This paper examined the impacts of the total energy consumption control policy and energy quota allocation plans on China′s regional economy. This research analyzed the influences of different energy quota allocation...This paper examined the impacts of the total energy consumption control policy and energy quota allocation plans on China′s regional economy. This research analyzed the influences of different energy quota allocation plans with various weights of equity and efficiency, using a dynamic computable general equilibrium(CGE) model for 30 province-level administrative regions. The results show that the efficiency-first allocation plan costs the least but widens regional income gap, whereas the outcomes of equity-first allocation plan and intensity target-based allocation plan are similar and are both opposite to the efficiency-first allocation plan′ outcome. The plan featuring a balance between efficiency and equity is more feasible, which can bring regional economic losses evenly and prevent massive interregional migration of energy-related industries. Furthermore, the effects of possible induced energy technology improvements in different energy quota allocation plans were studied. Induced energy technology improvements can add more feasibility to all allocation plans under the total energy consumption control policy. In the long term, if the policy of the total energy consumption control continues and more market-based tools are implemented to allocate energy quotas, the positive consequences of induced energy technology improvements will become much more obvious.展开更多
This paper presents the evaluation of the “capacity to the total energy consumption per bit ratio” of multiple antennas systems with distributed fashion. We propose an adequate geometric channel modeling for the wir...This paper presents the evaluation of the “capacity to the total energy consumption per bit ratio” of multiple antennas systems with distributed fashion. We propose an adequate geometric channel modeling for the wireless communication system which operates in indoor propagation environment with scatterers. The channel model is derived in function of both the line of sight (LOS) and the non line of sight (NLOS) components. The aim of this paper is to study the limits in the gain concerning the capacity to the total energy consumption ratio when additional antennas are implemented in the communication system. To do so, we have evaluated by simulations both the capacity and the total energy consumption per bit. Then, we have determined the capacity to the total energy consumption ratio. Finally, the computational capacity to the total energy ratio is obtained for different system configurations. We have shown that the gain in capacity increases with the number of antennas but it stills be limited by the total energy consumption. The limits for increasing the number of transmit antennas are determined in function of the separation distances between the transmitter and the receiver sides of the communication system. Optimal power allocation strategy via water-filling algorithm has been carried out for evaluating the capacity to energy ratio. We find by simulation that optimal power allocation brings a gain in the addressed metric reaching a level of about 1.7 at transmit signal to noise ratio of 8 dB if comparing to the case when transmit energy is equally split among transmit antennas.展开更多
项目供热面积约1.14×10^(5)m^(2),总热负荷7000 k W,采用中深层地热供热,平均热负荷为4859.09 kW,项目年耗热量为62959.68 GJ。热源为1口水热型地热井,按照“一采一灌、同层回灌、取热不耗水”的模式进行建设,配套回灌井1口。利用...项目供热面积约1.14×10^(5)m^(2),总热负荷7000 k W,采用中深层地热供热,平均热负荷为4859.09 kW,项目年耗热量为62959.68 GJ。热源为1口水热型地热井,按照“一采一灌、同层回灌、取热不耗水”的模式进行建设,配套回灌井1口。利用中深层地热水作为供热热源,冬季提供45℃/40℃采暖循环水,采用“板换直供+热泵机组调峰”的方式为项目供热。按照30年运行期测算,中深层地热方案相比于天然气锅炉方案可节省费用1.127738×10^(8)元。展开更多
基金National Natural Science Foundation of China(No.41101556,71173212,71203215)
文摘This paper examined the impacts of the total energy consumption control policy and energy quota allocation plans on China′s regional economy. This research analyzed the influences of different energy quota allocation plans with various weights of equity and efficiency, using a dynamic computable general equilibrium(CGE) model for 30 province-level administrative regions. The results show that the efficiency-first allocation plan costs the least but widens regional income gap, whereas the outcomes of equity-first allocation plan and intensity target-based allocation plan are similar and are both opposite to the efficiency-first allocation plan′ outcome. The plan featuring a balance between efficiency and equity is more feasible, which can bring regional economic losses evenly and prevent massive interregional migration of energy-related industries. Furthermore, the effects of possible induced energy technology improvements in different energy quota allocation plans were studied. Induced energy technology improvements can add more feasibility to all allocation plans under the total energy consumption control policy. In the long term, if the policy of the total energy consumption control continues and more market-based tools are implemented to allocate energy quotas, the positive consequences of induced energy technology improvements will become much more obvious.
文摘This paper presents the evaluation of the “capacity to the total energy consumption per bit ratio” of multiple antennas systems with distributed fashion. We propose an adequate geometric channel modeling for the wireless communication system which operates in indoor propagation environment with scatterers. The channel model is derived in function of both the line of sight (LOS) and the non line of sight (NLOS) components. The aim of this paper is to study the limits in the gain concerning the capacity to the total energy consumption ratio when additional antennas are implemented in the communication system. To do so, we have evaluated by simulations both the capacity and the total energy consumption per bit. Then, we have determined the capacity to the total energy consumption ratio. Finally, the computational capacity to the total energy ratio is obtained for different system configurations. We have shown that the gain in capacity increases with the number of antennas but it stills be limited by the total energy consumption. The limits for increasing the number of transmit antennas are determined in function of the separation distances between the transmitter and the receiver sides of the communication system. Optimal power allocation strategy via water-filling algorithm has been carried out for evaluating the capacity to energy ratio. We find by simulation that optimal power allocation brings a gain in the addressed metric reaching a level of about 1.7 at transmit signal to noise ratio of 8 dB if comparing to the case when transmit energy is equally split among transmit antennas.
文摘项目供热面积约1.14×10^(5)m^(2),总热负荷7000 k W,采用中深层地热供热,平均热负荷为4859.09 kW,项目年耗热量为62959.68 GJ。热源为1口水热型地热井,按照“一采一灌、同层回灌、取热不耗水”的模式进行建设,配套回灌井1口。利用中深层地热水作为供热热源,冬季提供45℃/40℃采暖循环水,采用“板换直供+热泵机组调峰”的方式为项目供热。按照30年运行期测算,中深层地热方案相比于天然气锅炉方案可节省费用1.127738×10^(8)元。