In the existing small-signal stability constrained op-timal power flow(SSSC-OPF)algorithms,only the rightmost ei-genvalue or eigenvalues that do not satisfy a given threshold,e.g.,damping ratio threshold and real-part...In the existing small-signal stability constrained op-timal power flow(SSSC-OPF)algorithms,only the rightmost ei-genvalue or eigenvalues that do not satisfy a given threshold,e.g.,damping ratio threshold and real-part threshold of eigen-value,are considered in the small-signal stability constraints.The effect of steady-state,i.e.,operating point,changes on eigen-values is not fully taken into account.In this paper,the small-signal stability constraint that can fully reflect the eigenvalue change and system dynamic performance requirement is formed by analyzing the eigenvalue distribution on the complex plane.The small-signal stability constraint is embedded into the standard optimal power flow model for generation reschedul-ing.The simultaneous solution formula of the SSSC-OPF is es-tablished and solved by the quasi-Newton approach,while pen-alty factors corresponding to the eigenvalue constraints are de-termined by the stabilization degree of constrained eigenvalues.To improve the computation speed,a hybrid algorithm for ei-genvalue computation in the optimization process is proposed,which includes variable selection for eigenvalue estimation and strategy selection for eigenvalue computation.The effectiveness of the proposed algorithm is tested and validated on the New England 10-machine 39-bus system and a modified practical 68-machine 2395-bus system.展开更多
Voltage stability has become an important issue in planning and operation of many power systems. This work includes multi-objective evolutionary algorithm techniques such as Genetic Algorithm (GA) and Non-dominated So...Voltage stability has become an important issue in planning and operation of many power systems. This work includes multi-objective evolutionary algorithm techniques such as Genetic Algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) approach for solving Voltage Stability Constrained-Optimal Power Flow (VSC-OPF). Base case generator power output, voltage magnitude of generator buses are taken as the control variables and maximum L-index of load buses is used to specify the voltage stability level of the system. Multi-Objective OPF, formulated as a multi-objective mixed integer nonlinear optimization problem, minimizes fuel cost and minimizes emission of gases, as well as improvement of voltage profile in the system. NSGA-II based OPF-case 1-Two objective-Min Fuel cost and Voltage stability index;case 2-Three objective-Min Fuel cost, Min Emission cost and Voltage stability index. The above method is tested on standard IEEE 30-bus test system and simulation results are done for base case and the two severe contingency cases and also on loaded conditions.展开更多
The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Pro...The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Producers (IPP) with linear ramp model and transient stability constraints of the power producers. Generally the power producers must respond quickly to the changes in load and wheeling transactions. Moreover, it becomes necessary for the power producers to reschedule their power generation beyond their power limits to meet vulnerable situations like credible contingency and increase in load conditions. During this process, the ramping cost is incurred if they violate their permissible elastic limits. In this paper, optimal production costs of the power producers are computed with stepwise and piecewise linear ramp rate limits. Transient stability limits of the power producers are also considered as addi-tional rotor angle inequality constraints while solving the Optimal Power Flow (OPF) problem. The proposed algo-rithm is demonstrated on practical 10 bus and 26 bus systems and the results are compared with other optimization methods.展开更多
The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronizat...The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.展开更多
This paper is a further study of two papers [1] and [2], which were related to Ill-Conditioned Load Flow Problems and were published by IEEE Trans. PAS. The authors of this paper have some different opinions, for exam...This paper is a further study of two papers [1] and [2], which were related to Ill-Conditioned Load Flow Problems and were published by IEEE Trans. PAS. The authors of this paper have some different opinions, for example, the 11-bus system is not an ill-conditioned system. In addition, a new approach to solve Load Flow Problems, E-ψtc, is introduced. It is an explicit method;solving linear equations is not needed. It can handle very tough and very large systems. The advantage of this method has been fully proved by two examples. The authors give this new method a detailed description of how to use it to solve Load Flow Problems and successfully apply it to the 43-bus and the 11-bus systems. The authors also propose a strategy to test the reliability, and by solving gradient equations, this new method can answer if the solution exists or not.展开更多
Electricity network is a very complex entity that comprises several components like generators, transmission lines, loads among others. As technologies continue to evolve, the complexity of the electricity network has...Electricity network is a very complex entity that comprises several components like generators, transmission lines, loads among others. As technologies continue to evolve, the complexity of the electricity network has also increased as more devices are being connected to the network. To understand the physical laws governing the operation of the network, techniques such as optimal power flow (OPF), Economic dispatch (ED) and Security constrained optimal power flow (SCOPF) were developed. These techniques have been used extensively in network operation, planning and so on. However, an in-depth presentation showcasing the merits and demerits of these techniques is still lacking in the literature. Hence, this paper intends to fill this gap. In this paper, Economic dispatch, optimal power flow and security-constrained optimal power flow are applied to a 3-bus test system using a linear programming approach. The results of the ED, OPF and SC-OPF are compared and presented.展开更多
To deal with the high dimensionality and computational density of the Optimal Power Flow model with Transient Stability Constraints(OTS),a credible criterion to determine transient stability is proposed based on swing...To deal with the high dimensionality and computational density of the Optimal Power Flow model with Transient Stability Constraints(OTS),a credible criterion to determine transient stability is proposed based on swing curves of generator rotor and the characteristics of transient stability.With this method,the swing curves of all generator rotors will be independent one another.Therefore,when a parallel computing approach based on the MATLAB parallel toolbox is used to handle multi-contingency cases,the calculation speed is improved significantly.Finally,numerical simulations on three test systems including the NE-39 system,the IEEE 300-bus system,and 703-bus systems,show the effectiveness of the proposed method in reducing the computing time of OTS calculation.展开更多
In practical power systems,operators generally keep interface flowing under the transient stability constrained with interface real power flow limits(TS-IRPFL)to guarantee transient stability of the system.Many method...In practical power systems,operators generally keep interface flowing under the transient stability constrained with interface real power flow limits(TS-IRPFL)to guarantee transient stability of the system.Many methods of computing TS-IRPFL have been proposed.However,in practice,the method widely used to determine TS-IRPFL is based on selection and analysis of typical scenarios as well as scenario matching.First,typical scenarios are selected and analyzed to obtain accurate limits,then the scenario to be analyzed is matched with a certain typical scenario,whose limit is adopted as the forecast limit.In this paper,following the steps described above,a pragmatic method to determine TS-IRPFL is proposed.The proposed method utilizes data-driven tools to improve the steps of scenario selection and matching.First of all,we formulate a clear model of power system scenario similarity.Based on the similarity model,we develop a typical scenario selector by clustering and a scenario matcher by nearest neighbor algorithm.The proposed method is pragmatic because it does not change the existing procedure.Moreover,it is much more reasonable than the traditional method.Test results verify the validity of the method.展开更多
This paper proposes a voltage stability constrained optimal power flow(VSC-OPF)for an unbalanced distribution system with distributed generators(DGs)based on semidefinite programming(SDP).The AC optimal power flow(ACO...This paper proposes a voltage stability constrained optimal power flow(VSC-OPF)for an unbalanced distribution system with distributed generators(DGs)based on semidefinite programming(SDP).The AC optimal power flow(ACOPF)for unbalanced distribution systems is formulated as a chordal relaxation-based SDP model.The minimal singular value(MSV)of the power flow Jacobian matrix is adopted to indicate the voltage stability margin.The Jacobian matrix can be explicitly expressed by ACOPF state variables.The nonlinear constraint on the Jacobian MSV is then replaced with its maximal convex subset using linear matrix inequality(LMI),which can be incorporated in the SDP-based ACOPF formulation.A penalty technique is leveraged to improve the exactness of the SDP relaxation.Case studies performed on several IEEE test systems validate the effectiveness of the proposed method.展开更多
Calculation of static voltage stability margin(SVSM)of AC/DC power systems with lots of renewable energy sources(RESs)integration requires consideration of uncertain load growth and renewable energy generation output....Calculation of static voltage stability margin(SVSM)of AC/DC power systems with lots of renewable energy sources(RESs)integration requires consideration of uncertain load growth and renewable energy generation output.This paper presents a bi-level optimal power flow(BLOPF)model to identify the worst-case SVSM of an AC/DC power system with line commutation converter-based HVDC and multi-terminal voltage sourced converter-based HVDC transmission lines.Constraints of uncertain load growth’s hypercone model and control mode switching of DC converter stations are considered in the BLOPF model.Moreover,uncertain RES output fluctuations are described as intervals,and two three-level optimal power flow(TLOPF)models are established to identify interval bounds of the system worst-case SVSM.The two TLOPF models are both transformed into max–min bi-level optimization models according to independent characteristics of different uncertain variables.Then,transforming the inner level model into its dual form,max–min BLOPF models are simplified to single-level optimization models for direct solution.Calculation results on the modified IEEE-39 bus AC/DC case and an actual large-scale AC/DC case in China indicate correctness and efficiency of the proposed identification method.展开更多
基金supported by the National Natural Science Foundation of China(No.62203395)the Postdoctoral Research Project of Henan Province(No.202101011)the Key R&D and Promotion Project of Henan Province(No.222102220041).
文摘In the existing small-signal stability constrained op-timal power flow(SSSC-OPF)algorithms,only the rightmost ei-genvalue or eigenvalues that do not satisfy a given threshold,e.g.,damping ratio threshold and real-part threshold of eigen-value,are considered in the small-signal stability constraints.The effect of steady-state,i.e.,operating point,changes on eigen-values is not fully taken into account.In this paper,the small-signal stability constraint that can fully reflect the eigenvalue change and system dynamic performance requirement is formed by analyzing the eigenvalue distribution on the complex plane.The small-signal stability constraint is embedded into the standard optimal power flow model for generation reschedul-ing.The simultaneous solution formula of the SSSC-OPF is es-tablished and solved by the quasi-Newton approach,while pen-alty factors corresponding to the eigenvalue constraints are de-termined by the stabilization degree of constrained eigenvalues.To improve the computation speed,a hybrid algorithm for ei-genvalue computation in the optimization process is proposed,which includes variable selection for eigenvalue estimation and strategy selection for eigenvalue computation.The effectiveness of the proposed algorithm is tested and validated on the New England 10-machine 39-bus system and a modified practical 68-machine 2395-bus system.
文摘Voltage stability has become an important issue in planning and operation of many power systems. This work includes multi-objective evolutionary algorithm techniques such as Genetic Algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) approach for solving Voltage Stability Constrained-Optimal Power Flow (VSC-OPF). Base case generator power output, voltage magnitude of generator buses are taken as the control variables and maximum L-index of load buses is used to specify the voltage stability level of the system. Multi-Objective OPF, formulated as a multi-objective mixed integer nonlinear optimization problem, minimizes fuel cost and minimizes emission of gases, as well as improvement of voltage profile in the system. NSGA-II based OPF-case 1-Two objective-Min Fuel cost and Voltage stability index;case 2-Three objective-Min Fuel cost, Min Emission cost and Voltage stability index. The above method is tested on standard IEEE 30-bus test system and simulation results are done for base case and the two severe contingency cases and also on loaded conditions.
文摘The application of a novel Particle Swarm Optimization (PSO) method called Fitness Distance Ratio PSO (FDR PSO) algorithm is described in this paper to determine the optimal power dispatch of the Independent Power Producers (IPP) with linear ramp model and transient stability constraints of the power producers. Generally the power producers must respond quickly to the changes in load and wheeling transactions. Moreover, it becomes necessary for the power producers to reschedule their power generation beyond their power limits to meet vulnerable situations like credible contingency and increase in load conditions. During this process, the ramping cost is incurred if they violate their permissible elastic limits. In this paper, optimal production costs of the power producers are computed with stepwise and piecewise linear ramp rate limits. Transient stability limits of the power producers are also considered as addi-tional rotor angle inequality constraints while solving the Optimal Power Flow (OPF) problem. The proposed algo-rithm is demonstrated on practical 10 bus and 26 bus systems and the results are compared with other optimization methods.
基金The authors extend their appreciation to the Deanship of Scientific Research at Jouf University for funding this work through research Grant No.(DSR-2021-02-0113).
文摘The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.
文摘This paper is a further study of two papers [1] and [2], which were related to Ill-Conditioned Load Flow Problems and were published by IEEE Trans. PAS. The authors of this paper have some different opinions, for example, the 11-bus system is not an ill-conditioned system. In addition, a new approach to solve Load Flow Problems, E-ψtc, is introduced. It is an explicit method;solving linear equations is not needed. It can handle very tough and very large systems. The advantage of this method has been fully proved by two examples. The authors give this new method a detailed description of how to use it to solve Load Flow Problems and successfully apply it to the 43-bus and the 11-bus systems. The authors also propose a strategy to test the reliability, and by solving gradient equations, this new method can answer if the solution exists or not.
文摘Electricity network is a very complex entity that comprises several components like generators, transmission lines, loads among others. As technologies continue to evolve, the complexity of the electricity network has also increased as more devices are being connected to the network. To understand the physical laws governing the operation of the network, techniques such as optimal power flow (OPF), Economic dispatch (ED) and Security constrained optimal power flow (SCOPF) were developed. These techniques have been used extensively in network operation, planning and so on. However, an in-depth presentation showcasing the merits and demerits of these techniques is still lacking in the literature. Hence, this paper intends to fill this gap. In this paper, Economic dispatch, optimal power flow and security-constrained optimal power flow are applied to a 3-bus test system using a linear programming approach. The results of the ED, OPF and SC-OPF are compared and presented.
基金This work was supported by the National Natural Science Foundation of China(Grant No.51577085).
文摘To deal with the high dimensionality and computational density of the Optimal Power Flow model with Transient Stability Constraints(OTS),a credible criterion to determine transient stability is proposed based on swing curves of generator rotor and the characteristics of transient stability.With this method,the swing curves of all generator rotors will be independent one another.Therefore,when a parallel computing approach based on the MATLAB parallel toolbox is used to handle multi-contingency cases,the calculation speed is improved significantly.Finally,numerical simulations on three test systems including the NE-39 system,the IEEE 300-bus system,and 703-bus systems,show the effectiveness of the proposed method in reducing the computing time of OTS calculation.
基金This work was supported by National Key R&D Program of China(2018YFB0904500)and State Grid Corporation of China。
文摘In practical power systems,operators generally keep interface flowing under the transient stability constrained with interface real power flow limits(TS-IRPFL)to guarantee transient stability of the system.Many methods of computing TS-IRPFL have been proposed.However,in practice,the method widely used to determine TS-IRPFL is based on selection and analysis of typical scenarios as well as scenario matching.First,typical scenarios are selected and analyzed to obtain accurate limits,then the scenario to be analyzed is matched with a certain typical scenario,whose limit is adopted as the forecast limit.In this paper,following the steps described above,a pragmatic method to determine TS-IRPFL is proposed.The proposed method utilizes data-driven tools to improve the steps of scenario selection and matching.First of all,we formulate a clear model of power system scenario similarity.Based on the similarity model,we develop a typical scenario selector by clustering and a scenario matcher by nearest neighbor algorithm.The proposed method is pragmatic because it does not change the existing procedure.Moreover,it is much more reasonable than the traditional method.Test results verify the validity of the method.
基金funded by State Grid Corporation of China(SGCC)under project“Hybrid Energy Storage Management Platform for Integrated Energy System”(No.SGGR0000DLJS1800932).
文摘This paper proposes a voltage stability constrained optimal power flow(VSC-OPF)for an unbalanced distribution system with distributed generators(DGs)based on semidefinite programming(SDP).The AC optimal power flow(ACOPF)for unbalanced distribution systems is formulated as a chordal relaxation-based SDP model.The minimal singular value(MSV)of the power flow Jacobian matrix is adopted to indicate the voltage stability margin.The Jacobian matrix can be explicitly expressed by ACOPF state variables.The nonlinear constraint on the Jacobian MSV is then replaced with its maximal convex subset using linear matrix inequality(LMI),which can be incorporated in the SDP-based ACOPF formulation.A penalty technique is leveraged to improve the exactness of the SDP relaxation.Case studies performed on several IEEE test systems validate the effectiveness of the proposed method.
基金supported by the National Natural Science Foundation of China(Grant No.51977080)the Natural Science Foundation of Guangdong Province(Grant No.2022A1515010332)supported by the U.S.National Science Foundation(Grant#2124849).
文摘Calculation of static voltage stability margin(SVSM)of AC/DC power systems with lots of renewable energy sources(RESs)integration requires consideration of uncertain load growth and renewable energy generation output.This paper presents a bi-level optimal power flow(BLOPF)model to identify the worst-case SVSM of an AC/DC power system with line commutation converter-based HVDC and multi-terminal voltage sourced converter-based HVDC transmission lines.Constraints of uncertain load growth’s hypercone model and control mode switching of DC converter stations are considered in the BLOPF model.Moreover,uncertain RES output fluctuations are described as intervals,and two three-level optimal power flow(TLOPF)models are established to identify interval bounds of the system worst-case SVSM.The two TLOPF models are both transformed into max–min bi-level optimization models according to independent characteristics of different uncertain variables.Then,transforming the inner level model into its dual form,max–min BLOPF models are simplified to single-level optimization models for direct solution.Calculation results on the modified IEEE-39 bus AC/DC case and an actual large-scale AC/DC case in China indicate correctness and efficiency of the proposed identification method.