Serum pancreatic tissue carcinoma antigen (PCA) was measured by ELISA in 396 patients with pancreatic carcinoma (PC) and other diseases diagnosed by clinical examination, histopathology and operation. Serum PCA more t...Serum pancreatic tissue carcinoma antigen (PCA) was measured by ELISA in 396 patients with pancreatic carcinoma (PC) and other diseases diagnosed by clinical examination, histopathology and operation. Serum PCA more than 300 U/ml was considered as diagnostic value for PC and 30-299 U/ml as probable index for PC. The sensitivity of PCA for PC was 78.2% (43/55), and the specifity 94.6%. The positive rate of PCA in other diseases were 0-13.3%. Combining the determination of PCA with B-mode ultrasonic scanning (BU). CT and/or ERCP (endos-copic retrograde cholangiopancreatography) may increase the diagnostic rate of PC to 89-91%, and with the "cocktail" of CA19-9, CEA (carcino-embryonic antigen) and RNase-C, PC be diagnosed in 88.9%. Therefore, it is suggest that PCA si a promising tumor market of PC with high sensitivity and relative specificity.展开更多
Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL...Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length.The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content,and the measurement results show the consistence with the reported results,in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line(MDL).With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed.The two-term Debye relaxation model is employed to explain our experimental results,revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules.These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology.展开更多
文摘Serum pancreatic tissue carcinoma antigen (PCA) was measured by ELISA in 396 patients with pancreatic carcinoma (PC) and other diseases diagnosed by clinical examination, histopathology and operation. Serum PCA more than 300 U/ml was considered as diagnostic value for PC and 30-299 U/ml as probable index for PC. The sensitivity of PCA for PC was 78.2% (43/55), and the specifity 94.6%. The positive rate of PCA in other diseases were 0-13.3%. Combining the determination of PCA with B-mode ultrasonic scanning (BU). CT and/or ERCP (endos-copic retrograde cholangiopancreatography) may increase the diagnostic rate of PC to 89-91%, and with the "cocktail" of CA19-9, CEA (carcino-embryonic antigen) and RNase-C, PC be diagnosed in 88.9%. Therefore, it is suggest that PCA si a promising tumor market of PC with high sensitivity and relative specificity.
基金Project supported by the National Natural Science Foundation of China(Grant No.61205101)the Shenzhen Municipal Research Foundation,China(Grant Nos.GJHZ201404171134305 and JCYJ20140417113130693)the Marie Curie Actions-International Research Staff Exchange Scheme(IRSES)(Grant No.FP7 PIRSES-2013-612267)
文摘Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length.The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content,and the measurement results show the consistence with the reported results,in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line(MDL).With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed.The two-term Debye relaxation model is employed to explain our experimental results,revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules.These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology.