The microwave (MW) transmission method is employed to measure both the plasma density and the plasma decay time in the hollow cathode discharge (HCD) in argon at low pressure. The plasma density in DC-driven or pu...The microwave (MW) transmission method is employed to measure both the plasma density and the plasma decay time in the hollow cathode discharge (HCD) in argon at low pressure. The plasma density in DC-driven or pulsed HCD is on the order of 1012 cm-3, which can block the X-band MW effectively. In the case of pulsed HCD, the MW transmittance shows the same waveform as the pulsed current during the rising edge if the driving frequency is low, but with a longer delay during the falling edge. The MW transmittance reaches a constant low level when the driving frequency is high enough. The plasma decay time in the HCD system is measured to be about 100 μs around a pressure of 120 Pa. The ambipolar diffusion is considered to be the major mechanism in the decay process.展开更多
In this paper, a new carbon fiber based cathode — a low-outgassing-rate carbon fiber array cathode — is investigated experimentally, and the experimental results are compared with those of a polymer velvet cathode. ...In this paper, a new carbon fiber based cathode — a low-outgassing-rate carbon fiber array cathode — is investigated experimentally, and the experimental results are compared with those of a polymer velvet cathode. The carbon fiber array cathode is constructed by inserting bunches of carbon fibers into the cylindrical surface of the cathode. In experiment, the diode base pressure is maintained at 1×10^(-2) Pa–2×10^(-2) Pa, and the diode is driven by a compact pulsed power system which can provide a diode voltage of about 100 kV and pulse duration of about 30 ns at a repetition rate of tens of Hz.Real-time pressure data are measured by a magnetron gauge. Under the similar conditions, the experimental results show that the outgassing rate of the carbon fiber array cathode is an order smaller than that of the velvet cathode and that this carbon fiber array cathode has better shot-to-shot stability than the velvet cathode. Hence, this carbon fiber array cathode is demonstrated to be a promising cathode for the radial diode, which can be used in magnetically insulated transmission line oscillator(MILO) and relativistic magnetron(RM).展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.11005009)
文摘The microwave (MW) transmission method is employed to measure both the plasma density and the plasma decay time in the hollow cathode discharge (HCD) in argon at low pressure. The plasma density in DC-driven or pulsed HCD is on the order of 1012 cm-3, which can block the X-band MW effectively. In the case of pulsed HCD, the MW transmittance shows the same waveform as the pulsed current during the rising edge if the driving frequency is low, but with a longer delay during the falling edge. The MW transmittance reaches a constant low level when the driving frequency is high enough. The plasma decay time in the HCD system is measured to be about 100 μs around a pressure of 120 Pa. The ambipolar diffusion is considered to be the major mechanism in the decay process.
基金Project supported by the National Natural Science Foundation of China(Grant No.61671457)
文摘In this paper, a new carbon fiber based cathode — a low-outgassing-rate carbon fiber array cathode — is investigated experimentally, and the experimental results are compared with those of a polymer velvet cathode. The carbon fiber array cathode is constructed by inserting bunches of carbon fibers into the cylindrical surface of the cathode. In experiment, the diode base pressure is maintained at 1×10^(-2) Pa–2×10^(-2) Pa, and the diode is driven by a compact pulsed power system which can provide a diode voltage of about 100 kV and pulse duration of about 30 ns at a repetition rate of tens of Hz.Real-time pressure data are measured by a magnetron gauge. Under the similar conditions, the experimental results show that the outgassing rate of the carbon fiber array cathode is an order smaller than that of the velvet cathode and that this carbon fiber array cathode has better shot-to-shot stability than the velvet cathode. Hence, this carbon fiber array cathode is demonstrated to be a promising cathode for the radial diode, which can be used in magnetically insulated transmission line oscillator(MILO) and relativistic magnetron(RM).