期刊文献+
共找到141篇文章
< 1 2 8 >
每页显示 20 50 100
Ultrafast carrier dynamics in GeSn thin film based on time-resolved terahertz spectroscopy
1
作者 黄盼盼 张有禄 +3 位作者 胡凯 齐静波 张岱南 程亮 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期164-169,共6页
We measure the time-resolved terahertz spectroscopy of GeSn thin film and studied the ultrafast dynamics of its photo-generated carriers.The experimental results show that there are photo-generated carriers in GeSn un... We measure the time-resolved terahertz spectroscopy of GeSn thin film and studied the ultrafast dynamics of its photo-generated carriers.The experimental results show that there are photo-generated carriers in GeSn under femtosecond laser excitation at 2500 nm,and its pump-induced photoconductivity can be explained by the Drude–Smith model.The carrier recombination process is mainly dominated by defect-assisted Auger processes and defect capture.The firstand second-order recombination rates are obtained by the rate equation fitting,which are(2.6±1.1)×10^(-2)ps^(-1)and(6.6±1.8)×10^(-19)cm^(3)·ps^(-1),respectively.Meanwhile,we also obtain the diffusion length of photo-generated carriers in GeSn,which is about 0.4μm,and it changes with the pump delay time.These results are important for the GeSn-based infrared optoelectronic devices,and demonstrate that Ge Sn materials can be applied to high-speed optoelectronic detectors and other applications. 展开更多
关键词 GeSn thin film time-resolved THz spectroscopy ultrafast dynamics carrier recombination
下载PDF
Time-resolved K-shell x-ray spectra of nanosecond laser-produced titanium tracer in gold plasmas
2
作者 何贞岑 张继彦 +2 位作者 杨家敏 闫冰 胡智民 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期51-55,共5页
A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By co... A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By comparing the simulated spectra obtained by using the FLYCHK code with the measured titanium spectra, the temporal plasma states, i.e.,the electron temperatures and densities, are deduced. To evaluate the feasibility of using the method for the characterization of Au plasma states, the deduced plasma states from the measured titanium spectra are compared with the Multi-1D hydrodynamic simulations of laser-produced Au plasmas. By comparing the measured and simulated results, an overall agreement for the electron temperatures is found, whereas there are deviations in the electron densities. The experiment–theory discrepancy may suggest that the plasma state could not be well reproduced by the Multi-1D hydrodynamic simulation, in which the radial gradient is not taken into account. Further investigations on the spectral characterization and hydrodynamic simulations of the plasma states are needed. All the measured and FLYCHK simulated spectra are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.57760/sciencedb.j00113.00032. 展开更多
关键词 nanosecond laser irradiation time-resolved x-ray spectra characterization of plasma states Multi-1D hydrodynamic simulations
下载PDF
Time-resolved fluoroimmunoassay of zearalenone in cereals with a europium chelate as label 被引量:5
3
作者 马智鸿 黄飚 +3 位作者 张珏 张艺 朱岚 屠蔷 《Journal of Rare Earths》 SCIE EI CAS CSCD 2009年第6期1088-1091,共4页
A competitive indirect time-resolved fluoroimmunoassay(TRFIA) was developed for detection of zearalenone(ZEN) in cereals,in which ZEN conjugated to bovine serum albumin(BSA) is used as solid-phase antigen.A competitiv... A competitive indirect time-resolved fluoroimmunoassay(TRFIA) was developed for detection of zearalenone(ZEN) in cereals,in which ZEN conjugated to bovine serum albumin(BSA) is used as solid-phase antigen.A competitive indirect TRFIA was conducted by simultaneously incubating ZEN in standard or extracted samples with anti-ZEN monoclonal antibody over ZEN-BSA coated plates,and then determining the bound ZEN monoclonal antibody with goat anti-mouse europium conjugate.Samples were extracted with methanol/water... 展开更多
关键词 time-resolved fluoroimmunoassay ZEARALENONE EUROPIUM rare earths food safety
下载PDF
Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration 被引量:5
4
作者 Han-Chun Yao Min Sun +2 位作者 Xiao-Feng Yang Zhen-Zhong Zhang Hua Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期32-38,共7页
The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CP... The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation. 展开更多
关键词 time-resolved chemiluminescence artificial neural network CAPTOPRIL HYDROCHLOROTHIAZIDE
下载PDF
Study on local topology model of low/high streak structures in wall-bounded turbulence by tomographic time-resolved particle image velocimetry 被引量:6
5
作者 Haiping TIAN Nan JIANG +1 位作者 Yongxiang HUANG Shaoqiong YANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2015年第9期1121-1130,共10页
The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry... The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak. 展开更多
关键词 wall turbulence quadrupole topological structure hairpin vortex low/highspeed streak tomographic time-resolved particle image velocimetry (TRPIV) system
下载PDF
Simultaneous measurements of global vibrational spectra and dephasing times of molecular vibrational modes by broadband time-resolved coherent anti-Stokes Raman scattering spectrography 被引量:2
6
作者 尹君 于凌尧 +3 位作者 刘星 万辉 林子扬 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期385-391,共7页
In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of variou... In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of various spectral components of SC in an enough bandwidth. By numerical simulations, the optimal experimental conditions for improving the SC are obtained. The broadband time-resolved CARS spectrography based on the SC with required temporal and spectral distributions is realised. The global molecular vibrational spectrum with well suppressed nonresonant background noise can be obtained in a single measurement. At the same time, the measurements of dephasing times of various molecular vibrational modes can be conveniently achieved from intensities of a sequence of time-resolved CARS signals. It will be more helpful to provide a complete picture of molecular vibrations, and to exhibit a potential to understand not only both the solvent dynamics and the solute-solvent interactions, but also the mechanisms of chemical reactions in the fields of biology, chemistry and material science. 展开更多
关键词 coherent anti-Stokes Raman scattering photonic crystal fibre SUPERCONTINUUM molecular vibrational spectrum dephasing time time-resolved measurement
下载PDF
Time-resolved shadowgraphs and morphology analyses of aluminum ablation with multiple femtosecond laser pulses 被引量:2
7
作者 吴泽华 张楠 +3 位作者 朱晓农 安力群 王刚志 谭明 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期536-542,共7页
Aluminum ablation by multiple femtosecond laser pulses is investigated via time-resolved shadowgraphs and scanning electron microscope (SEM) images of the ablation spot. The spatial distribution of the ejected mater... Aluminum ablation by multiple femtosecond laser pulses is investigated via time-resolved shadowgraphs and scanning electron microscope (SEM) images of the ablation spot. The spatial distribution of the ejected material and the radius of the shock wave generated during the ablation are found to vary with the increase in the number of pulses. In the initial two pulses, nearly concentric and semicircular stripes within the shock wave front are observed, unlike in subsequent pulses. Ablation by multiple femtosecond pulses exhibits different characteristics compared with the case induced by single femtosecond pulse because of the changes to the aluminum target surface induced by the preceding pulses. 展开更多
关键词 femtosecond laser ablation ultrafast phenomena time-resolved shadowgraphs morphology analyses
下载PDF
Eu-Chelate Construct Ultrasensitive Time-Resolved Fluoroimmunoassay-Assay of Pepsinogen I 被引量:1
8
作者 黄飚 张祥瑞 +3 位作者 朱岚 刘海燕 蒋叶华 金坚 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期381-384,共4页
Eu-chelate were used to construct a two-site sandwich-type assay for pepsinogen Ⅰ (PGI) with time-resolved fluoroimmunoassay (TRFIA) as a detection technique. On the noncompetitive assay, captured monoclonal anti... Eu-chelate were used to construct a two-site sandwich-type assay for pepsinogen Ⅰ (PGI) with time-resolved fluoroimmunoassay (TRFIA) as a detection technique. On the noncompetitive assay, captured monoclonal antibodies (McAbs) coated on wells were directed against a specific antigenic site on the PGI. Another McAbs, called as labeling McAbs, were prepared with the Eu-chelate of N-(p-isothiocyanatobenzyl)-diethylenetriamine-N, N, N, N-tetraacetic acid and directed against a different antigenic site on the PGI. The fluorescence counts of bound Eu^3+ -McAbs were measured with the auto DELFIA1235 system. The PGI in sera from healthy volunteers were determined by PGI-TRFIA. The within-run and between-run CVs of the PGI-TRFIA were 1.9% and 4.7%, respectively, and the recovery rate was 102.65%. The assay had a detection limit of 0.05 μg· L^-1. The PGI-TRFIA provided a linear response from 3.5 to 328 μg· L^-1. The cross-reacting rate with pepsinogen Ⅱ was negligible. The linear correlation of PGI-TRFIA and radioimmunassay measurements resulted in a correlation coefficient of 0.977. The means of healthy volunteers were 154 ±43 μg·L^-1 for serum PGI. The availability of a highly sensitive, reliable, and convenient method for quantifying PGI will allow investigations into the possible diagnostic value of this analyte in various clinical conditions, including gastric carcinoma, duodenal ulcer, gastritis and severe atrophic gastritis. 展开更多
关键词 time-resolved fluoroimmunoassay pepsinogen Eu-chelate rare earths
下载PDF
Detection of K in soil using time-resolved laser-induced breakdown spectroscopy based on convolutional neural networks 被引量:1
9
作者 吕程序 王博 +3 位作者 姜训鹏 张俊宁 牛康 苑严伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期108-113,共6页
One of the technical bottlenecks of traditional laser-induced breakdown spectroscopy(LIBS) is the difficulty in quantitative detection caused by the matrix effect. To troubleshoot this problem,this paper investigated ... One of the technical bottlenecks of traditional laser-induced breakdown spectroscopy(LIBS) is the difficulty in quantitative detection caused by the matrix effect. To troubleshoot this problem,this paper investigated a combination of time-resolved LIBS and convolutional neural networks(CNNs) to improve K determination in soil. The time-resolved LIBS contained the information of both wavelength and time dimension. The spectra of wavelength dimension showed the characteristic emission lines of elements, and those of time dimension presented the plasma decay trend. The one-dimensional data of LIBS intensity from the emission line at 766.49 nm were extracted and correlated with the K concentration, showing a poor correlation of R_c^2?=?0.0967, which is caused by the matrix effect of heterogeneous soil. For the wavelength dimension, the two-dimensional data of traditional integrated LIBS were extracted and analyzed by an artificial neural network(ANN), showing R_v^2?=?0.6318 and the root mean square error of validation(RMSEV)?=?0.6234. For the time dimension, the two-dimensional data of time-decay LIBS were extracted and analyzed by ANN, showing R_v^2?=?0.7366 and RMSEV?=?0.7855.These higher determination coefficients reveal that both the non-K emission lines of wavelength dimension and the spectral decay of time dimension could assist in quantitative detection of K.However, due to limited calibration samples, the two-dimensional models presented over-fitting.The three-dimensional data of time-resolved LIBS were analyzed by CNNs, which extracted and integrated the information of both the wavelength and time dimension, showing the R_v^2?=?0.9968 and RMSEV?=?0.0785. CNN analysis of time-resolved LIBS is capable of improving the determination of K in soil. 展开更多
关键词 quantitative DETECTION potassium(K) SOIL time-resolveD LASER-INDUCED BREAKDOWN spectroscopy(LIBS) convolutional neural networks(CNNs)
下载PDF
Time-resolved measurement of atomic emission enhancement by fs-ns dual-pulsed laser-induced breakdown spectroscopy 被引量:1
10
作者 颜立新 张永生 +3 位作者 郑国鑫 刘晶儒 程建平 吕敏 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第10期2271-2274,共4页
Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG ... Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization. 展开更多
关键词 time-resolved measurement atomic emission enhancement dual-pulse LIBS
下载PDF
Coherent coupling between vibrational modes of C-H bonds at different positions studied by femtosecond time-resolved coherent anti-Stokes Raman scattering 被引量:1
11
作者 杜鑫 何兴 +2 位作者 刘玉强 王英惠 杨延强 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第3期248-251,共4页
We performed femtosecond time-resolved coherent anti-Stokes Raman scattering (fs-CARS) measurements on liquid toluene and PVK film. For both samples, we selectively excited the CH stretching vibrational modes and ob... We performed femtosecond time-resolved coherent anti-Stokes Raman scattering (fs-CARS) measurements on liquid toluene and PVK film. For both samples, we selectively excited the CH stretching vibrational modes and observed the expected quantum beat signals. The frequency of the well-defined beats is in good agreement with the energy difference between the two simultaneously excited modes, which demonstrates that a coherent coupling between the vibrational modes of the C H chemical bonds exists at the different positions of the molecules. The dephasing times of the excited modes are obtained simultaneously. 展开更多
关键词 femtosecond time-resolved coherent anti-Stokes Raman scattering coherent coupling quantum beat
下载PDF
Development of time-resolved immunofluorometric assays for the detection of house dust mite-allergic IgE in human sera 被引量:1
12
作者 Ratchanoo Phiphatchaipaisarn Jundee Rabablert +4 位作者 Kornkarn Bramarapravati Duangthep Thongdee Nares Wongpitoon Worawan Durongpisitkul Nat Malainual 《Health》 2010年第11期1280-1286,共7页
Dermatophagoides farinae and D. pteronyssinus are the prevalent house dust mites (HDM) in tropical countries and are associated with allergic diseases. This investigation developed a time- resolved immunofluorometric ... Dermatophagoides farinae and D. pteronyssinus are the prevalent house dust mites (HDM) in tropical countries and are associated with allergic diseases. This investigation developed a time- resolved immunofluorometric assay (TR-IFMA) for the first time to detect specific IgE antibody in patients with skin prick test positive to HDM but no detectable IgE by other means. Levels of IgE to natural and recombinant HDM allergens were measured by TR-IFMA in 50 HDM-allergic patients and 19 healthy participants compared to sandwich enzyme-linked immunosorbent assay (ELISA). A recombinant allergen, rDerf2, showed a 14 kDa band corresponding to broad range proteins of natural HDM.TR-IFMA showed sensitivity lower than 0.35 kUA/l. TR-IFMA employing three HDM antigens showed good correlations with sandwich ELISA at R2 0.93-0.96. TR-IFMA detected HDM IgE in 62, 62, 25 percent of allergic patient serum sample compared to 28, 32, and 22 percent detected by ELISA result using three HDM allergen. TR-IFMA also detected 26.3, 31.6, and 5.3 percent positive samples from 19 healthy participants while ELISA showed 0, 5.3, and 0 percents IgE positive samples. The use of rDerf2 as an HDM allergen for the assay was verified with no statistically different from other HDM allergens. TR-IFMA showed lower detection limit than ELISA and yielded higher sensitivity for serum of people with allergic symptoms with no detectable HDM IgE. It is anticipated that TR-IFMA for HDM-specific IgE detection will play an important role in future diagnosis of HDM allergy in clinical laboratories and for different research purposes. 展开更多
关键词 House Dust MITES time-resolveD Immunofluorometric Assay ALLERGY IGE
下载PDF
Probing Ultrafast Dissociation Dynamics of Chloroiodomethane in the B Band by Time-Resolved Mass Spectrometry 被引量:1
13
作者 刘玉柱 龙金友 +2 位作者 徐林华 张翔云 张冰 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期21-24,共4页
Ultrafast dissociation dynamics of chloroiodomethane (CH2ICl) in the B band is studied by femtosecond time- resolved time-of-flight (TOF) mass spectrometry. Time-resolved TOF mass signal of parent ion (CH2ICl+)... Ultrafast dissociation dynamics of chloroiodomethane (CH2ICl) in the B band is studied by femtosecond time- resolved time-of-flight (TOF) mass spectrometry. Time-resolved TOF mass signal of parent ion (CH2ICl+) and main daughter ion (CH2Cl+) are obtained. The curve for the transient signal of CH2ICl+ is simple and can be well fitted by an exponential decay convoluted with a Gaussian function. The decay constant determined to be less than 35 fs reflects the lifetime of the B band. Significant substituent effects on photodissociation dynamics of CH2IC1 compared with CH3I are discussed. The dissociation time from the parent ion CH2IC1+ to the daughter ion CH2Cl+ is determined in the experiment. The optimized geometry of the ionic state of CH2ICl and the ionization energy are calculated for further analysis of the measurements. In addition, compared with the parent ion, a new decay component with time constant of -596 fs is observed for CH2Cl+, and reasonable mechanisms are proposed for the explanation. 展开更多
关键词 Probing Ultrafast Dissociation Dynamics of Chloroiodomethane in the B Band by time-resolved Mass Spectrometry ICI
下载PDF
Time-Resolved Transmission Measurements of Warm Dense Iron Plasma
14
作者 青波 赵阳 +6 位作者 韦敏习 黎航 熊刚 吕敏 胡智民 张继彦 杨家敏 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第3期64-67,共4页
Transmission measurements of warm dense iron plasma are reported over the photon energy range of 400-1200 e V, including the strong 2p-3d structures. One-dimensional hydrodynamic simulation is performed to estimate th... Transmission measurements of warm dense iron plasma are reported over the photon energy range of 400-1200 e V, including the strong 2p-3d structures. One-dimensional hydrodynamic simulation is performed to estimate the plasma conditions: temperatures of several eV and densities of about O. 1 g/cm3. By using the simulated tempera- ture and density, the calculations of the transmission spectra are performed and compared with the time-resolved experimental results. 展开更多
关键词 of as is in time-resolved Transmission Measurements of Warm Dense Iron Plasma were
下载PDF
Time-resolved ESI-MS Investigation on Reduction and Alkylation in Unfolding Process of Lysozyme
15
作者 SONG Hao-wei XU Chong-feng +2 位作者 FU Yun-lin YANG Peng-yuan WANG Hong-hai 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期387-393,共7页
The kinetic procedure of the unfolding of lysozyme induced by the reduction of disulfide was monitored by the time-resolved ESI-MS with a sheath liquid assistant electrospray interface. It was found that the reduction... The kinetic procedure of the unfolding of lysozyme induced by the reduction of disulfide was monitored by the time-resolved ESI-MS with a sheath liquid assistant electrospray interface. It was found that the reduction process for the eight disulfides had a less difference in the reaction time after denatured treatment. In addition, the alkylation of the reduced free thiols was much slower than the reduction procedure. An artifact peak produced by the CID fragmentation in the mass spectra was identified and the possible mechanism of the Hofmann elimination reaction was proposed. 展开更多
关键词 Keywords Unfolding LYSOZYME Reduction and alkylation time-resolved ESI-MS
下载PDF
Determining the sign of g factor via time-resolved Kerr rotation spectroscopy with a rotatable magnetic field
16
作者 谷晓芳 钱轩 +2 位作者 姬扬 陈林 赵建华 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期415-418,共4页
Time-resolved Kerr rotation spectroscopy is used to determine the sign of the g factor of carriers in a semiconductor material, with the help of a rotatable magnetic field in the plane of the sample. The spin precessi... Time-resolved Kerr rotation spectroscopy is used to determine the sign of the g factor of carriers in a semiconductor material, with the help of a rotatable magnetic field in the plane of the sample. The spin precession signal of carriers at a fixed time delay is measured as a function of the orientation of the magnetic field with a fixed strength B. The signal has a sine-like form and its phase determines the sign of the g factor of carriers. As a natural extension of previous methods to measure the (time-resolved) photoluminescence or time-resolved Kerr rotation signal as a function of the magnetic field strength with a fixed orientation, such a method gives the correct sign of the g factor of electrons in GaAs. Furthermore, the sign of carriers in a (Ga, Mn)As magnetic semiconductor is also found to be negative. 展开更多
关键词 g factor time-resolved Kerr rotation gallium arsenide rotatable magnetic field
下载PDF
Enhancing redshift phenomenon in time-resolved photoluminescence spectra of AlGaN epilayer
17
作者 李维 金鹏 +4 位作者 王维颖 毛德丰 潘旭 王晓亮 王占国 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第7期399-402,共4页
AlGaN epitaxial layer has been studied by means of temperature-dependent time-integrated photoluminescence(PL)and time-resolved photoluminescence(TRPL). An enhancing redshift phenomenon in TRPL spectra with increa... AlGaN epitaxial layer has been studied by means of temperature-dependent time-integrated photoluminescence(PL)and time-resolved photoluminescence(TRPL). An enhancing redshift phenomenon in TRPL spectra with increasing temperature was observed, and the localized excitons behaved like quasi two-dimensional excitons between 6 K and 90 K. We demonstrated that these behaviors are caused by a change in the carrier dynamics with increasing temperature due to the competition of carriers' localization and delocalization in the AlGaN alloy. 展开更多
关键词 ALGAN time-resolved photoluminescence localized excitons
下载PDF
Theoretical and experimental investigations of coherent phonon dynamics in sapphire crystal using femto-second time-resolved coherent anti-Stokes Raman scattering
18
作者 杜鑫 张明福 +4 位作者 何兴 孟庆琨 宋云飞 杨延强 韩杰才 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第12期315-321,共7页
We report on the theoretical and the experimental investigations of the coherent phonon dynamics in sapphire crystal using the femtosecond time-resolved coherent anti-Stokes Raman scattering (fs-CARS) technique. The... We report on the theoretical and the experimental investigations of the coherent phonon dynamics in sapphire crystal using the femtosecond time-resolved coherent anti-Stokes Raman scattering (fs-CARS) technique. The temporal chirped white-light continuum (WLC) is used for the Stokes pulse, therefore we can perform the selective excitation of the phonon modes without using a complicated laser system. The expected quantum beat phenomenon is clearly observed. The theoretical formulas consist very well with the experimental results. The dephasing times of the excited phonon modes, the wavenumber difference, and the phase shift between the simultaneously excited modes are obtained and discussed. This work opens up a way to study directly high-frequency coherent phonon dynamics in bulk crystals on a femtosecond time scale and is especially helpful for understanding the nature of coherent phonons. 展开更多
关键词 coherent phonon femtosecond time-resolved coherent anti-Stokes Raman scattering DEPHASING quantum beat
下载PDF
Time-Resolved Photoluminescence Spectra of Porous Si
19
作者 FEI Hao-sheng HAN Li +1 位作者 CHE Yan-long NIE Rui-juan and LI Tie-jin(Deparrment of Physics and Deparrment of Chemistry ,Jilin University , Changchun , 1 30023 ) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1995年第1期58-63,共6页
he photoluminescence spectra of porous Si have been studied. Its timere-solved luminescence spectra show a red shift of luminescencc peak with increasingdelay time after exciting and a nonexponential decay. Several sp... he photoluminescence spectra of porous Si have been studied. Its timere-solved luminescence spectra show a red shift of luminescencc peak with increasingdelay time after exciting and a nonexponential decay. Several spectral bands withdifferent Gaussian center appear by means of the decomposition of a spetrum. Theresuits of our experiments show quantum confined characters in porous Si, and wespeculate that the short wavelength band at 465 nm is the direct band froni P_(15) toP_(25) 展开更多
关键词 Porous Si time-resolved spectra Nanocrystal PHOTOLUMINESCENCE
下载PDF
TIME-RESOLVED IMPEDANCE RESPONSE OF GUILLOTINEDALUMINIUM UNDER GALVANOSTATIC POLARISATION
20
作者 C.Liu and G. T. Burstein(Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, CambridgeCB2 3QZ, United Kingdom) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1997年第4期297-303,共7页
Transient repassivation of freshly generated aluminiutn surface is monitored by using time-resolved frequency response spectroscopy. Information relating to the anodic film formation as well as the cathodic evolution ... Transient repassivation of freshly generated aluminiutn surface is monitored by using time-resolved frequency response spectroscopy. Information relating to the anodic film formation as well as the cathodic evolution of hydrogen on the metal surace is obtained as function of repassivation time and applied constant current. Pronounced effects of anodic and cathodic applied curmnts on the time-resolved impedance spectroscopy support a previous model which suggests that the low frequtncy RC time constants are due to the anodic film growth and the high Asquency one to the cathodic charpetrensfer or clectron transfer process occuwtng simultaneously on the electrode surace. 展开更多
关键词 aluminium time-resolved impedance repassivation bare metal surface
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部