-infrared(NIR-II;900-1880 nm)window is currently a popular research topic in the field of biomedical imaging.This study aimed to explore the application value of NIR-II fluorescence imaging in foot and ankle surgeries.A lab-established NIR-II fluorescence surgical navigation system was developed and used to navigate foot and ankle surgeries which enabled obtaining more high-spatial-frequency information and a higher signal-to-background ratio(SBR)in NIR-II fluorescence images compared to NIR-I fluorescence images;our result demonstrates that NIR-II imaging could provide higher-contrast and larger-depth images to surgeons.Three types of clinical application scenarios(diabetic foot,calcaneal fracture,and lower extremity trauma)were included in this study.Using the NIR-II fluorescence imaging technique,we observed the ischemic region in the diabetic foot before morphological alterations,accurately determined the boundary of the ischemic region in the surgical incision,and fully assessed the blood supply condition of the flap.NIR-II fluorescence imaging can help surgeons precisely judge surgical margins,detect ischemic lesions early,and dynamically trace the perfusion process.We believe that portable and reliable NIR-II fluorescence imaging equipment and additional functional fluorescent probes can play crucial roles in precision surgery.展开更多
Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation....Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.展开更多
A ratiometric fluorescent probe for hypoxanthine(Hx)detection was established based on the mimic enzyme and fluorescence characteristics of cobalt-doped graphite-phase carbon nitride(Co doped g-C_(3)N_(4)).In addition...A ratiometric fluorescent probe for hypoxanthine(Hx)detection was established based on the mimic enzyme and fluorescence characteristics of cobalt-doped graphite-phase carbon nitride(Co doped g-C_(3)N_(4)).In addition to emitting strong fluorescence,the peroxidase activity of Co doped g-C_(3)N_(4)can catalyze the reaction of O-phenylenediamine and H_(2)O_(2)to produce diallyl phthalate which can emit yellow fluorescence at 570 nm.Through the decomposition of Hx by xanthine oxidase,Hx can be indirectly detected by the generating hydrogen peroxide based on the measurement of fluorescent ratio I(F_(570)/F_(370)).The linear range was 1.7-272.2 mg/kg(R^(2)=0.997),and the detection limit was 1.52 mg/kg(3σ/K,n=9).The established method was applied to Hx detection in bass,grass carp,and shrimp,and the data were verified by HPLC.The result shows that the established probe is sensitive,accurate,and reliable,and can be used for Hx detection in aquatic products.展开更多
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th...Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy.展开更多
BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a n...BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.展开更多
基金supported by the Fundamental Re-search Funds for the Central Universities(HYGJXM202309).
文摘The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications.
文摘BACKGROUND Intraoperative and postoperative biliary injuries remain significant complications of laparoscopic common bile duct exploration(LCBDE).Indocyanine green(ICG)has been shown to significantly reduce injuries caused by intraoperative operational errors.We found that the J-tube can reduce postoperative strictures and injuries to the common bile duct.At this moment,we aim to analyze and compare the complications,efficacy,short-term outcomes,and feasibility of these two adjunctive tools for LCBDE.AIM To evaluate the efficacy of ICG fluorescence imaging In LCBDE and J-tube drainage for patients with common bile duct stones.METHODS We retrospectively collected the clinical case data of patients who were treated at the Hepatobiliary Surgery Department of the Third People’s Hospital of Nantong,affiliated with Nantong University,from January 2016 to January 2021 due to gallbladder stones with choledocholithiasis and who underwent LCBDE combined with a primary suture and either J-tube or T-tube drainage.The patients were divided into groups:Traditional white-light laparoscopy+T-tube group(WL+T-tube),traditional WL+J-tube group,fluorescent laparoscopy+T-tube group(ICG+T-tube)and fluorescent laparoscopy+J-tube group(ICG+J-tube).The preoperative and postoperative clinical case data,laboratory examination data,and intraoperative and postoperative complications(including postoperative bile leakage,electrolyte disturbances,biliary peritonitis,and postoperative infections)and other relevant indicators were compared.RESULTS A total of 198 patients(112 males and 86 females)were included in the study,with 74 patients in the WL+T-tube,47 in the WL+J-tube,42 in the ICG+T-tube,and 35 in the ICG+J-tube.Compared with the other groups,the ICG+J had significantly shorter operation time(114 minutes,P=0.001),less blood loss(42 mL,P=0.02),shorter postoperative hospital stays(7 days,P=0.038),and lower surgical costs(China yuan 30178,P=0.001).Furthermore,patients were subdivided into two groups based on whether a T-tube or J-tube was placed during the surgery.By the third postoperative day,the aspartate transaminase,glutamic pyruvic transaminase,total bilirubin,and direct bilirubin levels were lower in the J-tube group than in the T-tube group(P<0.001).At last,follow-up observations showed that the incidence of biliary strictures at three months postoperatively was significantly lower in the J-tube group than in the T-tube group(P=0.002).CONCLUSION ICG fluorescence imaging in laparoscopic cholecystectomy with common bile duct exploration and J-tube drainage facilitates rapid identification of biliary anatomy and variations,reducing intraoperative bile duct injury,blood loss,surgery duration,and postoperative bile duct stenosis rates,supporting its clinical adoption.
基金This work was supported by the National Natural Science Foundation of China(Nos.61735016,61975172,and 91632105)Zhejiang Provincial Natural Science Foundation of China(Nos.LR17F050001 and LY17C090005)the Fundamental Research Funds for the Central Universities and State Key Laboratory of Pathogenesis,Prevention and Treatment of High Incidence Diseases in Central Asia Fund(No.SKL-HIDCA-2019-3).
文摘It is of great significance to study the brain structure and function in deep-tissue for neuroscience research and bio-medical applications because of the urgent demand for precise theranostics.Three-photon fluorescence microscopic(3PFM)bioimaging excited by the light in near-infrared IIb(NIR-IIb,1,500–1,700 nm)spectral region is one of the most promising imaging techniques with the advantages of high spatial resolution,large imaging depth,and reduced scattering.Herein,a type of NIR-IIb light excitable deep-red emissive semiconducting polymer dots(P-dots)with bright 3PF and large three-photon absorption cross-section(σ3)at 1,550 nm was prepared.Then the P-dots were functionalized with polystyrene polymer polystyrene graft ethylene oxide functionalized with carboxyl groups(PS-PEG-COOH)and modified with NH2-poly(ethylene glycol)(PEG)to synthesis photochemically stable and biocompatible P-dots nanoparticles(NPs).Further the P-dots NPs were utilized for in vivo 3PFM bioimaging of cerebral vasculature with and without the brain skull under 1,550 nm femtosecond(fs)laser excitation.In vivo 3PFM bioimaging of the mice cerebral vasculature at various vertical depths was obtained.Moreover,a vivid three-dimensional structure of the mice vascular architecture beneath the skull was reconstructed.At the depth of 350μm beneath the brain skull,3.8μm blood vessels could still be clearly recognized.NIR-IIb excitable P-dots assisted 3PFM bioimaging has great potential in accurate deep tissue bioimaging.
基金This work was supported by the National Basic Research Program of China (973 Program) (No. 2013CB834704), the National Natural Science Foundation of China (No. 61275190), the Program of Zhejiang Leading Team of Science and Technology Innovation (No. 2010R50007), the Fundamental Research Funds for the Central Universities, the Open Fund of the State Key Laboratory of Luminescent Materials and Devices (South China University of Technology), and the Research Grants Council of Hong Kong (No. HKUST2/CRF/10).
文摘Aggregation-induced emission (AIE) luminogen displays bright fluorescence and has photobleaching resistance in its aggregation state. It is an ideal fluorescent contrast agent for bioimaging. Multiphoton microscopy is an important tool for bioimaging since it possesses the ability to penetrate deep into biological tissues. Herein, we used AIE luminogen together with multiphoton microscopy for long-term imaging of zebrafish. A typical AIE luminogen, 2,3-bis(4-(phenyl(4- (1,Z2-triphenylvinyl) phenyl)amino)phenyl) fumaronitrile (TPE-TPA-FN or TTF), was encapsulated with 1,2-distearoyl-sn-glycero-3-phosphoethanola-mine-N- [methoxy(polyethylene glycol)-2000] (DSPE-mPEG2000) to form nanodots that exhibited bright three-photon fluorescence under 1,560 nm-femtosecond (fs) laser excitation. The TTF-nanodots were chemically stable in a wide range of pH values and showed no in vivo toxicity in zebrafish according to a series of biological tests. The TTF-nanodots were microinjected into zebrafish embryos, and the different growth stages of the labeled embryos were monitored with a three-photon fluorescence microscope. TTF-nanodots could be traced inside the zebrafish body for as long as 120 hours. In addition, the TTF-nanodots were utilized to target the blood vessel of zebrafish, and three-photon fluorescence angiogram was performed. More importantly, these nanodots were highly resistant to photobleaching under 1,560 nm-fs excitation, allowing long-term imaging of zebrafish.
基金funded by the National Natural Science Foundation of China(62075135,61975126)Shenzhen Key Laboratory of Photonics and Biophotonics(ZDSYS20210623092006020).
文摘White matter,a densely packed collection of myelinated axons,plays an essential part in neural networks.With high spatial resolution and deep penetration,multi-photon microscopy(MPM)is promising for white matter imaging in animal models in vivo.The third harmonic generation(THG)signal can be generated from white matter,but the bottom part of the white matter layer generates weak THG due to its high scattering.Here,we demonstrate an in vivo labeling and imaging technology,capable of visualizing the white matter layer in the mouse brain,combining°uorescence labeling with MitoTracker Red and three-photon°uorescence(3PF)microscopy excited at the 1700 nm window.3PF signals are several times higher than THG signals,resulting in deeper imaging of the white matter layer with the former.Our results indicate that 3PF microscopy is a promising technology for white matter imaging in the deep brain in vivo.
基金supported by the National Key R&D Program of China(No.2020YFA0710700)the National Natural Science Foundation of China(Nos.51873201 and 82172071)+2 种基金Key Research and Development Program of Anhui Province(No.202104b11020025)the Fundamental Research Funds for the Central Universities(No.YD2060002015)the CAS Youth Interdisciplinary Team(No.JCTD-2021-08).
文摘In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction.
基金supported by Major Science and Technology Project of Yunnan Province(202302AE090022)Key Research and Development Program of Yunnan(202203AC100010)+4 种基金the National Natural Science Foundation of China(32160597,32160236,32371463)National Key Research and Development Program of China(2022YFC2601604)Cardiovascular Ultrasound Innovation Team of Yunnan Province(202305AS350021)Spring City Plan:the High-Level Talent Promotion and Training Project of Kunming(2022SCP001)Graduate Tutor Team of Yunnan Province,and the Second Phase of"Double-First Class"Program Construction of Yunnan University.
文摘Chymosin is one of the critical enzymes in cheese making.Herein,we proposed a novel fluorometric assay for chymosin determination.Firstly,covalent organic frameworks(COF)were synthesized and exfoliated to 2-dimensional COF nanosheets(COF NS)by ultrasound treatment.Gold nanoparticles(Au NPs)were loaded with COF NS to prepare AuNPs/COF NS(Au@COF NS).Secondly,rhodamine B(RhB)modified substrate peptide(Pep)for chymosin was linked with Au@COF NS to construct a Pep-Au@COF NS nanocomposite.For the sensing principle,fluorescence of RhB was quenched by Au@COF NS and the fluorescence intensity was weak due to the fluorescence resonance energy transfer between COF NS and RhB of Pep.However,in the presence of chymosin,the RhB was released by specific cleavage of the substrate peptide by chymosin and resulted in the recovery of fluorescence.The increased fluorescence intensity was proportional to the increase of chymosin concentration and thus a“turn on”fluorescent sensor for chymosin was constructed.The sensor showed a linear range in the concentration of 0.05-60.00μg/mL for the detection of chymosin with a detection limit of 20 ng/mL.The sensor was used to quantify chymosin in rennet product with good selectivity,which has the potential applications in cheese manufacturing.
基金Supported by the National High Level Hospital Clinical Research Funding,No.2022-PUMCH-B-003Beijing Technology Innovation Foundation for University or College Students,No.2022zglc06062.
文摘BACKGROUND Near-infrared fluorescence imaging via using intravenous indocyanine green(ICG)has a wide range of applications in multiple surgical scenarios.In lapa-roscopic cholecystectomy(LC),it facilitates intraoperative identification of the biliary system and reduces the risk of bile duct injury.However,the usual single color fluorescence imaging(SCFI)has limitations in manifesting the fluorescence signal of the target structure when its intensity is relatively low.Moreover,sur-geons often experience visual fatigue.We hypothesized that a novel imaging stra-tegy,named multi-color fluorescence imaging(MCFI),could potentially address these issues by decreasing hepatic and background fluorescence pollution and improving biliary visualization.AIM To investigate the novel imaging strategy MCFI in LC.METHODS This was a single-center retrospective study conducted at Peking Union Medical College Hospital,Beijing,China.Patients who underwent LC from June 2022 to March 2023 by the same surgical team were enrolled.Demographic features,clinical and surgical information were collected.The clarity,visual comfort,and effectiveness of different imaging strategies were subjectively evaluated by surgeons.RESULTS A total of 155 patients were included,60 patients were in the non-ICG group in which only bright light illuminance without ICG was applied,60 patients were in the SCFI group,and 35 patients were in the MCFI group.No statist-ically significant differences were found in demographics or clinical history.Post-surgical complications were minimal in all 3 groups with no significant differences observed.MCFI improved the clarity of imaging and visual comfort.Clarity of imaging and visual comfort were improved with MCFI.CONCLUSION MCFI improves biliary visualization and reduces liver fluorescence contamination,which supports its routine use in LC.MCFI may also be a better choice than SCFI in other clinical settings.
基金supported by the Education Department of Zhejiang Province (20050359)
文摘A near infrared to visible blue, green, and red upconversion luminescence in a Tb^3+-doped CaO-Al2O3-SiO2 glass was studied, which was excited using 800 nm femtosecond laser irradiation. The upconversion luminescence was attributed to ^5D3→^7F5, ^5D3→^7F4, ^5D3→^7F3, ^5D4→^7F6, ^5D4→^7F5, ^5D4→^7F4, and ^5D4→^7F3 transitions of Tb^3+. The relationship between upconversion luminescence intensity and the pump power indicated that a three-photon simultaneous absorption process was dominant in this upconversion luminescence. The intense red, green, and blue upconversion luminescence of Tb^3+-doped CaO-Al2O3-SiO2 glass may be potentially useful in developing three-dimensional display applications.
基金supported by National Natural Science Foundation of China(61975172,82001874 and 61735016).
文摘Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation.
文摘Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvolution becomes invalid in the presence of noise as it leads to infinite amplification of high-frequency noise components.To address this issue,we propose a deconvolution algorithm based on the maximum entropy principle.We validate the effectiveness of the proposed algorithm by utilizing simulated LIF spectra at various noise levels(signal-to-noise ratio,SNR=20–80 d B)and measured LIF spectra with Xe as the working fluid.In the typical measured spectrum(SNR=26.23 d B)experiment,compared with the Gaussian filter and the Richardson–Lucy(R-L)algorithm,the proposed algorithm demonstrates an increase in SNR of 1.39 d B and 4.66 d B,respectively,along with a reduction in the root-meansquare error(RMSE)of 35%and 64%,respectively.Additionally,there is a decrease in the spectral angle(SA)of 0.05 and 0.11,respectively.In the high-quality spectrum(SNR=43.96 d B)experiment,the results show that the running time of the proposed algorithm is reduced by about98%compared with the R-L iterative algorithm.Moreover,the maximum entropy algorithm avoids parameter optimization settings and is more suitable for automatic implementation.In conclusion,the proposed algorithm can accurately resolve Doppler spectrum details while effectively suppressing noise,thus highlighting its advantage in LIF spectral deconvolution applications.
文摘Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers.
基金financial support from the National Natural Science Foundation of China(Grant No.21801016)the Science and Technology on Applied Physical Chemistry Laboratory(Grant No.6142602220304)。
文摘In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduced electron transfer(PET)effect.Two perylene diimide isomers PDI-P and PDI-B were designed and synthesized,and their molecular structures were characterized by high-resolution Fourier transform mass spectrometry(HRMS),nuclear magnetic resonance hydrogen and carbon spectroscopy(~1H and~(13)C NMR).The interaction between ionizing radiation and fluorescent molecules was simulated by HCl titration.The results show that combining PDIs and HCl can improve fluorescence through the retro-PET process.Despite the similarities in chemical structures,the fluorescent enhancement multiple of PDI-B with aromatic amine as electron donor is much higher than that of PDI-P with alkyl amine.In the direct irradiation experiments of ionizing radiation,the emission enhancement multiples of PDI-P and PDI-B are 2.01 and 45.4,respectively.Furthermore,density functional theory(DFT)and time-dependent density functional theory(TDDFT)calculations indicate that the HOMO and HOMO-1 energy ranges of PDI-P and PDI-B are 0.54 e V and 1.13 e V,respectively.A wider energy range has a stronger driving force on electrons,which is conducive to fluorescence quenching.Both femtosecond transient absorption spectroscopy(fs-TAS)and transient fluorescence spectroscopy(TFS)tests show that PDI-B has shorter charge separation lifetime and higher electron transfer rate constant.Although both isomers can significantly reduce LOD during PET process,PDI-B with aromatic amine has a wider detection range of 0.118—240 Gy due to its larger emission enhancement,which is a leap of three orders of magnitude.It breaks through the detection range of gamma radiation reported in existing studies,and provides theoretical support for the further study of sensitive and effective new materials for ionizing radiation detection.
基金supported by the Open Project of Guangxi Key Laboratory of Nuclear Physics and Nuclear Technology(No.NLK2022-05)the Central Government Guidance Funds for Local Scientific and Technological Development,China(No.Guike ZY22096024)+5 种基金the Sichuan Natural Science Youth Fund Project(No.2023NSFSC1366)Key R&D Projects of Sichuan Provincial Department of Science and Technology(No.2023YFG0287)the Open Research Fund of National Engineering Research Center for Agro-Ecological Big Data Analysis&Application,Anhui University(No.AE202209)the National Natural Science Youth Foundation of China(No.12305214)the Vanadium and Titanium Resource Comprehensive Utilization Key Laboratory of Sichuan Province(No.2023FTSZ03)the Key Laboratory of Interior Layout optimization and Security,Institutions of Higher Education of Sichuan Province(No.2023SNKJ-01)。
文摘In energy-dispersive X-ray fluorescence spectroscopy,the estimation of the pulse amplitude determines the accuracy of the spectrum measurement.The error generated by the amplitude estimation of the pulse output distorted by the measurement system leads to false peaks in the measured spectrum.To eliminate these false peaks and achieve an accurate estimation of the distorted pulse amplitude,a composite neural network model is proposed,which embeds long and short-term memory(LSTM)into the UNet structure.The UNet network realizes the fusion of pulse sequence features and the LSTM model realizes pulse amplitude estimation.The model is trained using simulated pulse datasets with different amplitudes and distortion times.For the pulse height estimation,the average relative error of the trained model on the test set was approximately 0.64%,which is 27.37% lower than that of the traditional trapezoidal shaping algorithm.Offline processing of a standard iron source further validated the pulse height estimation performance of the UNet-LSTM model.After estimating the amplitude of the distorted pulses using the model,the false peak area was reduced by approximately 91% over the full spectrum and was corrected to the characteristic peak region of interest(ROI).The corrected peak area accounted for approximately 1.32%of the characteristic peak ROI area.The results indicate that the model can accurately estimate the height of distorted pulses and has substantial corrective effects on false peaks.
基金supported by the National Key Research and Development Program of China,Grant Number:2021YFF0502900,2019YFC1604604National Natural Science Foundation of China,Grant Number:62075013,62027824.
文摘Tumor vaccine therapy offers significant advantages over conventional treatments,including reduced toxic side effects.However,it currently functions primarily as an adjuvant treatment modality in clinical oncology due to limitations in tumor antigen selection and delivery methods.Tumor vaccines often fail to elicit a sufficiently robust immune response against progressive tumors,thereby limiting their clinical efficacy.In this study,we developed a nanoparticle-based tumor vaccine,OVA@HA-PEI,utilizing ovalbumin(OVA)as the presenting antigen and hyaluronic acid(HA)and polyethyleneimine(PEI)as adjuvants and carriers.This formulation significantly enhanced the proliferation of immune cells and cytokines,such as CD3,CD8,interferon-,and tumor necrosis factor-,in vivo,effectively activating an immune response against B16–F10 tumors.In vivofluorescenceflow cytometry(IVFC)has already become an effective method for monitoring circulating tumor cells(CTCs)due to its direct,noninvasive,and long-term detection capabilities.Our study utilized a laboratory-constructed IVFC system to monitor the immune processes induced by the OVA@HA-PEI tumor vaccine and an anti-programmed death-1(PD-1)antibody.The results demonstrated that the combined treatment of OVA@HA-PEI and anti-PD-1 antibody significantly improved the survival time of mice compared to anti-PD-1 antibody treatment alone.Additionally,this combination therapy substantially reduced the number of CTCs in vivo,increased the clearance rate of CTCs by the immune system,and slowed tumor progression.Thesefindings greatly enhance the clinical application prospects of IVFC and tumor vaccines.
基金supported by the Fundamental Research Fund for the Central Universities(K20220220)the National Key Research and Development Program of China(2018YFC1005003,2018YFE0190200,and 2022YFB3206000)+4 种基金the National Natural Science Foundation of China(U23A20487,82001874,61975172,and 82102105)the Zhejiang Engineering Research Center of Cognitive Healthcare(2017E10011)the Natural Science Foundation of Zhejiang Province(LQ22H160017)the Zhejiang Province Science and Technology Plan Project(2022C03134)the Science and Technology Innovation 2030 Plan Project(2022ZD0160703).
文摘Optical imaging in the second near-infrared(NIR-II;900-1880 nm)window is currently a popular research topic in the field of biomedical imaging.This study aimed to explore the application value of NIR-II fluorescence imaging in foot and ankle surgeries.A lab-established NIR-II fluorescence surgical navigation system was developed and used to navigate foot and ankle surgeries which enabled obtaining more high-spatial-frequency information and a higher signal-to-background ratio(SBR)in NIR-II fluorescence images compared to NIR-I fluorescence images;our result demonstrates that NIR-II imaging could provide higher-contrast and larger-depth images to surgeons.Three types of clinical application scenarios(diabetic foot,calcaneal fracture,and lower extremity trauma)were included in this study.Using the NIR-II fluorescence imaging technique,we observed the ischemic region in the diabetic foot before morphological alterations,accurately determined the boundary of the ischemic region in the surgical incision,and fully assessed the blood supply condition of the flap.NIR-II fluorescence imaging can help surgeons precisely judge surgical margins,detect ischemic lesions early,and dynamically trace the perfusion process.We believe that portable and reliable NIR-II fluorescence imaging equipment and additional functional fluorescent probes can play crucial roles in precision surgery.
文摘Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure.
基金supported by the National Natural Science Foundation of China(21804050)the National Key R and D Program of China(2018YFD0901003)+2 种基金the Science and Technology Planning Project of Xiamen,China(3502Z20183031)the Fujian Provincial Fund Project(2018J01432)the Xiamen Science and Technology Planning Project,China(3502Z20183031)。
文摘A ratiometric fluorescent probe for hypoxanthine(Hx)detection was established based on the mimic enzyme and fluorescence characteristics of cobalt-doped graphite-phase carbon nitride(Co doped g-C_(3)N_(4)).In addition to emitting strong fluorescence,the peroxidase activity of Co doped g-C_(3)N_(4)can catalyze the reaction of O-phenylenediamine and H_(2)O_(2)to produce diallyl phthalate which can emit yellow fluorescence at 570 nm.Through the decomposition of Hx by xanthine oxidase,Hx can be indirectly detected by the generating hydrogen peroxide based on the measurement of fluorescent ratio I(F_(570)/F_(370)).The linear range was 1.7-272.2 mg/kg(R^(2)=0.997),and the detection limit was 1.52 mg/kg(3σ/K,n=9).The established method was applied to Hx detection in bass,grass carp,and shrimp,and the data were verified by HPLC.The result shows that the established probe is sensitive,accurate,and reliable,and can be used for Hx detection in aquatic products.
基金supported by the National Natural Science Foundation of China(Nos.12375157,12027902,and 11905011)。
文摘Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy.
文摘BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity.