As an important part of water level warning in water conservancy projects,often due to the influence of environmental factors such as light and stains,the acquired water gauge images have sticky,broken and bright spot...As an important part of water level warning in water conservancy projects,often due to the influence of environmental factors such as light and stains,the acquired water gauge images have sticky,broken and bright spot conditions,which affect the identification of water gauges.To solve this problem,a water gauge image denoising model based on improved adaptive total variation is proposed.Firstly,the regular term exponent in the adaptive total variational equation is changed to an inverse cosine function;secondly,the differential curvature is used to distinguish the image noise points and increase the smoothing strength at the noise points;finally,according to the characteristics of the gradient mode and adaptive gradient threshold after Gaussian filtering,the New model can adaptively denoise in the smooth area and protect the edge area,so as to have the characteristics of both edge-preserving denoising.The experimental results show that the new model has a great improvement in image vision,higher iteration efficiency and an average increase of 1.6 dB in peak signal-to-noise ratio,and an average increase of 9%in structural similarity,which is more beneficial to practical applications.展开更多
Total dissolved nitrogen(TDN) is an important parameter for assessing the nutrient cycling and status of natural waters.The accurate determination of TDN in natural waters is essential for assessing its contents and d...Total dissolved nitrogen(TDN) is an important parameter for assessing the nutrient cycling and status of natural waters.The accurate determination of TDN in natural waters is essential for assessing its contents and distinguishing different forms of nitrogen in the water.The TDN in various systems has been largely documented,and the concentrations of TDN are usually obtained using high-temperature catalytic(HTC) or persulfate oxidation(PO).However,the accuracy of these methods and their suitability for all types of natural waters are still unclear.To explore both methods in-depth,assorted samples were tested,including eight solutions composed of nitrogen-containing compounds(3 dissolved inorganic nitrogen fractions:NO_(3)^(-),NO_(2)^(-)and NH_(4)^(+);5 organic compounds:EDTA-2Na,vitamin B1,vitamin B12,amino acids,and urea) and 105 natural waters which were collected from an open ocean(Northwest Pacific Ocean,28),a marginal sea(Yellow Sea,34),an estuary(Huanghe River mouth,31),rivers(Huanghe River,4;Licun River,4),and precipitations(4 samples).The results showed that heterocycles and molecular dimensions had certain effects on the oxidation efficiency of the PO method but had little effect on HTC.There was no significant difference between the two methods for natural waters,but HTC was more suitable for deep-sea samples with low TDN concentrations(less than 10 μmol/L) and low organic activity.Overall,HTC has a relatively simple measurement process,a high degree of automation,and low error.Therefore,HTC can be recommended to determine the TDN of samples in freshwater and seawater.展开更多
The Uranium-238 (<sup>238</sup>U), Thorium-232 (<sup>232</sup>Th) families and Potassium-40 (<sup>40</sup>K) are of terrestrial origin and contribute generally to an individual’s e...The Uranium-238 (<sup>238</sup>U), Thorium-232 (<sup>232</sup>Th) families and Potassium-40 (<sup>40</sup>K) are of terrestrial origin and contribute generally to an individual’s external exposure through our presence in this environment. They also contribute to the internal exposure through the ingestion of products and beverages such as water that are close to the earth. The aim of this work is to determine the committed effective dose or Total Indicative Dose (TID) due to gamma radioactivity of the borehole water from the Nord Riviera (NR) well field operated by the Côte d’Ivoire Water Distribution Company (SODECI) for the supply of drinking water to part of the population of Abidjan. In addition, the populations, with their habits, could use these borehole waters directly as drinking water. To this end, water samples from the seven (07) functional boreholes were collected and analyzed on a gamma spectrometry chain, equipped with an HPGe detector in the laboratory of the Radiation Protection Institute (RPI) of the GHANA Atomic Energy Commission (GAEC). The results of the specific activities of <sup>238</sup>U, <sup>232</sup>Th and <sup>40</sup>K obtained were transcribed into TID. As the natural radioactivity of the borehole water is high [1], the TIDs calculated from the activity results of the natural radionuclides<sup>238</sup>U, <sup>232</sup>Th, and <sup>40</sup>K vary for the seven boreholes from 0.150 to 0.166 mSv/yr with an average of 0.161 ± 0.034 mSv/yr. The TID of the control tower, where the borehole water is mixed and treated for household use, is equal to 0.136 ± 0.03 mSv/yr. The TIDs obtained are therefore all slightly greater than the WHO reference dose value of 0.1 mSv/yr. But all remain below the UNSCEAR reference dose of 0.29 mSv/yr.展开更多
Produced water (PW) is the largest waste stream in the oil and gas industry. Water remains trapped for millions of years in the reservoir with oil and gas. When a hydrocarbon reservoir is infiltrated by a production w...Produced water (PW) is the largest waste stream in the oil and gas industry. Water remains trapped for millions of years in the reservoir with oil and gas. When a hydrocarbon reservoir is infiltrated by a production well, the produced fluids commonly contain water. The understanding of this water’s constituents and volumes is vital for the sustainable continuity of production operations, as PW has a number of negative impacts on the infrastructure integrity of the operation. On the other hand, PW can be an alternative source of irrigation water as well as of industrial salt. Interestingly, both the quantity as well as the quality of PW do not remain constant but can vary, both progressively and erratically, even over short periods of time. This paper discusses such a situation of variable PW in an oil and gas operation in the State of Kuwait.展开更多
Groundwater is increasingly being used due to its universal availability and generally good quality. However, the risk of contamination of groundwater due to various human activities such as mining is equally increasi...Groundwater is increasingly being used due to its universal availability and generally good quality. However, the risk of contamination of groundwater due to various human activities such as mining is equally increasing across the globe. In this study, the physical parameters of potable well waters in the key mining areas in Nimikoro and Tankoro Chiefdoms in Kono District were analyzed for compliance with drinking water quality standard. To do this, both unpurged and purged well water samples were collected once every month for a period of one year. Some of the well water properties like temperature, Total Dissolved Solids (TDS) and Electrical Conductivity (EC) were measured on site and others determined in the laboratory. The data collected from the laboratory analyses were statistically analyzed in MS Excel, SPSS and ArcGIS environments for quality trends in time-space fabric. The results showed that well water quality in the study area generally fell short of drinking water quality standards of Sierra Leone and WHO. There were high temperature and turbidity during the dry season and then high TDS and EC during the rainy season. Temperature and turbidity also significantly influenced well water quality in the study area, much more than TDS and EC. The implications for drinking water of lower quality than the standard could be huge for the local population and therefore needs the attention of stakeholders in the study area and decision makers in the country.展开更多
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
This study investigates the use of dynamic a priori error information according to atmospheric moistness and the use of quality controls in temperature and water vapor profile retrievals from hyperspectral infrared ...This study investigates the use of dynamic a priori error information according to atmospheric moistness and the use of quality controls in temperature and water vapor profile retrievals from hyperspectral infrared (IR) sounders. Temperature and water vapor profiles are retrieved from Atmospheric InfraRed Sounder (AIRS) radiance measurements by applying a physical iterative method using regression retrieval as the first guess. Based on the dependency of first-guess errors on the degree of atmospheric moistness, the a priori first-guess errors classified by total precipitable water (TPW) are applied in the AIRS physical retrieval procedure. Compared to the retrieval results from a fixed a priori error, boundary layer moisture retrievals appear to be improved via TPW classification of a priori first-guess errors. Six quality control (QC) tests, which check non-converged or bad retrievals, large residuals, high terrain and desert areas, and large temperature and moisture deviations from the first guess regression retrieval, are also applied in the AIRS physical retrievals. Significantly large errors are found for the retrievals rejected by these six QCs, and the retrieval errors are substantially reduced via QC over land, which suggest the usefulness and high impact of the QCs, especially over land. In conclusion, the use of dynamic a priori error information according to atmospheric moistness, and the use of appropriate QCs dealing with the geographical information and the deviation from the first-guess as well as the conventional inverse performance are suggested to improve temperature and moisture retrievals and their applications.展开更多
Objective Doubly labeled water (DLW) method is the gold standard for measuring total energy expenditure (TEE). We used this method to measure TEE in Chinese young men. Methods Sixteen healthy young men age 23±...Objective Doubly labeled water (DLW) method is the gold standard for measuring total energy expenditure (TEE). We used this method to measure TEE in Chinese young men. Methods Sixteen healthy young men age 23±1 recruited. TEE was measured by the DLW method, by indirect calorimetry. We also conducted 24-h estimate energy requirements of the subjects. years with body mass index 22.0±1.4 kg/m2 were and basal energy expenditure (BEE) was determined activity, energy balance and factorial approach to Results TEE of subjects by DLW method was 9.45±0.57 M J/day (2258±180 kcal/day). The 24-h activity was 10.80±0.33 M J/day (2582±136 kcal/day). The energy requirement, derived from energy balance observations, was 9.93±1.32 M J/day (2373±315 kcal/day). The BEE of 6.65±0.28 M J/day (1589±67 kcal/day), calculated by the adjusted Schofield equation, was significantly higher (P〈O.O01) than that measured by indirect calorimetry, 5.99-±0.66 M J/day (1433-±158 kcal/day). The TEE derived from the factorial approach was 10.31-±0.43 M J/day (2463±104 kcal/day). Conclusion The TEE of Chinese young men measured by the DLW method was about 10% lower than the current recommended nutrient intake (RNI), suggesting that the RNI for Chinese men maybe overestimated. Further studies are warranted to determine the value of the estimated energy requirement.展开更多
Objective: To ascertain the influence of light intensity and water content of medium on the total dendrobine of Dendrobium nobile(D. nobile).Method: The principal component analysis combined with total dendrobine accu...Objective: To ascertain the influence of light intensity and water content of medium on the total dendrobine of Dendrobium nobile(D. nobile).Method: The principal component analysis combined with total dendrobine accumulation was conducted to assess the yield and quality of D. nobile in all treatments. In the experiment, D. nobile plants were cultivated in greenhouse as tested materials, and complete test of 9 treatments was adopted with relative light intensities 75.02%, 39.74%,29.93% and relative water content of medium 50%, 65%, 80%. The plants were treated in June and harvested till December. Indexes including agronomic traits, fresh weight and dry weight of stem and leaf, ash content, extract, and dendrobine were measured.Results: Under the light intensity treatments of 75.02% with 50%, 65%, 80% water content of medium, the basal stems of plants were comparatively thicker with more leaves, and the fresh weight and dry weight of stems and leaves were significantly higher than other 6 treatments.Leaves in all treatments contained dendrobine. Under the light intensity treatments of 75.02%with 50%, 65%, 80% water content of medium, dendrobine content of leaves was lower while dendrobine contents of other treatments were more than 0.60%. After comprehensive assessment through the principal component analysis and total dendrobine accumulation, the results showed that 3 treatments with relative light intensity of 75.02% ranked the top three.Conclusions: In brief, the moderately strong light intensity and water content of medium from low to medium can facilitate the growth and yield of D. nobile plants, while light intensity from moderately weak to weak can enhance the dendrobine content.展开更多
More and more high dams have been constructed and operated in China. The total dissolved gas (TDG) supersaturation caused by dam discharge leads to gas bubble disease or even death of fish, Through a series of exper...More and more high dams have been constructed and operated in China. The total dissolved gas (TDG) supersaturation caused by dam discharge leads to gas bubble disease or even death of fish, Through a series of experiments, the conditions and requirements of supersaturated TDG generation were examined in this study. The results show that pressure (water depth), aeration, and bubble dissolution time are required for supersaturated TDG generation, and the air-water contact area and turbulence intensity are the main factors that affect the generation rate of supersaturated TDG. The TDG supersaturation levels can be reduced by discharging water to shallow shoals downstream of the dam or using negative pressure pipelines. Furthermore, the TDG supersaturation levels in stilling basins have no direct relationship with those in reservoirs. These results are of great importance for further research on the prediction of supersaturated TDG generation caused by dam discharge and aquatic protection.展开更多
This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coil in drinking water samples with a standard membrane filtration procedure. T...This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coil in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coil, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coil with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.展开更多
Photosynthetically active radiation (PAR) is an important input parameter for estimating plant produc- tivity due to its key role in the growth and development of plants. However, a worldwide routine network for sys...Photosynthetically active radiation (PAR) is an important input parameter for estimating plant produc- tivity due to its key role in the growth and development of plants. However, a worldwide routine network for sys- tematic PAR measurements is not yet established, and PAR is often calculated as a constant fraction of total solar radiation (SR). Although the ratio of PAR to SR (PAR/SR) has been reported from many places, few studies have been performed for dry regions. The present study was therefore carried out in an arid region of Mongolia to obtain PAP-JSR and examine its dependency on sky clearness (the clearness index), water vapor in the atmosphere and aeolian dust. Continuous measurements of PAR and SR were taken every one second using quantum and pyranometer sensors, respectively, and the readings were averaged and recorded at intervals of 30 minutes for a period of 12 months. The lowest monthly mean daily PAR/SR occurred in April (0.420), while the highest ratio was observed in July (0.459). Mean daily PAR/SR during plant growing season (May-August) was estimated to be 0.442, which could be useful for modeling plant productivity in the study area. The annual mean daily PAR/SR (0.435) was lower than the values reported in many previous studies. This difference could be explained with the regional variation in climate: i.e. drier climatic condition in the study area. PAR/SR was negatively correlated with the clearness index (r= -0.36, P〈0.001), but positively with atmospheric water vapor pressure (r=0.47, P〈0.001). The average PAR/SR was significantly lower (P=0.02) on the dusty days compared to the non-dust days. Water vapor in the atmosphere was shown to be the strongest factor in the variation of PAR/SR. This is the first study examining PAR/SR under a semi-arid condition in Mongolia.展开更多
Guan River Estuary and adjacent coastal area(GREC) suffer from serious pollution and eutrophicational problems over the recent years.Thus,reducing the land-based load through the national pollutant total load control ...Guan River Estuary and adjacent coastal area(GREC) suffer from serious pollution and eutrophicational problems over the recent years.Thus,reducing the land-based load through the national pollutant total load control program and developing hydrodynamic and water quality models that can simulate the complex circulation and water quality kinetics within the system,including longitudinal and lateral variations in nutrient and COD concentrations,is a matter of urgency.In this study,a three-dimensional,hydrodynamic,water quality model was developed in GREC,Northern Jiangsu Province.The complex three-dimensional hydrodynamics of GREC were modeled using the unstructured-grid,finite-volume,free-surface,primitive equation coastal ocean circulation model(FVCOM).The water quality model was adapted from the mesocosm nutrients dynamic model in the south Yellow Sea and considers eight compartments:dissolved inorganic nitrogen,soluble reactive phosphorus(SRP),phytoplankton,zooplankton,detritus,dissolved organic nitrogen(DON),dissolved organic phosphorus(DOP),and chemical oxygen demand.The hydrodynamic and water quality models were calibrated and confirmed for 2012 and 2013.A comparison of the model simulations with extensive dataset shows that the models accurately simulate the longitudinal distribution of the hydrodynamics and water quality.The model can be used for total load control management to improve water quality in this area.展开更多
Satellite retrieval of atmospheric water vapor is intended to further understand the role played by the energy and water cycle to determine the Earth's weather and climate.The algorithm for operational retrieval o...Satellite retrieval of atmospheric water vapor is intended to further understand the role played by the energy and water cycle to determine the Earth's weather and climate.The algorithm for operational retrieval of total precipitable water (TPW) from the visible and infrared radiometer (VIRR) onboard Fengyun 3A (FY-3A) employs a split window technique for clear sky radiances over land and oceans during both day and night.The retrieved TPW is compared with that from the moderate resolution imaging spectroradiometer (MODIS) onboard the Terra satellite and data from radiosonde observations (RAOB).During the study period,comparisons show that the FY-3A TPW is in general agreement with the gradients and distributions from the Terra TPW.Their zonal mean difference over East Asia is smaller in the daytime than at night,and the main difference occurs in the complex terrain at mid latitude near 30°N.Compared with RAOB,the zonal FY-3A and the Terra TPW have a moist bias at low latitudes and a dry bias at mid and high latitudes;in addition,the FY-3A TPW performs slightly better in zonal mean biases and the diurnal cycle.The temporal variation of the FY-3A and the Terra TPW generally fits the RAOB TPW with the FY-3A more accurate at night while Terra TPW more accurate during the daytime.Comparisons of correlations,root mean square differences and standard deviations indicate that the FY-3A TPW series is more consistent with the RAOB TPW at selected stations.As a result,the FY-3A TPW has some advantages over East Asia in both spatial and temporal dimensions.展开更多
This study was conducted during Dec2011-Nov2012 on three stations located in the south sector of Main Outfall Drain (MOD) River. Station 1 was near Al-Holandee Bridge which was the general carriage way in the center o...This study was conducted during Dec2011-Nov2012 on three stations located in the south sector of Main Outfall Drain (MOD) River. Station 1 was near Al-Holandee Bridge which was the general carriage way in the center of Al-Nassiriya city, station 2 was 20 km far from the first station, while station 3 was in the beginning of the new branch. This study reveals the Seasonal Variation of Total petroleum hydrocarbons (TPHs) in both surface waters, sediment and it is related with trace metals nickel and vanadium in water (dissolved, particulate) and sediment (residual and exchangeable) phases. Also, the study shows the relationships between the concentration of Ni and V with Total Organic Carbon (TOC%) in the sediment.展开更多
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri...Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.展开更多
Indirect detection of Escherichia coli and total coliforms can be based on the enzymatic activities of β-glucuronidase (β-glu) and β-galactosidase (β-gal). These enzymes utilize the substrates anthracene-β-d-gluc...Indirect detection of Escherichia coli and total coliforms can be based on the enzymatic activities of β-glucuronidase (β-glu) and β-galactosidase (β-gal). These enzymes utilize the substrates anthracene-β-d-glucuronide and pyrene d-galactopyranoside, respectively. Substrate cleavage by the enzyme releases the soluble fluorescent molecules 2-hydroxyanthracene and 1-hydroxypyrene, which can then be detected by a fluorometer. The Pathogen Detect? system is an automated portable unit that can measure fluorescent enzyme products. In this report, we investigated the utility of the Pathogen Detect? system for potential automation of water quality monitoring. The PDS unit has the ability to detect E. coli, mean 14.7 h at a standard deviation of 1.5, when the sample mean is 9.1 cells in 100 mL with a standard deviation of 12.6. Similarly, total coliforms may be detected at mean 14.7 h with a standard deviation of 1.4 when the sample mean is 59.6 cells in 100 mL, with a standard deviation of 144.5. The PDS unit has the ability to detect single cells of either total coliforms or E. coli in 100 mL water sample within 18 hours. Turbidity and color of water samples have no impact on the detection of E. coli and total coliforms.展开更多
Effects of conservation methods of water samples on determination of total phosphorus were analyzed from aspects of methods of adding conserving agent, SS concentration, natural sedimentation time, conservation temper...Effects of conservation methods of water samples on determination of total phosphorus were analyzed from aspects of methods of adding conserving agent, SS concentration, natural sedimentation time, conservation temperature and time. The results showed that SS concentration in water and natural sedimentation time had the greatest impact on the determination of total phosphorus, while the influence of methods of adding conserving agent, conservation temperature and time was relatively smaller. TP concentration in water samples conserved irregularly was higher than the standard value due to the existence of SS and microorganisms in water, and the deviation became larger with the increase of SS concentration in water. In addition, quality control measures and matters needing attention during the conservation process of water samples were put forward to improve the accuracy of TP concentration.展开更多
The purpose of this study was to use the measurement of the PAEE taken from Actiheart in order to calculate the TEE in Costa Rican schoolchildren, and at the same time, to determine the effectiveness when it is compar...The purpose of this study was to use the measurement of the PAEE taken from Actiheart in order to calculate the TEE in Costa Rican schoolchildren, and at the same time, to determine the effectiveness when it is compared against the TEE obtained by the DLW. A total of sixteen male schoolchildren were measured for their total daily energy expenditure (TEE) with the doubly labeled water (DLW) technique. The TEE obtained by the Actiheart monitor was calculated and validated against the DWL. The TEE was obtained adding the physical activity energy expenditure given by the Actiheart, plus the basal metabolic rate, and the energy cost of growth. The Pearson’s product‐moment correlation coefficient and the paired t‐test sample were measured in order to identify the association of the data and to evidence the differences between both measurements of TEE respectively. The Lin’s concordance correlation coefficient and the Bland-Altman plot evaluated the concordance of both methods. The correlation between the TEE obtained by DLW and the one calculated by Actiheart was r = 0.97, P < 0.001. The paired t-test showed no significant differences between both methods. Lin’s concordance correlation coefficient was Cb = 0.99, classified as almost perfect. The study validated the TEE calculated with Actiheart against the TEE measured by the DLW.展开更多
Based on the fundamental principles of total amount control of water use, the harmony theory was used in this study to develop a concept of the degree of harmony of total amount control of water use. Based on this con...Based on the fundamental principles of total amount control of water use, the harmony theory was used in this study to develop a concept of the degree of harmony of total amount control of water use. Based on this concept, the harmoniousness of total amount control of water use was analyzed in terms of the supply and demand of water resources, water resources management, water use benefits, and water-saving level. An evaluation index system of the degree of harmony of total amount control of water use was established, and a method for calculation of the degree of harmony of total amount control of water use was developed based on the analytic hierarchy process (AHP) and fuzzy comprehensive analysis (FCA) methods. The new evaluation index system was applied to a certain area in Jiangsu Province, China. The degree of harmony of total amount control of water use over this area was calculated for different years. Results indicate that the evaluation index system and calculation method proposed in this study are feasible, and such a harmoniousness analysis can provide scientific references for the strict water resources management system that will be implemented in China in the near future.展开更多
文摘As an important part of water level warning in water conservancy projects,often due to the influence of environmental factors such as light and stains,the acquired water gauge images have sticky,broken and bright spot conditions,which affect the identification of water gauges.To solve this problem,a water gauge image denoising model based on improved adaptive total variation is proposed.Firstly,the regular term exponent in the adaptive total variational equation is changed to an inverse cosine function;secondly,the differential curvature is used to distinguish the image noise points and increase the smoothing strength at the noise points;finally,according to the characteristics of the gradient mode and adaptive gradient threshold after Gaussian filtering,the New model can adaptively denoise in the smooth area and protect the edge area,so as to have the characteristics of both edge-preserving denoising.The experimental results show that the new model has a great improvement in image vision,higher iteration efficiency and an average increase of 1.6 dB in peak signal-to-noise ratio,and an average increase of 9%in structural similarity,which is more beneficial to practical applications.
基金The National Key Research and Development Project of China under contract No.2019YFC1407802the Fund of State Environmental Protection Key Laboratory of Coastal Ecosystem under contract No.202112+3 种基金the Open Fund of Key Laboratory of Marine Ecological Environment Science and EngineeringMinistry of Natural Resources under contract No.MESE-2019-06the National Natural Science Foundation of China under contract No.41876078the Shandong Provincial Natural Science Foundation of China under contract No.ZR2018MD016。
文摘Total dissolved nitrogen(TDN) is an important parameter for assessing the nutrient cycling and status of natural waters.The accurate determination of TDN in natural waters is essential for assessing its contents and distinguishing different forms of nitrogen in the water.The TDN in various systems has been largely documented,and the concentrations of TDN are usually obtained using high-temperature catalytic(HTC) or persulfate oxidation(PO).However,the accuracy of these methods and their suitability for all types of natural waters are still unclear.To explore both methods in-depth,assorted samples were tested,including eight solutions composed of nitrogen-containing compounds(3 dissolved inorganic nitrogen fractions:NO_(3)^(-),NO_(2)^(-)and NH_(4)^(+);5 organic compounds:EDTA-2Na,vitamin B1,vitamin B12,amino acids,and urea) and 105 natural waters which were collected from an open ocean(Northwest Pacific Ocean,28),a marginal sea(Yellow Sea,34),an estuary(Huanghe River mouth,31),rivers(Huanghe River,4;Licun River,4),and precipitations(4 samples).The results showed that heterocycles and molecular dimensions had certain effects on the oxidation efficiency of the PO method but had little effect on HTC.There was no significant difference between the two methods for natural waters,but HTC was more suitable for deep-sea samples with low TDN concentrations(less than 10 μmol/L) and low organic activity.Overall,HTC has a relatively simple measurement process,a high degree of automation,and low error.Therefore,HTC can be recommended to determine the TDN of samples in freshwater and seawater.
文摘The Uranium-238 (<sup>238</sup>U), Thorium-232 (<sup>232</sup>Th) families and Potassium-40 (<sup>40</sup>K) are of terrestrial origin and contribute generally to an individual’s external exposure through our presence in this environment. They also contribute to the internal exposure through the ingestion of products and beverages such as water that are close to the earth. The aim of this work is to determine the committed effective dose or Total Indicative Dose (TID) due to gamma radioactivity of the borehole water from the Nord Riviera (NR) well field operated by the Côte d’Ivoire Water Distribution Company (SODECI) for the supply of drinking water to part of the population of Abidjan. In addition, the populations, with their habits, could use these borehole waters directly as drinking water. To this end, water samples from the seven (07) functional boreholes were collected and analyzed on a gamma spectrometry chain, equipped with an HPGe detector in the laboratory of the Radiation Protection Institute (RPI) of the GHANA Atomic Energy Commission (GAEC). The results of the specific activities of <sup>238</sup>U, <sup>232</sup>Th and <sup>40</sup>K obtained were transcribed into TID. As the natural radioactivity of the borehole water is high [1], the TIDs calculated from the activity results of the natural radionuclides<sup>238</sup>U, <sup>232</sup>Th, and <sup>40</sup>K vary for the seven boreholes from 0.150 to 0.166 mSv/yr with an average of 0.161 ± 0.034 mSv/yr. The TID of the control tower, where the borehole water is mixed and treated for household use, is equal to 0.136 ± 0.03 mSv/yr. The TIDs obtained are therefore all slightly greater than the WHO reference dose value of 0.1 mSv/yr. But all remain below the UNSCEAR reference dose of 0.29 mSv/yr.
文摘Produced water (PW) is the largest waste stream in the oil and gas industry. Water remains trapped for millions of years in the reservoir with oil and gas. When a hydrocarbon reservoir is infiltrated by a production well, the produced fluids commonly contain water. The understanding of this water’s constituents and volumes is vital for the sustainable continuity of production operations, as PW has a number of negative impacts on the infrastructure integrity of the operation. On the other hand, PW can be an alternative source of irrigation water as well as of industrial salt. Interestingly, both the quantity as well as the quality of PW do not remain constant but can vary, both progressively and erratically, even over short periods of time. This paper discusses such a situation of variable PW in an oil and gas operation in the State of Kuwait.
文摘Groundwater is increasingly being used due to its universal availability and generally good quality. However, the risk of contamination of groundwater due to various human activities such as mining is equally increasing across the globe. In this study, the physical parameters of potable well waters in the key mining areas in Nimikoro and Tankoro Chiefdoms in Kono District were analyzed for compliance with drinking water quality standard. To do this, both unpurged and purged well water samples were collected once every month for a period of one year. Some of the well water properties like temperature, Total Dissolved Solids (TDS) and Electrical Conductivity (EC) were measured on site and others determined in the laboratory. The data collected from the laboratory analyses were statistically analyzed in MS Excel, SPSS and ArcGIS environments for quality trends in time-space fabric. The results showed that well water quality in the study area generally fell short of drinking water quality standards of Sierra Leone and WHO. There were high temperature and turbidity during the dry season and then high TDS and EC during the rainy season. Temperature and turbidity also significantly influenced well water quality in the study area, much more than TDS and EC. The implications for drinking water of lower quality than the standard could be huge for the local population and therefore needs the attention of stakeholders in the study area and decision makers in the country.
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
基金supported by GOES-R Algorithm Working Group Program and GOES-R High Impact Weather Project (Grant No NA10NES4400013)supported by the Korea Meteorological Administration Research and Development Program under Grant CATER 2006-2103the BK21 Project of the Korean Government
文摘This study investigates the use of dynamic a priori error information according to atmospheric moistness and the use of quality controls in temperature and water vapor profile retrievals from hyperspectral infrared (IR) sounders. Temperature and water vapor profiles are retrieved from Atmospheric InfraRed Sounder (AIRS) radiance measurements by applying a physical iterative method using regression retrieval as the first guess. Based on the dependency of first-guess errors on the degree of atmospheric moistness, the a priori first-guess errors classified by total precipitable water (TPW) are applied in the AIRS physical retrieval procedure. Compared to the retrieval results from a fixed a priori error, boundary layer moisture retrievals appear to be improved via TPW classification of a priori first-guess errors. Six quality control (QC) tests, which check non-converged or bad retrievals, large residuals, high terrain and desert areas, and large temperature and moisture deviations from the first guess regression retrieval, are also applied in the AIRS physical retrievals. Significantly large errors are found for the retrievals rejected by these six QCs, and the retrieval errors are substantially reduced via QC over land, which suggest the usefulness and high impact of the QCs, especially over land. In conclusion, the use of dynamic a priori error information according to atmospheric moistness, and the use of appropriate QCs dealing with the geographical information and the deviation from the first-guess as well as the conventional inverse performance are suggested to improve temperature and moisture retrievals and their applications.
基金supported by the projects of National Natural Science Foundation of China (No.30771811)the National Technology Research and Development Program in the Eleventh Five-Year Plan of China(No.2008BAI58B01)
文摘Objective Doubly labeled water (DLW) method is the gold standard for measuring total energy expenditure (TEE). We used this method to measure TEE in Chinese young men. Methods Sixteen healthy young men age 23±1 recruited. TEE was measured by the DLW method, by indirect calorimetry. We also conducted 24-h estimate energy requirements of the subjects. years with body mass index 22.0±1.4 kg/m2 were and basal energy expenditure (BEE) was determined activity, energy balance and factorial approach to Results TEE of subjects by DLW method was 9.45±0.57 M J/day (2258±180 kcal/day). The 24-h activity was 10.80±0.33 M J/day (2582±136 kcal/day). The energy requirement, derived from energy balance observations, was 9.93±1.32 M J/day (2373±315 kcal/day). The BEE of 6.65±0.28 M J/day (1589±67 kcal/day), calculated by the adjusted Schofield equation, was significantly higher (P〈O.O01) than that measured by indirect calorimetry, 5.99-±0.66 M J/day (1433-±158 kcal/day). The TEE derived from the factorial approach was 10.31-±0.43 M J/day (2463±104 kcal/day). Conclusion The TEE of Chinese young men measured by the DLW method was about 10% lower than the current recommended nutrient intake (RNI), suggesting that the RNI for Chinese men maybe overestimated. Further studies are warranted to determine the value of the estimated energy requirement.
基金supported by Natural Science Foundation of China(No.81603237)Joint Funding Project of Guizhou Province[QKH LH Zi(2015)No.7670]+4 种基金Youth Science and Technology Talent Development Project of Education Department in Guizhou Province[QJH KY Zi(2016)No.119]Natural Science Foundation of Guizhou Province[QKH Basics(2017)No.1403]Talent Base Project of Organization Department in Guizhou Province[QRLF(2013)No.15]Key Discipline Project of Education Department in Guizhou Province[QXWH Zi ZDXK(2014)No.8]Regular Higher Education Institution Project of Key Laboratory of Genetic Improvement and Physiology and Ecology of Grain and Oil Crops of Guizhou Province of China[Grant No.KY(2015)333]
文摘Objective: To ascertain the influence of light intensity and water content of medium on the total dendrobine of Dendrobium nobile(D. nobile).Method: The principal component analysis combined with total dendrobine accumulation was conducted to assess the yield and quality of D. nobile in all treatments. In the experiment, D. nobile plants were cultivated in greenhouse as tested materials, and complete test of 9 treatments was adopted with relative light intensities 75.02%, 39.74%,29.93% and relative water content of medium 50%, 65%, 80%. The plants were treated in June and harvested till December. Indexes including agronomic traits, fresh weight and dry weight of stem and leaf, ash content, extract, and dendrobine were measured.Results: Under the light intensity treatments of 75.02% with 50%, 65%, 80% water content of medium, the basal stems of plants were comparatively thicker with more leaves, and the fresh weight and dry weight of stems and leaves were significantly higher than other 6 treatments.Leaves in all treatments contained dendrobine. Under the light intensity treatments of 75.02%with 50%, 65%, 80% water content of medium, dendrobine content of leaves was lower while dendrobine contents of other treatments were more than 0.60%. After comprehensive assessment through the principal component analysis and total dendrobine accumulation, the results showed that 3 treatments with relative light intensity of 75.02% ranked the top three.Conclusions: In brief, the moderately strong light intensity and water content of medium from low to medium can facilitate the growth and yield of D. nobile plants, while light intensity from moderately weak to weak can enhance the dendrobine content.
基金supported by the National Natural Science Foundation of China (Grant No. 50979063)
文摘More and more high dams have been constructed and operated in China. The total dissolved gas (TDG) supersaturation caused by dam discharge leads to gas bubble disease or even death of fish, Through a series of experiments, the conditions and requirements of supersaturated TDG generation were examined in this study. The results show that pressure (water depth), aeration, and bubble dissolution time are required for supersaturated TDG generation, and the air-water contact area and turbulence intensity are the main factors that affect the generation rate of supersaturated TDG. The TDG supersaturation levels can be reduced by discharging water to shallow shoals downstream of the dam or using negative pressure pipelines. Furthermore, the TDG supersaturation levels in stilling basins have no direct relationship with those in reservoirs. These results are of great importance for further research on the prediction of supersaturated TDG generation caused by dam discharge and aquatic protection.
文摘This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coil in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coil, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coil with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.
基金supported by the Global Center of Excellence for Dryland Science Program of the Japanese Society for the Promotion of Science
文摘Photosynthetically active radiation (PAR) is an important input parameter for estimating plant produc- tivity due to its key role in the growth and development of plants. However, a worldwide routine network for sys- tematic PAR measurements is not yet established, and PAR is often calculated as a constant fraction of total solar radiation (SR). Although the ratio of PAR to SR (PAR/SR) has been reported from many places, few studies have been performed for dry regions. The present study was therefore carried out in an arid region of Mongolia to obtain PAP-JSR and examine its dependency on sky clearness (the clearness index), water vapor in the atmosphere and aeolian dust. Continuous measurements of PAR and SR were taken every one second using quantum and pyranometer sensors, respectively, and the readings were averaged and recorded at intervals of 30 minutes for a period of 12 months. The lowest monthly mean daily PAR/SR occurred in April (0.420), while the highest ratio was observed in July (0.459). Mean daily PAR/SR during plant growing season (May-August) was estimated to be 0.442, which could be useful for modeling plant productivity in the study area. The annual mean daily PAR/SR (0.435) was lower than the values reported in many previous studies. This difference could be explained with the regional variation in climate: i.e. drier climatic condition in the study area. PAR/SR was negatively correlated with the clearness index (r= -0.36, P〈0.001), but positively with atmospheric water vapor pressure (r=0.47, P〈0.001). The average PAR/SR was significantly lower (P=0.02) on the dusty days compared to the non-dust days. Water vapor in the atmosphere was shown to be the strongest factor in the variation of PAR/SR. This is the first study examining PAR/SR under a semi-arid condition in Mongolia.
基金supported by Natural Science Foundation of China-Shandong Joint Fund for Marine Science Research Centers (Grant No.U1406403)the Sea Area Use Fund of Jiangsu Province (Environmental Capacity for the Key Coast of Jiangsu Province)+1 种基金the National Natural Science Foundation of China (No.41340046)Modeling work was completed at the Computing Services Center,Ocean University of China
文摘Guan River Estuary and adjacent coastal area(GREC) suffer from serious pollution and eutrophicational problems over the recent years.Thus,reducing the land-based load through the national pollutant total load control program and developing hydrodynamic and water quality models that can simulate the complex circulation and water quality kinetics within the system,including longitudinal and lateral variations in nutrient and COD concentrations,is a matter of urgency.In this study,a three-dimensional,hydrodynamic,water quality model was developed in GREC,Northern Jiangsu Province.The complex three-dimensional hydrodynamics of GREC were modeled using the unstructured-grid,finite-volume,free-surface,primitive equation coastal ocean circulation model(FVCOM).The water quality model was adapted from the mesocosm nutrients dynamic model in the south Yellow Sea and considers eight compartments:dissolved inorganic nitrogen,soluble reactive phosphorus(SRP),phytoplankton,zooplankton,detritus,dissolved organic nitrogen(DON),dissolved organic phosphorus(DOP),and chemical oxygen demand.The hydrodynamic and water quality models were calibrated and confirmed for 2012 and 2013.A comparison of the model simulations with extensive dataset shows that the models accurately simulate the longitudinal distribution of the hydrodynamics and water quality.The model can be used for total load control management to improve water quality in this area.
基金supported by the National High Technology Research and Development Program of China(Grant No. 2007AA12Z144)the Professional Projects (Grant Nos.GYHY200706005 and GYHY200906036)the China Meteoro-logical Administration New Technology Promotion Project (GrantNo. CMATG2008Z04)
文摘Satellite retrieval of atmospheric water vapor is intended to further understand the role played by the energy and water cycle to determine the Earth's weather and climate.The algorithm for operational retrieval of total precipitable water (TPW) from the visible and infrared radiometer (VIRR) onboard Fengyun 3A (FY-3A) employs a split window technique for clear sky radiances over land and oceans during both day and night.The retrieved TPW is compared with that from the moderate resolution imaging spectroradiometer (MODIS) onboard the Terra satellite and data from radiosonde observations (RAOB).During the study period,comparisons show that the FY-3A TPW is in general agreement with the gradients and distributions from the Terra TPW.Their zonal mean difference over East Asia is smaller in the daytime than at night,and the main difference occurs in the complex terrain at mid latitude near 30°N.Compared with RAOB,the zonal FY-3A and the Terra TPW have a moist bias at low latitudes and a dry bias at mid and high latitudes;in addition,the FY-3A TPW performs slightly better in zonal mean biases and the diurnal cycle.The temporal variation of the FY-3A and the Terra TPW generally fits the RAOB TPW with the FY-3A more accurate at night while Terra TPW more accurate during the daytime.Comparisons of correlations,root mean square differences and standard deviations indicate that the FY-3A TPW series is more consistent with the RAOB TPW at selected stations.As a result,the FY-3A TPW has some advantages over East Asia in both spatial and temporal dimensions.
文摘This study was conducted during Dec2011-Nov2012 on three stations located in the south sector of Main Outfall Drain (MOD) River. Station 1 was near Al-Holandee Bridge which was the general carriage way in the center of Al-Nassiriya city, station 2 was 20 km far from the first station, while station 3 was in the beginning of the new branch. This study reveals the Seasonal Variation of Total petroleum hydrocarbons (TPHs) in both surface waters, sediment and it is related with trace metals nickel and vanadium in water (dissolved, particulate) and sediment (residual and exchangeable) phases. Also, the study shows the relationships between the concentration of Ni and V with Total Organic Carbon (TOC%) in the sediment.
基金Supported by Leading Academic Discipline Project of Shanghai Municipal Education Commission(J50502)
文摘Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.
文摘Indirect detection of Escherichia coli and total coliforms can be based on the enzymatic activities of β-glucuronidase (β-glu) and β-galactosidase (β-gal). These enzymes utilize the substrates anthracene-β-d-glucuronide and pyrene d-galactopyranoside, respectively. Substrate cleavage by the enzyme releases the soluble fluorescent molecules 2-hydroxyanthracene and 1-hydroxypyrene, which can then be detected by a fluorometer. The Pathogen Detect? system is an automated portable unit that can measure fluorescent enzyme products. In this report, we investigated the utility of the Pathogen Detect? system for potential automation of water quality monitoring. The PDS unit has the ability to detect E. coli, mean 14.7 h at a standard deviation of 1.5, when the sample mean is 9.1 cells in 100 mL with a standard deviation of 12.6. Similarly, total coliforms may be detected at mean 14.7 h with a standard deviation of 1.4 when the sample mean is 59.6 cells in 100 mL, with a standard deviation of 144.5. The PDS unit has the ability to detect single cells of either total coliforms or E. coli in 100 mL water sample within 18 hours. Turbidity and color of water samples have no impact on the detection of E. coli and total coliforms.
文摘Effects of conservation methods of water samples on determination of total phosphorus were analyzed from aspects of methods of adding conserving agent, SS concentration, natural sedimentation time, conservation temperature and time. The results showed that SS concentration in water and natural sedimentation time had the greatest impact on the determination of total phosphorus, while the influence of methods of adding conserving agent, conservation temperature and time was relatively smaller. TP concentration in water samples conserved irregularly was higher than the standard value due to the existence of SS and microorganisms in water, and the deviation became larger with the increase of SS concentration in water. In addition, quality control measures and matters needing attention during the conservation process of water samples were put forward to improve the accuracy of TP concentration.
文摘The purpose of this study was to use the measurement of the PAEE taken from Actiheart in order to calculate the TEE in Costa Rican schoolchildren, and at the same time, to determine the effectiveness when it is compared against the TEE obtained by the DLW. A total of sixteen male schoolchildren were measured for their total daily energy expenditure (TEE) with the doubly labeled water (DLW) technique. The TEE obtained by the Actiheart monitor was calculated and validated against the DWL. The TEE was obtained adding the physical activity energy expenditure given by the Actiheart, plus the basal metabolic rate, and the energy cost of growth. The Pearson’s product‐moment correlation coefficient and the paired t‐test sample were measured in order to identify the association of the data and to evidence the differences between both measurements of TEE respectively. The Lin’s concordance correlation coefficient and the Bland-Altman plot evaluated the concordance of both methods. The correlation between the TEE obtained by DLW and the one calculated by Actiheart was r = 0.97, P < 0.001. The paired t-test showed no significant differences between both methods. Lin’s concordance correlation coefficient was Cb = 0.99, classified as almost perfect. The study validated the TEE calculated with Actiheart against the TEE measured by the DLW.
文摘Based on the fundamental principles of total amount control of water use, the harmony theory was used in this study to develop a concept of the degree of harmony of total amount control of water use. Based on this concept, the harmoniousness of total amount control of water use was analyzed in terms of the supply and demand of water resources, water resources management, water use benefits, and water-saving level. An evaluation index system of the degree of harmony of total amount control of water use was established, and a method for calculation of the degree of harmony of total amount control of water use was developed based on the analytic hierarchy process (AHP) and fuzzy comprehensive analysis (FCA) methods. The new evaluation index system was applied to a certain area in Jiangsu Province, China. The degree of harmony of total amount control of water use over this area was calculated for different years. Results indicate that the evaluation index system and calculation method proposed in this study are feasible, and such a harmoniousness analysis can provide scientific references for the strict water resources management system that will be implemented in China in the near future.