期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Over Voltage Fault due to Disconnection of Consumer’s Transformer Neutral Wire
1
作者 Erdene Adiyasuren Enkh-Od Erdene +1 位作者 Sergelen Byambaa Shagdarsuren Gantumur 《Journal of Energy and Power Engineering》 2023年第1期11-14,共4页
Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected fr... Practically,the load currents in three phases are asymmetric in the power system.It means that the impedances are different in all three phases.If the consumer’s transformer neutral cut off and/or was disconnected from the neutral of power supply source,then there will be some trouble and failure occurred.The current in the neutral wire drops down to zero when the neutral wire is cut off and the phase currents of all three-phase equal to each other since there was no return wire.The currents are equal but the voltages at the phase consumers are different.Especially for residential single-phase consumers,the voltage at the consumers of the phase varies differently for three phase systems when the neutral wire was disconnected at consumer side and even the voltage at the consumers one or two of those three phases becomes over nominal voltage or reaches nearly line voltage.In this case,the electronic appliances in that phase will be fed by high voltage than the rated value and they can be broken down.In the power system of UB(Ulaanbaatar)city,there are some occasional such kind of failures every year.Obviously,many electronic appliances were broken down due to high voltage and the electricity utility companies respond for service charge of damaged parts. 展开更多
关键词 neutral connection and neutral wire phase and line voltage single-phase residential consumer transformer neutral cut off asymmetric load current protective earth
下载PDF
Transforming growth factor -β neutralizing antibodies inhibit subretinal fibrosis in a mouse model 被引量:8
2
作者 Han Zhang Zhe-Li Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期307-311,共5页
AIM:To determine the involvement of the transforming growth factor(TGF)-β with the development of experimental subretinal fibrosis in a mouse model.· METHODS:Subretinal fibrosis was induced by subretinal injecti... AIM:To determine the involvement of the transforming growth factor(TGF)-β with the development of experimental subretinal fibrosis in a mouse model.· METHODS:Subretinal fibrosis was induced by subretinal injection of macrophage-rich peritoneal exudate cells(PECs) and the local expression of TGF-β isoforms was assessed by quantitative real-time reverse transcription-polymerase chain reaction(RT-PCR) and enzyme-linked immunosorbent assay(ELISA) at various time points.In addition,we investigated the effect of TFG-β-neutralizing antibodies(TGF-β NAb) on subretinal fibrosis development.· RESULTS:TGF-β1 and TGF-β2 mRNA level was significantly elevated at day 2 after subretinal fibrosis induction and increased further to 5 and 6.5-fold respectively at day 5,reaching the peak.TGF-β3 mRNA was not detected in the present study.The result of ELSIA showed that active TGF-β1 and TGF-β2 levels were upregulated to 10-fold approximately,while total TGF-β1 and TGF-β2 levels were even upregulated more than 10-fold and more than 20-fold respectively in subretinal fibrosis mice in comparison with na?觙ve mice at day 5.TGF-β NAb resulted in a reduced subretinal fibrosis areas by 65% compared to animals from control group at day 7.· CONCLUSION:Our results indicate that TGF-β signaling may contribute to the pathogenesis of subretinal fibrogenesis and TGF-β inhibition may provide an effective,novel treatment of advanced and late-stage neovascular age-related macular degeneration.· 展开更多
关键词 transforming growth factor-β subretinal fibrosis transforming growth factor-β neutralizing antibody
下载PDF
Oscillation criteria for second order neutral dynamic equations of Emden-Fowler type with positive and negative coefficients on time scales 被引量:9
3
作者 DENG XunHuan WANG QiRu ZHOU Zhan 《Science China Mathematics》 SCIE CSCD 2017年第1期113-132,共20页
We investigate oscillation of certain second order neutral dynamic equations of Emden-Fowler type with positive and negative coefficients. We use some different techniques and apply Riccati transformation to establish... We investigate oscillation of certain second order neutral dynamic equations of Emden-Fowler type with positive and negative coefficients. We use some different techniques and apply Riccati transformation to establish new oscillatory criteria which include two necessary and sufficient conditions. Moreover, we point out that how the power γ plays its role. Some interesting examples are given to illustrate the versatility of our results. 展开更多
关键词 neutral dynamic equations oscillation positive and negative coefficients Riccati transformation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部