Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocesso...Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.展开更多
Stable and fully developed gas flow field is crucial for realizing accurate measurement of gas ultrasonicflow meter. To reduce the flow field distortion, a flow conditioner is usually used. However, the traditionalmon...Stable and fully developed gas flow field is crucial for realizing accurate measurement of gas ultrasonicflow meter. To reduce the flow field distortion, a flow conditioner is usually used. However, the traditionalmonotype flow conditioner can only improve the flow field distribution partly. The measurement accuracy of thetransit time ultrasonic flow meter is still affected because of its serious flow field distortion in the complex pipelineconditions. In this paper, to further improve the flow field distribution, a combined conditioner is investigated.The combined flow conditioner is composed of fan-shaped section, turbulent mixing cavity, and honeycomb-shapedsection. The effects of fan blade angle and cavity length on the flow field of the DN50 flow meter are studied usingcomputational fluid dynamics (CFD) simulation. Simulation results indicate that compared with the monotypeconditioner, the combined conditioner has better performance on effectively reducing the swirl and turbulence andproviding more stable and repetitive velocity profiles. Experiments also validate the effectiveness of the combinedconditioner. The flow meter with the combined conditioner has better repeatability of less than 0.2%, which isbetter than those of the monotype conditioners under the same conditions. This work is very useful for accuratemeasurement of gas ultrasonic flow meter, especially for the complex pipeline conditions.展开更多
文摘Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.
文摘Stable and fully developed gas flow field is crucial for realizing accurate measurement of gas ultrasonicflow meter. To reduce the flow field distortion, a flow conditioner is usually used. However, the traditionalmonotype flow conditioner can only improve the flow field distribution partly. The measurement accuracy of thetransit time ultrasonic flow meter is still affected because of its serious flow field distortion in the complex pipelineconditions. In this paper, to further improve the flow field distribution, a combined conditioner is investigated.The combined flow conditioner is composed of fan-shaped section, turbulent mixing cavity, and honeycomb-shapedsection. The effects of fan blade angle and cavity length on the flow field of the DN50 flow meter are studied usingcomputational fluid dynamics (CFD) simulation. Simulation results indicate that compared with the monotypeconditioner, the combined conditioner has better performance on effectively reducing the swirl and turbulence andproviding more stable and repetitive velocity profiles. Experiments also validate the effectiveness of the combinedconditioner. The flow meter with the combined conditioner has better repeatability of less than 0.2%, which isbetter than those of the monotype conditioners under the same conditions. This work is very useful for accuratemeasurement of gas ultrasonic flow meter, especially for the complex pipeline conditions.