Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper...Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper respiratory tract disease(URTD)and virulent systemic disease(FCV-VSD)[1].Infected cats usually presented with mouth ulcers,salivation and gingivitis-stomatitis.Furthermore,both recovered cats and asymptomatic carriers can still carry and spread the FCV virus for extended periods of time,contributing to the potential for outbreak.This presented a significant threat to the health and lives of cats,and rare wildlife and took a heavy financial loss on the pet industry,making the prevention and control of the virus difficult.Hence,rapid identification of FCV in clinical samples was necessary to prevent the spread of FCV and avoid financial loss.展开更多
A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including differe...A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.展开更多
Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and ...Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and complex.Here,we utilize a cryogenic optical system equipped with a high-spatial-resolution microscope to characterize surface strains in iron-based superconductors using the digital image correlation method.Compared with other methods such as high-resolution x-ray diffraction,strain gauge,and capacitive sensor,digital image correlation offers a non-contact full-field measurement approach,acting as an optical virtual strain gauge that provides high spatial resolution.The results measured on detwinned BaFe_(2)As_(2)are quantitatively consistent with the distortion measured by x-ray diffraction and neutron Larmor diffraction.These findings highlight the potential of cryogenic digital image correlation as an effective and accessible tool for probing the isotropic and anisotropic strains,facilitating applications of uniaxial strain tuning in research of quantum materials.展开更多
Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affec...Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.展开更多
A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparis...A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe.展开更多
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be...In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.展开更多
A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examina...A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examination of this probe revealed its attributes and factors affecting its performance.By using temperature modulation,the probe was adept at detecting DCP concentrations ranging between 1.0×10^(-6)and 9.0×10^(-6)mol/L.Such a probe offers remarkable selectivity,repeatability,and robust stability,so that the detection of DCP can be carried out at different temperatures,and a fast,reliable,sensitive and low-cost intelligent detection method is realized.展开更多
An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the...An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP).展开更多
Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluor...Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluorescence of terbium ions(Tb^(3+))via binding with single-strand DNA.Mercury ion,Hg^(2+)induced thymine(T)-rich DNA strand to form a double-strand structure(T-Hg^(2+)-T),thus leading to fluorescence reduction.Based on the principle,Hg^(2+)can be quantified based on the fluorescence of Tb^(3+),the limit of detection was 0.0689μmol/L and the linear range was 0.1-6.0μmol/L.Due to the specificity of T-Hg^(2+)-T artificial base pair,the assay could distinguish Hg^(2+)from other metal ions.The recovery rate was ranged in 98.71%-101.34%for detecting mercury pollution in three food samples.The assay is low-cost,separation-free and mix-to-read,thus was a competitive tool for detection of mercury pollution to ensure food safety.展开更多
Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,...Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,the rigid neural probes,such as Utah arrays,Michigan probes,and metal microfilament electrodes,are mechanically unmatched with brain tissue and are prone to rejection and glial scarring after implantation,which leads to a significant degradation in the signal quality with the implantation time.In recent years,flexible neural electrodes are rapidly developed with less damage to biological tissues,excellent biocompatibility,and mechanical compliance to alleviate scarring.Among them,the mechanical modeling is important for the optimization of the structure and the implantation process.In this review,the theoretical calculation of the flexible neural probes is firstly summarized with the processes of buckling,insertion,and relative interaction with soft brain tissue for flexible probes from outside to inside.Then,the corresponding mechanical simulation methods are organized considering multiple impact factors to realize minimally invasive implantation.Finally,the technical difficulties and future trends of mechanical modeling are discussed for the next-generation flexible neural probes,which is critical to realize low-invasiveness and long-term coexistence in vivo.展开更多
Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assist...Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assisted methods are important approaches for RNA direct detection,but its specificity will be limited when the fidelity of ligases is not ideal.The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection.Methods In this study,a dualcompetitive-padlock-probe(DCPLP)assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation.To verify the method,we employed dual competitive padlock probe-mediated rolling circle amplification(DCPLP-RCA)to genotype the CYP2C9 gene.Results The specificity was well improved through the competition and strand displacement of dual padlock probe,with an 83.26%reduction in nonspecific signal.By detecting synthetic RNA samples,the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L.Furthermore,clinical samples were applied to the method to evaluate its performance,and the genotyping results were consistent with those obtained using the qPCR method.Conclusion This study has successfully established a highly specific direct RNA SNP detection method,and provided a novel avenue for accurate identification of various types of RNAs.展开更多
The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA)....The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53.展开更多
Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied o...Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied on advanced equipment.Herein,we develop a fast,convenient,high-selective fluorescence detection method based on metal-organic cages(MOC),whose emission is enhanced by nearly 20 times in the presence of LiPF_(6)with good stability and photobleaching resistance.The fluorescent probe can also detect moisture in battery electrolyte.We propose and verify that the luminescence enhancement is due to the presence of hydrogen bond-induced enhanced emission effect in cages.Fluorescent excitation-emission matrix spectra and variable-temperature nuclear magnetic resonance spectroscopy are employed to clarify the role of hydrogen bonds in guest-loaded cages.Density functional theory(DFT)calculation is applied to simulate the structure of host-guest complexes and estimate the adsorption energy involved in the system.The precisely matched lock-and-key model paves a new way for designing and fabricating novel host structures,enabling specific recognition of other target compounds.展开更多
AIM:To directly quantify peroxynitrite(ONOO-)using a highly sensitive fluorescence resonance energy transfer probe RN-NA,investigate the association between ONOOand primary open angle glaucoma(POAG),and clarify whethe...AIM:To directly quantify peroxynitrite(ONOO-)using a highly sensitive fluorescence resonance energy transfer probe RN-NA,investigate the association between ONOOand primary open angle glaucoma(POAG),and clarify whether RN-NA could be used as a potential tool for POAG diagnosis.METHODS:Plasma and aqueous humor(AH)samples were collected from POAG patients(n=100,age:59.70±6.87y)and age-related cataract(ARC)patients(n=100,age:61.15±4.60y)admitted to our hospital.Next,RN-NA was used to detect ONOO-in plasma and AH samples,and the relationship between ONOO-level and POAG was analyzed using binary logistic regression.Besides,Pearson correlation analysis was applied to characterize the correlation of the levels of ONOO-with the patients’age,intraocular pressure(IOP),and mean deviation of visual field testing.The ONOO-scavenger MnTMPyP was employed to treat the 3-morpholinosyndnomine(SIN-1)-induced ocular hypertension in mice(n=7,6-8wk).Finally,the IOP and ONOO-in both eyes were measured 30min after the last drug treatment.RESULTS:ONOO-levels of AH and plasma were significantly higher in the POAG group than in the ARC group(P<0.01).Additionally,ONOO-levels were closely correlated with POAG in a binary logistic regression analysis[odds ratio(OR)=1.008,95%confidence interval(CI):1.002-1.013,P<0.01 for AH;OR=1.004,95%CI:1.002-1.006,P<0.001 for plasma].Pearson correlation analysis showed that ONOO-levels in AH or plasma were positively associated with visual field defects(R=0.51,P<0.01 for AH;R=0.45,P<0.001 for plasma),and ONOO-levels in plasma and AH were correlated in the POAG group(R=0.69,P<0.001).However,administering MnTMPyP to mouse eyes reversed the elevated IOP caused by SIN-1(P<0.05).CONCLUSION:ONOO-levels in AH and plasma,detected by RN-NA,are significantly related to POAG and positively correlated with visual field defects in POAG patients.Hence,ONOO-is a potential biomarker of POAG,especially advanced POAG.Besides,anti-nitration compounds may be novel ocular hypotensive agents based on the animal study.展开更多
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In...Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.展开更多
The long-period-stacking-ordered(LPSO)structure affects the mechanical,corrosion and hydrolysis properties of Mg alloys.The current work employs high angle annular dark field-scanning transmission electron microscopy(...The long-period-stacking-ordered(LPSO)structure affects the mechanical,corrosion and hydrolysis properties of Mg alloys.The current work employs high angle annular dark field-scanning transmission electron microscopy(HAADF-STEM)and atom probe tomography(APT)to investigate the structural and local chemical information of LPSO phases formed in Mg-Ni-Y/Sm ternary alloys after extended isothermal annealing.Depending on the alloying elements and their concentrations,Mg-Ni-Y/Sm develops a two-phase LPSO+α-Mg structure in which the LPSO phase contains defects,hybrid LPSO structure,and Mg insertions.HAADF-STEM and APT indicate non-stoichiometric LPSO with incomplete Ni_(6)(Y/Sm)_(8) clusters.In addition,the APT quantitatively determines the local composition of LPSO and confirms the presence of Ni within the Mg bonding layers.These results provide insight into a better understanding of the structure and hydrolysis properties of LPSO-Mg alloys.展开更多
Conventional conductivity methods for measuring the void fraction in gas-liquid multiphase systems are typically affected by accuracy problems due to the presence of fluid flow and salinity.This study presents a novel...Conventional conductivity methods for measuring the void fraction in gas-liquid multiphase systems are typically affected by accuracy problems due to the presence of fluid flow and salinity.This study presents a novel approach for determining the void fraction based on a reciprocating dynamic conductivity probe used to measure the liquid film thickness under forced annular-flow conditions.The measurement system comprises a cyclone,a conductivity probe,a probe reciprocating device,and a data acquisition and processing system.This method ensures that the flow pattern is adjusted to a forced annular flow,thereby minimizing the influence of complex and variable gas-liquid flow patterns on the measurement results;Moreover,it determines the liquid film thickness solely according to circuit connectivity rather than specific conductivity values,thereby mitigating the impact of salinity.The reliability of the measurement system is demonstrated through laboratory experiments.The experimental results indicate that,in a range of gas phase superficial velocities 5–20 m/s and liquid phase superficial velocities 0.079–0.48 m/s,the maximum measurement deviation for the void fraction is 4.23%.展开更多
An exploratory multinuclear magnetic resonance(MR)and magnetic resonance imaging(MRI)study was performed on lithium-ion battery cells with ^(7)Li,^(19)F,and ^(1)H measurements.A variable field superconducting magnet w...An exploratory multinuclear magnetic resonance(MR)and magnetic resonance imaging(MRI)study was performed on lithium-ion battery cells with ^(7)Li,^(19)F,and ^(1)H measurements.A variable field superconducting magnet with a fixed frequency parallel-plate radiofrequency(RF)probe was employed in the study.The magnetic field was changed to set the resonance frequency of each nucleus to the fixed RF probe frequency of 33.7 MHz.Two cartridge-like lithium-ion cells,with graphite anodes and LiNi_(0.5)Mn_(0.3)Co_(0.2)O_(2)(NMC)cathodes,were interrogated.One cell was pristine,and one was charged to a cell voltage of 4.2 V.The results presented demonstrate the great potential of the variable field magnet approach in multinuclear measurement of lithium-ion batteries.These methods open the door for developing faster and simpler methods for detecting,quantifying,and interpreting MR and MRI data from lithium-ion and other batteries.展开更多
BACKGROUND The functional lumen imaging probe(FLIP)is a Food and Drug Administration approved tool to aid the diagnosis and management of esophageal disorders.However,widespread adoption of FLIP remains limited and it...BACKGROUND The functional lumen imaging probe(FLIP)is a Food and Drug Administration approved tool to aid the diagnosis and management of esophageal disorders.However,widespread adoption of FLIP remains limited and its utility in highvolume practices remains unclear.AIM To analyze large sample data on clinical use of FLIP and provide insight on several technical aspects when performing FLIP.METHODS We conducted a retrospective comparative and descriptive analysis of FLIP procedures performed by a single provider at an academic medical center.There was a total of 398 FLIP procedures identified.Patient medical records were reviewed and data regarding demographics and procedural details were collected.Statistical tests,including chi-squared,t-test,and multivariable logistic and linear regression,were performed.RESULTS There was an increase in FLIP cases with each successive time period of 13 months(n=68,146,184,respectively)with notable rises specifically for indications of dysphagia and gastroesophageal reflux disease.There was a shift toward use of the longer FLIP balloon catheter for diagnostic purposes(overall 70.4%vs 29.6%,P<0.01).Many cases(42.8%)were performed in conjunction with other diagnostics/interventions,such as dilation and wireless pH probe placement.Procedures were nearly equally performed with anesthesia vs moderate sedation(51.4%anesthesia),with no major complications.Patients who had anesthesia were less likely to have recurrent antegrade contractions[odds ratio(OR)=0.4,95%CI:0.3-0.8]and were also more likely to have absent contractility(OR=2.4,95%CI:1.3-CONCLUSION FLIP cases have increased in our practice with expanding indications for its use.Given limited normative data,providers should be aware of several potential technical issues,including the possible impact of sedation choice when assessing esophageal motility patterns.展开更多
基金supported by the natural science foundation reserve project of Jiangsu Agri-animal Husbandry Vocational College(No.NSF2023CB14).
文摘Feline calicivirus(FCV)was a highly prevalent RNA virus causing upper respiratory tract infections in cats through the mouth and nose around the world,result in the death of cats especially under 1 year old with upper respiratory tract disease(URTD)and virulent systemic disease(FCV-VSD)[1].Infected cats usually presented with mouth ulcers,salivation and gingivitis-stomatitis.Furthermore,both recovered cats and asymptomatic carriers can still carry and spread the FCV virus for extended periods of time,contributing to the potential for outbreak.This presented a significant threat to the health and lives of cats,and rare wildlife and took a heavy financial loss on the pet industry,making the prevention and control of the virus difficult.Hence,rapid identification of FCV in clinical samples was necessary to prevent the spread of FCV and avoid financial loss.
基金Supported by Gansu Provincial Natural Science Foundation of China(Grant No.22JR5RA229)National Natural Science Foundation of China(Grant Nos.51807086,12162021)Hongliu Youth Found of Lanzhou University of Technology and Gansu Provincial Outstanding Graduate Student Innovation Star of China(Grant No.2021CXZX-453).
文摘A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.
基金supported by the National Key Research and Development Program of China(Grant No.2021YFA1400400)the Fundamental Research Funds for the Central Universities,and the National Natural Science Foundation of China(Grant Nos.12174029 and 11922402).
文摘Uniaxial strain is a powerful tuning parameter that can control symmetry and anisotropic electronic properties in iron-based superconductors.However,accurately characterizing anisotropic strain can be challenging and complex.Here,we utilize a cryogenic optical system equipped with a high-spatial-resolution microscope to characterize surface strains in iron-based superconductors using the digital image correlation method.Compared with other methods such as high-resolution x-ray diffraction,strain gauge,and capacitive sensor,digital image correlation offers a non-contact full-field measurement approach,acting as an optical virtual strain gauge that provides high spatial resolution.The results measured on detwinned BaFe_(2)As_(2)are quantitatively consistent with the distortion measured by x-ray diffraction and neutron Larmor diffraction.These findings highlight the potential of cryogenic digital image correlation as an effective and accessible tool for probing the isotropic and anisotropic strains,facilitating applications of uniaxial strain tuning in research of quantum materials.
基金supported by the National Natural Science Foundation of China(82072432)the China-Japan Friendship Hospital Horizontal Project/Spontaneous Research Funding(2022-HX-JC-7)+1 种基金the National High Level Hospital Clinical Research Funding(2022-NHLHCRF-PY-20)the Elite Medical Professionals project of China-Japan Friendship Hospital(ZRJY2021-GG12).
文摘Rheumatoid arthritis(RA)is a systemic autoimmune disease that is primarily manifested as synovitis and polyarticular opacity and typically leads to serious joint damage and irreversible disability,thus adversely affecting locomotion ability and life quality.Consequently,good prognosis heavily relies on the early diagnosis and effective therapeutic monitoring of RA.Activatable fluorescent probes play vital roles in the detection and imaging of biomarkers for disease diagnosis and in vivo imaging.Herein,we review the fluorescent probes developed for the detection and imaging of RA biomarkers,namely reactive oxygen/nitrogen species(hypochlorous acid,peroxynitrite,hydroxyl radical,nitroxyl),pH,and cysteine,and address the related challenges and prospects to inspire the design of novel fluorescent probes and the improvement of their performance in RA studies.
基金Project supported by the National Natural Science Foundation of China (Grant No.11905076)S&T Program of Hebei (Grant No.SZX2020034)。
文摘A novel emissive probe consisting of an oxide cathode coating is developed to achieve a low operating temperature and long service life.The properties of the novel emissive probe are investigated in detail,in comparison with a traditional tungsten emissive probe,including the operating temperature,the electron emission capability and the plasma potential measurement.Studies of the operating temperature and electron emission capability show that the tungsten emissive probe usually works at a temperature of 1800 K-2200 K while the oxide cathode emissive probe can function at about 1200 K-1400 K.In addition,plasma potential measurements using the oxide cathode emissive probe with different techniques have been accomplished in microwave electron cyclotron resonance plasmas with different discharge powers.It is found that a reliable plasma potential can be obtained using the improved inflection point method and the hot probe with zero emission limit method,while the floating point method is invalid for the oxide cathode emissive probe.
基金supported in part by the National Natural Science Foundation of China under Grants 61975091,61905015,61575108,and 61505034by the Tsinghua Precision Medicine Foundation and“Bio-Brain+X”Advanced Imaging Instrument Development Seed Grant.
文摘In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus.
基金Funded by the Natural Science Foundation of Hubei Province(No.2022CFB861)the Wenhua College Research and Innovation Team(No.2022T01)。
文摘A composite was created by incorporating the quantum dot-enhanced SiO_(2)nanoparticles within this hydrogel.Based on this composite,a temperature-controlled fluorescent probe for DCP was developed.A meticulous examination of this probe revealed its attributes and factors affecting its performance.By using temperature modulation,the probe was adept at detecting DCP concentrations ranging between 1.0×10^(-6)and 9.0×10^(-6)mol/L.Such a probe offers remarkable selectivity,repeatability,and robust stability,so that the detection of DCP can be carried out at different temperatures,and a fast,reliable,sensitive and low-cost intelligent detection method is realized.
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFB2012600)the Science and Technology Plan Project of State Administration of Market Regulation,China(Grant No.2021MK039)。
文摘An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP).
基金financially supported by National Natural Science Foundation of China(22074100)the Young Elite Scientist Sponsorship Program by CAST(YESS20200036)+3 种基金the Researchers Supporting Project Number RSP-2021/138King Saud University,Riyadh,Saudi ArabiaTechnological Innovation R&D Project of Chengdu City(2019-YF05-31702266-SN)Sichuan University-Panzhihua City joint Project(2020CDPZH-5)。
文摘Mercury is a threatening pollutant in food,herein,we developed a Tb^(3+)-nucleic acid probe-based label-free assay for mix-and-read,rapid detection of mercury pollution.The assay utilized the feature of light-up fluorescence of terbium ions(Tb^(3+))via binding with single-strand DNA.Mercury ion,Hg^(2+)induced thymine(T)-rich DNA strand to form a double-strand structure(T-Hg^(2+)-T),thus leading to fluorescence reduction.Based on the principle,Hg^(2+)can be quantified based on the fluorescence of Tb^(3+),the limit of detection was 0.0689μmol/L and the linear range was 0.1-6.0μmol/L.Due to the specificity of T-Hg^(2+)-T artificial base pair,the assay could distinguish Hg^(2+)from other metal ions.The recovery rate was ranged in 98.71%-101.34%for detecting mercury pollution in three food samples.The assay is low-cost,separation-free and mix-to-read,thus was a competitive tool for detection of mercury pollution to ensure food safety.
基金support received from the National Natural Science Foundation of China(GrantNos.62204204 and 52175148)Science and Technology Innovation 2030-Major Project(Grant No.2022ZD0208601)+1 种基金Shanghai Sailing Program(Grant No.21YF1451000)Presidential Foundation of CAEP(Grant No.YZJJZQ2022001).
文摘Implanted neural probes can detect weak discharges of neurons in the brain by piercing soft brain tissue,thus as important tools for brain science research,as well as diagnosis and treatment of brain diseases.However,the rigid neural probes,such as Utah arrays,Michigan probes,and metal microfilament electrodes,are mechanically unmatched with brain tissue and are prone to rejection and glial scarring after implantation,which leads to a significant degradation in the signal quality with the implantation time.In recent years,flexible neural electrodes are rapidly developed with less damage to biological tissues,excellent biocompatibility,and mechanical compliance to alleviate scarring.Among them,the mechanical modeling is important for the optimization of the structure and the implantation process.In this review,the theoretical calculation of the flexible neural probes is firstly summarized with the processes of buckling,insertion,and relative interaction with soft brain tissue for flexible probes from outside to inside.Then,the corresponding mechanical simulation methods are organized considering multiple impact factors to realize minimally invasive implantation.Finally,the technical difficulties and future trends of mechanical modeling are discussed for the next-generation flexible neural probes,which is critical to realize low-invasiveness and long-term coexistence in vivo.
文摘Objective The detection of RNA single nucleotide polymorphism(SNP)is of great importance due to their association with protein expression related to various diseases and drug responses.At present,splintR ligase-assisted methods are important approaches for RNA direct detection,but its specificity will be limited when the fidelity of ligases is not ideal.The aim of this study was to create a method to improve the specificity of splintR ligase for RNA detection.Methods In this study,a dualcompetitive-padlock-probe(DCPLP)assay without the need for additional enzymes or reactions is proposed to improve specificity of splintR ligase ligation.To verify the method,we employed dual competitive padlock probe-mediated rolling circle amplification(DCPLP-RCA)to genotype the CYP2C9 gene.Results The specificity was well improved through the competition and strand displacement of dual padlock probe,with an 83.26%reduction in nonspecific signal.By detecting synthetic RNA samples,the method demonstrated a dynamic detection range of 10 pmol/L-1 nmol/L.Furthermore,clinical samples were applied to the method to evaluate its performance,and the genotyping results were consistent with those obtained using the qPCR method.Conclusion This study has successfully established a highly specific direct RNA SNP detection method,and provided a novel avenue for accurate identification of various types of RNAs.
文摘The integrity of the chromosomes for two WIL2-derived lymphoblastoid cell lines (TK6 and WTK1) in the presence and absence of ionizing radiation was analyzed by Multiplex Ligation-Dependent Probe Amplification (MLPA). The TK6 cell line has the native p53 tumor-suppressor gene, whereas WTK1 cells contain a p53 mutation. Each cell line was isolated pre- and post-irradiation (2 and 3 Gy) and analyzed by MLPA. The impact of irradiation on these two cell lines was investigated using probes that target specific regions on chromosomes associated with subtelomeric regions. Results indicate that WTK1 and TK6 are impacted differently after irradiation, and that each cell line presents its own unique MLPA profile. The most notable differences are the appearance of a number of probes in the post-irradiated MLPA profile that are not present in the controls, and two unique probe signals only seen in WTK1 cells. These results build on our previous studies that indicate how different human cell lines can be affected by radiation in significantly different ways depending on the presence or absence of wild type p53.
基金supported by National Natural Science Foundation of China(No.22278308,22109114 and 22102099)。
文摘Lithium hexafluorophosphate(LiPF_(6)),the most commonly used lithium battery electrolyte salt,is vulnerable to heat and humidity.Quantitative and qualitative determination the variation of LiPF_(6)have always relied on advanced equipment.Herein,we develop a fast,convenient,high-selective fluorescence detection method based on metal-organic cages(MOC),whose emission is enhanced by nearly 20 times in the presence of LiPF_(6)with good stability and photobleaching resistance.The fluorescent probe can also detect moisture in battery electrolyte.We propose and verify that the luminescence enhancement is due to the presence of hydrogen bond-induced enhanced emission effect in cages.Fluorescent excitation-emission matrix spectra and variable-temperature nuclear magnetic resonance spectroscopy are employed to clarify the role of hydrogen bonds in guest-loaded cages.Density functional theory(DFT)calculation is applied to simulate the structure of host-guest complexes and estimate the adsorption energy involved in the system.The precisely matched lock-and-key model paves a new way for designing and fabricating novel host structures,enabling specific recognition of other target compounds.
基金Supported by the National Natural Science Foundation of China(No.81870692,No.82070959,No.82271082)the Shanghai Committee of Science and Technology,China(No.20S31905800)Clinical Research Plan of SHDC(No.SHDC2020CR6029).
文摘AIM:To directly quantify peroxynitrite(ONOO-)using a highly sensitive fluorescence resonance energy transfer probe RN-NA,investigate the association between ONOOand primary open angle glaucoma(POAG),and clarify whether RN-NA could be used as a potential tool for POAG diagnosis.METHODS:Plasma and aqueous humor(AH)samples were collected from POAG patients(n=100,age:59.70±6.87y)and age-related cataract(ARC)patients(n=100,age:61.15±4.60y)admitted to our hospital.Next,RN-NA was used to detect ONOO-in plasma and AH samples,and the relationship between ONOO-level and POAG was analyzed using binary logistic regression.Besides,Pearson correlation analysis was applied to characterize the correlation of the levels of ONOO-with the patients’age,intraocular pressure(IOP),and mean deviation of visual field testing.The ONOO-scavenger MnTMPyP was employed to treat the 3-morpholinosyndnomine(SIN-1)-induced ocular hypertension in mice(n=7,6-8wk).Finally,the IOP and ONOO-in both eyes were measured 30min after the last drug treatment.RESULTS:ONOO-levels of AH and plasma were significantly higher in the POAG group than in the ARC group(P<0.01).Additionally,ONOO-levels were closely correlated with POAG in a binary logistic regression analysis[odds ratio(OR)=1.008,95%confidence interval(CI):1.002-1.013,P<0.01 for AH;OR=1.004,95%CI:1.002-1.006,P<0.001 for plasma].Pearson correlation analysis showed that ONOO-levels in AH or plasma were positively associated with visual field defects(R=0.51,P<0.01 for AH;R=0.45,P<0.001 for plasma),and ONOO-levels in plasma and AH were correlated in the POAG group(R=0.69,P<0.001).However,administering MnTMPyP to mouse eyes reversed the elevated IOP caused by SIN-1(P<0.05).CONCLUSION:ONOO-levels in AH and plasma,detected by RN-NA,are significantly related to POAG and positively correlated with visual field defects in POAG patients.Hence,ONOO-is a potential biomarker of POAG,especially advanced POAG.Besides,anti-nitration compounds may be novel ocular hypotensive agents based on the animal study.
基金supported by Bhabha Atomic Research Centre, Department of Atomic Energy, Government of IndiaDepartment of Atomic Energy, Government of India for financial assistance under DAE Doctoral Fellowship Scheme-2018。
文摘Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources.
基金the financial support provided by ANR(Project ANR-22-PEHY-0007)DGA(French Direction Générale des Armées,2018600045)Région Nouvelle Aquitaine(agreement 2018–1R10126).
文摘The long-period-stacking-ordered(LPSO)structure affects the mechanical,corrosion and hydrolysis properties of Mg alloys.The current work employs high angle annular dark field-scanning transmission electron microscopy(HAADF-STEM)and atom probe tomography(APT)to investigate the structural and local chemical information of LPSO phases formed in Mg-Ni-Y/Sm ternary alloys after extended isothermal annealing.Depending on the alloying elements and their concentrations,Mg-Ni-Y/Sm develops a two-phase LPSO+α-Mg structure in which the LPSO phase contains defects,hybrid LPSO structure,and Mg insertions.HAADF-STEM and APT indicate non-stoichiometric LPSO with incomplete Ni_(6)(Y/Sm)_(8) clusters.In addition,the APT quantitatively determines the local composition of LPSO and confirms the presence of Ni within the Mg bonding layers.These results provide insight into a better understanding of the structure and hydrolysis properties of LPSO-Mg alloys.
基金the National Natural Science Foundation of China(No.62173049)the Open Fund of the Hubei Key Laboratory of Oil and Gas Drilling and Production Engineering(Yangtze University),YQZC202309.
文摘Conventional conductivity methods for measuring the void fraction in gas-liquid multiphase systems are typically affected by accuracy problems due to the presence of fluid flow and salinity.This study presents a novel approach for determining the void fraction based on a reciprocating dynamic conductivity probe used to measure the liquid film thickness under forced annular-flow conditions.The measurement system comprises a cyclone,a conductivity probe,a probe reciprocating device,and a data acquisition and processing system.This method ensures that the flow pattern is adjusted to a forced annular flow,thereby minimizing the influence of complex and variable gas-liquid flow patterns on the measurement results;Moreover,it determines the liquid film thickness solely according to circuit connectivity rather than specific conductivity values,thereby mitigating the impact of salinity.The reliability of the measurement system is demonstrated through laboratory experiments.The experimental results indicate that,in a range of gas phase superficial velocities 5–20 m/s and liquid phase superficial velocities 0.079–0.48 m/s,the maximum measurement deviation for the void fraction is 4.23%.
基金BJB thanks the Canada Chairs program for a Research Chair in MRI of Materials[950e230894]an NSERC Discovery Grant[2015-6122]GRG thanks NSERC for a Discovery Grant[RGPIN-2017-06095].
文摘An exploratory multinuclear magnetic resonance(MR)and magnetic resonance imaging(MRI)study was performed on lithium-ion battery cells with ^(7)Li,^(19)F,and ^(1)H measurements.A variable field superconducting magnet with a fixed frequency parallel-plate radiofrequency(RF)probe was employed in the study.The magnetic field was changed to set the resonance frequency of each nucleus to the fixed RF probe frequency of 33.7 MHz.Two cartridge-like lithium-ion cells,with graphite anodes and LiNi_(0.5)Mn_(0.3)Co_(0.2)O_(2)(NMC)cathodes,were interrogated.One cell was pristine,and one was charged to a cell voltage of 4.2 V.The results presented demonstrate the great potential of the variable field magnet approach in multinuclear measurement of lithium-ion batteries.These methods open the door for developing faster and simpler methods for detecting,quantifying,and interpreting MR and MRI data from lithium-ion and other batteries.
基金The study was approved by the Stanford University IRB:53329.
文摘BACKGROUND The functional lumen imaging probe(FLIP)is a Food and Drug Administration approved tool to aid the diagnosis and management of esophageal disorders.However,widespread adoption of FLIP remains limited and its utility in highvolume practices remains unclear.AIM To analyze large sample data on clinical use of FLIP and provide insight on several technical aspects when performing FLIP.METHODS We conducted a retrospective comparative and descriptive analysis of FLIP procedures performed by a single provider at an academic medical center.There was a total of 398 FLIP procedures identified.Patient medical records were reviewed and data regarding demographics and procedural details were collected.Statistical tests,including chi-squared,t-test,and multivariable logistic and linear regression,were performed.RESULTS There was an increase in FLIP cases with each successive time period of 13 months(n=68,146,184,respectively)with notable rises specifically for indications of dysphagia and gastroesophageal reflux disease.There was a shift toward use of the longer FLIP balloon catheter for diagnostic purposes(overall 70.4%vs 29.6%,P<0.01).Many cases(42.8%)were performed in conjunction with other diagnostics/interventions,such as dilation and wireless pH probe placement.Procedures were nearly equally performed with anesthesia vs moderate sedation(51.4%anesthesia),with no major complications.Patients who had anesthesia were less likely to have recurrent antegrade contractions[odds ratio(OR)=0.4,95%CI:0.3-0.8]and were also more likely to have absent contractility(OR=2.4,95%CI:1.3-CONCLUSION FLIP cases have increased in our practice with expanding indications for its use.Given limited normative data,providers should be aware of several potential technical issues,including the possible impact of sedation choice when assessing esophageal motility patterns.