BACKGROUND Hemophilia A is a rare inherited bleeding disorder caused by mutations in the factor Ⅷ gene. This clotting factor plays an intrinsic role in the blood coagulation pathway. Patients with hemophilia may deve...BACKGROUND Hemophilia A is a rare inherited bleeding disorder caused by mutations in the factor Ⅷ gene. This clotting factor plays an intrinsic role in the blood coagulation pathway. Patients with hemophilia may develop orthopedic manifestations such as hemarthrosis, but multiple malunion of fractures over the knee is rare and difficult to treat.CASE SUMMARY We report a patient with hemophilia A who developed severe knee osteoarthritis along with fracture malunion and nonunion. Total knee replacement was performed using a custom-made modular hinged knee prosthesis(cemented) equipped with extended distal and proximal stems. At 3 years’ follow-up, the patient exhibited excellent clinical function and remained satisfied with the surgical outcome. Surgical intervention was accompanied by rigorous coagulation factor replacement.CONCLUSION This case highlights various unique scenarios specific to individuals with hemophilia and fracture deformity.展开更多
At present,most total knee replacement(TKR)prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A ...At present,most total knee replacement(TKR)prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A number of reports have indicated that Chinese TKR patients do not match with available prostheses.In this study,computed tomography(CT)images of 52 knees of Chinese men and women were used for anthropometric measurements.Index and geometric measurements were definedand used for correlation analysis.Key parameters from the measurement results were identified.Detailed geometries of knees were measured as coordinates.A deformable three-dimensional(3D)knee modelbased on anatomical coordinates correlating with the identified key parameters was generated.A pros-thesis was then designed according to the analyzed results.Surface matching analysis,bone resectionanalysis,and cadaveric trials were conducted and compared with commercial products to validate theproposed design.The femoral component designed by this study resulted in the highest accuracy(rootmean square point-to-surface(RMS PS),(1.08±0.20)mm)and lowest amount of resected bone volume(27412mm^(3))in comparison with two commercial knee prostheses.This study suggests a new approachfor population-based patient-specific femoral prosthesis design With a single,easilty acquired dimen-sion-namely,epicondyle width(ECW)-as input,a patient-specific femoral prosthesis can be designed according to the analyzed measured data and manufactured by additive manufacturing(AM)methods.Meanwhile,the reconstructed femoral condylar surface was compared with the femoral condylar surfacein the original CT scanning data The average RMS PS distance of the reconstructed femoral condylar surface among all data was(1.10±0.18)mm,which is comparable to other statistical shape modeling methods using multiple radiographs as input data.There is a need to develop an anthropometric-based knee prosthesis for the Chinese population.Based on the anthropometry of the Chinese population,our new design fits Chinese patients better and reserves more bone volume compared with current commercial prostheses,which is an essential step toward AM for personalized knee prostheses.展开更多
There are several prosthetic knee designs currently in use. There are however very few studies comparing long-term functional outcomes between patients using different models of knee pros-thesis in elective knee repla...There are several prosthetic knee designs currently in use. There are however very few studies comparing long-term functional outcomes between patients using different models of knee pros-thesis in elective knee replacement. In this study, we used the validated Oxford Knee Score (OKS) to retrospectively compare the outcomes of a total of 1635 patients who had an elective total knee replacement in a large District General Hospital, using fifteen different models of knee prosthesis, over a ten-year period. The average scores reported by all patient groups showed significant improvement by three months post-operatively (pre-operative mean score 15.8, post-operative mean score 39.4, p < 0.05), and remained similar for all models of prosthesis used over the total ten-year period. Based on the OKS as an assessment tool, we report no significant difference in long-term functional outcomes for this group of patients following an elective knee replacement, regardless of the type of prosthesis used.展开更多
Negative-pressure wound therapy(NPWT) has been a successful modality of wound management which is in widespread use in several surgical fields. The main mechanisms of action thought to play a role in enhancing wound h...Negative-pressure wound therapy(NPWT) has been a successful modality of wound management which is in widespread use in several surgical fields. The main mechanisms of action thought to play a role in enhancing wound healing and preventing surgical site infection are macrodeformation and microdeformation of the wound bed, fluid removal, and stabilization of the wound environment. Due to the devastating consequences of infection in the setting of joint arthroplasty, there has been some interest in the use of NPWT following total hip arthroplasty and total knee arthroplasty. However, there is still a scarcity of data reporting on the use of NPWT within this field and most studies are limited by small sample sizes, high variability of clinical settings and end-points. There is little evidence to support the use of NPWT as an adjunctive treatment for surgical wound drainage, and for this reason surgical intervention should not be delayed when indicated. The prophylactic use of NPWT after arthroplasty in patients that are at high risk for postoperative wound drainage appears to have the strongest clinical evidence. Several clinical trialsincluding single-use NPWT devices for this purpose are currently in progress and this may soon be incorporated in clinical guidelines as a mean to prevent periprosthetic joint infections.展开更多
目的设计制造一种考虑假体尺寸的全膝关节置换术截骨导板(简称截骨导板),实现术中快速、精准定位、辅助截骨的目的。方法截骨导板采用德国EOS公司的FORMIGA P 110三维(3D)打印设备制造,打印材料为聚十二内酰胺(PA12)。通过CT、股骨3D重...目的设计制造一种考虑假体尺寸的全膝关节置换术截骨导板(简称截骨导板),实现术中快速、精准定位、辅助截骨的目的。方法截骨导板采用德国EOS公司的FORMIGA P 110三维(3D)打印设备制造,打印材料为聚十二内酰胺(PA12)。通过CT、股骨3D重建、假体逆向重建获得股骨远端与假体的数字模型,用计算机手术预演确定合理尺寸的假体,固定股骨远端与假体的接触面作为截骨平面,以该平面为基准逐步装配其他部件。3D打印设备模型输入格式为病理性股骨标准模板库(STL),采用选择性激光烧结(SLS)技术生产截骨导板,打印主体材料为聚十二内酰胺(PA12)。制造成品灭菌消毒后,于2019年至2021年用于3例因严重骨关节炎实施的截骨手术,其中男性2例,女性1例;患处位于左侧1例,右侧2例;年龄54~67岁,平均年龄59岁。术中医生严格按照截骨导板使用指南实施截骨手术。统计术中和术后失血量、手术时间、髋膝踝角、胫股角、美国膝关节协会评分(AKS)与美国特种外科医院(HSS)膝关节功能评分对手术结果进行评估。结果成功打印制造截骨导板,主要尺寸:固定钉钉孔到截骨平面的垂直距离10.17~12.51 mm,前髁固定钉钉孔直径3.18 mm;截骨槽宽度1.42 mm,固定钉中心点距离45.44 mm,固定钉钉孔直径3.16 mm。临床试用表明,在截骨手术中使用截骨导板定位股骨远端面,切面呈规则“8”字形状,无明显过切或少切现象,能保证截骨的准确性。未发生摆锯与截骨导板干涉或截骨导板破裂等需要中断手术的事件。术后患者膝关节功能恢复良好,随访过程中未出现假体松动、下沉、膝内外翻畸形、移位、股骨端骨折、脂肪栓塞等不良反应。结论实验研究设计制造的截骨导板能够准确定位,相较于普通截骨工具具有无需开髓、一次安装、多次定位的功能。基于3D打印技术的手术预演有利于医生术前根据患者骨形确定假体规格,提前熟悉截骨参数,预估手术难度,考虑术中可能出现的各种问题,从而制订适合患者的个体化、最优化手术方案。展开更多
文摘BACKGROUND Hemophilia A is a rare inherited bleeding disorder caused by mutations in the factor Ⅷ gene. This clotting factor plays an intrinsic role in the blood coagulation pathway. Patients with hemophilia may develop orthopedic manifestations such as hemarthrosis, but multiple malunion of fractures over the knee is rare and difficult to treat.CASE SUMMARY We report a patient with hemophilia A who developed severe knee osteoarthritis along with fracture malunion and nonunion. Total knee replacement was performed using a custom-made modular hinged knee prosthesis(cemented) equipped with extended distal and proximal stems. At 3 years’ follow-up, the patient exhibited excellent clinical function and remained satisfied with the surgical outcome. Surgical intervention was accompanied by rigorous coagulation factor replacement.CONCLUSION This case highlights various unique scenarios specific to individuals with hemophilia and fracture deformity.
文摘At present,most total knee replacement(TKR)prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A number of reports have indicated that Chinese TKR patients do not match with available prostheses.In this study,computed tomography(CT)images of 52 knees of Chinese men and women were used for anthropometric measurements.Index and geometric measurements were definedand used for correlation analysis.Key parameters from the measurement results were identified.Detailed geometries of knees were measured as coordinates.A deformable three-dimensional(3D)knee modelbased on anatomical coordinates correlating with the identified key parameters was generated.A pros-thesis was then designed according to the analyzed results.Surface matching analysis,bone resectionanalysis,and cadaveric trials were conducted and compared with commercial products to validate theproposed design.The femoral component designed by this study resulted in the highest accuracy(rootmean square point-to-surface(RMS PS),(1.08±0.20)mm)and lowest amount of resected bone volume(27412mm^(3))in comparison with two commercial knee prostheses.This study suggests a new approachfor population-based patient-specific femoral prosthesis design With a single,easilty acquired dimen-sion-namely,epicondyle width(ECW)-as input,a patient-specific femoral prosthesis can be designed according to the analyzed measured data and manufactured by additive manufacturing(AM)methods.Meanwhile,the reconstructed femoral condylar surface was compared with the femoral condylar surfacein the original CT scanning data The average RMS PS distance of the reconstructed femoral condylar surface among all data was(1.10±0.18)mm,which is comparable to other statistical shape modeling methods using multiple radiographs as input data.There is a need to develop an anthropometric-based knee prosthesis for the Chinese population.Based on the anthropometry of the Chinese population,our new design fits Chinese patients better and reserves more bone volume compared with current commercial prostheses,which is an essential step toward AM for personalized knee prostheses.
文摘There are several prosthetic knee designs currently in use. There are however very few studies comparing long-term functional outcomes between patients using different models of knee pros-thesis in elective knee replacement. In this study, we used the validated Oxford Knee Score (OKS) to retrospectively compare the outcomes of a total of 1635 patients who had an elective total knee replacement in a large District General Hospital, using fifteen different models of knee prosthesis, over a ten-year period. The average scores reported by all patient groups showed significant improvement by three months post-operatively (pre-operative mean score 15.8, post-operative mean score 39.4, p < 0.05), and remained similar for all models of prosthesis used over the total ten-year period. Based on the OKS as an assessment tool, we report no significant difference in long-term functional outcomes for this group of patients following an elective knee replacement, regardless of the type of prosthesis used.
文摘Negative-pressure wound therapy(NPWT) has been a successful modality of wound management which is in widespread use in several surgical fields. The main mechanisms of action thought to play a role in enhancing wound healing and preventing surgical site infection are macrodeformation and microdeformation of the wound bed, fluid removal, and stabilization of the wound environment. Due to the devastating consequences of infection in the setting of joint arthroplasty, there has been some interest in the use of NPWT following total hip arthroplasty and total knee arthroplasty. However, there is still a scarcity of data reporting on the use of NPWT within this field and most studies are limited by small sample sizes, high variability of clinical settings and end-points. There is little evidence to support the use of NPWT as an adjunctive treatment for surgical wound drainage, and for this reason surgical intervention should not be delayed when indicated. The prophylactic use of NPWT after arthroplasty in patients that are at high risk for postoperative wound drainage appears to have the strongest clinical evidence. Several clinical trialsincluding single-use NPWT devices for this purpose are currently in progress and this may soon be incorporated in clinical guidelines as a mean to prevent periprosthetic joint infections.