Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL...Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL.展开更多
Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Result...Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs.展开更多
Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to a...Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals.展开更多
Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluati...Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluation of the extent of pneumomediastinum. We report here a case of idiopathic pneumomediastinum in a 15-year-old boy who exhibited no significant chest X-ray finding. The patient was referred to our institute for the further evaluation of pre-cordial pain and breathing difficulty. Precordial pain suddenly developed, when he was carrying a portable shrine on his shoulder (day of onset). He was admitted to another institute 3 days after onset because of worsening precordial pain. On admission, he presented with 98% saturation of hemoglobin in the peripheral blood under room air. Plain chest X-ray also revealed no abnormal findings. A half-dissolved gastrographin swallow showed no leakage of gastrographin from the pharynx and esophagus to the mediastinum, and no diverticulum within the esophagus. Plain chest CT revealed extensive emphysema around the trachea from the neck to the portion inferior to the carina of trachea. The patient was diagnosed with idiopathic pneumomediastinum because the cause was unclear. We decided to admit him to our institute under fasting conditions and rest. His symptoms improved 3 days after onset. The lesion had disap-peared 8 days after onset on chest CT. When young people experience precordial pain which increases on inspiration, we must consider pneumomediastinum in a differential diagnosis, and it is important to perform chest CT.展开更多
The real contact area(RCA)of randomly rough contacts has received a great deal of attention because it correlates strongly with friction,lubrication,sealing,and conductivity.Simulations have revealed that the RCA asso...The real contact area(RCA)of randomly rough contacts has received a great deal of attention because it correlates strongly with friction,lubrication,sealing,and conductivity.Simulations have revealed that the RCA associated with deterministic normal squeezing loads increases when tangential loads are also applied,in a phenomenon called junction growth.However,experimental investigations of the junction growth of randomly rough contacts are rare.Here,we used X-ray computed tomography(CT)to measure junction growth when two aluminum alloy surfaces were in contact.A high-resolution experimental setup was used to apply loads and observe contact behaviors at a resolution of 4μm.The RCA and average contact gaps were computed using a three-dimensional(3D)geometric model constructed from gray CT images using the Otsu thresholding method.The results showed that the RCA increased as the normal load increased.The RCA increased by 22.67%after a tangential load was applied(junction growth),and the average gap decreased by 14.01%after a tangential load was applied.Thus,X-ray CT accurately measured the junction growth as a novel quantitative method.展开更多
AIM to observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients ( 142 tumors) were enrolled into this study. Acc...AIM to observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients ( 142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group (n = 56, 65 tumors) and 64-slice group (n = 8, 77 tumors). All patients were accepted and received targeted therapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of >= 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [ hepatic artery perfusion (HAP), portal vein perfusion (PVP), and the hepatic arterial perfusion index (HAPI)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding. RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group (t = 11.445, P = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group (81.58%) was lower than that in the 64-slice group (92.86%) (chi(2) = 5.707, P = 0.017). The HAP and HAPI of tumor tissues were lower at four weeks post-treatment than at pretreatment in both groups (all P < 0.05), and those in the 64-slice group were lower than that in the dual-slice group ( all P < 0.05). HAP and PVP were lower and HAPI was higher in tumor adjacent tissues at post-treatment than at pre-treatment ( all P < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks post-treatment (all P < 0.05). Moreover, pleural effusion and intraperitoneal hemorrhage occurred in patients in the dual-slice group, while no complications occurred in the 64-slice group (all P < 0.05). CONCLUSION 64-slice spiral CT applied with cryoablation in targeted therapy for liver cancer can achieve a safe and effective freezing treatment, so it is worth being used.展开更多
The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory e...The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.展开更多
The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the ...The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.41877267 and 41877260)the Priority Research Program of the Chinese Academy of Sciences(Grant No.XDA13010201).
文摘Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL.
文摘Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs.
文摘Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals.
文摘Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluation of the extent of pneumomediastinum. We report here a case of idiopathic pneumomediastinum in a 15-year-old boy who exhibited no significant chest X-ray finding. The patient was referred to our institute for the further evaluation of pre-cordial pain and breathing difficulty. Precordial pain suddenly developed, when he was carrying a portable shrine on his shoulder (day of onset). He was admitted to another institute 3 days after onset because of worsening precordial pain. On admission, he presented with 98% saturation of hemoglobin in the peripheral blood under room air. Plain chest X-ray also revealed no abnormal findings. A half-dissolved gastrographin swallow showed no leakage of gastrographin from the pharynx and esophagus to the mediastinum, and no diverticulum within the esophagus. Plain chest CT revealed extensive emphysema around the trachea from the neck to the portion inferior to the carina of trachea. The patient was diagnosed with idiopathic pneumomediastinum because the cause was unclear. We decided to admit him to our institute under fasting conditions and rest. His symptoms improved 3 days after onset. The lesion had disap-peared 8 days after onset on chest CT. When young people experience precordial pain which increases on inspiration, we must consider pneumomediastinum in a differential diagnosis, and it is important to perform chest CT.
基金supported by the National Natural Science Foundation of China(Nos.U2141217 and 51935003)。
文摘The real contact area(RCA)of randomly rough contacts has received a great deal of attention because it correlates strongly with friction,lubrication,sealing,and conductivity.Simulations have revealed that the RCA associated with deterministic normal squeezing loads increases when tangential loads are also applied,in a phenomenon called junction growth.However,experimental investigations of the junction growth of randomly rough contacts are rare.Here,we used X-ray computed tomography(CT)to measure junction growth when two aluminum alloy surfaces were in contact.A high-resolution experimental setup was used to apply loads and observe contact behaviors at a resolution of 4μm.The RCA and average contact gaps were computed using a three-dimensional(3D)geometric model constructed from gray CT images using the Otsu thresholding method.The results showed that the RCA increased as the normal load increased.The RCA increased by 22.67%after a tangential load was applied(junction growth),and the average gap decreased by 14.01%after a tangential load was applied.Thus,X-ray CT accurately measured the junction growth as a novel quantitative method.
基金Supported by Hebei Province Health Department of Scientific Research fund project,No.20110157
文摘AIM to observe the effect of targeted therapy with 64-slice spiral computed tomography (CT) combined with cryoablation for liver cancer. METHODS A total of 124 patients ( 142 tumors) were enrolled into this study. According to the use of dual-slice spiral CT or 64-slice spiral CT as a guide technology, patients were divided into two groups: dual-slice group (n = 56, 65 tumors) and 64-slice group (n = 8, 77 tumors). All patients were accepted and received targeted therapy by an argon-helium superconducting surgery system. The guided scan times of the two groups was recorded and compared. In the two groups, the lesion ice coverage in diameter of >= 3 cm and < 3 cm were recorded, and freezing effective rate was compared. Hepatic perfusion values [ hepatic artery perfusion (HAP), portal vein perfusion (PVP), and the hepatic arterial perfusion index (HAPI)] of tumor tissues, adjacent tissues and normal liver tissues at preoperative and postoperative four weeks in the two groups were compared. Local tumor changes were recorded and efficiency was compared at four weeks post-operation. Adverse events were recorded and compared between the two groups, including fever, pain, frostbite, nausea, vomiting, pleural effusion and abdominal bleeding. RESULTS Guided scan times in the dual-slice group was longer than that in the 64-slice group (t = 11.445, P = 0.000). The freezing effective rate for tumors < 3 cm in diameter in the dual-slice group (81.58%) was lower than that in the 64-slice group (92.86%) (chi(2) = 5.707, P = 0.017). The HAP and HAPI of tumor tissues were lower at four weeks post-treatment than at pretreatment in both groups (all P < 0.05), and those in the 64-slice group were lower than that in the dual-slice group ( all P < 0.05). HAP and PVP were lower and HAPI was higher in tumor adjacent tissues at post-treatment than at pre-treatment ( all P < 0.05). Furthermore, the treatment effect and therapeutic efficacy in the dual-slice group were lower than the 64-slice group at four weeks post-treatment (all P < 0.05). Moreover, pleural effusion and intraperitoneal hemorrhage occurred in patients in the dual-slice group, while no complications occurred in the 64-slice group (all P < 0.05). CONCLUSION 64-slice spiral CT applied with cryoablation in targeted therapy for liver cancer can achieve a safe and effective freezing treatment, so it is worth being used.
基金supported by the National Natural Science Foundation of China(Grant Nos.42277150,41977219)Henan Provincial Science and Technology Research Project(Grant No.222102320271).
文摘The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks.
基金Project supported by the National Basic Research Program of China(Grant No.2012CB825800)the Science Fund for Creative Research Groups,the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant Nos.KJCX2-YW-N42 and Y4545320Y2)the National Natural Science Foundation of China(Grant Nos.11475170,11205157,11305173,11205189,11375225,11321503,11179004,and U1332109)
文摘The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution.