To overcome the inherent limits of traditional single wave imaging for nondestructive testing,the multi-wave focusing and imaging method is thoroughly studied.This method makes the compressional waves and shear waves ...To overcome the inherent limits of traditional single wave imaging for nondestructive testing,the multi-wave focusing and imaging method is thoroughly studied.This method makes the compressional waves and shear waves focused in both emission and reception processes,which strengthens the focusing energy and improves the signal-to-noise ratio of received signals.A numerical model is developed to study the characteristics of a multi-wave focusing field.It is shown that the element width approaching 0.8 wavelengths of shear waves can keep a balance between the radiation energy of two waves,which can achieve a desirable multi-wave focusing performance.And an experiment using different imaging methods for a linear phased array is performed.It can be concluded that due to the combination of the propagation and reflection characteristics of two waves,the multi-wave focusing and imaging method can significantly improve the imaging distinguishability of defects and expand the available sweeping range to a sector of-650 to 65°.展开更多
Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT.However,it is still suffering from the time-co...Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT.However,it is still suffering from the time-consuming data acquisition and processing.In order to solve the problem,two simplified matrix focusing methods are provided in the paper.One provided method is a triangular matrix focusing algorithm based on the principle of reciprocity for the multi-channel ultrasonic system.The other provided method is a trapezoidal matrix focusing algorithm based on the energy weight of the different channel to the focusing area.Time of data acquisition and computational is decreased with the provided simplified matrix focusing methods.In order to prove the validity of two provided algorithms,both side-drilled holes and oblique cracks are used for imaging experiments.The experimental results show that the imaging quality of the triangular matrix focusing algorithm is basically consistent to that of the full matrix focusing method.And imaging quality of the trapezoidal matrix focusing algorithm is slightly reduced with the amount of multi-channel data decreasing.Both data acquisition and computational efficiency using the triangular matrix focusing algorithm and the trapezoidal matrix focusing algorithm have been improved significantly compared with original full matrix focusing method.展开更多
基金the National Natural Science Foundation of China(Grant No.11774377)。
文摘To overcome the inherent limits of traditional single wave imaging for nondestructive testing,the multi-wave focusing and imaging method is thoroughly studied.This method makes the compressional waves and shear waves focused in both emission and reception processes,which strengthens the focusing energy and improves the signal-to-noise ratio of received signals.A numerical model is developed to study the characteristics of a multi-wave focusing field.It is shown that the element width approaching 0.8 wavelengths of shear waves can keep a balance between the radiation energy of two waves,which can achieve a desirable multi-wave focusing performance.And an experiment using different imaging methods for a linear phased array is performed.It can be concluded that due to the combination of the propagation and reflection characteristics of two waves,the multi-wave focusing and imaging method can significantly improve the imaging distinguishability of defects and expand the available sweeping range to a sector of-650 to 65°.
基金Supported by the National Natural Science Foundation of China(Grant No.51905070).
文摘Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT.However,it is still suffering from the time-consuming data acquisition and processing.In order to solve the problem,two simplified matrix focusing methods are provided in the paper.One provided method is a triangular matrix focusing algorithm based on the principle of reciprocity for the multi-channel ultrasonic system.The other provided method is a trapezoidal matrix focusing algorithm based on the energy weight of the different channel to the focusing area.Time of data acquisition and computational is decreased with the provided simplified matrix focusing methods.In order to prove the validity of two provided algorithms,both side-drilled holes and oblique cracks are used for imaging experiments.The experimental results show that the imaging quality of the triangular matrix focusing algorithm is basically consistent to that of the full matrix focusing method.And imaging quality of the trapezoidal matrix focusing algorithm is slightly reduced with the amount of multi-channel data decreasing.Both data acquisition and computational efficiency using the triangular matrix focusing algorithm and the trapezoidal matrix focusing algorithm have been improved significantly compared with original full matrix focusing method.