Transcutaneous electrical nerve stimulation(TENS) has been widely used for sensory feedback which is a key consideration of improving the performance of prosthetic hands. Two-electrode discriminability is the key to r...Transcutaneous electrical nerve stimulation(TENS) has been widely used for sensory feedback which is a key consideration of improving the performance of prosthetic hands. Two-electrode discriminability is the key to realize high-spatial-resolution TENS, but the neural firing mechanism is not clear yet. The goal of this research is to investigate the neural firing patterns under two-electrode stimulation and to reveal the potential mechanisms. A three-dimensional(3 D) model is established by incorporating Aβ fiber neuron clusters into a layered forearm structure. The diameters of the stimulating electrodes are selected as 5, 7, 9 and 12 mm, and the two-electrode discrimination distance(TEDD) is quantified. It is found that a distant TEDD is obtained for a relatively large electrode size, and 7 mm is suggested to be the optimal diameter of stimulating electrodes. The present study reveals the neural firing patterns under two-electrode stimulation by the 3 D TENS model. In order to discriminate individual electrodes under simultaneous stimulation, no crosstalk of activated Aβ fibers exists between two electrodes. This research can further guide the optimization of the electrode-array floorplan.展开更多
目的观察经皮神经电刺激(transcutaneous electric nervous stimulation,TENS)用于玻璃体切除联合眼内填充术后面向下体位患者相关疼痛的临床效果。方法便利抽样选取2018年11-12月某院眼科住院的行玻璃体切除联合硅油或气体填充术后需...目的观察经皮神经电刺激(transcutaneous electric nervous stimulation,TENS)用于玻璃体切除联合眼内填充术后面向下体位患者相关疼痛的临床效果。方法便利抽样选取2018年11-12月某院眼科住院的行玻璃体切除联合硅油或气体填充术后需保持面向下体位患者60例60眼,随机分为观察组和对照组。对照组采用常规护理方法,观察组在常规护理的基础上于术后面向下体位2h后予经皮神经电刺激治疗30min。治疗前后采用面部疼痛评分量表(faces pain scale,FPS)对两组患者相关疼痛进行评分。结果术后面向下体位2.5h,观察组面部疼痛评分量表评分较治疗前及对照组显著降低(均P<0.01)。结论经皮神经电刺激可改善玻璃体切除联合眼内填充术后面向下体位患者的相关疼痛,效果确切,值得临床推广应用。展开更多
Loss of sensory function for upper-limb amputees inevitably devastates their life qualities, and lack of reliable sensory feedback is the biggest defect to sophisticated prosthetic hands, greatly hindering their usefu...Loss of sensory function for upper-limb amputees inevitably devastates their life qualities, and lack of reliable sensory feedback is the biggest defect to sophisticated prosthetic hands, greatly hindering their usefulness and perceptual embodiment. Thus, it is extremely necessary to accomplish an intelligent prosthetic hand with effective tactile sensory feedback for an upper-limb amputee. This paper presents an overview of three kinds of existing sensory feedback approaches, including cutaneous mechanical stimulation(CMS), transcutaneous electrical nerve stimulation(TENS) and direct peripheral nerve electrical stimulation(DPNES). The emphasis concentrates on major scientific achievements, advantages and disadvantages. The TENS on the skin areas with evoked finger sensation(EFS) at upper-limb amputees' residual limbs might be one of the most promising approaches to realize natural sensory feedback.展开更多
基金the National Natural Science Foundation of China(No.81671801)the Innovation Studio Fund from School of Biomedical Engineering at Shanghai Jiao Tong Universitythe Medical-Engineering Cross Project of Shanghai Jiao Tong University(No.YG2017MS53)
文摘Transcutaneous electrical nerve stimulation(TENS) has been widely used for sensory feedback which is a key consideration of improving the performance of prosthetic hands. Two-electrode discriminability is the key to realize high-spatial-resolution TENS, but the neural firing mechanism is not clear yet. The goal of this research is to investigate the neural firing patterns under two-electrode stimulation and to reveal the potential mechanisms. A three-dimensional(3 D) model is established by incorporating Aβ fiber neuron clusters into a layered forearm structure. The diameters of the stimulating electrodes are selected as 5, 7, 9 and 12 mm, and the two-electrode discrimination distance(TEDD) is quantified. It is found that a distant TEDD is obtained for a relatively large electrode size, and 7 mm is suggested to be the optimal diameter of stimulating electrodes. The present study reveals the neural firing patterns under two-electrode stimulation by the 3 D TENS model. In order to discriminate individual electrodes under simultaneous stimulation, no crosstalk of activated Aβ fibers exists between two electrodes. This research can further guide the optimization of the electrode-array floorplan.
基金the National Basic Research Program(973) of China(No.2011CB013304)the Medical-Engineering Cross Project of Shanghai Jiao Tong University(No.YG2013MS76)
文摘Loss of sensory function for upper-limb amputees inevitably devastates their life qualities, and lack of reliable sensory feedback is the biggest defect to sophisticated prosthetic hands, greatly hindering their usefulness and perceptual embodiment. Thus, it is extremely necessary to accomplish an intelligent prosthetic hand with effective tactile sensory feedback for an upper-limb amputee. This paper presents an overview of three kinds of existing sensory feedback approaches, including cutaneous mechanical stimulation(CMS), transcutaneous electrical nerve stimulation(TENS) and direct peripheral nerve electrical stimulation(DPNES). The emphasis concentrates on major scientific achievements, advantages and disadvantages. The TENS on the skin areas with evoked finger sensation(EFS) at upper-limb amputees' residual limbs might be one of the most promising approaches to realize natural sensory feedback.