The inherent unsteady pressure fluctuations on the rotating blade suction surface of an axial compressor were experimentally measured by directly mounting five high response miniature pressure transducers into the rot...The inherent unsteady pressure fluctuations on the rotating blade suction surface of an axial compressor were experimentally measured by directly mounting five high response miniature pressure transducers into the rotor blade along a streamline at 50% span respectively. The results show that the unsteady pressure fluctuations of rotor blade surface could be measured successfully by this means. The relations about the period, altitude of unsteady pressure with rotating speed, the discipline of pressure fluctuation along the streamwise direction were obtained.展开更多
This study deals with the sources of signal distortion of a piezoelectric transducer heated by measured gas flow. These signal distortions originate from both unloading of preload on a piezocrystal because of expansio...This study deals with the sources of signal distortion of a piezoelectric transducer heated by measured gas flow. These signal distortions originate from both unloading of preload on a piezocrystal because of expansion of a diaphragm in the test apparatus and the pyroelectric effect of a heated piezoelectric crystal. A plastic film on the diaphragm of the transducer can effectively insulate the diaphragm and the piezocrystal within transducer from heating by gas flow, eliminating the sources of distortion. A method for evaluating the thickness of the film is proposed.展开更多
文摘The inherent unsteady pressure fluctuations on the rotating blade suction surface of an axial compressor were experimentally measured by directly mounting five high response miniature pressure transducers into the rotor blade along a streamline at 50% span respectively. The results show that the unsteady pressure fluctuations of rotor blade surface could be measured successfully by this means. The relations about the period, altitude of unsteady pressure with rotating speed, the discipline of pressure fluctuation along the streamwise direction were obtained.
基金Supported by the National Natural Science Foundation of China (Grant No. 90605006)
文摘This study deals with the sources of signal distortion of a piezoelectric transducer heated by measured gas flow. These signal distortions originate from both unloading of preload on a piezocrystal because of expansion of a diaphragm in the test apparatus and the pyroelectric effect of a heated piezoelectric crystal. A plastic film on the diaphragm of the transducer can effectively insulate the diaphragm and the piezocrystal within transducer from heating by gas flow, eliminating the sources of distortion. A method for evaluating the thickness of the film is proposed.