The support layer is an important component of twin-block ballastless track. The modulus of the support layer is an important design parameter and must be carefully solved. We studied the bending stress and deformatio...The support layer is an important component of twin-block ballastless track. The modulus of the support layer is an important design parameter and must be carefully solved. We studied the bending stress and deformation of track slab and support layer due to train load using the beam-plate finite element model on elastic foundation. The results show that support layer type has great impact on both support layer deformation and the stress on subgrade, but has little impact on the bending stress of either track slab or support layer. The continuous support layer type, and articulated support layer type with shear transfer device at their ends, are recommended. In order to keep the stress in the support layer less than that in track slab, the modulus of the continuous, unit, and articulated types of support layer ( in unit twin-block ballastless track), and the support layer in continuous twin-block ballastless track, should not be larger than 15, 22, 20.5 and 5 GPa, respectively. In addition, the modulus of the unit-type support layer should not be more than 20 GPa, to ensure the step in support layer remains less than 1 mm.展开更多
A proven beam-track contact model was used to analyze the track-structure interaction of CWR (continuously welded track) on bridge. Considering the impact of adjacent bridges, the tower-cable-track-beam-pier-pile fini...A proven beam-track contact model was used to analyze the track-structure interaction of CWR (continuously welded track) on bridge. Considering the impact of adjacent bridges, the tower-cable-track-beam-pier-pile finite element model of the cable-stayed bridge was established. Taking a bridge group including 40-32m simply-supported beam and (32+80+112)m single-tower cable-stayed bridge and 17-32m simply-supported beam on the Kunming-Shanghai high-speed railway as an example, the characteristics of CWR longitudinal force on the cable-stayed bridge were studied. It is shown that adjacent bridges must be considered in the calculation of the track expansion force and bending force on cable-stayed bridge. When the span amount of adjacent bridges is too numerous, it can be simplified as six spans; the fixed bearing of adjacent simply-supported beams should be placed on the side near the cable-stayed bridge; the track expansion device should be set at the bridge tower to reduce the track force near the bridge abutment.展开更多
基金The National Natural Science Foundation of China(Director Program)(No.50848015)the Innovative Research Team Incubation Financing Projects of Southwest Jiaotong University(No.2007IRT06)
文摘The support layer is an important component of twin-block ballastless track. The modulus of the support layer is an important design parameter and must be carefully solved. We studied the bending stress and deformation of track slab and support layer due to train load using the beam-plate finite element model on elastic foundation. The results show that support layer type has great impact on both support layer deformation and the stress on subgrade, but has little impact on the bending stress of either track slab or support layer. The continuous support layer type, and articulated support layer type with shear transfer device at their ends, are recommended. In order to keep the stress in the support layer less than that in track slab, the modulus of the continuous, unit, and articulated types of support layer ( in unit twin-block ballastless track), and the support layer in continuous twin-block ballastless track, should not be larger than 15, 22, 20.5 and 5 GPa, respectively. In addition, the modulus of the unit-type support layer should not be more than 20 GPa, to ensure the step in support layer remains less than 1 mm.
基金Project(51178469) supported by the National Natural Science Foundation of China
文摘A proven beam-track contact model was used to analyze the track-structure interaction of CWR (continuously welded track) on bridge. Considering the impact of adjacent bridges, the tower-cable-track-beam-pier-pile finite element model of the cable-stayed bridge was established. Taking a bridge group including 40-32m simply-supported beam and (32+80+112)m single-tower cable-stayed bridge and 17-32m simply-supported beam on the Kunming-Shanghai high-speed railway as an example, the characteristics of CWR longitudinal force on the cable-stayed bridge were studied. It is shown that adjacent bridges must be considered in the calculation of the track expansion force and bending force on cable-stayed bridge. When the span amount of adjacent bridges is too numerous, it can be simplified as six spans; the fixed bearing of adjacent simply-supported beams should be placed on the side near the cable-stayed bridge; the track expansion device should be set at the bridge tower to reduce the track force near the bridge abutment.