AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric pan...AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric panniculitis from January 2005 to August 2010 were identified in the Radnet(Rad Net Corporation, Los Angeles, CA) database. Patients with a new or known diagnosis of a malignancy were included for this analysis. Longitudinal clinical histories were obtained from electronic medical records.RESULTS In total, 147794 abdominal CT scans were performed during the study period. Three hundred and fiftynine patients had mesenteric panniculitis(MP)-like abnormalities on their abdominal CT. Of these patients, 81 patients(22.6%) had a known history of cancer at the time of their CT scan. Nineteen(5.3%) had a new diagnosis of cancer in concurrence with their CT, but the majority of these(14/19, 74%) were undergoing CT as part of a malignancy evaluation. Lymphomas were the most common cancers associated with MPlike findings on CT(36 cases, 36%), with follicular lymphoma being the most frequent subtype(17/36). A variety of solid tumors, most commonly prostate(7) and renal cell cancers(6) also were seen. CT follow up was obtained in 56 patients. Findings in the mesentery were unchanged in 45(80%), worsened in 6(11%), and improved in 5 patients(9%). Positron emission tomography(PET) scans performed in 44 patients only showed a positive uptake in the mesenteric mass in 2 patients(5%). CONCLUSION A new diagnosis of cancer is uncommon in patients with CT findings suggestive of MP. MP-like mesenteric abnormalities on CT generally remain stable in patients with associated malignancies. PET scanning is not recommended in the evaluation of patients with mesenteric panniculitis-like findings on CT.展开更多
Background: In 2010, the International Atomic Energy Agency launched the “3A’s campaign” as an effective tool for primary cancer prevention. In 2011, the American Association of Physicists in Medicine recommended t...Background: In 2010, the International Atomic Energy Agency launched the “3A’s campaign” as an effective tool for primary cancer prevention. In 2011, the American Association of Physicists in Medicine recommended the size specific dose estimate (SSDE). Objectives: To audit doses of Coronary CT Angiography (Coronary CTA) in tertiary care referral center. Methods: We reviewed 998 consecutive Coronary CTA (from 2007 to 2012). Doses (CTDIvol mGy), DLP (mGy*cm), effective dose (DLP*0.014, mSv) were on-line archived. SSDE was estimated retrospectively. Appropriateness score was evaluated for exams performed from the 2010. Results: Overall median dose per Coronary CTA was 49.7 mGy for CTDIvol, 55.5 mGy for SSDE, 994.96 mGy*cm for DLP, 13.9 mSv for effective dose. Median DLP decreased over time (1452.94 in 2007, 1605.56 in 2008, 1113.49 in 2009, 759.99 in 2010, 448.61 in 2011 and 497.88 mGy*cm in 2012, p < 0.0001). SSDE was proportional to the size dependent factor (SDF);in patients with SDF > 1 (88%) CTDIvol underestimated SSDE (48.49 vs 57.19 mGy), whilst in patients with SDF < 1 (12%) CTDIvol overestimated SSDE (56.46 vs 50.3 mGy). Scans were appropriate in 58%, uncertain in 24%, and inappropriate in 18% of cases. Doses were similar in appropriate, uncertain or inappropriate examinations and in excellent-to-good (81%) vs. sufficient-to-poor (19%) image quality exams. Conclusions: Coronary CTA reference doses can be very misleading. SSDE can allow individual technique optimization. The dose is similar in appropriate and inappropriate examinations, and unrelated to image quality. The rate of inappropriate examinations is still too high even after dissemination of guidelines.展开更多
Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intraco...Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intracoronary ultrasound studies revealed sharp differences in the plaque morphology between patients with acute versus chronic coronary syndromes. Whether there are different patterns of coronary artery calcification in patients with stable angina pectoris (SAP) and in those with unstable angina pectoris (UAP) or acute myocardial infarction (AMI), however, remains unclear. Methods Two hundred and sixty - four patients, including 67 with SAP, 94 with UAP and 103 with AMI were studied with electron beam computed tomography for analysis of coronary artery calcification and with selective coronary angiography for determination of atherosclerotic lesions. CAC prevalence and calcium score were compared among three groups, and relation of CAC to the severity of atherosclerotic disease in the SAP and UAP patients was separately analyzed. Results Prevalence of CAC was 100 % in the SAP patients, significantly higher than the 87. 23 % in UAP patients and 86. 41 % among the patients with AMI ( P < 0. 05) . More patients and arteries in the SAP group had severe forms of calcium than those in the UAP and AMI group ( P < 0. 01), and the mean LN [CS + 1] (natural logarithm transformation of calcium score) of the SAP patients was much greater than that of the UAP and AMI patients (P < 0.001). The distribution of vessels with various CAC by luminal stenosis was different between SAP and UAP patients. The average CAC extent of the infarct - related arteries was less severe than that of the noninfarct - related arteries. Conclusions U-tilizing electron beam computed tomography, we demonstrated that there exist different patterns of coronary artery calcification in patients with acute versus chronic coronary syndromes, which may provide insight into the differences observed in the clinical and pathologic development between these two types of coronary artery disease.展开更多
A tomography device based on a conventional laboratory x ray source, polycapillary parallel x ray lens (PPXRL), and polycapillary collimating x ray lens (PCXRL) is designed. The PPXRL can collect the divergent x r...A tomography device based on a conventional laboratory x ray source, polycapillary parallel x ray lens (PPXRL), and polycapillary collimating x ray lens (PCXRL) is designed. The PPXRL can collect the divergent x ray beam from the source and focus it into a quasi-parallel x ray beam with a divergence of 4.7 rarad. In the center of quasi-parallel x ray beam, there is a plateau region with an average gain in power density of 13.8 and a diameter of 630μm. The contrast of the image can be improved from 28.9% to 56.0% after adding the PCXRL between the sample and the detector.展开更多
A new type of solid-conversion gas detector is investigated for high energy X-ray industrial computed tomography (HECT). The conversion efficiency is calculated by using the EGSnrc Monte Carlo code on the Linux platfo...A new type of solid-conversion gas detector is investigated for high energy X-ray industrial computed tomography (HECT). The conversion efficiency is calculated by using the EGSnrc Monte Carlo code on the Linux platform to simulate the transport process of photons and electrons in the detector. The simulation results show that the conversion efficiency could be more than 65%, if the X-ray beam width is less than about 0.2 mm, and a tungsten slab with 0.2 mm thickness and 30 mm length is employed as a radiation conversion medium. Meanwhile the results indicate that this new detector has higher conversion efficiency as well as less volume. Theoretically this new kind of detector could take place of the traditional scintillation detector for HECT.展开更多
The process of constructing a database of average cross-sections in Chinese proximal femurs is described. The main goal of creating the database is for designing hip stems for Chinese patients. Methods for constructin...The process of constructing a database of average cross-sections in Chinese proximal femurs is described. The main goal of creating the database is for designing hip stems for Chinese patients. Methods for constructing the database are introduced. According to some existing software and programs developed by the authors, a database of average cross-sections in Chinese proximal femurs was built based on CT images of eighty femur-specimens. 3-D shape of a patient's proximal femurs can be reconstructed according to the database and X-ray radiographs. Theoretical analyses and results of clinical application indicate that the database can be used to design hip stems for Chinese patients.展开更多
Objectives To evaluate the ability of CT pleurography (CTP) in detecting minor pleural lesions in patients with pleural effusion and to assess its value in distinguishing malignant from benign pleural lesions. Method...Objectives To evaluate the ability of CT pleurography (CTP) in detecting minor pleural lesions in patients with pleural effusion and to assess its value in distinguishing malignant from benign pleural lesions. Methods A prospective study of 50 patients with pleural effusion was conducted using conventional CT and CTP. CT scan was run after injecting an appropriate amount of contrast medium into the pleural cavity. Results In 24 patients, all lesions detected by conventional CT were demonstrated by CTP. In 13 of 24 patients, CT pleurography detected additional lesions. In 20 of 26 patients with negative findings on conventional CT, CTP was capable of demonstrating the presence of pleural lesions. The sensitivity, specificity and accuracy of detecting pleural lesions were 25%, 100% and 30% for conventional CT, 86%, 100% and 87% for CTP, respectively. Conclusion CTP is superior to conventional CT in detecting and for the differential diagnosis benign and malignant pleural lesions.展开更多
随着鼻窦CT诊断和鼻内镜诊疗技术的发展,大量鼻部疾病导致的头痛得以治愈。根据2004年国际头痛协会的分类,鼻源性头痛的第二种类型——黏膜接触点性头痛(mucosa contact point headache),因为缺少典型的鼻部症状,而分散就诊于其...随着鼻窦CT诊断和鼻内镜诊疗技术的发展,大量鼻部疾病导致的头痛得以治愈。根据2004年国际头痛协会的分类,鼻源性头痛的第二种类型——黏膜接触点性头痛(mucosa contact point headache),因为缺少典型的鼻部症状,而分散就诊于其他学科,长期得不到合理诊疗。我们近期总结了多例临床上没有典型的鼻部症状,而是以各种类型的头痛为主诉就诊于神经内科等专科的患者,经过会诊筛查,确诊为鼻源性黏膜接触点性头痛,通过鼻内镜手术治愈。其中包括1组女性患者,长期被误认为是月经前期头痛,通过治疗证明是黏膜接触点性头痛的一种特殊存在形式,撰文总结如下。展开更多
Objective: To develop and validate a computed tomography(CT)-based radiomics nomogram for predicting human epidermal growth factor receptor 2(HER2) status in patients with gastric cancer.Methods: This retrospective st...Objective: To develop and validate a computed tomography(CT)-based radiomics nomogram for predicting human epidermal growth factor receptor 2(HER2) status in patients with gastric cancer.Methods: This retrospective study included 134 patients with gastric cancer(HER2-negative: n=87;HER2-positive: n=47) from April 2013 to March 2018, who were then randomly divided into training(n=94) and validation(n=40) cohorts. Radiomics features were obtained from the CT images showing gastric cancer. Least absolute shrinkage and selection operator(LASSO) regression analysis was utilized for building the radiomics signature. A multivariable logistic regression method was applied to develop a prediction model incorporating the radiomics signature and independent clinicopathologic risk predictors, which were then visualized as a radiomics nomogram. The predictive performance of the nomogram was assessed in the training and validation cohorts.Results: The radiomics signature was significantly associated with HER2 status in both training(P<0.001) and validation(P=0.023) cohorts. The prediction model that incorporated the radiomics signature and carcinoembryonic antigen(CEA) level demonstrated good discriminative performance for HER2 status prediction,with an area under the curve(AUC) of 0.799 [95% confidence interval(95% CI): 0.704-0.894] in the training cohort and 0.771(95% CI: 0.607-0.934) in the validation cohort. The calibration curve of the radiomics nomogram also showed good calibration. Decision curve analysis showed that the radiomics nomogram was useful.Conclusions: We built and validated a radiomics nomogram with good performance for HER2 status prediction in gastric cancer. This radiomics nomogram could serve as a non-invasive tool to predict HER2 status and guide clinical treatment.展开更多
AIM To recognize the characteristic findings of non pathologic perfusion defects with CT arterial portography (CTAP) and nonpathologic enhancement found in CT hepatic arteriography (CTHA). METHODS The manifestatio...AIM To recognize the characteristic findings of non pathologic perfusion defects with CT arterial portography (CTAP) and nonpathologic enhancement found in CT hepatic arteriography (CTHA). METHODS The manifestations of nonpathologic perfusion defects with CTAP and non pathologic enhancement found in CTHA were analyzed in 50 patients with primary hepatocellular carcinoma. RESULTS The false positive rate of perfusion defects detected in CTAP was 15 1%. The shapes of perfusion defects were peripheral wedge, small, round, and patchy. The occurrence rate of non pathologic enhancement found in CTHA was 22 0%. The shapes of non pathologic enhancement were small, round, irregular, and wedge. CONCLUSION There was a high frequency of non pathologic perfusion defects detected with CTAP and non pathologic enhancement found in CTHA. The simultaneous use of both procedures may help decrease the false positive rate, and increase the veracity of diagnosis for hepatocellular carcinoma.展开更多
Left ventricular ejection fraction(LVEF)is an impor-tant predictor of cardiac outcome and helps in makingimportant diagnostic and therapeutic decisions suchas the treatment of different types of congestive heartfailur...Left ventricular ejection fraction(LVEF)is an impor-tant predictor of cardiac outcome and helps in makingimportant diagnostic and therapeutic decisions suchas the treatment of different types of congestive heartfailure or implantation of devices like cardiac resynchro-nization therapy-defibrillator.LVEF can be measuredby various techniques such as transthoracic echo-cardiography,contrast ventriculography,radionuclidetechniques,cardiac magnetic resonance imaging andcardiac computed tomographic angiography(CTA).Thedevelopment of cardiac CTA using multi-detector rowCT(MDCT)has seen a very rapid improvement in thetechnology for identifying coronary artery stenosis andcoronary artery disease in the last decade.During theacquisition,processing and analysis of data to studycoronary anatomy,MDCT provides a unique opportunityto measure left ventricular volumes and LVEF simulta-neously with the same data set without the need foradditional contrast or radiation exposure.The develop-ment of semi-automated and automated software to measure LVEF has now added uniformity,efficiency and reproducibility of practical value in clinical practice rather than just being a research tool.This article will address the feasibility,the accuracy and the limitations of MDCT in measuring LVEF.展开更多
A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility ...A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.展开更多
基金Supported by An unrestricted grant from the Keyser Family Fund(partly)
文摘AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric panniculitis from January 2005 to August 2010 were identified in the Radnet(Rad Net Corporation, Los Angeles, CA) database. Patients with a new or known diagnosis of a malignancy were included for this analysis. Longitudinal clinical histories were obtained from electronic medical records.RESULTS In total, 147794 abdominal CT scans were performed during the study period. Three hundred and fiftynine patients had mesenteric panniculitis(MP)-like abnormalities on their abdominal CT. Of these patients, 81 patients(22.6%) had a known history of cancer at the time of their CT scan. Nineteen(5.3%) had a new diagnosis of cancer in concurrence with their CT, but the majority of these(14/19, 74%) were undergoing CT as part of a malignancy evaluation. Lymphomas were the most common cancers associated with MPlike findings on CT(36 cases, 36%), with follicular lymphoma being the most frequent subtype(17/36). A variety of solid tumors, most commonly prostate(7) and renal cell cancers(6) also were seen. CT follow up was obtained in 56 patients. Findings in the mesentery were unchanged in 45(80%), worsened in 6(11%), and improved in 5 patients(9%). Positron emission tomography(PET) scans performed in 44 patients only showed a positive uptake in the mesenteric mass in 2 patients(5%). CONCLUSION A new diagnosis of cancer is uncommon in patients with CT findings suggestive of MP. MP-like mesenteric abnormalities on CT generally remain stable in patients with associated malignancies. PET scanning is not recommended in the evaluation of patients with mesenteric panniculitis-like findings on CT.
文摘Background: In 2010, the International Atomic Energy Agency launched the “3A’s campaign” as an effective tool for primary cancer prevention. In 2011, the American Association of Physicists in Medicine recommended the size specific dose estimate (SSDE). Objectives: To audit doses of Coronary CT Angiography (Coronary CTA) in tertiary care referral center. Methods: We reviewed 998 consecutive Coronary CTA (from 2007 to 2012). Doses (CTDIvol mGy), DLP (mGy*cm), effective dose (DLP*0.014, mSv) were on-line archived. SSDE was estimated retrospectively. Appropriateness score was evaluated for exams performed from the 2010. Results: Overall median dose per Coronary CTA was 49.7 mGy for CTDIvol, 55.5 mGy for SSDE, 994.96 mGy*cm for DLP, 13.9 mSv for effective dose. Median DLP decreased over time (1452.94 in 2007, 1605.56 in 2008, 1113.49 in 2009, 759.99 in 2010, 448.61 in 2011 and 497.88 mGy*cm in 2012, p < 0.0001). SSDE was proportional to the size dependent factor (SDF);in patients with SDF > 1 (88%) CTDIvol underestimated SSDE (48.49 vs 57.19 mGy), whilst in patients with SDF < 1 (12%) CTDIvol overestimated SSDE (56.46 vs 50.3 mGy). Scans were appropriate in 58%, uncertain in 24%, and inappropriate in 18% of cases. Doses were similar in appropriate, uncertain or inappropriate examinations and in excellent-to-good (81%) vs. sufficient-to-poor (19%) image quality exams. Conclusions: Coronary CTA reference doses can be very misleading. SSDE can allow individual technique optimization. The dose is similar in appropriate and inappropriate examinations, and unrelated to image quality. The rate of inappropriate examinations is still too high even after dissemination of guidelines.
文摘Objectives To compare the different patterns of coronary artery calcification (CAC) in acute and chronic coronary syndromes utilizing electron beam computed tomography. Background Pathologic, angiographic, and intracoronary ultrasound studies revealed sharp differences in the plaque morphology between patients with acute versus chronic coronary syndromes. Whether there are different patterns of coronary artery calcification in patients with stable angina pectoris (SAP) and in those with unstable angina pectoris (UAP) or acute myocardial infarction (AMI), however, remains unclear. Methods Two hundred and sixty - four patients, including 67 with SAP, 94 with UAP and 103 with AMI were studied with electron beam computed tomography for analysis of coronary artery calcification and with selective coronary angiography for determination of atherosclerotic lesions. CAC prevalence and calcium score were compared among three groups, and relation of CAC to the severity of atherosclerotic disease in the SAP and UAP patients was separately analyzed. Results Prevalence of CAC was 100 % in the SAP patients, significantly higher than the 87. 23 % in UAP patients and 86. 41 % among the patients with AMI ( P < 0. 05) . More patients and arteries in the SAP group had severe forms of calcium than those in the UAP and AMI group ( P < 0. 01), and the mean LN [CS + 1] (natural logarithm transformation of calcium score) of the SAP patients was much greater than that of the UAP and AMI patients (P < 0.001). The distribution of vessels with various CAC by luminal stenosis was different between SAP and UAP patients. The average CAC extent of the infarct - related arteries was less severe than that of the noninfarct - related arteries. Conclusions U-tilizing electron beam computed tomography, we demonstrated that there exist different patterns of coronary artery calcification in patients with acute versus chronic coronary syndromes, which may provide insight into the differences observed in the clinical and pathologic development between these two types of coronary artery disease.
基金supported by the National Natural Science Foundation of China(No.11375027)the Fundamental Research Funds for the Central Universities(No.2014k JJCA03)
文摘A tomography device based on a conventional laboratory x ray source, polycapillary parallel x ray lens (PPXRL), and polycapillary collimating x ray lens (PCXRL) is designed. The PPXRL can collect the divergent x ray beam from the source and focus it into a quasi-parallel x ray beam with a divergence of 4.7 rarad. In the center of quasi-parallel x ray beam, there is a plateau region with an average gain in power density of 13.8 and a diameter of 630μm. The contrast of the image can be improved from 28.9% to 56.0% after adding the PCXRL between the sample and the detector.
基金supported by the National Natural Science Foundation of China (No.60672098)the Tackling Key Problems of Science and Technology of ChongQing (No.CSTC2009AC3047)
文摘A new type of solid-conversion gas detector is investigated for high energy X-ray industrial computed tomography (HECT). The conversion efficiency is calculated by using the EGSnrc Monte Carlo code on the Linux platform to simulate the transport process of photons and electrons in the detector. The simulation results show that the conversion efficiency could be more than 65%, if the X-ray beam width is less than about 0.2 mm, and a tungsten slab with 0.2 mm thickness and 30 mm length is employed as a radiation conversion medium. Meanwhile the results indicate that this new detector has higher conversion efficiency as well as less volume. Theoretically this new kind of detector could take place of the traditional scintillation detector for HECT.
文摘The process of constructing a database of average cross-sections in Chinese proximal femurs is described. The main goal of creating the database is for designing hip stems for Chinese patients. Methods for constructing the database are introduced. According to some existing software and programs developed by the authors, a database of average cross-sections in Chinese proximal femurs was built based on CT images of eighty femur-specimens. 3-D shape of a patient's proximal femurs can be reconstructed according to the database and X-ray radiographs. Theoretical analyses and results of clinical application indicate that the database can be used to design hip stems for Chinese patients.
文摘Objectives To evaluate the ability of CT pleurography (CTP) in detecting minor pleural lesions in patients with pleural effusion and to assess its value in distinguishing malignant from benign pleural lesions. Methods A prospective study of 50 patients with pleural effusion was conducted using conventional CT and CTP. CT scan was run after injecting an appropriate amount of contrast medium into the pleural cavity. Results In 24 patients, all lesions detected by conventional CT were demonstrated by CTP. In 13 of 24 patients, CT pleurography detected additional lesions. In 20 of 26 patients with negative findings on conventional CT, CTP was capable of demonstrating the presence of pleural lesions. The sensitivity, specificity and accuracy of detecting pleural lesions were 25%, 100% and 30% for conventional CT, 86%, 100% and 87% for CTP, respectively. Conclusion CTP is superior to conventional CT in detecting and for the differential diagnosis benign and malignant pleural lesions.
文摘随着鼻窦CT诊断和鼻内镜诊疗技术的发展,大量鼻部疾病导致的头痛得以治愈。根据2004年国际头痛协会的分类,鼻源性头痛的第二种类型——黏膜接触点性头痛(mucosa contact point headache),因为缺少典型的鼻部症状,而分散就诊于其他学科,长期得不到合理诊疗。我们近期总结了多例临床上没有典型的鼻部症状,而是以各种类型的头痛为主诉就诊于神经内科等专科的患者,经过会诊筛查,确诊为鼻源性黏膜接触点性头痛,通过鼻内镜手术治愈。其中包括1组女性患者,长期被误认为是月经前期头痛,通过治疗证明是黏膜接触点性头痛的一种特殊存在形式,撰文总结如下。
基金supported by the National Key Research and Development Program of China (No. 2017YFC1309100)National Natural Scientific Foundation of China (No. 81771912, 81601469, and 81701782)+1 种基金the Science and Technology Planning Project of Guangdong Province (No. 2017B020227012)the Science and Technology Planning Project of Guangzhou (No. 20191A011002).
文摘Objective: To develop and validate a computed tomography(CT)-based radiomics nomogram for predicting human epidermal growth factor receptor 2(HER2) status in patients with gastric cancer.Methods: This retrospective study included 134 patients with gastric cancer(HER2-negative: n=87;HER2-positive: n=47) from April 2013 to March 2018, who were then randomly divided into training(n=94) and validation(n=40) cohorts. Radiomics features were obtained from the CT images showing gastric cancer. Least absolute shrinkage and selection operator(LASSO) regression analysis was utilized for building the radiomics signature. A multivariable logistic regression method was applied to develop a prediction model incorporating the radiomics signature and independent clinicopathologic risk predictors, which were then visualized as a radiomics nomogram. The predictive performance of the nomogram was assessed in the training and validation cohorts.Results: The radiomics signature was significantly associated with HER2 status in both training(P<0.001) and validation(P=0.023) cohorts. The prediction model that incorporated the radiomics signature and carcinoembryonic antigen(CEA) level demonstrated good discriminative performance for HER2 status prediction,with an area under the curve(AUC) of 0.799 [95% confidence interval(95% CI): 0.704-0.894] in the training cohort and 0.771(95% CI: 0.607-0.934) in the validation cohort. The calibration curve of the radiomics nomogram also showed good calibration. Decision curve analysis showed that the radiomics nomogram was useful.Conclusions: We built and validated a radiomics nomogram with good performance for HER2 status prediction in gastric cancer. This radiomics nomogram could serve as a non-invasive tool to predict HER2 status and guide clinical treatment.
文摘AIM To recognize the characteristic findings of non pathologic perfusion defects with CT arterial portography (CTAP) and nonpathologic enhancement found in CT hepatic arteriography (CTHA). METHODS The manifestations of nonpathologic perfusion defects with CTAP and non pathologic enhancement found in CTHA were analyzed in 50 patients with primary hepatocellular carcinoma. RESULTS The false positive rate of perfusion defects detected in CTAP was 15 1%. The shapes of perfusion defects were peripheral wedge, small, round, and patchy. The occurrence rate of non pathologic enhancement found in CTHA was 22 0%. The shapes of non pathologic enhancement were small, round, irregular, and wedge. CONCLUSION There was a high frequency of non pathologic perfusion defects detected with CTAP and non pathologic enhancement found in CTHA. The simultaneous use of both procedures may help decrease the false positive rate, and increase the veracity of diagnosis for hepatocellular carcinoma.
文摘Left ventricular ejection fraction(LVEF)is an impor-tant predictor of cardiac outcome and helps in makingimportant diagnostic and therapeutic decisions suchas the treatment of different types of congestive heartfailure or implantation of devices like cardiac resynchro-nization therapy-defibrillator.LVEF can be measuredby various techniques such as transthoracic echo-cardiography,contrast ventriculography,radionuclidetechniques,cardiac magnetic resonance imaging andcardiac computed tomographic angiography(CTA).Thedevelopment of cardiac CTA using multi-detector rowCT(MDCT)has seen a very rapid improvement in thetechnology for identifying coronary artery stenosis andcoronary artery disease in the last decade.During theacquisition,processing and analysis of data to studycoronary anatomy,MDCT provides a unique opportunityto measure left ventricular volumes and LVEF simulta-neously with the same data set without the need foradditional contrast or radiation exposure.The develop-ment of semi-automated and automated software to measure LVEF has now added uniformity,efficiency and reproducibility of practical value in clinical practice rather than just being a research tool.This article will address the feasibility,the accuracy and the limitations of MDCT in measuring LVEF.
基金the National Natural Science Foundation of China(Nos.11305116 and 11105098)the National Key Technology Support Program(No.2013BAK14B02)the National"973"Program ofChina(No.2011CB922203)
文摘A time-resolved multispectral X-ray imaging approach with new version of multi-channel Kirkpatrick- Baez (KB) microscope is developed for laser plasma diagnostics at the kilo joule-class Shenguang-II laser facility (SG-II). The microscope uses a total external reflection mirror in the sagittal direction and an array of multilayer mirrors in the tangential direction to obtain multiple individual high-resolution, high- throughput, and quasi-monochromatic X-ray images. The time evolution of the imploded target in multiple X-ray energy bands can be acquired when coupled with an X-ray streak camera. The experimental result of the time-resolved 2.5 and 3.0 keV dual-spectral self-emission imaging of the undoped CH shell target on SG-II is given.