To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogra...To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogram for digital hearing aids is proposed. First, a low-pass prototype filter is designed by the linear iterative algorithm. Secondly,the uniform CMFB is achieved on the basis of the principle formulas. Then, the adjacent channels of a uniform filter bank which have low or gradual slopes are merged according to the trend of audiogram of the hearing impaired person. Finally,the corresponding non-uniform CMFB is obtained. Simulation results show that the signal processed by the proposed filter bank is similar to the original signal in a time-domain waveform and spectrogram without significant distortion or difference. The speech quality results show that the personal evaluation of speech quality(PESQ) of non-uniform CMFB is 35% higher than that of the traditional design, and the hearing-aid speech quality index(HASQI) increases by about 40%.展开更多
The Vector Hydrophone(VH) is widely used to remotely detect underwater targets. Accurately measuring the self-noise of the VH provides an important basis for evaluating the performance of the detection system in which...The Vector Hydrophone(VH) is widely used to remotely detect underwater targets. Accurately measuring the self-noise of the VH provides an important basis for evaluating the performance of the detection system in which it is utilized, since the ability to acquire weak signals is determined by the VH self-noise level. To accurately measure the VH self-noise level in actual working conditions, the Dual-channel Transfer Function Method(DTFM) is proposed to reduce ambient background noise interference. In this paper, the underlying principles of DTFM in reducing ambient background noise is analyzed. The numerical simulations to determine the influence of ambient background noise, and the sensitivity difference of the two VHs on the measurement results are studied. The results of measuring the VH self-noise level in a small laboratory water tank by using DTMF indicate that ambient background noise interference can be reduced effectively by employing DTMF, more accurate self-noise level can be obtained as well. The DTMF provides an effective method for accurately measuring the self-noise level of VHs and also provides technical support for the practical application of the VH in underwater acoustics.展开更多
An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audio...An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audiometric transducer such as an earphone. The calibrated sound intensities for an audio-logical examination can be obtained in terms of the sound pressure levels of pure-tonal sinusoidal signals in eight-banded frequency ranges (250, 500, 1 000, 2 000, 3 000, 4 000, 6 000 and 8 000 Hz), and with mapping of the input sound pressure levels by the weight coefficients that are tuned by the delta learning rule. With this scheme, the sound intensities, which evoke eight-banded sound pressure levels by 5 dB steps from a minimum of 25 dB to a maximum of 80 dB, can be generated without volume displacement. Consequently, these sound intensities can be utilized to accurately determine the hearing threshold of a subject in the ambulatory audiometric testing environment.展开更多
基金The National Natural Science Foundation of China(No.61375028,61673108)China Postdoctoral Science Foundation(No.2016M601696)+2 种基金Qing Lan Projectthe Program for Special Talent in Six Fields of Jiangsu Province(No.2016-DZXX-023)Jiangsu Planned Projects for Postdoctoral Research Funds(No.1601011B)
文摘To promote the performance of the traditional multichannel filter bank which leads to speech quality degradation,an efficient design method of the non-uniform cosine modulated filter bank(CMFB) based on the audiogram for digital hearing aids is proposed. First, a low-pass prototype filter is designed by the linear iterative algorithm. Secondly,the uniform CMFB is achieved on the basis of the principle formulas. Then, the adjacent channels of a uniform filter bank which have low or gradual slopes are merged according to the trend of audiogram of the hearing impaired person. Finally,the corresponding non-uniform CMFB is obtained. Simulation results show that the signal processed by the proposed filter bank is similar to the original signal in a time-domain waveform and spectrogram without significant distortion or difference. The speech quality results show that the personal evaluation of speech quality(PESQ) of non-uniform CMFB is 35% higher than that of the traditional design, and the hearing-aid speech quality index(HASQI) increases by about 40%.
文摘The Vector Hydrophone(VH) is widely used to remotely detect underwater targets. Accurately measuring the self-noise of the VH provides an important basis for evaluating the performance of the detection system in which it is utilized, since the ability to acquire weak signals is determined by the VH self-noise level. To accurately measure the VH self-noise level in actual working conditions, the Dual-channel Transfer Function Method(DTFM) is proposed to reduce ambient background noise interference. In this paper, the underlying principles of DTFM in reducing ambient background noise is analyzed. The numerical simulations to determine the influence of ambient background noise, and the sensitivity difference of the two VHs on the measurement results are studied. The results of measuring the VH self-noise level in a small laboratory water tank by using DTMF indicate that ambient background noise interference can be reduced effectively by employing DTMF, more accurate self-noise level can be obtained as well. The DTMF provides an effective method for accurately measuring the self-noise level of VHs and also provides technical support for the practical application of the VH in underwater acoustics.
基金supported by the grant of the Korean Ministry of Education, Science and Technology (The Regional Core Research Program/Chungbuk BIT Research-Oriented University Consortium)
文摘An efficient calibration algorithm for an ambulatory audiometric test system is proposed. This system utilizes a personal digital assistant (PDA) device to generate the correct sound pressure level (SPL) from an audiometric transducer such as an earphone. The calibrated sound intensities for an audio-logical examination can be obtained in terms of the sound pressure levels of pure-tonal sinusoidal signals in eight-banded frequency ranges (250, 500, 1 000, 2 000, 3 000, 4 000, 6 000 and 8 000 Hz), and with mapping of the input sound pressure levels by the weight coefficients that are tuned by the delta learning rule. With this scheme, the sound intensities, which evoke eight-banded sound pressure levels by 5 dB steps from a minimum of 25 dB to a maximum of 80 dB, can be generated without volume displacement. Consequently, these sound intensities can be utilized to accurately determine the hearing threshold of a subject in the ambulatory audiometric testing environment.