期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Comparison of the hygrothermal performance of two light-framed timber structure buildings under different operation modes
1
作者 Wanqing XU Yucong XUE +2 位作者 Jiang LU Yifan FAN Xiaoyu LUO 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2024年第1期18-35,共18页
Light-framed timber structure(LTS)buildings have been highly valued in recent years due to their low-carbon characteristics.However,the applicability of the building envelope is closely related to indoor and outdoor c... Light-framed timber structure(LTS)buildings have been highly valued in recent years due to their low-carbon characteristics.However,the applicability of the building envelope is closely related to indoor and outdoor conditions.The hot summer and cold winter(HSCW)climate zone in China has high humidity and great temperature variation throughout the year,resulting in distinct outdoor environments in different seasons.The indoor environment is greatly affected by energy-consumption patterns and window-opening habits,which largely depend upon the regulation operations of occupants.All these interrelated factors lead to extremely complex boundary conditions on each side of the building envelope.Whether the structures of LTS buildings are applicable in this climate zone,therefore,needs to be carefully considered.In this study,two LTS buildings with different envelopes were established in Haining,China,situated in the HSCW climate zone,and selected as the study objects.Different operation modes were adopted to create a variety of indoor environments.Under each condition,the processes of heat and moisture transfer within the building envelopes and the indoor environment were monitored and compared.The comparison indicated that the building envelope with high moisture storage and insulation ability maintained a relatively stable indoor environment,especially when the environment changed abruptly.Conversely,if the outdoor environment was equable(e.g.,relative humidity within the range of 30%–60%)or intermittent energy consumption modes were adopted,the building envelope with a low thermal inertia index and weak moisture-buffering ability performed better because it enabled a faster response of the indoor environment to air conditioning.Moreover,a high risk of moisture accumulation between the thermal insulation layer and other materials with a large water vapour transfer resistance factor was also identified,suggesting a higher requirement for the vapour insulation of the envelopes of LTS buildings. 展开更多
关键词 Light-framed timber structure(LTS)buildings In-situ experiment Typical operation mode Indoor environment Heatand moisture transfer
原文传递
Deflection test and modal analysis of lightweight timber floors 被引量:2
2
作者 Xinyue Zhao Yujie Huang +3 位作者 Haiyan Fu Yunlu Wang Zheng Wang Usama Sayed 《Journal of Bioresources and Bioproducts》 EI 2021年第3期266-278,共13页
In order to meet the objective requirements of the safety and comfort of the modern lightweight timber floors,and strengthen the research on the coupling performance of the lightweight timber floors vibration characte... In order to meet the objective requirements of the safety and comfort of the modern lightweight timber floors,and strengthen the research on the coupling performance of the lightweight timber floors vibration characteristics and the building comfort,this article discusses the floor of a two-story prefabricated lightweight timber building demonstration house.In this paper,the floor structure of a two-story light-weight wooden house has been carried out on structural calculation modal and experimental modal,static uniform load and concentrated load deflection value testing.The evaluation of the deflection value of the floor structure,the mode shape,the coupling of the fundamental frequency mode parameters,and the vibration comfort were also studied.The results show that the fundamental frequency simulation value,one-way modal test value and two-way modal test value of the floor structure all meet the requirements of BS-6472(BS6472-1:2008).That is,the floor structure is not lower than 8 Hz design requirements,and meets the frequency of BS-6472(BS6472-1:2008).The weighted root mean square acceleration is lower than the requirement of 0.45 m/s^(2);the first three natural frequencies of the floor structure calculated by the finite element simulation are 16.413,31.847 and 48.921 Hz,and the fundamental frequency mode is the bending vibration in the length and width directions.The second order is the bending mode in the length direction,and the third order is the bending mode in the width direction.The fundamental frequency of the two-way modal test of the floor structure is the first-order bending mode in the X direction;and the second-order natural frequency is the second-order bending vibration shape in the X direction.when the uniform load is mainly the weight of floor own,the simulated maximum deflection value is 1.0658 mm;the simulation is performed according to the standard value of 0.566 kN/m for the uniform load of the floor design,and the simulation is the largest.The maximum deflection value of the simulated floor is 1.47383 mm at its midpoint,which meets the requirements of National Building Code of Canada-2015(NBCC).The maximum deflection limit of the light wood structure floor system is lower than 3 m and the maximum deflection limit is 2 mm;the six deflection value test lines simulated under a concentrated load of 1 kN all present a parabolic distribution and are symmetrical.The above results has engineering application value for promoting the research on the vibration characteristics of the fabricated lightweight timber floors structure and its optimization design. 展开更多
关键词 Lightweight timber structure building Floor structure Static load test Test mode Calculation mode building comfort
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部