With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d...With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.展开更多
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr...AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.展开更多
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t...The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation.展开更多
Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is availabl...Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available. The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length, screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation. Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7, and the morphology of the cervical vertebra pedicles was reconstructed. Results Reconstructed computer tomography image data revealed that: (1) pedicle sponge width increased incrementally from C3 to C7, (2) pedicle depth was similar for C3 to C7, (3) pedicle angle decreased incrementally from 47.20~ to 33.76~ for' C3 to C7, and (4) pedicle point to midline distance was similar for C3 to C7. There were no statistical differences in morphological data between the right and the left side. Men had statistically larger values than women for all morphological parameters. Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation. The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.展开更多
Deep learning based analyses of computed tomography(CT)images contribute to automated diagnosis of COVID-19,and ensemble learning may commonly provide a better solution.Here,we proposed an ensemble learning method tha...Deep learning based analyses of computed tomography(CT)images contribute to automated diagnosis of COVID-19,and ensemble learning may commonly provide a better solution.Here,we proposed an ensemble learning method that integrates several component neural networks to jointly diagnose COVID-19.Two ensemble strategies are considered:the output scores of all component models that are combined with the weights adjusted adaptively by cost function back propagation;voting strategy.A database containing 8347 CT slices of COVID-19,common pneumonia and normal subjects was used as training and testing sets.Results show that the novel method can reach a high accuracy of 99.37%(recall:0.9981;precision:0.9893),with an increase of about 7% in comparison to single-component models.And the average test accuracy is 95.62%(recall:0.9587;precision:0.9559),with a corresponding increase of 5.2%.Compared with several latest deep learning models on the identical test set,our method made an accuracy improvement up to 10.88%.The proposed method may be a promising solution for the diagnosis of COVID-19.展开更多
AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was...AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.展开更多
Artificial Intelligence(AI)becomes one hotspot in the field of the medical images analysis and provides rather promising solution.Although some research has been explored in smart diagnosis for the common diseases of ...Artificial Intelligence(AI)becomes one hotspot in the field of the medical images analysis and provides rather promising solution.Although some research has been explored in smart diagnosis for the common diseases of urinary system,some problems remain unsolved completely A nine-layer Convolutional Neural Network(CNN)is proposed in this paper to classify the renal Computed Tomography(CT)images.Four group of comparative experiments prove the structure of this CNN is optimal and can achieve good performance with average accuracy about 92.07±1.67%.Although our renal CT data is not very large,we do augment the training data by affine,translating,rotating and scaling geometric transformation and gamma,noise transformation in color space.Experimental results validate the Data Augmentation(DA)on training data can improve the performance of our proposed CNN compared to without DA with the average accuracy about 0.85%.This proposed algorithm gives a promising solution to help clinical doctors automatically recognize the abnormal images faster than manual judgment and more accurately than previous methods.展开更多
Accurately finding the region of interest is a very vital step for segmenting organs in medical image processing.We propose a novel approach of automatically identifying region of interest in Computed Tomography Image...Accurately finding the region of interest is a very vital step for segmenting organs in medical image processing.We propose a novel approach of automatically identifying region of interest in Computed Tomography Image(CT)images based on temporal and spatial data.Our method is a 3 stages approach,1)We extract organ features from the CT images by adopting the Hounsfield filter.2)We use these filtered features and introduce our novel approach of selecting observable feature candidates by calculating contours’area and automatically detect a seed point.3)We use a novel approach to track the growing region changes across the CT image sequence in detecting region of interest,given a seed point as our input.We used quantitative and qualitative analysis to measure the accuracy against the given ground truth and our results presented a better performance than other generic approaches for automatic region of interest detection of organs in abdominal CT images.With the results presented in this research work,our proposed novel sequence approach method has been proven to be superior in terms of accuracy,automation and robustness.展开更多
This paper proposes a novel exemplar- based method for reducing noise in computed tomography (CT) images. In the proposed method, denoising is performed on each block with the help of a given database of standard im...This paper proposes a novel exemplar- based method for reducing noise in computed tomography (CT) images. In the proposed method, denoising is performed on each block with the help of a given database of standard image blocks. For each noisy block, its denoised version is the best sparse positive linear combination of the blocks in the database. We formulate the problem as a constrained optimization problem such that the solution is the denoised block. Experimental results demonstrate the good performance of the proposed method over current state-of-the-art denoising methods, in terms of both objective and subjective evaluations.展开更多
AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study i...AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study included 101 eyes of 101 children(age≤17y)with myopia.All included patients underwent comprehensive clinical examination.Optic nerve canal parameters,including disc diameter,optic nerve head(ONH)tilt angle,and border tissue angle were measured using serial enhanced-depth imaging spectral-domain optical coherence tomography(EDI-OCT).Based on the optic disc drusen consortium’s definition of PHOMS,eyes were classified as PHOMS group and non-PHOMS group.PHOMS was categorized according to height.RESULTS:Sixty-seven(66.3%)eyes were found with PHOMS.Small PHOMS could only be detected by optical coherence tomography(OCT).Medium PHOMS could be seen with blurred optic disc borders corresponding to OCT.The most frequent location of PHOMS was at the nasosuperior(91%,61 of 67 eyes)to ONH disc.The axial length and spherical equivalent were more myopic in the PHOMS group than in the non-PHOMS group(both P<0.001).ONH tilt angle was also significantly greater in PHOMS group than in non-PHOMS group[8.90(7.16-10.54)vs 3.93(3.09-5.25),P<0.001].Border tissue angle was significantly smaller in PHOMS group than in non-PHOMS group[29.70(20.90-43.81)vs 45.62(35.18-60.45),P<0.001].In the multivariable analysis,spherical equivalent(OR=3.246,95%CI=1.209-8.718,P=0.019)and ONH tilt angle(OR=3.275,95%CI=1.422-7.542,P=0.005)were significantly correlated with PHOMS.There was no disc diameter associated with PHOMS.In the linear regression analysis,border tissue angle was negatively associated with PHOMS height(β=-2.227,P<0.001).CONCLUSION:PHOMS is associated with optic disc tilt and optic disc nasal shift in myopia.Disc diameter is not a risk factor for PHOMS.The changes in ONH caused by axial elongation facilitated an understanding of the mechanism of PHOMS.展开更多
Objectives: This study aims to evaluate the level of X-ray doses used in childhood’s head as Local Diagnostic Reference Levels (LDRLs) in computed tomography (CT) at a university hospital in Côte d’Ivoire. The ...Objectives: This study aims to evaluate the level of X-ray doses used in childhood’s head as Local Diagnostic Reference Levels (LDRLs) in computed tomography (CT) at a university hospital in Côte d’Ivoire. The Diagnostic Reference Level (DRL) have been set up and used to prevent unusually high radiation doses used in radiology departments and is therefore an optimization tool for practices and procedures in medical X-ray imaging for the radiation protection of patients. Methods: A prospective study of volume CT dose index (CTDI<sub>vol</sub>) and dose length product (DLP) was performed on images of childhood’s head obtained from a CT-scanner of 64 bars equipped with the tube current modulation capability and manufactured by Hitachi Medical System. 122 CT-scan data from 55 childhood’s head were analyzed. The scan data were stratified in four age groups: Results: The 75th percentile of CTDI<sub>vol</sub> and DLP (set as LDRL) obtained with respect to the stratified age groups are: 22.5 mGy and 452.5 mGy∙cm, 27.7 mGy and 690.6 mGy∙cm, 28 mGy and 722.4 mGy∙cm, 33.6 mGy and 736.8 mGy∙cm respectively. These outcome values increase with respect to the age of pediatric patients and are comparable to DRLs values obtained internationally. Conclusions: Obtaining good image quality while using low dose in children’s head computed tomography for radiation protection require to setup more surveys in Côte d’Ivoire for regional and national DRL. We proposed through this survey LDRLs in terms of CTDI<sub>vol</sub> and DLP, comparable to international DRLs values. This survey will be strengthened by additional surveys in order to obtain national DRLs for the radiation protection of the child patient in Côte d’Ivoire.展开更多
BACKGROUND Computed tomography(CT),liver stiffness measurement(LSM),and magnetic resonance imaging(MRI)are non-invasive diagnostic methods for esophageal varices(EV)and for the prediction of high-bleeding-risk EV(HREV...BACKGROUND Computed tomography(CT),liver stiffness measurement(LSM),and magnetic resonance imaging(MRI)are non-invasive diagnostic methods for esophageal varices(EV)and for the prediction of high-bleeding-risk EV(HREV)in cirrhotic patients.However,the clinical use of these methods is controversial.AIM To evaluate the accuracy of LSM,CT,and MRI in diagnosing EV and predicting HREV in cirrhotic patients.METHODS We performed literature searches in multiple databases,including Pub Med,Embase,Cochrane,CNKI,and Wanfang databases,for articles that evaluated the accuracy of LSM,CT,and MRI as candidates for the diagnosis of EV and prediction of HREV in cirrhotic patients.Summary sensitivity and specificity,positive likelihood ratio and negative likelihood ratio,diagnostic odds ratio,and the areas under the summary receiver operating characteristic curves were analyzed.The quality of the articles was assessed using the quality assessment of diagnostic accuracy studies-2 tool.Heterogeneity was examined by Q-statistic test and I2 index,and sources of heterogeneity were explored using metaregression and subgroup analysis.Publication bias was evaluated using Deek’s funnel plot.All statistical analyses were conducted using Stata12.0,Meta Disc1.4,and Rev Man5.3.RESULTS Overall,18,17,and 7 relevant articles on the accuracy of LSM,CT,and MRI in evaluating EV and HREV were retrieved.A significant heterogeneity was observed in all analyses(P<0.05).The areas under the summary receiver operating characteristic curves of LSM,CT,and MRI in diagnosing EV and predicting HREV were 0.86(95%confidence interval[CI]:0.83-0.89),0.91(95%CI:0.88-0.93),and 0.86(95%CI:0.83-0.89),and 0.85(95%CI:0.81-0.88),0.94(95%CI:0.91-0.96),and 0.83(95%CI:0.79-0.86),respectively,with sensitivities of 0.84(95%CI:0.78-0.89),0.91(95%CI:0.87-0.94),and 0.81(95%CI:0.76-0.86),and 0.81(95%CI:0.75-0.86),0.88(95%CI:0.82-0.92),and 0.80(95%CI:0.72-0.86),and specificities of 0.71(95%CI:0.60-0.80),0.75(95%CI:0.68-0.82),and 0.82(95%CI:0.70-0.89),and 0.73(95%CI:0.66-0.80),0.87(95%CI:0.81-0.92),and 0.72(95%CI:0.62-0.80),respectively.The corresponding positive likelihood ratios were 2.91,3.67,and 4.44,and 3.04,6.90,and2.83;the negative likelihood ratios were 0.22,0.12,and 0.23,and 0.26,0.14,and 0.28;the diagnostic odds ratios were 13.01,30.98,and 19.58,and 11.93,49.99,and 10.00.CT scanner is the source of heterogeneity.There was no significant difference in diagnostic threshold effects(P>0.05)or publication bias(P>0.05).CONCLUSION Based on the meta-analysis of observational studies,it is suggested that CT imaging,a non-invasive diagnostic method,is the best choice for the diagnosis of EV and prediction of HREV in cirrhotic patients compared with LSM and MRI.展开更多
Inflammatory fibroid polyp(IFP) is a rare benign lesion of the gastrointestinal tract. We report a case of computed tomography(CT) imaging finding of a gastric IFP with massive fibrosis. CT scans showed thickening of ...Inflammatory fibroid polyp(IFP) is a rare benign lesion of the gastrointestinal tract. We report a case of computed tomography(CT) imaging finding of a gastric IFP with massive fibrosis. CT scans showed thickening of submucosal layer with overlying mucosal hyperenhancement in the gastric antrum. The submucosal layer showed increased enhancement on delayed phase imaging. An antrectomy with gastroduodenostomy was performed because gastric cancer was suspected, particularly signet ring cell carcinoma. The histopathological diagnosis was an IFP with massive fibrosis. The authors suggest that when the submucosal layer of the gastric wall is markedly thickened with delayed enhancement and preservation of the mucosal layer, an IFP with massive fibrosis should be considered in the differential diagnosis.展开更多
Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic al...Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate.展开更多
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ...Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.展开更多
Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence ...Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence tomography(OCT) image. First, ATVR is introduced into the cost function of NAS-RIF to improve the noise robustness and retain the details in the image.Since the split Bregman iterative is used to optimize the ATVR based cost function, the ATVR based NAS-RIF blind restoration method is then constructed. Furthermore, combined with the geometric nonlinear diffusion filter and the Poisson-distribution-based minimum error thresholding, the ATVR based NAS-RIF blind restoration method is used to realize the blind OCT image restoration. The experimental results demonstrate that the ATVR based NAS-RIF blind restoration method can successfully retain the details in the OCT images. In addition, the signal-to-noise ratio of the blind restored OCT images can be improved, along with the noise robustness.展开更多
AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical c...AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.展开更多
AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT)...AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.展开更多
Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) a...Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.展开更多
Imaging has a central role in the context of focal therapy(FT)for prostate cancer(PCa).Prostate-specific membrane antigen(PSMA)positron emission tomography/magnetic resonance imaging(PET/MRI)is a novel imaging modalit...Imaging has a central role in the context of focal therapy(FT)for prostate cancer(PCa).Prostate-specific membrane antigen(PSMA)positron emission tomography/magnetic resonance imaging(PET/MRI)is a novel imaging modality that combines the morpho-functional information of MRI with the molecular characterization of PET.Some papers reported the potential advantages of PSMA PET/MRI in different clinical scenarios.Limited evidence on PSMA PET/MRI is available in the setting of FT.PSMA PET/MRI can be an effective imaging modality for detecting primary PCa and seems to provide accurate local staging of primary PCa.PSMA PET/MRI also shows high performance for restaging and detecting tumor recurrence.The higher soft-tissue contrast and the reduction of ionizing radiation are the main advantages reported in the literature compared to PET/computed tomography.PSMA PET/MRI could represent a turning point in the management of patients with PCa in the context of FT.Further studies are needed to confirm its applications in this specific clinical setting.展开更多
基金Project supported by the National Basic Research Program of China(Grant No.2006CB7057005)the National High Technology Research and Development Program of China(Grant No.2009AA012200)the National Natural Science Foundation of China (Grant No.60672104)
文摘With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.
文摘AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.
基金Project supported by the National Natural Science Foundation of China(Grant No.61372172)
文摘The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation.
文摘Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation, and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available. The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length, screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation. Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7, and the morphology of the cervical vertebra pedicles was reconstructed. Results Reconstructed computer tomography image data revealed that: (1) pedicle sponge width increased incrementally from C3 to C7, (2) pedicle depth was similar for C3 to C7, (3) pedicle angle decreased incrementally from 47.20~ to 33.76~ for' C3 to C7, and (4) pedicle point to midline distance was similar for C3 to C7. There were no statistical differences in morphological data between the right and the left side. Men had statistically larger values than women for all morphological parameters. Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation. The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.
基金the Sichuan Science and Technology Department Research and Development Key Project(No.21ZDYF3607)the Weining Cloud Hospital Based AI Medical Software System Service and Demo Project(No.2019K0JTS0159)the China Postdoctoral Science Foundation(No.2020T130137ZX)。
文摘Deep learning based analyses of computed tomography(CT)images contribute to automated diagnosis of COVID-19,and ensemble learning may commonly provide a better solution.Here,we proposed an ensemble learning method that integrates several component neural networks to jointly diagnose COVID-19.Two ensemble strategies are considered:the output scores of all component models that are combined with the weights adjusted adaptively by cost function back propagation;voting strategy.A database containing 8347 CT slices of COVID-19,common pneumonia and normal subjects was used as training and testing sets.Results show that the novel method can reach a high accuracy of 99.37%(recall:0.9981;precision:0.9893),with an increase of about 7% in comparison to single-component models.And the average test accuracy is 95.62%(recall:0.9587;precision:0.9559),with a corresponding increase of 5.2%.Compared with several latest deep learning models on the identical test set,our method made an accuracy improvement up to 10.88%.The proposed method may be a promising solution for the diagnosis of COVID-19.
基金Supported by National Natural Science Foundation of China(No.81300805)。
文摘AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.
基金This study was supported by National Educational Science Plan Foundation“in 13th Five-Year”(DIA170375),ChinaGuangxi Key Laboratory of Trusted Software(kx201901)British Heart Foundation Accelerator Award,UK.
文摘Artificial Intelligence(AI)becomes one hotspot in the field of the medical images analysis and provides rather promising solution.Although some research has been explored in smart diagnosis for the common diseases of urinary system,some problems remain unsolved completely A nine-layer Convolutional Neural Network(CNN)is proposed in this paper to classify the renal Computed Tomography(CT)images.Four group of comparative experiments prove the structure of this CNN is optimal and can achieve good performance with average accuracy about 92.07±1.67%.Although our renal CT data is not very large,we do augment the training data by affine,translating,rotating and scaling geometric transformation and gamma,noise transformation in color space.Experimental results validate the Data Augmentation(DA)on training data can improve the performance of our proposed CNN compared to without DA with the average accuracy about 0.85%.This proposed algorithm gives a promising solution to help clinical doctors automatically recognize the abnormal images faster than manual judgment and more accurately than previous methods.
基金This work was supported by the National Natural Science Foundation of China(Nos.61772242,61572239,61402204)Research Fund for Advanced Talents of Jiangsu University(14JDG141)+2 种基金Qing Lan ProjectChina Postdoctoral Science Foundation(No.2017M611737)Zhenjiang social development project(SH2016029).
文摘Accurately finding the region of interest is a very vital step for segmenting organs in medical image processing.We propose a novel approach of automatically identifying region of interest in Computed Tomography Image(CT)images based on temporal and spatial data.Our method is a 3 stages approach,1)We extract organ features from the CT images by adopting the Hounsfield filter.2)We use these filtered features and introduce our novel approach of selecting observable feature candidates by calculating contours’area and automatically detect a seed point.3)We use a novel approach to track the growing region changes across the CT image sequence in detecting region of interest,given a seed point as our input.We used quantitative and qualitative analysis to measure the accuracy against the given ground truth and our results presented a better performance than other generic approaches for automatic region of interest detection of organs in abdominal CT images.With the results presented in this research work,our proposed novel sequence approach method has been proven to be superior in terms of accuracy,automation and robustness.
文摘This paper proposes a novel exemplar- based method for reducing noise in computed tomography (CT) images. In the proposed method, denoising is performed on each block with the help of a given database of standard image blocks. For each noisy block, its denoised version is the best sparse positive linear combination of the blocks in the database. We formulate the problem as a constrained optimization problem such that the solution is the denoised block. Experimental results demonstrate the good performance of the proposed method over current state-of-the-art denoising methods, in terms of both objective and subjective evaluations.
基金Supported by Wuhan Central Hospital Discipline Fund(No.2021XK017).
文摘AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study included 101 eyes of 101 children(age≤17y)with myopia.All included patients underwent comprehensive clinical examination.Optic nerve canal parameters,including disc diameter,optic nerve head(ONH)tilt angle,and border tissue angle were measured using serial enhanced-depth imaging spectral-domain optical coherence tomography(EDI-OCT).Based on the optic disc drusen consortium’s definition of PHOMS,eyes were classified as PHOMS group and non-PHOMS group.PHOMS was categorized according to height.RESULTS:Sixty-seven(66.3%)eyes were found with PHOMS.Small PHOMS could only be detected by optical coherence tomography(OCT).Medium PHOMS could be seen with blurred optic disc borders corresponding to OCT.The most frequent location of PHOMS was at the nasosuperior(91%,61 of 67 eyes)to ONH disc.The axial length and spherical equivalent were more myopic in the PHOMS group than in the non-PHOMS group(both P<0.001).ONH tilt angle was also significantly greater in PHOMS group than in non-PHOMS group[8.90(7.16-10.54)vs 3.93(3.09-5.25),P<0.001].Border tissue angle was significantly smaller in PHOMS group than in non-PHOMS group[29.70(20.90-43.81)vs 45.62(35.18-60.45),P<0.001].In the multivariable analysis,spherical equivalent(OR=3.246,95%CI=1.209-8.718,P=0.019)and ONH tilt angle(OR=3.275,95%CI=1.422-7.542,P=0.005)were significantly correlated with PHOMS.There was no disc diameter associated with PHOMS.In the linear regression analysis,border tissue angle was negatively associated with PHOMS height(β=-2.227,P<0.001).CONCLUSION:PHOMS is associated with optic disc tilt and optic disc nasal shift in myopia.Disc diameter is not a risk factor for PHOMS.The changes in ONH caused by axial elongation facilitated an understanding of the mechanism of PHOMS.
文摘Objectives: This study aims to evaluate the level of X-ray doses used in childhood’s head as Local Diagnostic Reference Levels (LDRLs) in computed tomography (CT) at a university hospital in Côte d’Ivoire. The Diagnostic Reference Level (DRL) have been set up and used to prevent unusually high radiation doses used in radiology departments and is therefore an optimization tool for practices and procedures in medical X-ray imaging for the radiation protection of patients. Methods: A prospective study of volume CT dose index (CTDI<sub>vol</sub>) and dose length product (DLP) was performed on images of childhood’s head obtained from a CT-scanner of 64 bars equipped with the tube current modulation capability and manufactured by Hitachi Medical System. 122 CT-scan data from 55 childhood’s head were analyzed. The scan data were stratified in four age groups: Results: The 75th percentile of CTDI<sub>vol</sub> and DLP (set as LDRL) obtained with respect to the stratified age groups are: 22.5 mGy and 452.5 mGy∙cm, 27.7 mGy and 690.6 mGy∙cm, 28 mGy and 722.4 mGy∙cm, 33.6 mGy and 736.8 mGy∙cm respectively. These outcome values increase with respect to the age of pediatric patients and are comparable to DRLs values obtained internationally. Conclusions: Obtaining good image quality while using low dose in children’s head computed tomography for radiation protection require to setup more surveys in Côte d’Ivoire for regional and national DRL. We proposed through this survey LDRLs in terms of CTDI<sub>vol</sub> and DLP, comparable to international DRLs values. This survey will be strengthened by additional surveys in order to obtain national DRLs for the radiation protection of the child patient in Côte d’Ivoire.
基金Supported by the State Key Projects Specialized on Infectious Diseases,No.2017ZX10203202–004Beijing Municipal Administration of Hospitals Clinical Medicine Development of Special Funding,No.ZYLX201610+1 种基金Beijing Municipal Administration of Hospitals’Ascent Plan,No.DFL20151602Digestive Medical Coordinated Development Center of Beijing Hospitals Authority,No.XXT24.
文摘BACKGROUND Computed tomography(CT),liver stiffness measurement(LSM),and magnetic resonance imaging(MRI)are non-invasive diagnostic methods for esophageal varices(EV)and for the prediction of high-bleeding-risk EV(HREV)in cirrhotic patients.However,the clinical use of these methods is controversial.AIM To evaluate the accuracy of LSM,CT,and MRI in diagnosing EV and predicting HREV in cirrhotic patients.METHODS We performed literature searches in multiple databases,including Pub Med,Embase,Cochrane,CNKI,and Wanfang databases,for articles that evaluated the accuracy of LSM,CT,and MRI as candidates for the diagnosis of EV and prediction of HREV in cirrhotic patients.Summary sensitivity and specificity,positive likelihood ratio and negative likelihood ratio,diagnostic odds ratio,and the areas under the summary receiver operating characteristic curves were analyzed.The quality of the articles was assessed using the quality assessment of diagnostic accuracy studies-2 tool.Heterogeneity was examined by Q-statistic test and I2 index,and sources of heterogeneity were explored using metaregression and subgroup analysis.Publication bias was evaluated using Deek’s funnel plot.All statistical analyses were conducted using Stata12.0,Meta Disc1.4,and Rev Man5.3.RESULTS Overall,18,17,and 7 relevant articles on the accuracy of LSM,CT,and MRI in evaluating EV and HREV were retrieved.A significant heterogeneity was observed in all analyses(P<0.05).The areas under the summary receiver operating characteristic curves of LSM,CT,and MRI in diagnosing EV and predicting HREV were 0.86(95%confidence interval[CI]:0.83-0.89),0.91(95%CI:0.88-0.93),and 0.86(95%CI:0.83-0.89),and 0.85(95%CI:0.81-0.88),0.94(95%CI:0.91-0.96),and 0.83(95%CI:0.79-0.86),respectively,with sensitivities of 0.84(95%CI:0.78-0.89),0.91(95%CI:0.87-0.94),and 0.81(95%CI:0.76-0.86),and 0.81(95%CI:0.75-0.86),0.88(95%CI:0.82-0.92),and 0.80(95%CI:0.72-0.86),and specificities of 0.71(95%CI:0.60-0.80),0.75(95%CI:0.68-0.82),and 0.82(95%CI:0.70-0.89),and 0.73(95%CI:0.66-0.80),0.87(95%CI:0.81-0.92),and 0.72(95%CI:0.62-0.80),respectively.The corresponding positive likelihood ratios were 2.91,3.67,and 4.44,and 3.04,6.90,and2.83;the negative likelihood ratios were 0.22,0.12,and 0.23,and 0.26,0.14,and 0.28;the diagnostic odds ratios were 13.01,30.98,and 19.58,and 11.93,49.99,and 10.00.CT scanner is the source of heterogeneity.There was no significant difference in diagnostic threshold effects(P>0.05)or publication bias(P>0.05).CONCLUSION Based on the meta-analysis of observational studies,it is suggested that CT imaging,a non-invasive diagnostic method,is the best choice for the diagnosis of EV and prediction of HREV in cirrhotic patients compared with LSM and MRI.
文摘Inflammatory fibroid polyp(IFP) is a rare benign lesion of the gastrointestinal tract. We report a case of computed tomography(CT) imaging finding of a gastric IFP with massive fibrosis. CT scans showed thickening of submucosal layer with overlying mucosal hyperenhancement in the gastric antrum. The submucosal layer showed increased enhancement on delayed phase imaging. An antrectomy with gastroduodenostomy was performed because gastric cancer was suspected, particularly signet ring cell carcinoma. The histopathological diagnosis was an IFP with massive fibrosis. The authors suggest that when the submucosal layer of the gastric wall is markedly thickened with delayed enhancement and preservation of the mucosal layer, an IFP with massive fibrosis should be considered in the differential diagnosis.
基金supported by the National Natural Science Foundation of China (No.11264032)the Aeronautical Science Foundation of China (No.2014ZD56007)+4 种基金the Science and Technology Project of General Administration of Quality Supervision,Inspection and Quarantine of China (No.2013zjjz180)the Natural Science Foundation of Jiangxi Province (No.20122BAB201024)the Science and Technology Project of the Education Department of Jiangxi Province (No.GJJ14530)the Innovation Foundation of Shanghai Aerospace(SAST201364)the Graduate Innovation Foundation of Nanchang Hangkong University (No.YC2013010)
文摘Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate.
基金Supported by the Hundred Talents Program of Chinese Academy of Sciencesthe National Basic Research Program of China under Grant No 2014CB339803+2 种基金the Major National Development Project of Scientific Instrument and Equipment under Grant No2011YQ150021the National Natural Science Foundation of China under Grant Nos 61575214,61574155,61404149 and 61404150the Shanghai Municipal Commission of Science and Technology under Grant Nos 14530711300,15560722000 and 15ZR1447500
文摘Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.
基金Supported by National Key Research and Development Program of China(2016YFF0201005)。
文摘Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence tomography(OCT) image. First, ATVR is introduced into the cost function of NAS-RIF to improve the noise robustness and retain the details in the image.Since the split Bregman iterative is used to optimize the ATVR based cost function, the ATVR based NAS-RIF blind restoration method is then constructed. Furthermore, combined with the geometric nonlinear diffusion filter and the Poisson-distribution-based minimum error thresholding, the ATVR based NAS-RIF blind restoration method is used to realize the blind OCT image restoration. The experimental results demonstrate that the ATVR based NAS-RIF blind restoration method can successfully retain the details in the OCT images. In addition, the signal-to-noise ratio of the blind restored OCT images can be improved, along with the noise robustness.
基金Supported by Wenzhou Municipal Science and Technology Bureau(No.Y20150257)
文摘AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.
基金Supported by Major Scientific and Technological Projects in Zhejiang Province,China(No.2013c03048-3)the Science and Technology Plan Project of Wenzhou Science and Technology Bureau(No.Y20150284)Medical Scientific Research Foundation of Zhejiang Province(No.2016ZDA016)
文摘AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.
基金Project(61171133)supported by the National Natural Science Foundation of ChinaProject(11JJ1010)supported by the Natural Science Fund for Distinguished Young Scholars of Hunan Province,ChinaProject(61101182)supported by the National Natural Science Foundation for Young Scientists of China
文摘Inverse synthetic aperture radar(ISAR) imaging can be regarded as a narrow-band version of the computer aided tomography(CT). The traditional CT imaging algorithms for ISAR, including the polar format algorithm(PFA) and the convolution back projection algorithm(CBP), usually suffer from the problem of the high sidelobe and the low resolution. The ISAR tomography image reconstruction within a sparse Bayesian framework is concerned. Firstly, the sparse ISAR tomography imaging model is established in light of the CT imaging theory. Then, by using the compressed sensing(CS) principle, a high resolution ISAR image can be achieved with limited number of pulses. Since the performance of existing CS-based ISAR imaging algorithms is sensitive to the user parameter, this makes the existing algorithms inconvenient to be used in practice. It is well known that the Bayesian formalism of recover algorithm named sparse Bayesian learning(SBL) acts as an effective tool in regression and classification,which uses an efficient expectation maximization procedure to estimate the necessary parameters, and retains a preferable property of the l0-norm diversity measure. Motivated by that, a fully automated ISAR tomography imaging algorithm based on SBL is proposed.Experimental results based on simulated and electromagnetic(EM) data illustrate the effectiveness and the superiority of the proposed algorithm over the existing algorithms.
文摘Imaging has a central role in the context of focal therapy(FT)for prostate cancer(PCa).Prostate-specific membrane antigen(PSMA)positron emission tomography/magnetic resonance imaging(PET/MRI)is a novel imaging modality that combines the morpho-functional information of MRI with the molecular characterization of PET.Some papers reported the potential advantages of PSMA PET/MRI in different clinical scenarios.Limited evidence on PSMA PET/MRI is available in the setting of FT.PSMA PET/MRI can be an effective imaging modality for detecting primary PCa and seems to provide accurate local staging of primary PCa.PSMA PET/MRI also shows high performance for restaging and detecting tumor recurrence.The higher soft-tissue contrast and the reduction of ionizing radiation are the main advantages reported in the literature compared to PET/computed tomography.PSMA PET/MRI could represent a turning point in the management of patients with PCa in the context of FT.Further studies are needed to confirm its applications in this specific clinical setting.