期刊文献+
共找到200篇文章
< 1 2 10 >
每页显示 20 50 100
Clinical prediction of insufficient vaults after implantable collamer lens implantation
1
作者 Jun Zhu Dan Cheng +3 位作者 Xue-Ying Zhu Fen-Fen Li Ye Yang Yu-Feng Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1300-1306,共7页
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ... AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery. 展开更多
关键词 insufficient vault implantable collamer lens ciliary body posterior chamber
下载PDF
Early clinical outcome with lens position adjustment following implantable collamer lens surgery
2
作者 Qian Zhang Bo Zhao +2 位作者 Xue-Fei Yang Zhang-Lin Liu Yue Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1654-1658,共5页
AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient recei... AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient received Toric ICL for astigmatism correction,and the other received non-astigmatic ICL surgery using horizontal position.Patients with higher postoperative arch height were selected,and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk,1,and 3mo.The clinical measurements included uncorrected visual acuity(UCVA),intraocular pressure(IOP),refractive state,corneal endothelium cell count,and arch height.Three months later,the ICL in each patient’s non-astigmatic eye was adjusted to the vertical from the horizontal position.The results were compared before and 1wk,1,and 3mo after adjustment.RESULTS:UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation(P<0.05).The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk,1,and 3mo after adjusting position compared to 1wk,1,and 3mo after ICL implantation(P<0.05).However,there was no significant difference in refraction between 1wk,1,and 3mo after ICL implantation and position adjustment(P>0.05).CONCLUSION:Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP.Despite the good clinical effects,the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation. 展开更多
关键词 implantable collamer lens MYOPIA lens positional adjustment arch height intraocular pressure
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
3
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:4
4
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction:a 5-year follow-up 被引量:4
5
作者 Xiao Chen Li Li +4 位作者 Jing Rao Yue-Xi Chen Yang Gao Rui-Xue Huang Qi-Zhi Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1123-1129,共7页
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted... AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery. 展开更多
关键词 implantable collamer lens with central hole myopia correction refractive surgery visual quality
下载PDF
Vault predicting after implantable collamer lens implantation using random forest network based on different features in ultrasound biomicroscopy images 被引量:2
6
作者 Bin Fang Qiu-Jian Zhu +1 位作者 Hui Yang Li-Cheng Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1561-1567,共7页
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we... AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection. 展开更多
关键词 random forest network ultrasound biomicroscopy images vault prediction implantable collamer lens
下载PDF
A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport 被引量:5
7
作者 Kyu-Yeon Hwang Sung A.Lim So-Hyang Chung 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期1014-1015,共2页
To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. ... To improve humor circulation the latest V4c Visian implantable collamer lens (ICL) was designed with a0.36-ram Aquapon. This design also eliminates the need to perform peripheral iridectomy before ICL implantation. Several authors reported rates of secondary surgical intervention related to insufficient vault in the presence or absence of cataract formation and excessive vault in the presence or absence of elevated intraocular pressure (IOP) after ICL insertion. Here, we report a case of rapid progression of a cataract to a hypermature state after implantation of an ICL with an Aquaport. 展开更多
关键词 ICL A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport CASE
下载PDF
Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography 被引量:3
8
作者 Jing Zhang Fang-Lin He +1 位作者 Yan Liu Xian-Qun Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期773-781,共9页
AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation usin... AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation using swept-source optical coherence tomography(SS-OCT).METHODS:We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation.Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery.The CT was measured with SS-OCT.All data were recorded preoperatively and 2 h,1 wk,1 and 3 mo postoperatively.Other demographic information was collected,including age,sex,uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),spherical equivalent(SE),intraocular pressure(IOP)and axial length(AL).RESULTS:The UCVA improved in both groups and showed no significant differences between groups.There also were no significant differences between the two groups in postoperative BCVA and SE(P=0.581 and 0.203,respectively).The foveal CTs,inner nasal and outer nasal CTs were significantly thicker at 2 h postoperatively in both groups(P<0.05)but returned to baseline levels in 1 wk;after 1 mo,no significant differences were found relative to the preoperative values.At 3 mo in each group,nine regions showed variations in the CT as compared with preoperative thickening,but only the foveal and nasal area CTs preoperative differences were statistically significant(P<0.05).In addition,there was no significant difference in 9 regions of CT between the two groups at all follow-up times(P>0.05).CONCLUSION:The CTs after ICL implantation and FSLASIK surgery are significantly thicker than those before operation,especially in the foveal and nasal areas,but there is no significant difference between the two methods. 展开更多
关键词 choroidal thickness high myopia laser in situ keratomileusis implantable collamer lens implantation swept-source optical coherence tomography
下载PDF
Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis 被引量:13
9
作者 Hong-Ting Liu Zhou Zhou +8 位作者 Wu-Qiang Luo Wen-Jing He Owhofasa Agbedia Jiang-Xia Wang Jian-Zhong Huang Xin Gao Min Kong Min Li Li Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第4期656-661,共6页
AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia... AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality. 展开更多
关键词 optical quality implantable collamer lens wavefront-guided laser in situ keratomileusis
下载PDF
Clinical observations of iridociliary cysts and their changes after implantable collamer lens implantation in myopic patients 被引量:3
10
作者 Qian Chen Meng-Ying Qi +1 位作者 Xiao-Hua Lei Qing-Yan Zeng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第6期965-969,共5页
AIM:To observe the characteristics of iridociliary cysts in myopic patients and evaluate the influences on the position and safety of implantable collamer lens(ICL)after surgery.METHODS:Totally 270 eyes of 135 patient... AIM:To observe the characteristics of iridociliary cysts in myopic patients and evaluate the influences on the position and safety of implantable collamer lens(ICL)after surgery.METHODS:Totally 270 eyes of 135 patients who underwent ICL surgery for the corrections of myopia were included in this study.Preoperative and postoperative morphology of iridociliary cysts were observed in ultrasonic biomicroscopy(UBM)image.RESULTS:A total of 138 iridociliary cysts were found in 88 eyes of 50 patients among 270 eyes of 135 patients before surgery(37%).Twenty-five patients had cysts in one eye(50%)and 25 had cysts in both eyes(50%).The prevalence of iridociliary cysts was negatively correlated with age,but no gender difference(P>0.05).The incidence of iridociliary cysts was much less in eyes with myopia greater than-9.00 D(P<0.05).The diameter of the largest cyst was 1.96 mm and the smallest cyst was 0.24 mm,with a majority within the range of 0.5 to 1.0 mm.Most of the cysts were located in the inferior temporal quadrant.One year after ICL implantation,51 iridociliary cysts(37%)remained unchanged,47 cysts(34%)decreased in size,and 40 cysts(29%)disappeared.Most of cysts that changed after surgery were smaller than 1.0 mm(P<0.05)and located in the nasal and temporal sides around the haptics of implantable lens.All the ICL were in their original position.CONCLUSION:Iridociliary cysts are commonly seen in myopic eyes.The cysts have no impact on the safety of ICL surgery.Some cysts may decrease in size or disappear after ICL implantation. 展开更多
关键词 iridociliary cysts implantable collamer lens myopic
下载PDF
Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation 被引量:2
11
作者 Shu-Yang Chen Chen Xie +1 位作者 Yang Wang Ye Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1239-1242,共4页
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien... Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation. 展开更多
关键词 ICL IOL Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
下载PDF
The effects of implantable collamer lens implantation on higher order aberrations 被引量:1
12
作者 Belma Kayhan Efekan Coskunseven +1 位作者 Onurcan Sahin Ioannis Pallikaris 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1848-1852,共5页
AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in... AIM: To evaluate the changes in higher order aberrations(HOAs) after implantable collamer lens(ICL;Staar Surgical, Nidau, Switzerland) implantation. METHODS: Totally 30 eyes of 18 patients with myopia were included in this study with an average age of 25.77y(min: 21, max: 40). Refraction, uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), HOAs(entire, corneal and internal) were evaluated preoperatively and three months postoperatively. Ocular aberrations were measured by using iT race(Tracey Technology, Houston, Texas, USA). SPSS(IBM Corp. Released 2013. IBM SPSS Statistics for Windows, Version 22.0. Armonk, NY: IBM Corp) was used for the statistical analysis and the interpretation of the data. P values of less than 0.05 were considered statistically significant. RESULTS: The preoperative mean spherical power was -9.01 D(min:-5.00, max:-13.00) and the mean cylindrical error was -2.40 D(min:-0.50, max:-4.75). The postoperative mean residual spherical power was -0.73 D(min:-0.20, max:-1.75) and the mean cylindrical error was -0.89 D(min:-0.18, max:-2.09). Analyses were made on root mean square(RMS) values of total HOAs(tH OAs), spherical aberration, coma and trefoil as entire, corneal and internal components. The differences in entire t HOAs and in internal t HOAs were significant. There was no significant change found in spherical aberrations. The differences in entire coma and in internal coma were significant. There was no significant change found in corneal coma. With respect to trefoil, the only significant difference was in internal trefoil. CONCLUSION: The ICL implantation corrects the refractive error successfully and changes entire and internal HOAs of the eye. 展开更多
关键词 implantable collamer lens MYOPIA ABERRATIONS
下载PDF
Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens 被引量:7
13
作者 Min Ji Park Hye Min Jeon Kyoung Heon Lee Sang Youp Han 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期619-623,共5页
AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eye... AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering. 展开更多
关键词 implantable collamer lens optical quality phakic IOL refractive surgery
下载PDF
Implantable collamer lens for residual refractive error after corneal refractive surgery 被引量:6
14
作者 Xun Chen Xiao-Ying Wang +2 位作者 Xi Zhang Zhi Chen Xing-Tao Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第10期1421-1426,共6页
AIM:To assess the safety,efficacy,predictability and stability of implantable collamer lens(ICL) for residual refractive error after corneal refractive surgery.METHODS: This study evaluated 19 eyes of 12 patients ... AIM:To assess the safety,efficacy,predictability and stability of implantable collamer lens(ICL) for residual refractive error after corneal refractive surgery.METHODS: This study evaluated 19 eyes of 12 patients who underwent ICL implantation after corneal refractive surgeries.They were followed up for 1y to 5y of uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),manifest refractive error,flat and steep K value,axial length,intraocular pressure,corneal endothelial cell density,adverse events after ICL surgery.RESULTS: The mean follow-up period was 39.05 ±19.22 mo(range,1-5y).Spherical equivalent refractive error changed from-7.45±3.02 D preoperatively to-0.85±1.10 D 1wk to 1mo after ICL implantation,with the safety and efficacy indices being 1.12 and 1.15,respectively.A total of 52.63% of eyes were within ±0.5 D of the predicted spherical equivalents,73.68% were within ±1.0 D.A trend of mild regression towards myopia with axial elongation after 5y was observed.One eye with mild anterior capsule opacity and retinal detachment 1y after surgery were observed.CONCLUSION: ICL implantation is safe and effective for the correction of residual refractive error after corneal refractive surgeries,especially in moderate to high residual myopia. 展开更多
关键词 implantable collamer lens radial keratotomy photorefractive keratectomy laser-assisted in situ keratomileusis laser-assisted subepithelial keratomileusis
下载PDF
Optical and visual quality comparison of implantable collamer lens and femtosecond laser assisted laser in situ keratomileusis for high myopia correction 被引量:2
15
作者 Zheng Jiang Hua Wang +1 位作者 Dong-Qiang Luo Jiao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第5期737-743,共7页
AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optica... AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK. 展开更多
关键词 implantable collamer lens implantation femtosecond laser assisted laser in situ keratomileusis refractive stability high myopia
下载PDF
Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus 被引量:1
16
作者 Albanderi Alhamzah Saad S.Alharbi +2 位作者 Fahad Alfardan Tariq Aldebasi Tariq Almudhaiyan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第11期1714-1720,共7页
AIM:To evaluate the causes of phakic implantable collamer lens(ICL)exchange/explantation in patients with and without keratoconus(KC)at two tertiary hospitals in Riyadh,Saudi Arabia.METHODS:A retrospective chart revie... AIM:To evaluate the causes of phakic implantable collamer lens(ICL)exchange/explantation in patients with and without keratoconus(KC)at two tertiary hospitals in Riyadh,Saudi Arabia.METHODS:A retrospective chart review of all patients who underwent ICL(model V4 c with central port)exchange/explantation was performed using the electronic medical record systems.All available preoperative and postoperative data were documented for each patient.RESULTS:Over 7 y,2283 ICL implantation procedures were performed;46 implants(2%)required exchange(21 implants)/explantation(25 implants),of which 14 cases(30.4%)were patients with KC.Indications for ICL exchange/explantation in non-KC group were vault measurement,cataract formation,increased intraocular pressure,inaccurate refraction,and patient dissatisfaction in 22(68.75%),4(12.5%),3(9.37%),2(6.25%),and 1(3.12%)case,respectively.The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients(78.57%),inaccurate refraction in 2 patients(14.28%),and patient dissatisfaction postoperatively in 1(7.14%)case.CONCLUSION:ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature.Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC. 展开更多
关键词 EXPLANTATION EXCHANGE implantable collamer lens vault
下载PDF
不同方位植入TICL的临床疗效及稳定性比较
17
作者 廖艳芬 关念 +2 位作者 沈政伟 何星 刘颖 《国际眼科杂志》 2024年第2期210-215,共6页
目的:比较水平、斜轴、垂直植入散光型有晶状体眼后房型人工晶状体(TICL)后临床疗效、拱高及旋转稳定性。方法:回顾性队列研究。收集2018-07/2022-03在武汉普瑞眼科医院植入TICL后至少规律随访1 a(术后1 d,1 wk,1、3、6 mo,1 a)的患者... 目的:比较水平、斜轴、垂直植入散光型有晶状体眼后房型人工晶状体(TICL)后临床疗效、拱高及旋转稳定性。方法:回顾性队列研究。收集2018-07/2022-03在武汉普瑞眼科医院植入TICL后至少规律随访1 a(术后1 d,1 wk,1、3、6 mo,1 a)的患者资料共92例120眼,根据TICL轴位在眼内的方位分三组:水平放置组(34例45眼)、斜轴放置组(25例29眼)、垂直放置组(33例46眼)。对比患者术后的裸眼视力(UDVA)及最佳矫正视力(CDVA)、屈光度、拱高及旋转角度(TICL实际轴位与预期轴位的偏差)。结果:所有患者手术均顺利完成,术后均未出现感染、继发性青光眼、晶状体混浊等并发症。手术安全性及有效性:三组患者术后1 a的CDVA均优于或等于术前CDVA,三组患者的术后UDCA及CDVA均无差异(P>0.05)。术后1 a,三组患者安全性指数分别为1.34±0.21、1.34±0.17和1.31±0.18,有效性指数分别为1.26±0.21、1.33±0.18、1.27±0.16,均无差异(P>0.05)。拱高:三组患者术后不同时间的拱高有显著差异(P=0.003),垂直组<水平组<斜轴组。三组组内不同随访时间点的拱高有差异(P<0.001),均随时间推移呈下降趋势。残留散光:三组患者的残留散光无显著差异(P=0.130),组内不同随访时间点的残留散光有差异(P<0.001)。旋转角度:三组患者的旋转角度无显著差异(P=0.135),组内不同随访时间点的旋转角度有差异(P<0.001)。结论:不同方位植入TICL均具有良好的安全性、有效性,术后旋转稳定性均良好,临床上可根据情况选用合适的角度植入TICL。 展开更多
关键词 散光型有晶状体眼后房型人工晶状体(ticl) 拱高 放置方向 旋转稳定性
下载PDF
矢量分析法评价TICL V4c植入术矫正中高度近视合并高度散光的临床疗效
18
作者 刘银 江文珊 陈晓 《国际眼科杂志》 CAS 2024年第3期484-490,共7页
目的:采用矢量分析法和屈光矫正者生活质量(QIRC)量表评估散光型中央孔型有晶状体眼后房型人工晶状体(TICL V4c)矫正中高度近视合并高度散光的临床疗效。方法:回顾性病例系列研究。选取2019-01/2022-12在我院眼科近视手术中心行TICL V4... 目的:采用矢量分析法和屈光矫正者生活质量(QIRC)量表评估散光型中央孔型有晶状体眼后房型人工晶状体(TICL V4c)矫正中高度近视合并高度散光的临床疗效。方法:回顾性病例系列研究。选取2019-01/2022-12在我院眼科近视手术中心行TICL V4c植入术的中高度近视合并高度散光患者55例90眼。术后随访1 a,观察裸眼视力(UDVA)、最佳矫正视力(BCVA)、屈光度等情况,采用Alpins矢量分析法评估散光矫正效果,并采用QIRC量表评估患者的生活质量。结果:术后1 a,98%术眼UDVA达到甚至优于术前BCVA,手术安全性指数为1.11±0.14,有效性指数为1.11±0.15;97%术眼散光的误差角度在±15°以内,散光的矢量分析结果显示散光矫正指数为0.83±0.13,误差角度为1.00°±4.49°,成功指数为0.21±0.15。术后1 a,纳入患者6 mm瞳孔直径下角膜总高阶像差较术前明显增加(P<0.05),QIRC量表总分明显高于术前(P<0.001),且QIRC量表总分的增加量与术前球镜度数呈正相关(r s=0.215,P<0.05),提示术前近视程度越高,TICL植入术后生活质量提高越显著。结论:TICL V4c植入术矫正中高度近视合并高度散光安全有效,且术后生活质量显著提高。 展开更多
关键词 有晶状体眼散光型人工晶状体(ticl)植入术 高度散光 矢量分析法 生活质量
下载PDF
TICL V4c植入术后拱高对散光轴旋转角度的影响
19
作者 杨钰涵 蒋浩 +2 位作者 龙秋蓉 张丽颖 谷浩 《贵州医科大学学报》 CAS 2024年第1期145-150,共6页
目的 分析有晶体眼散光型人工晶体(TICl V4c)植入术后拱高对人工晶体散光轴旋转角度的影响。方法 选取眼科接受TCIL V4c植入术的近视患者89例(174眼),按照术后1周拱高的大小分为低拱高组、中拱高组以及高拱高组,术前检测患者裸眼视力(UC... 目的 分析有晶体眼散光型人工晶体(TICl V4c)植入术后拱高对人工晶体散光轴旋转角度的影响。方法 选取眼科接受TCIL V4c植入术的近视患者89例(174眼),按照术后1周拱高的大小分为低拱高组、中拱高组以及高拱高组,术前检测患者裸眼视力(UCVA)、最佳矫正视力(BCVA)、屈光情况(球镜度数及柱镜度数)、非接触式眼压(IOP)、前房深度(ACD)以及内皮细胞计数(ECD);术后随访2年,记录患者的拱高变化情况及散光轴旋转角度情况,分析拱高与散光轴旋转角度的关系。结果 TICl V4c植入术后2年,低、中、高拱高组3组患者术后平均UCVA均高于术前(P<0.01);术后2年,3组患者的UCVA(0.97±0.24)好于术前BCVA(t=-8.78,P<0.01);3组近视患者术前的平均球镜度(-10.10±3.76)D提升至术后的(-0.39±0.81)D,术前的平均柱镜度(-2.36±1.03)D提升至术后的(-0.44±1.53)D(P<0.01);术后随访3组患者IOP、ECD均保持在正常范围内,且与术前比较,差异无统计学意义(P>0.05);所有患者术后均未发生青光眼、视网膜脱离以及葡萄膜炎等严重并发症;随访2年中3组患者的拱高变化不明显(P>0.05);患者晶体散光轴均发生不同程度的旋转,相关性分析表明,拱高与散光轴旋转角度不存在相关性(r=-0.117,P>0.05)。结论 TICL V4c植入术具有良好的有效性和安全性,术后产生的拱高对散光轴旋转角度并无明显影响。 展开更多
关键词 拱高 人工晶体散光轴 有晶体眼散光型人工晶体植入术 近视 散光 屈光不正
下载PDF
Case report:simultaneous femtosecond laser astigmatic keratotomy and toric intraocular lens implantation in femtosecond laser-assisted cataract surgery in a patient with surgically induced high corneal astigmatism
20
作者 Yan Guo Heather Edwards +2 位作者 Mark Woodward Tyrone Curtis Gresham Kayla Morgan 《Annals of Eye Science》 2022年第4期69-76,共8页
Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically... Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty(LTK)in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery(FLACS).This is the first report of both procedures combined simultaneously,with or without history of LTK.Case Description:A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004,with subsequent surgically induced high corneal astigmatism,and with age-related nuclear cataract of both eyes.IOL master demonstrated+7.71 diopters of astigmatism at 163 degree right eye and+3.29 diopters of astigmatism at 4 degree left eye.After extensive discussion of the risks and benefits,the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions(RIs)and toric IOL(Alcon SN6AT9)right eye;FLACS with toric IOL(Alcon SN6AT7)alone left eye.At 2-year follow-up,uncorrected visual acuity was 20/30 right eye,20/25 left eye.His best corrected visual acuity was 20/25(+0.25+1.00 axis 21)right eye and 20/20(plano+0.25 axis 90)left eye;his best corrected near visual acuity was J1+with add+2.50 diopters right eye and left eye.Conclusions:Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery.An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9,in our case,simultaneously,which can achieve an excellent long term visual outcome. 展开更多
关键词 High corneal astigmatism[induced by laser thermal keratoplasty(LTK)] femtosecond laser astigmatic keratotomy(FSAK) toric intraocular lens implantation(IOL implantation) femtosecond laser-assisted cataract surgery(FLACS) case report
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部