Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water ...Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water in the outer sea. However, owing to the temporal and spatial complexity of the coastal flushing process, existing methods for determining flushing time may not be generally applicable. In this paper, a systematic method for determining the flushing time in FCZs is presented, in which bathymetry, runoff, tidal range and stratification are properly accounted for. We determine the flushing time via numerical tracer experiments, using robust 3D hydrodynamic and mass transport models. For FCZs located in sheltered and land-locked tidal inlets, the system boundary can be naturally defined at the connection with the open sea. For FCZs located in open'waters, hydrodynamic tracking is first used to assess the extent of tidal excursion and thus delimit the initial boundary between clean water and polluted water. This general method is applied to all designated marine FCZs in Hong Kong for both the dry and wet seasons, including 20 sheltered FCZs (in semi-enclosed waters of Tolo Harbour, Mirs Bay, and Port Shelter) and 6 FCZs in open waters. Our results show that flushing time is the longest in inner Port Shelter (about 40 days in dry season), and the shortest for the FCZs in open waters (less than one week in dry season). In addition, the flushing time in dry season is commonly longer than that in wet season: 20%~40% for most well-sheltered FCZs; 2.6-4 times for the others. Our results indicate a positive correlation between the flushing time and distance to open boundary, supporting the view that the flushing time of a FCZ is closely related to its location. This study provides a solid basis for mariculture management such as the determination of carrying capacity of FCZs.展开更多
In this paper, adaptive variable structure neural control is presented for a class of uncertain multi-input multi-output (MIMO) nonlinear systems with state time-varying delays and unknown nonlinear dead-zones. The ...In this paper, adaptive variable structure neural control is presented for a class of uncertain multi-input multi-output (MIMO) nonlinear systems with state time-varying delays and unknown nonlinear dead-zones. The unknown time-varying delay uncer- tainties are compensated for using appropriate Lyapunov-Krasovskii functionals in the design. The approach removes the assumption of linear function outside the deadband without necessarily constructing a dead-zone inverse as an added contribution. By utilizing the integral-type Lyapunov function and introducing an adaptive compensation term for the upper bound of the residual and optimal approximation error as well as the dead-zone disturbance, the closed-loop control system is proved to be semi-globally uniformly ultimately bounded. In addition, a modified adaptive control algorithm is given in order to avoid the high-frequency chattering phenomenon. Simulation results demonstrate the effectiveness of the approach.展开更多
By computing and classifying the data of gully offset obtained from field surveys along the Tianjingshan fault zone and estimating the ages of three types of gullies,the strike-slip rates along the fault zone are disc...By computing and classifying the data of gully offset obtained from field surveys along the Tianjingshan fault zone and estimating the ages of three types of gullies,the strike-slip rates along the fault zone are discussed in different time intervals and fault segments.The results suggest that the intensity of activity along the fault zone is not strong,but the differences between different time intervals and fault segments since the late Pleistocene have been obvious.The average rates range from 0.23 mm/a to 1.62 mm/a.The largest average rate is 1.40 mm/a,which occurred in the early and middle of late Pleistocene along the western segment of the fault zone.Since the late stage of the late Pleistocene,the center of faulting activity of the fault zone has shifted to the middle segment,and the average slip rates range have changed from 1.30 mm/a to 1.63 mm/a.展开更多
This study compares numerical models with analytical solutions in computing travel times and radius of protection zones for a pumping well located in an unconfined aquifer with uniform recharge and in a semi-confined ...This study compares numerical models with analytical solutions in computing travel times and radius of protection zones for a pumping well located in an unconfined aquifer with uniform recharge and in a semi-confined aquifer. Numerical models were capable of delineating protection zones using particle tracking method in both cases. However, protection zones defined by travel time criterion can only protect small percent of source water to the well; large percent of source water is not protected which may pose a risk of pollution of source water to the well. The case study of Leggeloo well field in the Netherlands indicates that although a well field protection area was enforced in 1980 s, elevated nitrate concentration has been monitored in the abstracted water since 1990 s. The analysis of protection areas shows that the current protection area only protects 37.4% of recharge water to the well field. A large protection area must be adopted in order to safeguard the sustainable water supply for the local community.展开更多
At present,textbooks based on core literacy have become the inevitable demands of China’s curriculum reform,and the literacy of textbook goal construction is the key to the implementation of core literacy requirement...At present,textbooks based on core literacy have become the inevitable demands of China’s curriculum reform,and the literacy of textbook goal construction is the key to the implementation of core literacy requirements,which is a huge challenge for textbook compilers.In this paper,we use the visual metrology of the CiteSpace knowledge graph to analyze Chinese mathematics textbooks(1999-2024),hoping to guide the future direction of Chinese mathematics textbook research.展开更多
基金supported by the Hong Kong Jockey Club Charities Trust (Project Waterman)in part by a grant from the University Grants Committee of the Hong Kong Special Administrative Region (HKSAR),China (Project No. AoE/P-04/04) to the Area of Excellence in Marine Environment Research and Innovative Technology (MERIT)+1 种基金The support from the National Science Fund for Distinguished Young Scholars (Grant No. 50925932)the National Natural Science Foundation of China (Grant No.41001348)
文摘Accurate determination of flushing time is crucial for maintaining sustainable production in fish culture zones (FCZs), as it represents the physical self-purification capability via tidal exchange with clean water in the outer sea. However, owing to the temporal and spatial complexity of the coastal flushing process, existing methods for determining flushing time may not be generally applicable. In this paper, a systematic method for determining the flushing time in FCZs is presented, in which bathymetry, runoff, tidal range and stratification are properly accounted for. We determine the flushing time via numerical tracer experiments, using robust 3D hydrodynamic and mass transport models. For FCZs located in sheltered and land-locked tidal inlets, the system boundary can be naturally defined at the connection with the open sea. For FCZs located in open'waters, hydrodynamic tracking is first used to assess the extent of tidal excursion and thus delimit the initial boundary between clean water and polluted water. This general method is applied to all designated marine FCZs in Hong Kong for both the dry and wet seasons, including 20 sheltered FCZs (in semi-enclosed waters of Tolo Harbour, Mirs Bay, and Port Shelter) and 6 FCZs in open waters. Our results show that flushing time is the longest in inner Port Shelter (about 40 days in dry season), and the shortest for the FCZs in open waters (less than one week in dry season). In addition, the flushing time in dry season is commonly longer than that in wet season: 20%~40% for most well-sheltered FCZs; 2.6-4 times for the others. Our results indicate a positive correlation between the flushing time and distance to open boundary, supporting the view that the flushing time of a FCZ is closely related to its location. This study provides a solid basis for mariculture management such as the determination of carrying capacity of FCZs.
基金supported by National Natural Science Foundationof China (No. 60774017 and No. 60874045)
文摘In this paper, adaptive variable structure neural control is presented for a class of uncertain multi-input multi-output (MIMO) nonlinear systems with state time-varying delays and unknown nonlinear dead-zones. The unknown time-varying delay uncer- tainties are compensated for using appropriate Lyapunov-Krasovskii functionals in the design. The approach removes the assumption of linear function outside the deadband without necessarily constructing a dead-zone inverse as an added contribution. By utilizing the integral-type Lyapunov function and introducing an adaptive compensation term for the upper bound of the residual and optimal approximation error as well as the dead-zone disturbance, the closed-loop control system is proved to be semi-globally uniformly ultimately bounded. In addition, a modified adaptive control algorithm is given in order to avoid the high-frequency chattering phenomenon. Simulation results demonstrate the effectiveness of the approach.
基金This project was sponsored by the State Seismological Bureau (85-02-3-3), China
文摘By computing and classifying the data of gully offset obtained from field surveys along the Tianjingshan fault zone and estimating the ages of three types of gullies,the strike-slip rates along the fault zone are discussed in different time intervals and fault segments.The results suggest that the intensity of activity along the fault zone is not strong,but the differences between different time intervals and fault segments since the late Pleistocene have been obvious.The average rates range from 0.23 mm/a to 1.62 mm/a.The largest average rate is 1.40 mm/a,which occurred in the early and middle of late Pleistocene along the western segment of the fault zone.Since the late stage of the late Pleistocene,the center of faulting activity of the fault zone has shifted to the middle segment,and the average slip rates range have changed from 1.30 mm/a to 1.63 mm/a.
文摘This study compares numerical models with analytical solutions in computing travel times and radius of protection zones for a pumping well located in an unconfined aquifer with uniform recharge and in a semi-confined aquifer. Numerical models were capable of delineating protection zones using particle tracking method in both cases. However, protection zones defined by travel time criterion can only protect small percent of source water to the well; large percent of source water is not protected which may pose a risk of pollution of source water to the well. The case study of Leggeloo well field in the Netherlands indicates that although a well field protection area was enforced in 1980 s, elevated nitrate concentration has been monitored in the abstracted water since 1990 s. The analysis of protection areas shows that the current protection area only protects 37.4% of recharge water to the well field. A large protection area must be adopted in order to safeguard the sustainable water supply for the local community.
文摘At present,textbooks based on core literacy have become the inevitable demands of China’s curriculum reform,and the literacy of textbook goal construction is the key to the implementation of core literacy requirements,which is a huge challenge for textbook compilers.In this paper,we use the visual metrology of the CiteSpace knowledge graph to analyze Chinese mathematics textbooks(1999-2024),hoping to guide the future direction of Chinese mathematics textbook research.