期刊文献+
共找到4,630篇文章
< 1 2 232 >
每页显示 20 50 100
The Static Stability Region of an Integrated Electricity-Gas System Considering Voltage and Gas Pressure
1
作者 Yunfei Mu Zhibin Liu +5 位作者 Xiangwei Guo Hongjie Jia Kai Hou Xiaodan Yu Bofeng Luo Hairun Li 《Engineering》 SCIE EI CAS CSCD 2024年第5期132-145,共14页
In an integrated electricity-gas system(IEGS),load fluctuations affect not only the voltage in the power system but also the gas pressure in the natural gas system.The static voltage stability region(SVSR)method is a ... In an integrated electricity-gas system(IEGS),load fluctuations affect not only the voltage in the power system but also the gas pressure in the natural gas system.The static voltage stability region(SVSR)method is a tool for analyzing the overall static voltage stability in a power system.However,in an IEGS,the SVSR boundary may be overly optimistic because the gas pressure may collapse before the voltage collapses.Thus,the SVSR method cannot be directly applied to an IEGS.In this paper,the concept of the SVSR is extended to the IEGS-static stability region(SSR)while considering voltage and gas pressure.First,criteria for static gas pressure stability in a natural gas system are proposed,based on the static voltage stability criteria in a power system.Then,the IEGS-SSR is defined as a set of active power injections that satisfies multi-energy flow(MEF)equations and static voltage and gas pressure stability constraints in the active power injection space of natural gas-fired generator units(NGUs).To determine the IEGSSSR,a continuation MEF(CMEF)method is employed to trace the boundary point in one specific NGU scheduling direction.A multidimensional hyperplane sampling method is also proposed to sample the NGU scheduling directions evenly.The obtained boundary points are further used to form the IEGSSSR in three-dimensional(3D)space via a Delaunay triangulation hypersurface fitting method.Finally,the numerical results of typical case studies are presented to demonstrate that the proposed method can effectively form the IEGS-SSR,providing a tool for IEGS online monitoring and dispatching. 展开更多
关键词 Integrated electricity-gas system static stability region Continuation multi-energy flow Multidimensional hyperplane sampling
下载PDF
Review of the Configuration and Transient Stability of Large-scale Renewable Energy Generation through Hybrid DC Transmission
2
作者 Xinshou Tian Yongning Chi +1 位作者 Longxue Li Hongzhi Liu 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期115-126,共12页
Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection ... Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection of LCC converter stations and MMC converter stations,and the other is the series connection of LCC and MMC converter stations within a single station.The hybrid DC transmission system faces broad application prospects and development potential in large-scale clean energy integration across regions and the construction of a new power system dominated by new energy sources in China.This paper first analyzes the system forms and topological characteristics of hybrid DC transmission,introducing the forms and topological characteristics of converter-level hybrid DC transmission systems and system-level hybrid DC transmission systems.Next,it analyzes the operating characteristics of LCC and MMC inverter-level hybrid DC transmission systems,provides insights into the transient stability of hybrid DC transmission systems,and typical fault ride-through control strategies.Finally,it summarizes the networking characteristics of the LCC-MMC series within the converter station hybrid DC transmission system,studies the transient characteristics and fault ridethrough control strategies under different fault types for the LCC-MMC series in the receiving-end converter station,and investigates the transient characteristics and fault ride-through control strategies under different fault types for the LCC-MMC series in the sending-end converter station. 展开更多
关键词 Hybrid DC transmission transient stability CONFIGURATION Control system
下载PDF
Migratable Power System Transient Stability AssessmentMethod Based on Improved XGBoost
3
作者 Ying Qu Jinhao Wang +4 位作者 Xueting Cheng Jie Hao Weiru Wang Zhewen Niu Yuxiang Wu 《Energy Engineering》 EI 2024年第7期1847-1863,共17页
The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited b... The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited by the quality of the data and has weak transferability.Based on this,this paper proposes a method for TSA of power systems based on an improved extreme gradient boosting(XGBoost)model.Firstly,the gradient detection method is employed to remove noise interference while maintaining the original time series trend.On this basis,a focal loss function is introduced to guide the training of theXGBoostmodel,enhancing the deep exploration of minority class samples to improve the accuracy of the model evaluation.Furthermore,to improve the generalization ability of the evaluation model,a transfer learning method based on model parameters and sample augmentation is proposed.The simulation analysis on the IEEE 39-bus system demonstrates that the proposed method,compared to the traditional machine learning-based transient stability assessment approach,achieves an average improvement of 2.16%in evaluation accuracy.Specifically,under scenarios involving changes in topology structure and operating conditions,the accuracy is enhanced by 3.65%and 3.11%,respectively.Moreover,the model updating efficiency is enhanced by 14–15 times,indicating the model’s transferable and adaptive capabilities across multiple scenarios. 展开更多
关键词 transient stability assessment DATA-DRIVEN segmented focusing approximation PORTABILITY
下载PDF
Optimal Allocation of STATCOM to Enhance Transient Stability Using Imperialist Competitive Algorithm
4
作者 Ayman Amer Firas MMakahleh +4 位作者 Jafar Ababneh Hani Attar Ahmed Amin Ahmed Solyman Mehrdad Ahmadi Kamarposhti Phatiphat Thounthong 《Intelligent Automation & Soft Computing》 SCIE 2023年第6期3425-3446,共22页
With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possi... With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices. 展开更多
关键词 STATCOM FACTS OPTIMIZATION transient stability imperialist competitive algorithm
下载PDF
NOVEL FORMULATION OF STATIC STABILITY FOR A WALKING QUADRUPED ROBOT 被引量:4
5
作者 Chen XuedongSchool of Mechanical Scienceand Engineering,Huazhong University of Scienceand Technology,Wuhan 430074, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第2期120-122,共3页
By defining the static stable area for foot placement, a new approach toanalysis of quadruped robot stability is presented. Unlike conventionally, the method avoids solvingcomplicated direct kinematics of quadruped ro... By defining the static stable area for foot placement, a new approach toanalysis of quadruped robot stability is presented. Unlike conventionally, the method avoids solvingcomplicated direct kinematics of quadruped robot and shows the information on the robot stabilityand the selection of swing leg. Especially, the proposed algorithm can be used as real-timeoperation for on-line gait generation and control for quadruped robots. The effectiveness of theproposed approach is shown through a practical crawling experiment of the quadruped robotTITAN-VIII. 展开更多
关键词 quadruped robot static stability gait generation
下载PDF
Global static stability and its relation to gravity waves in the middle atmosphere 被引量:5
6
作者 Xiao Liu JiYao Xu Jia Yue 《Earth and Planetary Physics》 CSCD 2020年第5期504-512,共9页
The global atmospheric static stability(N2)in the middle atmosphere and its relation to gravity waves(GWs)were investigated by using the temperature profiles measured by the Sounding of the Atmosphere using Broadband ... The global atmospheric static stability(N2)in the middle atmosphere and its relation to gravity waves(GWs)were investigated by using the temperature profiles measured by the Sounding of the Atmosphere using Broadband Emission Radiometry(SABER)instrument from 2002 to 2018.At low latitudes,a layer with enhanced N2 occurs at an altitude of^20 km and exhibits annual oscillations caused by tropopause inversion layers.Above an altitude of^70 km,enhanced N2 exhibits semiannual oscillations at low latitudes caused by the mesosphere inversion layers and annual oscillations at high latitudes resulting from the downward shift of the summer mesopause.The correlation coefficients between N2 and GW amplitudes can be larger than 0.8 at latitudes poleward of^40°N/S.This observation provides factual evidence that a large N2 supports large-amplitude GWs and indicates that N2 plays a dominant role in maintaining GWs at least at high latitudes of the middle atmosphere.This evidence also partially explains the previous results regarding the phase changes of annual oscillations of GWs at high latitudes. 展开更多
关键词 atmospheric static stability gravity waves annual oscillation semiannual oscillation MESOPAUSE
下载PDF
A Nonlinear Coordinated Approach to Enhance the Transient Stability of Wind Energy-Based Power Systems 被引量:4
7
作者 Mohammad Javad Morshed 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2020年第4期1087-1097,共11页
This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based... This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions. 展开更多
关键词 Doubly fed induction generator(DFIG) excitation controller multi-machine power system synchronous generator(SG) transient stability zero dynamics
下载PDF
Contribution to the Optimization of the Transient Stability of an Electric Power Transmission Network Using a Universal Power Flow Compensator Controlled by a Three-Stage Inverter 被引量:2
8
作者 Koko Koko Joseph Nneme Nneme Léandre Ndjakomo Essiane Salomé 《World Journal of Engineering and Technology》 2020年第4期675-688,共14页
The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of... The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%. 展开更多
关键词 FACTS UPFC Three-Stage Inverter PI Power Transit transient stability
下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics 被引量:2
9
作者 Masaki Yagami Takahiko Hasegawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2012年第12期762-768,共7页
As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the... As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software. 展开更多
关键词 High-penetration photovoltaics low-voltage ride-through (LVRT) synchronous generator transient stability.
下载PDF
Transient Stability Analysis of Power System with Photovoltaic Systems Installed 被引量:1
10
作者 Masaki Yagami Seiichiro Ishikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Energy and Power Engineering》 2015年第10期896-904,共9页
The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generat... The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence, the power system transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the potential impact of significant PV penetration on the transient stability is assessed by a numerical simulation using PSCAD/EMTDC. 展开更多
关键词 PHOTOVOLTAIC LVRT (low-voltage ride-through) synchronous generator infinite bus transient stability.
下载PDF
Transient Stability Analysis Using Transmission Line Measurement
11
作者 蔡国伟 程浩忠 +1 位作者 陈家荣 王承民 《Journal of Shanghai Jiaotong university(Science)》 EI 2004年第2期29-35,共7页
The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cut... The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cutsets and power system according to features of transient energy in the lines were given, which not only provide a reliable and accurate assessment of the transient stability of power system, but also can be used to assess the effect of lines and cutsets on the transient stability and identify the weak transmission segment. Examples were presented by simulation on the IEEE-39 buses test system. 展开更多
关键词 power system transient stability local network measurement stability criterion line stability index cutset stability index
下载PDF
An Optimal DF Based Method for Transient Stability Analysis
12
作者 Z.A.Zaki Emad M.Ahmed +1 位作者 Ziad M.Ali Imran Khan 《Computers, Materials & Continua》 SCIE EI 2022年第2期3449-3471,共23页
The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronizat... The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them. 展开更多
关键词 transient stability analysis power system cascade structure optimal power flow
下载PDF
Transient Stability Analysis of Synchronous Generator in Power System with Renewable Power Sources Installed
13
作者 Masaki Yagami Yoshihiro Ichinohe +2 位作者 Yohichiro Kojima Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2016年第8期400-407,共8页
The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magn... The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated. 展开更多
关键词 Fault ride-through variable speed wind generator PHOTOVOLTAIC synchronous generator transient stability.
下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)
14
作者 Masaki Yagami Seiichiro lshikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2015年第7期401-406,共6页
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ... In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated. 展开更多
关键词 High-penetration photovoltaics LVRT (low-voltage ride-through) synchronous generator transient stability
下载PDF
Impact of Wind Farms of DFIG Type on Power System Transient Stability 被引量:2
15
作者 Libao Shi Shiqiang Dai +2 位作者 Liangzhong Yao Yixin Ni Masoud Bazargan 《Journal of Electromagnetic Analysis and Applications》 2010年第8期475-481,共7页
The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/... The impact of large-scale grid-connected wind farms of Doubly-fed Induction Generator (DFIG) type on power system transient stability is elaborately discussed in this paper. In accordance with an equivalent generator/converter model, the comprehensive numerical simulations with multiple wind farms of DFIG type involved are carried out to reveal the impact of wind farm on dynamic behavior of existing interconnected power system. Different load models involving nonlinear load model and induction motor model are considered during simulations. Finally, some preliminary conclusions are summarized and discussed. 展开更多
关键词 transient stability DFIG Multiple WIND Farms WIND FARM Integration LOAD Model
下载PDF
Transient Stability Study of Power System with Large-Scale Wind Farm Integration 被引量:1
16
作者 Run Lin Ruiye Liu 《Energy and Power Engineering》 2017年第4期552-561,共10页
Large-scale wind power integration has become the current development trend of the power system. Large-scale wind power integration can change the original structure and characteristics of the system. Thus, it’s nece... Large-scale wind power integration has become the current development trend of the power system. Large-scale wind power integration can change the original structure and characteristics of the system. Thus, it’s necessary to analyse the transient stability of power system which contains wind power, and to study the controlling strategy for improving the transient stability of power system. Based on EEAC, this paper studies the transient stability of the power system which contains wind power system theoretically, proposes the calculation method for accelerating area, decelerating area and margin, and illustrates the impact of wind power integration on the transient stability with power angle curve. Furthermore, this paper studies the modeling and simulation, and the experimental results prove the correctness of the theories. 展开更多
关键词 transient stability DFIG EEAC Wind FARM INTEGRATION
下载PDF
Topologic Reconstruction of Power System to Enhance Transient Stability
17
作者 李卫东 于继来 +1 位作者 柳焯 宋家骅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第4期66-71,共6页
Topologic reconstruction of network is proposed to enhance transient stability. At last, because screening indices are based on Z- matrix, the proposed reconstrution is simple and practical. The results of two test sy... Topologic reconstruction of network is proposed to enhance transient stability. At last, because screening indices are based on Z- matrix, the proposed reconstrution is simple and practical. The results of two test systems support the propeal and the validity of the proposal is verified by the implementation of a realistic system. 展开更多
关键词 RECONSTRUCTION TOPOLOGY transient stability
下载PDF
Transient Stability Simulation of 33 kV Power Grid
18
作者 Nader Barsoum Nadira Zulkeffley Myjessie Songkin 《Energy and Power Engineering》 2018年第6期301-318,共18页
An example of Sandakan power grid problem is presented in this paper. Sandakan is a suburb in east coast of Sabah state of Malaysia. Stability problem occurs due to the increase in load demand, lack of generation sour... An example of Sandakan power grid problem is presented in this paper. Sandakan is a suburb in east coast of Sabah state of Malaysia. Stability problem occurs due to the increase in load demand, lack of generation sources and inadequate supply. The tripping disturbances occur frequently in the network which is contributing to voltage instability. In this paper dynamics stability of 33 kV power grid as related to Sandakan network is analyzed and simulated. The analysis is completed by modelling the network data in Power System Simulation for Engineering (PSS/E) software and simulate the transient stability of generator, exciter and governor during a three phase fault occurs on a far and close distance from a bus, and determine the critical clearing time as well as swing curve of rotor angle. The output values of electrical power, machine speed, rotor angle and bus voltage are observed. 展开更多
关键词 transient stability PSS/E Load Flow GENERATOR EXCITER GOVERNOR Critical CLEARING Time
下载PDF
Enhancement of Transient Stability of the Nigeria 330 kV Transmission Network Using Fault Current Limiter
19
作者 Ignatius K. Okakwu Emmanuel A. Ogujor 《Journal of Power and Energy Engineering》 2017年第9期92-103,共12页
The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the oc... The dynamic responses of generators when subjected to disturbances in an interconnected power system have become a major challenge to power utility companies due to increasing stress on the power network. Since the occurrence of a disturbance or fault cannot be completely avoided, hence, when it occurs, control measures need to be put in place to limit the fault current, which invariably limit the level of the disturbances. This paper explores the use of Superconductor Fault Current Limiter (SFCL) to improve the transient stability of the Nigeria 330 kV Transmission Network. During a large disturbance, the rotor angle of the generator is enhanced by connecting a Fault Current Limiter (FCL) which reduces the fault current and hence, increases transient stability of the power network. In this study, the most affected generator was taken into consideration in locating the SFCL. The result obtained reveals that the Swing Curve of the generator without FCL increases monotonically which indicates instability, while the Swing Curve of the System with FCL reaches steady state. 展开更多
关键词 transient stability FAULT Current LIMITER NIGERIA 330 KV Power System
下载PDF
Transient Stability Analysis of 33 KV Transmission Network of Egi Community, Nigeria
20
作者 Promise Elechi Christopher Okwuchukwu Ahiakwo Ugochukwu Nureedin Okwu 《Journal of Power and Energy Engineering》 2020年第3期18-35,共18页
Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The s... Transient analysis of 33 KV power transmission line stability of Egi communi-ty is considered in this research work with the aim of reducing the frequency of fault occurrence and voltage collapse in the network. The supply is taken from Egi generating station located at Total Nigeria Limited Gas Plant Obite at voltage level of 33 KV to Egi communities. This work focuses on the transient nature of network stability since transient fault is the most dangerous in elec-trical systems. The swinging of the generator rotor in the event of transient three-phase short circuit fault can be monitored by the circuit breakers and the protective relays which causes mal-functioning of the circuit breakers and pro-tective relays leading to abnormal behavior of the network. Therefore, data obtained from the power station were used as a case study of Independent Power Producer (IPP) in Nigeria. For investigation of the power angle, angular velocity, rotor angle differential changes, and angular velocity differential changes, an electrical transient analyzer tool was employed (ETap version 16.00) for circuit breaker and protective relay time setting of (0.00, 0.05, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40, 0.45, 0.50, 0.55, 0.60). The work used the Trapezoidal numerical technique for data analysis. The graphs were plotted using Matlab R2015a and the results obtained showed that when a symmetrical three-phase short circuit fault occur at one or any of the feeders, the fault must be cleared as quick as possible through the coordination of the circuit breakers and protective relays. For this research work, 17 cycles corresponding to relay time setting of t = 0.34 s were recommended and at each cycle, changes in time with respect to changes in rotor angle, angular velocity, rotor differential and angular velocity differential were calculated on the power network simultaneously. The results demonstrated that the Trapezoidal method is numerically stable, accurate and has faster respond time when compared to Modified Euler and swing equation techniques in event of fault occurrence in network. 展开更多
关键词 Rotor Angle transient stability SWING Equation ANGULAR Speed Differential Changes Trapezoidal RULE Fault CLEARING TIME Critical CLEARING TIME
下载PDF
上一页 1 2 232 下一页 到第