The micro-amount of nickel in MnO2, electrolytical and natural both, was determined by differential pulse polarography. NH4OH-NH4Cl was used as supporting electrolyte. It was found that the peak potential of Ni(II) re...The micro-amount of nickel in MnO2, electrolytical and natural both, was determined by differential pulse polarography. NH4OH-NH4Cl was used as supporting electrolyte. It was found that the peak potential of Ni(II) reduction wave is -1.0V (vs. Ag-AgCl electrode). The presence of great amount of Mn(II) does not interfere in the trace nickel determination. the peak current relationship with the Ni2+ concentration presents a quite fine straight line. The differential pulse polarography is proved that it is a simple, reliable and acceptable method for determination of trace Ni in various species of MnO2.展开更多
A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and opti...A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and optimized. Synthesis was very fast and simple using non polluting solvents; silver chemical reduction was carried out at room temperature. Spectroscopic studies were carried out in order to assure the uniformed of nanomaterial obtained. Fluorescent signal of silver nanoparticles resulted enhanced in presence of Ni(II). At optimal experimental conditions, a detection limit of 0.036 pg'L1 and quantification limit 0.12 pg'L~ were obtained. The calibration sensitivity was 2 x 1014 L.pg-l.cm1 for the new methodology, with a range of linearity of six orders of magnitude between 0.12 and 2.93 × 10^5 pg L^-1. The tolerance levels for potential interferent ions were studied with good results. The proposed methodology represents a promising approach for Ni(II) traces quantification due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents.展开更多
In order to obtain good understanding of complicated beam propagation behaviors in nickel-based alloy weldments , ray tracing simulation is established to predict the ultrasonic beam path in a special welded structure...In order to obtain good understanding of complicated beam propagation behaviors in nickel-based alloy weldments , ray tracing simulation is established to predict the ultrasonic beam path in a special welded structure of dissimilar steels. Also experimental examinations are carried out to measure the ultrasonic beam paths in the weldment. Then comparisons of the modeling predictions with experimental results are presented to reveal the complicated beam propagation behaviors.展开更多
文摘The micro-amount of nickel in MnO2, electrolytical and natural both, was determined by differential pulse polarography. NH4OH-NH4Cl was used as supporting electrolyte. It was found that the peak potential of Ni(II) reduction wave is -1.0V (vs. Ag-AgCl electrode). The presence of great amount of Mn(II) does not interfere in the trace nickel determination. the peak current relationship with the Ni2+ concentration presents a quite fine straight line. The differential pulse polarography is proved that it is a simple, reliable and acceptable method for determination of trace Ni in various species of MnO2.
文摘A new fluorescence silver nanosensor assisted by surfactant has been synthesized and applied to ultra trace nickel determination. Operational variables which influence nanomaterial synthesis have been studied and optimized. Synthesis was very fast and simple using non polluting solvents; silver chemical reduction was carried out at room temperature. Spectroscopic studies were carried out in order to assure the uniformed of nanomaterial obtained. Fluorescent signal of silver nanoparticles resulted enhanced in presence of Ni(II). At optimal experimental conditions, a detection limit of 0.036 pg'L1 and quantification limit 0.12 pg'L~ were obtained. The calibration sensitivity was 2 x 1014 L.pg-l.cm1 for the new methodology, with a range of linearity of six orders of magnitude between 0.12 and 2.93 × 10^5 pg L^-1. The tolerance levels for potential interferent ions were studied with good results. The proposed methodology represents a promising approach for Ni(II) traces quantification due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents.
基金supported by National Natural Science Foundation of China (Grant No. 50775054)International Joint Research Program of China (Grant No. 2007DFR70070)
文摘In order to obtain good understanding of complicated beam propagation behaviors in nickel-based alloy weldments , ray tracing simulation is established to predict the ultrasonic beam path in a special welded structure of dissimilar steels. Also experimental examinations are carried out to measure the ultrasonic beam paths in the weldment. Then comparisons of the modeling predictions with experimental results are presented to reveal the complicated beam propagation behaviors.