期刊文献+
共找到759篇文章
< 1 2 38 >
每页显示 20 50 100
Ultrafast carrier dynamics in GeSn thin film based on time-resolved terahertz spectroscopy
1
作者 黄盼盼 张有禄 +3 位作者 胡凯 齐静波 张岱南 程亮 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期164-169,共6页
We measure the time-resolved terahertz spectroscopy of GeSn thin film and studied the ultrafast dynamics of its photo-generated carriers.The experimental results show that there are photo-generated carriers in GeSn un... We measure the time-resolved terahertz spectroscopy of GeSn thin film and studied the ultrafast dynamics of its photo-generated carriers.The experimental results show that there are photo-generated carriers in GeSn under femtosecond laser excitation at 2500 nm,and its pump-induced photoconductivity can be explained by the Drude–Smith model.The carrier recombination process is mainly dominated by defect-assisted Auger processes and defect capture.The firstand second-order recombination rates are obtained by the rate equation fitting,which are(2.6±1.1)×10^(-2)ps^(-1)and(6.6±1.8)×10^(-19)cm^(3)·ps^(-1),respectively.Meanwhile,we also obtain the diffusion length of photo-generated carriers in GeSn,which is about 0.4μm,and it changes with the pump delay time.These results are important for the GeSn-based infrared optoelectronic devices,and demonstrate that Ge Sn materials can be applied to high-speed optoelectronic detectors and other applications. 展开更多
关键词 GeSn thin film time-resolved THz spectroscopy ultrafast dynamics carrier recombination
下载PDF
Time-resolved characteristics of a nanosecond pulsed multi-hollow needle plate packed bed dielectric barrier discharge
2
作者 秦亮 李瑶 +6 位作者 郭浩 姜楠 宋颖 贾锐 周雄峰 袁皓 杨德正 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期48-57,共10页
In this paper,self-designed multi-hollow needle electrodes are used as a high-voltage electrode in a packed bed dielectric barrier discharge reactor to facilitate fast gas flow through the active discharge area and ac... In this paper,self-designed multi-hollow needle electrodes are used as a high-voltage electrode in a packed bed dielectric barrier discharge reactor to facilitate fast gas flow through the active discharge area and achieve large-volume stable discharge.The dynamic characteristics of the plasma,the generated active species,and the energy transfer mechanisms in both positive discharge(PD)and negative discharge(ND)are investigated by using fast-exposure intensified charge coupled device(ICCD)images and time-resolved optical emission spectra.The experimental results show that the discharge intensity,number of discharge channels,and discharge volume are obviously enhanced when the multi-needle electrode is replaced by a multihollow needle electrode.During a single voltage pulse period,PD mainly develops in a streamer mode,which results in a stronger discharge current,luminous intensity,and E/N compared with the diffuse mode observed in ND.In PD,as the gap between dielectric beads changes from 0 to250μm,the discharge between the dielectric bead gap changes from a partial discharge to a standing filamentary micro-discharge,which allows the plasma to leave the local area and is conducive to the propagation of surface streamers.In ND,the discharge only appears as a diffusionlike mode between the gap of dielectric beads,regardless of whether there is a discharge gap.Moreover,the generation of excited states N_(2)^(+)(B^(2)∑_(u)^(+))and N2(C^(3)Π_(u))is mainly observed in PD,which is attributed to the higher E/N in PD than that in ND.However,the generation of the OH(A^(2)∑^(+))radical in ND is higher than in PD.It is not directly dominated by E/N,but mainly by the resonant energy transfer process between metastable N_(2)(A^(3)∑_(u)^(+))and OH(X^(2)Π).Furthermore,both PD and ND demonstrate obvious energy relaxation processes of electron-to-vibration and vibration-to-vibration,and no vibration-to-rotation energy relaxation process is observed. 展开更多
关键词 packed bed reactor multi-hollow needle electrodes positive and negative discharges optical emission spectra time-resolved images
下载PDF
Establishment of Double-antigen Sandwich Time-resolved Fluorescence Immunoassay for Detection of Pest des Petits Ruminants Virus
3
作者 Binglei CAO Zhongyuan GE +3 位作者 Qi YANG Hang SUN Yu SUN Xiaohui SONG 《Agricultural Biotechnology》 2024年第4期21-27,共7页
[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PP... [Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PPR.[Methods]Soluble N protein and NH fusion protein were successfully obtained in an Escherichia coli expression system by optimizing E.coli codon and expression conditions.Furthermore,based on purified soluble N protein and NH fusion protein,a double-antigen sandwich time-resolved fluorescence immunoassay method for detection of peste des petits ruminants virus(PPRV)was established.[Results]The method has high sensitivity and specificity and can specifically detect the antibody against PPRV in sheep serum,and it has no cross reaction with other related diseases.The method was used to detect 292 clinical samples,and compared with French IDVET competition ELISA kit.The coincidence rates of positive samples and negative samples from the two kinds of test kits were 92.47%and 97.26%,respectively,and the overall coincidence rate was 94.86%.The intra-group and inter-group coefficients of variation in the repeatability test were less than 10%.[Conclusions]Compared with the traditional ELISA method,the double-antigen sandwich time-resolved fluorescence immunoassay for detection of PPRV has equivalent sensitivity and specificity,and simple and rapid operation,and thus high application and popularization value. 展开更多
关键词 Peste des petits ruminants N active protein NH fusion protein Soluble expression and purification time-resolved fluorescence immunoassay
下载PDF
Time-resolved K-shell x-ray spectra of nanosecond laser-produced titanium tracer in gold plasmas
4
作者 何贞岑 张继彦 +2 位作者 杨家敏 闫冰 胡智民 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期51-55,共5页
A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By co... A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By comparing the simulated spectra obtained by using the FLYCHK code with the measured titanium spectra, the temporal plasma states, i.e.,the electron temperatures and densities, are deduced. To evaluate the feasibility of using the method for the characterization of Au plasma states, the deduced plasma states from the measured titanium spectra are compared with the Multi-1D hydrodynamic simulations of laser-produced Au plasmas. By comparing the measured and simulated results, an overall agreement for the electron temperatures is found, whereas there are deviations in the electron densities. The experiment–theory discrepancy may suggest that the plasma state could not be well reproduced by the Multi-1D hydrodynamic simulation, in which the radial gradient is not taken into account. Further investigations on the spectral characterization and hydrodynamic simulations of the plasma states are needed. All the measured and FLYCHK simulated spectra are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.57760/sciencedb.j00113.00032. 展开更多
关键词 nanosecond laser irradiation time-resolved x-ray spectra characterization of plasma states Multi-1D hydrodynamic simulations
下载PDF
^(13)C NMR、FT-IR、Raman和建模技术对烟煤和无烟煤分子结构的应用研究
5
作者 李元吉 代诚欣 +2 位作者 孟上九 张保勇 张强 《太原理工大学学报》 CAS 北大核心 2024年第6期1063-1072,共10页
【目的】探究高精度煤的结构演化及其机理的定量表征。【方法】通过显微组分鉴定、镜质体反射率、工业品质、元素分析和光谱分析,确定了烟煤(FS1)和无烟煤(ZY1)碳骨架结构、官能团的赋存状态等信息,并通过计算机辅助分子设计建立2个分... 【目的】探究高精度煤的结构演化及其机理的定量表征。【方法】通过显微组分鉴定、镜质体反射率、工业品质、元素分析和光谱分析,确定了烟煤(FS1)和无烟煤(ZY1)碳骨架结构、官能团的赋存状态等信息,并通过计算机辅助分子设计建立2个分子结构模型。【结果】结果表明,随着煤化作用的进行,烟煤到无烟煤过程中,亚甲基的损失速率比甲基的损失速率快,芳香性增强,芳香环的脂肪族链变短且支化度较高,含氧官能团逐渐减少,煤结晶程度增强,煤的化学结构趋于成熟稳定,且煤中的脂肪碳减少,芳香碳增加,甲基碳和亚甲基碳含量减少。经过多次尝试确定了芳香炭、脂肪族侧链和氧官能团之间的键合模式,获得最终的分子结构模型:C_(175)H_(162)O_(13)N_(2)(FS1)、C_(190)H_(159)O_(5)N_(3)(ZY1).该模型较好地反映煤的真实结构,模拟的^(13)C NMR光谱与实验光谱具有良好的一致性。上述研究为不同变质程度煤的分子结构演化提供了理论参考,为建立高可信度的分子结构表征提供了方法。 展开更多
关键词 ^(13)C NMR ft-ir RAMAN 分子结构模型
下载PDF
Time-resolved photoluminescence of anatase/rutile TiO_2 phase junction revealing charge separation dynamics 被引量:3
6
作者 王秀丽 沈帅 +1 位作者 冯兆池 李灿 《Chinese Journal of Catalysis》 SCIE EI CAS CSCD 北大核心 2016年第12期2059-2068,共10页
Junctions are an important structure that allows charge separation in solar cells and photocatalysts. Here, we studied the charge transfer at an anatase/rutile TiO2 phase junction using time-resolved photoluminescence... Junctions are an important structure that allows charge separation in solar cells and photocatalysts. Here, we studied the charge transfer at an anatase/rutile TiO2 phase junction using time-resolved photoluminescence spectroscopy. Visible (-S00 nm) and near-infrared (NIR, -830 nm) emissions were monitored to give insight into the photoinduced charges of anatase and rutile in the junction, respectively, New fast photoluminescence decay components appeared in the visible emission of futile-phase dominated TiO2 and in the NIR emission of many mixed phase TiO2samples. The fast decays confirmed that the charge separation occurred at the phase junction. The visible emission intensity from the mixed phase TiO2 increased, revealing that charge transfer from rutile to anatase was the main pathway. The charge separation slowed the microsecond time scale photolumines- cence decay rate for charge carriers in both anatase and rutile. However, the millisecond decay of the charge carriers in anatase TiO2 was accelerated, while there was almost no change in the charge carrier dynamics of rutile TiO2. Thus, charge separation at the anatase/rutile phase junction caused an increase in the charge carrier concentration on a microsecond time scale, because of slower electron-hole recombination. The enhanced photocatalytic activity previously observed at ana- tase/rutile phase junctions is likely caused by the improved charge carrier dynamics we report here. These findings may contribute to the development of improved photocatalytic materials. 展开更多
关键词 Titanium dioxide (TiO2)Anatase/rutile phase junctionCharge separation Charge recombination time-resolved photoluminescence
下载PDF
Ultrafast Dynamics Through Conical Intersections in 2,6-dimethylpyridine Studied with Time-resolved Photoelectron Imaging
7
作者 邱学军 朱荣淑 +3 位作者 徐晏琪 布玛利亚·阿布力米提 张嵩 张冰 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2011年第5期551-556,I0003,共7页
The ultrafast dynamics through conical intersections in 2,6-dimethylpyridine has been studied by femtosecond time-resolved photoelectron imaging coupled with time-resolved mass spectroscopy. Upon absorption of 266 nm ... The ultrafast dynamics through conical intersections in 2,6-dimethylpyridine has been studied by femtosecond time-resolved photoelectron imaging coupled with time-resolved mass spectroscopy. Upon absorption of 266 nm pump laser, 2,6-dimethylpyridine is excited to the S2 state with a ππ character from So state. The time evolution of the parent ion signals consists of two exponential decays. One is a fast component on a timescale of 635 fs and the other is a slow component with a timescale of 4.37 ps. Time-dependent photo- electron angular distributions and energy-resolved photoelectron spectroscopy are extracted from time-resolved photoelectron imaging and provide the evolutive information of S2 state. In brief, the ultrafast component is a population transfer from S2 to S1 through the S2/S1 conical intersections, the slow component is attributed to simultaneous IC from the S2 state and the higher vibrational levels of S1 state to So state, which involves the coupling of S2/S0 and S1/So conical intersections. Additionally, the observed ultrafast S2--+S1 transition occurs only with an 18% branching ratio. 展开更多
关键词 2 6-dimethylpyridine Photoelectron imaging Conical intersection Internalconversion time-resolved spectroscopy
下载PDF
Distance-Dependent Long-Range Electron Transfer in Protein:a Case Study of Photosynthetic Bacterial Light-Harvesting Antenna Complex LH2 Assembled on TiO 2 Nanoparticle by Femto-Second Time-Resolved Spectroscopy
8
作者 翁羽翔 张蕾 +9 位作者 杨健 全冬晖 汪力 杨国桢 藤井律子 小山泰 张建平 冯娟 余军华 张宝文 《Acta Botanica Sinica》 CSCD 2003年第4期488-493,共6页
The function of protein in long-range biological electron transfer is a question of debate. We report some preliminary results in femtosecond spectroscopic study of photosynthetic bacterial light-harvesting antenna co... The function of protein in long-range biological electron transfer is a question of debate. We report some preliminary results in femtosecond spectroscopic study of photosynthetic bacterial light-harvesting antenna complex assembled onto TiO2 nanoparticle with an average size of 8 nm in diameter. Crystal structure shows that photosynthetic bacterial antenna complex LH2 has a ring-like structure composed by alpha- and beta-apoprotein helices. The alpha- and beta-transmembrance helices construct two concentric cylinders with pigments bacteriochlorophyll a (Bchl a) and carotenoid (Car) buried inside the protein. We attempt to insert TiO2 nanoparticle into the cavity of the inner cylindrical hollow of LH2 to investigate the nature of the electron transfer between the excited-state Bchl a and the TiO2 nanoparticle. A significant decrease in the ground state bleaching recovery time constant for Bchl a at 850 run (B850) in respect to that of the Bchl a in free LH2 has been observed. By using the relation of distance-dependent long-range electron transfer rate in protein, the distance between the donor B850 and the acceptor TiO2 nanoparticle has been estimated, which is about 0.6 nm. The proposed method of assembling proteins onto wide-gap semiconductor nanoparticle can be a promising way to determine the role of the protein playing in biological electron transfer processes. 展开更多
关键词 TiO2 nanoparticle LH2 time-resolved spectroscopy charge transfer energy transfer protein
下载PDF
A New kHz Velocity Map Ion/Electron Imaging Spectrometer for Femtosecond Time-Resolved M olecular Reaction Dynamics Studies
9
作者 贺志刚 陈志超 +3 位作者 杨栋元 戴东旭 吴国荣 杨学明 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2017年第3期247-252,I0001,共7页
A new velocity map imaging spectrometer is constructed for molecular reaction dynamics studies using time-resolved photoelectron/ion spectroscopy method. By combining a kHz pulsed valve and an ICCD camera, this veloci... A new velocity map imaging spectrometer is constructed for molecular reaction dynamics studies using time-resolved photoelectron/ion spectroscopy method. By combining a kHz pulsed valve and an ICCD camera, this velocity map imaging spectrometer can be run at a repetition rate of 1 kHz, totally compatible with the fs Ti:Sapphire laser system, facilitating time-resolved studies in gas phase which are usually time-consuming. Time-resolved velocity map imaging study of NH3 photodissociation at 200 nm was performed and the time-resolved total kinetic energy release spectrum of H+NH~ products provides rich information about the dissociation dynamics of NH3. These results show that this new apparatus is a powerful tool for investigating the molecular reaction dynamics using time-resolved methods. 展开更多
关键词 Photoelectron spectrum Pump/probe Femtosecond time-resolved
下载PDF
Photochemical Reaction of Benzoin Caged Compound: Time-Resolved Fourier Transform Infrared Spectroscopy Study
10
作者 代小娟 余友清 +1 位作者 刘坤辉 苏红梅 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第1期91-98,I0002,共9页
The benzoin group caged compound has received strong interests due to its excellent photo- deprotection properties and wide use in chemical and biological studies. We used timeresolved infrared spectroscopy to investi... The benzoin group caged compound has received strong interests due to its excellent photo- deprotection properties and wide use in chemical and biological studies. We used timeresolved infrared spectroscopy to investigate the photochemical reaction of the benzoin caged compound, o-(2-methylbenzoyl)-DL-benzoin under 266 nm laser irradiation. Taking advantage of the specific vibrational marker bands and the IR discerning capability, we have detected and identified the uncaging product 2-methylbenzoic acid, and two intermediate radicals of benzoyl and 2-methylbenzoate benzyl in the transient infrared spectra. Our results provide spectral evidence to support the homolytic cleavage reaction of C-C=O bond in competition with the deprotection reaction. Moreover, the product yields of 2-methylbenzoic acid and benzoyl radical were observed to be affected by solvents and a largely water contalning solvent can be in favor of the deprotection reaction. 展开更多
关键词 BENZOIN Caged compound Photo-deprotection time-resolved infrared spectroscopy
下载PDF
Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration 被引量:5
11
作者 Han-Chun Yao Min Sun +2 位作者 Xiao-Feng Yang Zhen-Zhong Zhang Hua Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期32-38,共7页
The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CP... The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation. 展开更多
关键词 time-resolved chemiluminescence artificial neural network CAPTOPRIL HYDROCHLOROTHIAZIDE
下载PDF
Time-resolved fluoroimmunoassay of zearalenone in cereals with a europium chelate as label 被引量:5
12
作者 马智鸿 黄飚 +3 位作者 张珏 张艺 朱岚 屠蔷 《Journal of Rare Earths》 SCIE EI CAS CSCD 2009年第6期1088-1091,共4页
A competitive indirect time-resolved fluoroimmunoassay(TRFIA) was developed for detection of zearalenone(ZEN) in cereals,in which ZEN conjugated to bovine serum albumin(BSA) is used as solid-phase antigen.A competitiv... A competitive indirect time-resolved fluoroimmunoassay(TRFIA) was developed for detection of zearalenone(ZEN) in cereals,in which ZEN conjugated to bovine serum albumin(BSA) is used as solid-phase antigen.A competitive indirect TRFIA was conducted by simultaneously incubating ZEN in standard or extracted samples with anti-ZEN monoclonal antibody over ZEN-BSA coated plates,and then determining the bound ZEN monoclonal antibody with goat anti-mouse europium conjugate.Samples were extracted with methanol/water... 展开更多
关键词 time-resolved fluoroimmunoassay ZEARALENONE EUROPIUM rare earths food safety
下载PDF
Investigation on Exciton Relaxation Kinetics of ZnCulnS/ZnSe/ZnS Quantum Dots by Time-Resolved Spectroscopy Techniques
13
作者 李雪璁 隋宁 张宇 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2015年第1期54-58,I0001,共6页
The exciton relaxation kinetics of ZnCuInS/ZnSe/ZnS quantum dots (QDs) is investigated by time-resolved spectroscopy techniques in detail. Based on the rate distribution model, the wavelength-dependent emission dyna... The exciton relaxation kinetics of ZnCuInS/ZnSe/ZnS quantum dots (QDs) is investigated by time-resolved spectroscopy techniques in detail. Based on the rate distribution model, the wavelength-dependent emission dynamics shows that the intrinsic exciton, the exciton in the interface defect state and that in donor-acceptor pair state (DAPS) together participate in the photoluminescence process of QDs, and the whole emission process is mainly dependent on the DAPS emission. Transient absorption data show that the intrinsic exciton and the interface defect species maybe together appear after excitation and the intensity-dependent Auger recombination process also exists in QDs at high excitation intensity. 展开更多
关键词 Quantum dots time-resolved spectroscopy Exciton relaxation kinetics
下载PDF
Analysis of Turbulence Structure in the Stirred Tank with a Deep Hollow Blade Disc Turbine by Time-resolved PIV 被引量:6
14
作者 刘心洪 包雨云 +1 位作者 李志鹏 高正明 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第4期588-599,共12页
The turbulence structure in the stirred tank with a deep hollow blade(semi-ellispe) disc turbine(HEDT) was investigated by using time-resolved particle image velocimetry(TRPIV) and traditional PIV.In the stirred tank,... The turbulence structure in the stirred tank with a deep hollow blade(semi-ellispe) disc turbine(HEDT) was investigated by using time-resolved particle image velocimetry(TRPIV) and traditional PIV.In the stirred tank,the turbulence generated by blade passage includes the periodic components and the random turbulent ones.Traditional PIV with angle-resolved measurement and TRPIV with wavelet analysis were both used to obtain the random turbulent kinetic energy as a comparison.The wavelet analysis method was successfully used in this work to separate the random turbulent kinetic energy.The distributions of the periodic kinetic energy and the random turbulent kinetic energy were obtained.In the impeller region,the averaged random turbulent kinetic energy was about 2.6 times of the averaged periodic one.The kinetic energies at different wavelet scales from a6 to d1 were also calculated and compared.TRPIV was used to record the sequence of instantaneous velocity in the impeller stream.The evolution of the impeller stream was observed clearly and the sequence of the vorticity field was also obtained for the identification of vortices.The slope of the energy spectrum was approximately-5/3 in high frequency representing the existence of inertial subrange and some isotropic properties in stirred tank.From the power spectral density(PSD) ,one peak existed evidently,which was located at f0(blade passage frequency) generated by the blade passage. 展开更多
关键词 stirred tank time-resolved particle image velocimetry wavelet analysis energy spectrum power spectral density turbulent kinetic energy
下载PDF
Time-resolved shadowgraphs and morphology analyses of aluminum ablation with multiple femtosecond laser pulses 被引量:2
15
作者 Zehua Wu Nan Zhang +3 位作者 Xiaonong Zhu Liqun An Gangzhi Wang Ming Tan 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期536-542,共7页
Aluminum ablation by multiple femtosecond laser pulses is investigated via time-resolved shadowgraphs and scanning electron microscope (SEM) images of the ablation spot. The spatial distribution of the ejected mater... Aluminum ablation by multiple femtosecond laser pulses is investigated via time-resolved shadowgraphs and scanning electron microscope (SEM) images of the ablation spot. The spatial distribution of the ejected material and the radius of the shock wave generated during the ablation are found to vary with the increase in the number of pulses. In the initial two pulses, nearly concentric and semicircular stripes within the shock wave front are observed, unlike in subsequent pulses. Ablation by multiple femtosecond pulses exhibits different characteristics compared with the case induced by single femtosecond pulse because of the changes to the aluminum target surface induced by the preceding pulses. 展开更多
关键词 femtosecond laser ablation ultrafast phenomena time-resolved shadowgraphs morphology analyses
下载PDF
Study on local topology model of low/high streak structures in wall-bounded turbulence by tomographic time-resolved particle image velocimetry 被引量:6
16
作者 Haiping TIAN Nan JIANG +1 位作者 Yongxiang HUANG Shaoqiong YANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2015年第9期1121-1130,共10页
The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry... The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak. 展开更多
关键词 wall turbulence quadrupole topological structure hairpin vortex low/highspeed streak tomographic time-resolved particle image velocimetry (TRPIV) system
下载PDF
Simultaneous measurements of global vibrational spectra and dephasing times of molecular vibrational modes by broadband time-resolved coherent anti-Stokes Raman scattering spectrography 被引量:2
17
作者 尹君 于凌尧 +3 位作者 刘星 万辉 林子扬 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期385-391,共7页
In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of variou... In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of various spectral components of SC in an enough bandwidth. By numerical simulations, the optimal experimental conditions for improving the SC are obtained. The broadband time-resolved CARS spectrography based on the SC with required temporal and spectral distributions is realised. The global molecular vibrational spectrum with well suppressed nonresonant background noise can be obtained in a single measurement. At the same time, the measurements of dephasing times of various molecular vibrational modes can be conveniently achieved from intensities of a sequence of time-resolved CARS signals. It will be more helpful to provide a complete picture of molecular vibrations, and to exhibit a potential to understand not only both the solvent dynamics and the solute-solvent interactions, but also the mechanisms of chemical reactions in the fields of biology, chemistry and material science. 展开更多
关键词 coherent anti-Stokes Raman scattering photonic crystal fibre SUPERCONTINUUM molecular vibrational spectrum dephasing time time-resolved measurement
下载PDF
Eu-Chelate Construct Ultrasensitive Time-Resolved Fluoroimmunoassay-Assay of Pepsinogen I 被引量:1
18
作者 黄飚 张祥瑞 +3 位作者 朱岚 刘海燕 蒋叶华 金坚 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期381-384,共4页
Eu-chelate were used to construct a two-site sandwich-type assay for pepsinogen Ⅰ (PGI) with time-resolved fluoroimmunoassay (TRFIA) as a detection technique. On the noncompetitive assay, captured monoclonal anti... Eu-chelate were used to construct a two-site sandwich-type assay for pepsinogen Ⅰ (PGI) with time-resolved fluoroimmunoassay (TRFIA) as a detection technique. On the noncompetitive assay, captured monoclonal antibodies (McAbs) coated on wells were directed against a specific antigenic site on the PGI. Another McAbs, called as labeling McAbs, were prepared with the Eu-chelate of N-(p-isothiocyanatobenzyl)-diethylenetriamine-N, N, N, N-tetraacetic acid and directed against a different antigenic site on the PGI. The fluorescence counts of bound Eu^3+ -McAbs were measured with the auto DELFIA1235 system. The PGI in sera from healthy volunteers were determined by PGI-TRFIA. The within-run and between-run CVs of the PGI-TRFIA were 1.9% and 4.7%, respectively, and the recovery rate was 102.65%. The assay had a detection limit of 0.05 μg· L^-1. The PGI-TRFIA provided a linear response from 3.5 to 328 μg· L^-1. The cross-reacting rate with pepsinogen Ⅱ was negligible. The linear correlation of PGI-TRFIA and radioimmunassay measurements resulted in a correlation coefficient of 0.977. The means of healthy volunteers were 154 ±43 μg·L^-1 for serum PGI. The availability of a highly sensitive, reliable, and convenient method for quantifying PGI will allow investigations into the possible diagnostic value of this analyte in various clinical conditions, including gastric carcinoma, duodenal ulcer, gastritis and severe atrophic gastritis. 展开更多
关键词 time-resolved fluoroimmunoassay pepsinogen Eu-chelate rare earths
下载PDF
A Highly Sensitive Femtosecond Time-Resolved Sum Frequency Generation Vibrational Spectroscopy System with Simultaneous Measurement of Multiple Polarization Combinations 被引量:2
19
作者 谈军军 罗毅 叶树集 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2017年第6期671-677,I0002,共8页
Characterization of real-time and ultrafast motions of the complex molecules at surface and interface is critical to understand how interracial molecules function. It requires to develop surface-sensitive, fast-identi... Characterization of real-time and ultrafast motions of the complex molecules at surface and interface is critical to understand how interracial molecules function. It requires to develop surface-sensitive, fast-identification, and time-resolved techniques. In this study, we employ several key technical procedures and successfully develop a highly sensitive femtosecond time-resolved sum frequency generation vibrational spectroscopy (SFG-VS) system. This system is able to measure the spectra with two polarization combinations (ssp and ppp, or psp and ssp) simultaneously. It takes less than several seconds to collect one spectrum. To the best of our knowledge, it is the fastest speed of collecting SFG spectra reported by now. Using the time-resolved measurement, ultrafast vibrational dynamics of the N-H mode of α-helical peptide at water interface is determined. It is found that the membrane environment does not affect the N-H vibrational relaxation dynamics. It is expected that the time-resolved SFG system will play a vital role in the deep understanding of the dynamics and interaction of the complex molecules at surface and interface. Our method may also provide an important technical proposal for the people who plan to develop time-resolved SFG systems with simultaneous measurement of multiple polarization combinations. 展开更多
关键词 Femtosecond time-resolved Sum frequency generation vibrational spectroscopy Ultrafast vibrational dynamics Multiple polarization combination measurement CHIRAL
下载PDF
Time-resolved measurement of atomic emission enhancement by fs-ns dual-pulsed laser-induced breakdown spectroscopy 被引量:1
20
作者 颜立新 张永生 +3 位作者 郑国鑫 刘晶儒 程建平 吕敏 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第10期2271-2274,共4页
Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG ... Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization. 展开更多
关键词 time-resolved measurement atomic emission enhancement dual-pulse LIBS
下载PDF
上一页 1 2 38 下一页 到第
使用帮助 返回顶部