期刊文献+
共找到3,281篇文章
< 1 2 165 >
每页显示 20 50 100
Composition of high frequency ambient noise from cross-correlation:A case study using a small aperture array 被引量:6
1
作者 Weitao Wang Sidao Ni Baoshan Wang 《Earthquake Science》 CSCD 2010年第5期433-438,共6页
Long-time cross correlation of ambient noise has been proved as a powerful tool to extract Green's function between two receivers. The study of composition of ambient noise is important for a better understanding of ... Long-time cross correlation of ambient noise has been proved as a powerful tool to extract Green's function between two receivers. The study of composition of ambient noise is important for a better understanding of this method. Previous studies confirm that ambient noise in the long period (3 s and longer) mostly consists of surface wave, and 0.25-2.5 s noise consists more of body waves. In this paper, we perform cross correlation processing at much higher frequency (30-70 Hz) using ambient noise recorded by a small aperture array. No surface waves emerge from noise correlation function (NCF), but weak P waves emerge. The absence of surface wave in NCF is not due to high attenuation since surface waves are strong from active source, therefore probably the high ambient noise mostly consists of body wave and lacks surface wave. Origin of such high frequency body waves in ambient noise remains to be studied. 展开更多
关键词 ambient noise cross correlation Green's function body wave high frequency
下载PDF
Detection of Mechanical Deformation in Old Aged Power Transformer Using Cross Correlation Co-Efficient Analysis Method 被引量:2
2
作者 Asif Islam Shahidul Islam Khan Aminul Hoque 《Energy and Power Engineering》 2011年第4期585-591,共7页
Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an... Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electromechanical forces occurring from the fault currents or due to Transformer transportation and relocation. In this method, the frequency response of a transformer is taken both at manufacturing industry and concern site. Then both the response is compared to predict the fault taken place in active part. But in old aged transformers, the primary reference response is unavailable. So Cross Correlation Co-Efficient (CCF) measurement technique can be a vital process for fault detection in these transformers. In this paper, theoretical background of SFRA technique has been elaborated and through several case studies, the effectiveness of CCF parameter for fault detection has been represented. 展开更多
关键词 Core Damage RADIAL DEFORMATION AXIAL DEFORMATION SWEEP Frequency Response Analysis cross correlation Co-efficient Power Transformer
下载PDF
Temporal-spatial cross-correlation analysis of non-stationary near-surface wind speed time series 被引量:3
3
作者 曾明 李静海 +1 位作者 孟庆浩 张小内 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第3期692-698,共7页
Temporal-spatial cross-correlation analysis of non-stationary wind speed time series plays a crucial role in wind field reconstruction as well as in wind pattern recognition.Firstly,the near-surface wind speed time se... Temporal-spatial cross-correlation analysis of non-stationary wind speed time series plays a crucial role in wind field reconstruction as well as in wind pattern recognition.Firstly,the near-surface wind speed time series recorded at different locations are studied using the detrended fluctuation analysis(DFA),and the corresponding scaling exponents are larger than 1.This indicates that all these wind speed time series have non-stationary characteristics.Secondly,concerning this special feature( i.e.,non-stationarity)of wind signals,a cross-correlation analysis method,namely detrended cross-correlation analysis(DCCA) coefficient,is employed to evaluate the temporal-spatial cross-correlations between non-stationary time series of different anemometer pairs.Finally,experiments on ten wind speed data synchronously collected by the ten anemometers with equidistant arrangement illustrate that the method of DCCA cross-correlation coefficient can accurately analyze full-scale temporal-spatial cross-correlation between non-stationary time series and also can easily identify the seasonal component,while three traditional cross-correlation techniques(i.e.,Pearson coefficient,cross-correlation function,and DCCA method) cannot give us these information directly. 展开更多
关键词 非平稳时间序列 热线风速仪 互相关分析 时空相关 近地表 相关分析方法 模式识别 DCCA
下载PDF
Reconstruction of sub cross-correlation cancellation technique for unambiguous acquisition of BOC(kn, n) signals 被引量:5
4
作者 JI Yuanfa CHEN Xiaoqian +2 位作者 FU Qiang SUN Xiyan ZHEN Weimin 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第5期852-860,共9页
In order to solve the problem of ambiguous acquisition of BOC signals caused by its property of multiple peaks,an unambiguous acquisition algorithm named reconstruction of sub cross-correlation cancellation technique(... In order to solve the problem of ambiguous acquisition of BOC signals caused by its property of multiple peaks,an unambiguous acquisition algorithm named reconstruction of sub cross-correlation cancellation technique(RSCCT)for BOC(kn,n)signals is proposed.In this paper,the principle of signal decomposition is combined with the traditional acquisition algorithm structure,and then based on the method of reconstructing the correlation function.The method firstly gets the sub-pseudorandom noise(PRN)code by decomposing the local PRN code,then uses BOC(kn,n)and the sub-PRN code cross-correlation to get the sub cross-correlation function.Finally,the correlation peak with a single peak is obtained by reconstructing the sub cross-correlation function so that the ambiguities of BOC acquisition are removed.The simulation shows that RSCCT can completely eliminate the side peaks of BOC(kn,n)group signals while maintaining the narrow correlation of BOC,and its computational complexity is equivalent to sub carrier phase cancellation(SCPC)and autocorrelation side-peak cancellation technique(ASPeCT),and it reduces the computational complexity relative to BPSK-like.For BOC(n,n),the acquisition sensitivity of RSCCT is 3.25 dB,0.81 dB and 0.25 dB higher than binary phase shift keying(BPSK)-like,SCPC and ASPeCT at the acquisition probability of 90%,respectively.The peak to average power ratio is 1.91,3.0 and 3.7 times higher than ASPeCT,SCPC and BPSK-like at SNR=–20 dB,respectively.For BOC(2n,n),the acquisition sensitivity of RSCCT is 5.5 dB,1.25 dB and 2.69 dB higher than BPSK-like,SCPC and ASPeCT at the acquisition probability of 90%,respectively.The peak to average power ratio is 1.02,1.68 and 2.12 times higher than ASPeCT,SCPC and BPSK-like at SNR=–20 dB,respectively. 展开更多
关键词 signal decomposition SUB cross-correlation reconstructingcorrelation function ACQUISITION performance
下载PDF
Teleseismic body waves extracted from ambient noise cross correlation between F-net and Chin Array phase Ⅱ 被引量:1
5
作者 Lin Deng Weitao Wang +1 位作者 Fang Wang Songyong Yuan 《Earthquake Research Advances》 CSCD 2022年第1期33-43,共11页
The vertical-vertical noise cross-correlation functions(NCFs)between two seismic arrays,the Japan F-net and Chin Array phase Ⅱ,are calculated using continuous recordings during 2013-2016.After array interferometry to... The vertical-vertical noise cross-correlation functions(NCFs)between two seismic arrays,the Japan F-net and Chin Array phase Ⅱ,are calculated using continuous recordings during 2013-2016.After array interferometry to obtain bin stacked NCFs,clear body waves are retrieved at different period bands.Teleseismic direct P waves for distance 15-40 degrees are observed between short period 3-10 s while core reflected PcP/ScS waves are more obvious for longer period 30-60 s.The signal-to-noise-ratio(SNR)of the short period P waves reaches its highest point with bin widths around 20 km while SNRs of PcP and ScS increase slowly with bin width.All those body waves demonstrate clear directivity with strong signals traveling from the east.The time-lapse SNR variations for the PcP and ScS show correlation with the occurrence of major earthquakes,while the P-wave SNR demonstrates seasonal variations with additional contribution from major earthquakes.The present results suggest teleseismic body waves can be retrieved through bin stacking,though further processing is still necessary to obtain finer waveforms such as P wave triplications. 展开更多
关键词 Noise cross correlation Body waves Array interferometry ChinArray
下载PDF
Estimation of Cloud Motion Using Cross-Correlation 被引量:6
6
作者 李振军 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 1998年第2期144-149,共6页
This paper describes the estimation of cloud motion using lag cross-correlation. In order to compute the lag cross correlation, the Bayes Decision method is used first to identify cloud and surface of earth. Then clou... This paper describes the estimation of cloud motion using lag cross-correlation. In order to compute the lag cross correlation, the Bayes Decision method is used first to identify cloud and surface of earth. Then cloud motion vectors are retrieved at a subset of points through multiple applications of a cross-correlation analysis. An objective analysis is used to define displacement at every satellite pixel throughout the domain and smooth the local inconsistencies. Cloud motions are then produced with a backward trajectory technique by using these displacement vectors. 展开更多
关键词 Satellite cloud image Cloud motion cross-correlation Cloud identification
下载PDF
Detrended cross-correlation analysis of electroencephalogram 被引量:5
7
作者 王俊 赵大庆 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期577-580,共4页
In the paper we use detrended cross-correlation analysis (DCCA) to study the electroencephalograms of healthy young subjects and healthy old subjects. It is found that the cross-correlation between different leads o... In the paper we use detrended cross-correlation analysis (DCCA) to study the electroencephalograms of healthy young subjects and healthy old subjects. It is found that the cross-correlation between different leads of a healthy young subject is larger than that of a healthy old subject. It was shown that the cross-correlation relationship decreases with the aging process and the phenomenon can help to diagnose whether the subject's brain function is healthy or not. 展开更多
关键词 detrended cross-correlation analysis ELECTROENCEPHALOGRAM brain function aging process
下载PDF
RESEARCH ON THE ALGORITHM OF BINARY IMAGE CROSS-CORRELATION FOR UNSTEADY FLOW FIELD MEASUREMENT 被引量:2
8
作者 阮晓东 宋向群 YamamotoFujio 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1999年第1期32-38,共7页
The algorithm of Binary Image Cross-Correlation (BICC) was developed to measure the unsteady flow field. A vortex flow field was used to test the algorithm by numerical simulation. The results show that BICC is an e... The algorithm of Binary Image Cross-Correlation (BICC) was developed to measure the unsteady flow field. A vortex flow field was used to test the algorithm by numerical simulation. The results show that BICC is an effective algorithm for particle identification from consecutive images, the accurate velocity vector field can be obtained. The real velocity field in a valve chamber was measured by BICC in this study. From the full-field velocity information, the pressure and vorticity fields were also extracted by post-processing. (Edited author abstract) 6 Refs. 展开更多
关键词 PIV cross-correlation particle identification POST-PROCESSING
下载PDF
Public cloud computing for seismological research:Calculating large-scale noise cross-correlations using ALIYUN 被引量:3
9
作者 Weitao Wang Baoshan Wang Xiufen Zheng 《Earthquake Science》 CSCD 2018年第5期227-233,共7页
The amount of seismological data is rapidly increasing with accumulating observational time and increasing number of stations, requiring modern technique to provide adequate computing power. In present study, we propo... The amount of seismological data is rapidly increasing with accumulating observational time and increasing number of stations, requiring modern technique to provide adequate computing power. In present study, we proposed a framework to calculate large-scale noise crosscorrelation functions(NCFs) using public cloud service from ALIYUN. The entire computation is factorized into small pieces which are performed parallelly on specified number of virtual servers provided by the cloud. Using data from most seismic stations in China, five NCF databases are built. The results show that, comparing to the time cost using a single server, the entire time can be reduced over two orders of magnitude depending number of evoked virtual servers. This could reduce computation time from months to less than 12 hours. Based on obtained massive NCFs, the global body waves are retrieved through array interferometry and agree well with those from earthquakes. This leads to a solution to process massive seismic dataset within an affordable time and is applicable to other large-scale computing in seismological researches. 展开更多
关键词 cloud computing ambient noise cross-correlation global body wave
下载PDF
Understanding visual-auditory correlation from heterogeneous features for cross-media retrieval 被引量:2
10
作者 Hong ZHANG Yan-yun WANG +1 位作者 Hong PAN Fei WU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期241-249,共9页
Cross-media retrieval is an interesting research topic,which seeks to remove the barriers among different modalities.To enable cross-media retrieval,it is needed to find the correlation measures between heterogeneous ... Cross-media retrieval is an interesting research topic,which seeks to remove the barriers among different modalities.To enable cross-media retrieval,it is needed to find the correlation measures between heterogeneous low-level features and to judge the semantic similarity.This paper presents a novel approach to learn cross-media correlation between visual features and auditory features for image-audio retrieval.A semi-supervised correlation preserving mapping(SSCPM)method is described to construct the isomorphic SSCPM subspace where canonical correlations between the original visual and auditory features are further preserved.Subspace optimization algorithm is proposed to improve the local image cluster and audio cluster quality in an interactive way.A unique relevance feedback strategy is developed to update the knowledge of cross-media correlation by learning from user behaviors,so retrieval performance is enhanced in a progressive manner.Experimental results show that the performance of our approach is effective. 展开更多
关键词 信息处理 多媒体技术 动力相关分析 子空间
下载PDF
Time correction of the ocean bottom seismometers deployed at the southwest Indian ridge using ambient noise cross-correlation 被引量:5
11
作者 LIU Yunlong LIU Cai +8 位作者 TAO Chunhui YAO Huajian QIU Lei WANG Ao RUAN Aiguo WANG Hanchuang ZHOU Jianping LI Huaiming DONG Chuanwan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2018年第5期39-46,共8页
Seismic monitoring using ocean bottom seismometers(OBS) is an efficient method for investigating earthquakes in mid-ocean ridge far away from land. Clock synchronization among the OBSs is difficult without direct co... Seismic monitoring using ocean bottom seismometers(OBS) is an efficient method for investigating earthquakes in mid-ocean ridge far away from land. Clock synchronization among the OBSs is difficult without direct communication because electromagnetic signals cannot propagate efficiently in water. Time correction can be estimated through global positioning system(GPS) synchronization if clock drift is linear before and after the deployment. However, some OBSs in the experiments at the southwest Indian ridge(SWIR) on the Chinese DY125-34 cruise had not been re-synchronized from GPS after recovery. So we attempted to estimate clock drift between each station pairs using time symmetry analysis(TSA) based on ambient noise cross-correlation. We tested the feasibility of the TSA method by analyzing daily noise cross-correlation functions(NCFs) that extract from the data of another OBS experiment on the Chinese DY125-40 cruise with known clock drift and the same deployment site. The results suggest that the NCFs' travel time of surface wave between any two stations are symmetrical and have an opposite growing direction with the date. The influence of different band-pass filters,different components and different normalized methods was discussed. The TSA method appeared to be optimal for the hydrophone data within the period band of 2–5 s in dozens of km-scale interstation distances. A significant clock drift of ~2 s was estimated between OBSs sets through linear regression during a 108-d deployment on the Chinese cruise DY125-34. Time correction of the OBS by the ambient noise cross-correlation was demonstrated as a practical approach with the appropriate parameters in case of no GPS re-synchronization. 展开更多
关键词 clock drift cross-correlation ambient noise OBS
下载PDF
AN IMPROVED CROSS-CORRELATION METHOD FOR(DIGITAL)PARTICLE IMAGE VELOCIMETRY 被引量:1
12
作者 翁文国 范维澄 +1 位作者 廖光煊 秦俊 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2001年第4期332-339,共8页
An improved method that brings enhancement in accuracy for the interrogation of (digital) PIV images is described in this paper. This method is based on cross-correlation with discrete window offset, which makes use o... An improved method that brings enhancement in accuracy for the interrogation of (digital) PIV images is described in this paper. This method is based on cross-correlation with discrete window offset, which makes use of a translation of the second interrogation window and rebuilds it considering rotation and shear. The displacement extracted from PIV images is predicted and corrected by means of an iterative procedure. In addition, the displacement vectors are validated at each intermediate of the iteration process. The present improved cross-correlation method is compared with the conventional one in accuracy by interrogation of synthetic and real (digital) PIV images and the interrogation results are discussed. 展开更多
关键词 PIV DPIV cross-correlation discrete window offset
下载PDF
Eigenvalue Modeling and Cross-Correlation Analysis for 6. 0- 6. 4 GHz MIMO Channel 被引量:1
13
作者 Ji-Liang Zhang Yang Wang +2 位作者 Li-Qin Ding Xiao-Min Huang Nai-Tong Zhang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第5期1-5,共5页
In Multiple-Input Multiple-Output( MIMO) system, the number of positive channel matrix eigenvalues is directly related to system performance. In order to characterize and model channel matrix eigenvalues,channel measu... In Multiple-Input Multiple-Output( MIMO) system, the number of positive channel matrix eigenvalues is directly related to system performance. In order to characterize and model channel matrix eigenvalues,channel measurements at 6. 0- 6. 4GHz by using 4 × 4 MIMO structure were conducted in a typical classroom environment. Based on measured data, the eigenvalues were modeled as Log-Normal distributed random variables and parameterized. Furthermore, Cross-Correlation( CC) coefficients of eigenvalues were estimated. The measurement results show that,under both Light-Of-Sight( LOS) and NonLight-Of-Sight( NLOS) scenarios,eigenvalues are highly de-correlated so that CC can be ignored for eigenvalue model. 展开更多
关键词 MIMO channel modeling EIGENVALUE measurement cross-correlation
下载PDF
DETECTING TECHNIQUE OF WEAK PERIODIC PULSE SIGNAL VIA SYNTHESIS OF CROSS-CORRELATION AND CHAOTIC SYSTEM 被引量:4
14
作者 LiYue YangBaojun +1 位作者 LuPeng LiShizhe 《Journal of Electronics(China)》 2003年第5期397-400,共4页
In this letter, with the synthesis of usual cross-correlation detecting method andchaotic detecting method, a new detecting system for the weak periodic pulse signal is constituted,in which the two methods can play re... In this letter, with the synthesis of usual cross-correlation detecting method andchaotic detecting method, a new detecting system for the weak periodic pulse signal is constituted,in which the two methods can play respective preponderance. Theoretical analyses and simulationstudies have shown that the detecting system is very sensitive to the periodic pulse signal understrong noise background and has exceedingly powerful capability of suppressing complex noise. 展开更多
关键词 信噪比 信号检测 交叉相关 浑沌系统 周期脉冲信号
下载PDF
Time dependence of entropy flux and entropy production for a dynamical system driven by noises with coloured cross-correlation 被引量:2
15
作者 谢文贤 徐伟 蔡力 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第1期42-46,共5页
This paper shows the Fokker-Planck equation of a dynamical system driven by coloured cross-correlated white noises in the absence and presence of a small external force. Based on the Fokker-Planck equation and the def... This paper shows the Fokker-Planck equation of a dynamical system driven by coloured cross-correlated white noises in the absence and presence of a small external force. Based on the Fokker-Planck equation and the definition of Shannon's information entropy, the time dependence of entropy flux and entropy production can be calculated. The present results can be used to explain the extremal behaviour of time dependence of entropy flux and entropy production in view of the dissipative parameter γ of the system, coloured cross-correlation time τ and coloured cross-correlation strength λ. 展开更多
关键词 information entropy entropy flux entropy production coloured cross-correlation Fokker-Planck equation
下载PDF
USING CROSS-CORRELATION THEORY TO EXTRACT MODAL PARAMETERS IN FREQUENCY- DOMAIN 被引量:1
16
作者 ShenFan ZhengMin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第1期83-86,共4页
Conventional modal parameter identifications are usually based on frequencyresponse functions, which require measurements of both the input force and the resulting response.However, in many cases, only response data a... Conventional modal parameter identifications are usually based on frequencyresponse functions, which require measurements of both the input force and the resulting response.However, in many cases, only response data are available while the actual excitations (such aswind/wave load) are not measurable. Modal parameters estimation must base itself on response-onlydata. Over the past years, many time-domain modal parameter identification techniques fromoutput-only are proposed. A poly-reference frequency-domain modal identification scheme onresponse-only is presented. It is based on coupling the cross-correlation theory with conventionalfrequency-domain modal parameter extraction. An experiment using an airplane model is performed toverify the proposed method. 展开更多
关键词 Modal identification Vibration testing cross-correlation theory Operating conditions
下载PDF
An Optimized Cross Correlation Power Attack of Message Blinding Exponentiation Algorithms 被引量:1
17
作者 WAN Wunan YANG Wei CHEN Jun 《China Communications》 SCIE CSCD 2015年第6期22-32,共11页
The message blinding method is the most efficient and secure countermeasure against first-order differential power analysis(DPA).Although cross correlation attacks(CCAs) were given for defeating message blinding metho... The message blinding method is the most efficient and secure countermeasure against first-order differential power analysis(DPA).Although cross correlation attacks(CCAs) were given for defeating message blinding methods,however searching for correlation points is difficult for noise,misalignment in practical environment.In this paper,we propose an optimized cross correlation power attack for message blinding exponentiation algorithms.The attack method can select the more correlative power points of share one operation in the modular multiplication by comparing variances between correlation coefficients.Further we demonstrate that the attack method is more efficient in experiments with hardware implementation of RSA on a crypto chip card.In addition to the proposed CCA method can recovery all 1024 bits secret key and recognition rate increases to 100%even when the recorded signals are noisy. 展开更多
关键词 相关攻击 相关信息 算法 致盲 优化 功率分析 相关系数 硬件实现
下载PDF
A New Method For Mitigation Of Cross Correlation In GPS Receiver
18
作者 Shao-lei Yi~1 Hui LI~2 (1.College of Information & Electric Engineering Shandong University of Science & Technology Qingdao,China,266510 2.Institute of Information Engineering China University of Mining & Technology Beijing,China,100083) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期5-10,共6页
An algorithm for GPS receiver performing to mitigate cross correlations between weak satellite signal and strong satellite signals is presented.By using the tracking result of strong signal,the cross-correlation and c... An algorithm for GPS receiver performing to mitigate cross correlations between weak satellite signal and strong satellite signals is presented.By using the tracking result of strong signal,the cross-correlation and cross correlation sequence between weak signals and strong signal can be computed,further modifying the local generate C/A code to drive the cross correlation to zero. The advantage of this method is that it does not require estimation of the strong signal amplitude and it partially independent of the data bit value.Simulation result shows it can eliminate the interference of 75%,and this method is at the cost of sensitivity loss of 0.28dB. 展开更多
关键词 cross correlation RELATIVE DOPPLER frequency SHIFT
下载PDF
Simulation of distributed optical fiber disturbance detection system based on Sagnac/Mach-Zehnder interferometer and cross-correlation location 被引量:2
19
作者 方捻 李杰 +2 位作者 王陆唐 黄肇明 杨烨 《Journal of Shanghai University(English Edition)》 CAS 2011年第2期115-118,共4页
A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte... A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations. 展开更多
关键词 Sagnac interferometer Mach-Zehnder interferometer distributed optical fiber disturbance detection system cross-correlation LOCATION
下载PDF
The Failure of the Cross Correlation Measurement Technique
20
作者 Ken McGill Kathryn Ham Kris Schock 《Open Journal of Acoustics》 2015年第1期25-28,共4页
The experiment involves creating a sound wave that propagates down a pipe with 8 transducers attached at equally spaced intervals of 0.01016 m. The numerical method—the Cross Correlation Method, used to solve for the... The experiment involves creating a sound wave that propagates down a pipe with 8 transducers attached at equally spaced intervals of 0.01016 m. The numerical method—the Cross Correlation Method, used to solve for the phase component, creates a high correlation value, but the speed of sound varies immensely. The method involves a Fast Fourier Transform (FFT) of the collected data, which is used to find the phase of the sound wave, and the slope of the position versus time graph, which is used to calculate the speed of sound. This high correlation value shows that the data are correct, but the numerical method for analyzing the data is incorrect. 展开更多
关键词 ACOUSTIC ARRAY cross correlation FLOW Measurement
下载PDF
上一页 1 2 165 下一页 到第
使用帮助 返回顶部