The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi...The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation.展开更多
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission...This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.展开更多
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce...After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change.展开更多
This paper shows the development of transmission line model, based on lumped element circuit that provides answers directly in the time and phase domain. This model is valid to represent the ideally transposed line, t...This paper shows the development of transmission line model, based on lumped element circuit that provides answers directly in the time and phase domain. This model is valid to represent the ideally transposed line, the phases of each of the small line segments are separated in their modes of propagation and the voltage and current are calculated at the modal domain. However, the conversion phase-mode-phase is inserted in the state equations which describe the currents and voltages along the line of which there is no need to know the user of the model representation of the theory in the line modal domain.展开更多
A new transient analysis method for the transmission line circuits is presented in this paper. Based on the semidiscretization of the telegraph equations, a discretized time domain companion models for the transmissio...A new transient analysis method for the transmission line circuits is presented in this paper. Based on the semidiscretization of the telegraph equations, a discretized time domain companion models for the transmission lines which can be conveniently implemented in a general circuit simulator such as SPICE is derived. The computation required for the model is linear with time, equivalent to the recursive convolution-based method. The formulations for both single and coupled lossy transmission lines are given. Numerical experiments are carried out to demonstrate the validity of the method.展开更多
Analysis approach and formulas for the transmission properties of uniform multicon-ductor interconnecting buses in high-speed integrated circuits are presented in this article. And further, by using a network approach...Analysis approach and formulas for the transmission properties of uniform multicon-ductor interconnecting buses in high-speed integrated circuits are presented in this article. And further, by using a network approach, a tapered bus system can be analyzed as a set of cascaded uniform buses with slightly different strip widths. Obtained results are in good agreement with the experimental data.展开更多
In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based ...In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based on the reactive powers of traveling wave is proposed. With the implementation of S-transform, the initial traveling wave reactive powers are calculated and the change characteristics of reactive power under different fault conditions are studied. The protection criterion is constructed by analyzing the ratio of the reactive powers of the same end on double-circuit transmission lines and the ratio of the reactive powers at both ends on the same line. According to the ratio of reactive power on the same side of the line and both ends of the same line, it is possible to identify whether the faults of the double-circuit line of the same tower occurred in or out of the protection zone. A large number of simulation results show that the protection performance is sensitive and reliable, and quick to respond. The criterion is simple and is basically not affected by fault initial angles, fault types, and transitional resistances.展开更多
The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, w...The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, which is based on right-handed nonlinear transmission lines and consists of a coplanar waveguide transmission line and periodically distributed GaAs planar Schottky varactor diode. The distributed-Schottky transmission-line-type phase shifter at a bias voltage greater than 1.5 V presents a continuous 0°–360° differential phase shift over a frequency range from 0 to 33 GHz. It is demonstrated that the minimum insertion loss is about 0.5 dB and that the return loss is less than-10 dB over the frequency band of 0–33 GHz at a reverse bias voltage less than 4.5 V. These excellent characteristics, such as broad differential phase shift, low insertion loss, and return loss, indicate that the proposed phase shifter can entirely be integrated into a phased array radar circuit.展开更多
This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and t...This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and time-consuming computation. The two main parts of the presented methodology are 1) setting up a three-dimensional (3D) model to calculate the electric field based on combining ca- tenary equations with charge simulation method and 2) calculating the hybrid electric field excited by multi-circuit intersecting TLs using coordinate transformation and superposition technique. Examples of different TLs configurations, including a 220 kV single-circuit hori- zontally configured TLs, a 500 kV single-circuit triangularly configured TLs and a combination of the 220 kV TLs and the 550 kV TLs, are illustrated to verify the validity of this methodology. A more complicatal configurations, including a 500 kV double-circuit TLs and two 220 kV single-circuit horizontally configured TLs, are also calculated. Conclusions were drawn from the simulation: 1) The presented 3D model outperforms 2D models in describing the electric field distribution generated by practical HV TLs with sag and span. 2) Coordinate trans- formation and superposition technique considerably simplify the electric field computation for multi-circuit TLs configurations, which makes it possible to deal with complex engineering problems. 3) The electric field in the area covered by multiple intersecting overhead TLs is distorted and the hybrid electric field strength in some partial region increases so sharply that it might exceed the admissible value. 4) The configuration parameters of the TLs and the spatial configuration of multi-circuit TLs, for instance, the height of TLs, the length of span and the intersection angle of multiple circuits, influence the strength and the distribution of hybrid electric field. The influence regularities sum- marized in this paper can be referred by future TL designs to meet the electromagnetic environmental protection regulations.展开更多
Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode....Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode. Finite element design software SAP2000 was used to model the towers and lines. Non-linear dynamic analysis including the large displacement effects was carried out. Macroscopic aspects of wind coherence along element length and integration time step were investigated. An approach is presented to compare the probabilistic dynamic response due to 7 different stochastically simulated wind fields with the response according to EN-50341. The developed model will be used to study the response recorded on a test line due to the actual wind speed time history recorded. It was found that static load from EN overestimated the strength of conductor cables. The response of coupled system considering towers and cables was found to be different from response of only cables with fixed supports.展开更多
A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed non- linear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) techn...A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed non- linear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) technology. The structure parameters of CRLH NLTLs, e.g. host transmission line, rectangular spiral inductor, and nonlinear capacitor, have a great impact on the second harmonic performance enhancement in terms of second harmonic frequency, output power, and conversion efficiency. It has been experimentally demonstrated that the second harmonic frequency is deter- mined by the anomalous dispersion of CRLH NLTLs and can be significantly improved by effectively adjusting these structure parameters. A good agreement between the measured and simulated second harmonic performances of Ka-band CRLH NLTLs frequency multipliers is successfully achieved, which further validates the design approach of frequency multipliers on CRLH NLTLs and indicates the potentials of CRLH NLTLs in terms of the generation of microwave and millimeter-wave signal source.展开更多
During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper pres...During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper presents analytical methods in order to determine the transmission towers potentials during ground faults,for long and short lines.The author developed a global systematic approach to calculate these voltages,which are dependent of a number of factors.Some of the most important factors are:magnitudes of fault currents,fault location with respect to the line terminals,conductor arrangement on the tower and the location of the faulted phase,the ground resistance of the faulted tower,soil resistivity,number,material and size of ground wires.The effects of these factors on the faulted tower voltages have been also examined for different types of power lines.展开更多
This article describes the design, modelling and characterization of transmission lines for millimetre wave silicon integrated circuits up to 65 GHz. The simulation results of three different EM (electro-magnetic) s...This article describes the design, modelling and characterization of transmission lines for millimetre wave silicon integrated circuits up to 65 GHz. The simulation results of three different EM (electro-magnetic) simulators for a selected hybrid coplanar layout structure are presented. Two different deembedding methods are investigated and compared with respect to sensitivity to typical measurement errors. Finally both methods are applied to the measurement results of the fabricated test structures in a 250 nm BiCMOS technology showing good agreement to EM simulations and predicted sensitivity to measurement errors.展开更多
Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impeda...Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.展开更多
A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlineari...A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.展开更多
In this article, a transmission line is represented by a cascade of n circuits using a single phase. It is analyzed what is the reasonable number of n circuits and the number of blocks composed by parallel resistor an...In this article, a transmission line is represented by a cascade of n circuits using a single phase. It is analyzed what is the reasonable number of n circuits and the number of blocks composed by parallel resistor and inductor in parallel for reduction of numerical oscillations. It is simulated the numerical routine with and without the effectof frequency in the longitudinal parameters. Initially, it is used to state variables and 7t circuits representing the transmission line composing a linear system which is solved by numerical routines based on the trapezoidal rule. The effect of frequency on the line is synthesized by resistors and inductors in parallel and this representation is analyzed in details. It is described as transmission lines and the frequency influence in these lines through the state variables.展开更多
Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a h...Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a higher impedance profile of the internal transmission line would lead to a wider adjustment range for the output current rise time and a narrower adjustment range for the current peak. The number of cavities in series has a positive effect on the output- pulse shaping capability of LTD. Such an improvement in the output-pulse shaping capability can primarily be ascribed to the increment in the axial electric length of LTD. For a triggering time interval longer than the time taken by a pulse to propagate through the length of one cavity, the output parameters of LTD could be improved significantly. The present insulating capability of gas switches and other elements in the LTD cavities may only tolerate a slightly longer deviation in the triggering time interval. It is feasible for the LTD module to reduce the output current rise time, though it is not useful to improve the peak power effectively.展开更多
基金This work was supported by the National Natural Science Foundation of China(Nos.62172242,51901152)Industry University Cooperation Education Program of the Ministry of Education(No.2020021680113)Shanxi Scholarship Council of China.
文摘The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation.
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
文摘This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.
基金supported by National Natural Science Fund of China (Grant No. 41401088)State Grid Qinghai Electric Power Research Institute (SGQHDKYOSBJS201600077, SGQHDKYOSBJS 1700068)Funds of State Key Laboratory of Frozen Soil Engineering (Nos. SKLFSE-ZY-17, SKLFSEZT-32)
文摘After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change.
文摘This paper shows the development of transmission line model, based on lumped element circuit that provides answers directly in the time and phase domain. This model is valid to represent the ideally transposed line, the phases of each of the small line segments are separated in their modes of propagation and the voltage and current are calculated at the modal domain. However, the conversion phase-mode-phase is inserted in the state equations which describe the currents and voltages along the line of which there is no need to know the user of the model representation of the theory in the line modal domain.
文摘A new transient analysis method for the transmission line circuits is presented in this paper. Based on the semidiscretization of the telegraph equations, a discretized time domain companion models for the transmission lines which can be conveniently implemented in a general circuit simulator such as SPICE is derived. The computation required for the model is linear with time, equivalent to the recursive convolution-based method. The formulations for both single and coupled lossy transmission lines are given. Numerical experiments are carried out to demonstrate the validity of the method.
文摘Analysis approach and formulas for the transmission properties of uniform multicon-ductor interconnecting buses in high-speed integrated circuits are presented in this article. And further, by using a network approach, a tapered bus system can be analyzed as a set of cascaded uniform buses with slightly different strip widths. Obtained results are in good agreement with the experimental data.
文摘In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based on the reactive powers of traveling wave is proposed. With the implementation of S-transform, the initial traveling wave reactive powers are calculated and the change characteristics of reactive power under different fault conditions are studied. The protection criterion is constructed by analyzing the ratio of the reactive powers of the same end on double-circuit transmission lines and the ratio of the reactive powers at both ends on the same line. According to the ratio of reactive power on the same side of the line and both ends of the same line, it is possible to identify whether the faults of the double-circuit line of the same tower occurred in or out of the protection zone. A large number of simulation results show that the protection performance is sensitive and reliable, and quick to respond. The criterion is simple and is basically not affected by fault initial angles, fault types, and transitional resistances.
基金Project supported by the Fundamental Research Funds for Central Universities,China(Grant No.XDJK2013B004)the Research Fund for the Doctoral Program of Southwest University,China(Grant No.SWU111030)the State Key Laboratory for Millimeter Waves of Southeast University,China(Grant No.K201312)
文摘The epitaxial material, device structure, and corresponding equivalent large signal circuit model of GaAs planar Schottky varactor diode are successfully developed to design and fabricate a monolithic phase shifter, which is based on right-handed nonlinear transmission lines and consists of a coplanar waveguide transmission line and periodically distributed GaAs planar Schottky varactor diode. The distributed-Schottky transmission-line-type phase shifter at a bias voltage greater than 1.5 V presents a continuous 0°–360° differential phase shift over a frequency range from 0 to 33 GHz. It is demonstrated that the minimum insertion loss is about 0.5 dB and that the return loss is less than-10 dB over the frequency band of 0–33 GHz at a reverse bias voltage less than 4.5 V. These excellent characteristics, such as broad differential phase shift, low insertion loss, and return loss, indicate that the proposed phase shifter can entirely be integrated into a phased array radar circuit.
基金Project supported by Scientific Research Foundation of State Key Laboratory of Power Transmission Equipment & System Security and New Technology (2007DA1051271 2204), Natural Science Foundation of Chongqing Municipality (cstc201 ljjA20009).
文摘This work is carried out to predict the special distribution of electric field induced by multi-circuit intersecting overhead high-voltage (HV) transmission lines (TLs) within a large range without any expensive and time-consuming computation. The two main parts of the presented methodology are 1) setting up a three-dimensional (3D) model to calculate the electric field based on combining ca- tenary equations with charge simulation method and 2) calculating the hybrid electric field excited by multi-circuit intersecting TLs using coordinate transformation and superposition technique. Examples of different TLs configurations, including a 220 kV single-circuit hori- zontally configured TLs, a 500 kV single-circuit triangularly configured TLs and a combination of the 220 kV TLs and the 550 kV TLs, are illustrated to verify the validity of this methodology. A more complicatal configurations, including a 500 kV double-circuit TLs and two 220 kV single-circuit horizontally configured TLs, are also calculated. Conclusions were drawn from the simulation: 1) The presented 3D model outperforms 2D models in describing the electric field distribution generated by practical HV TLs with sag and span. 2) Coordinate trans- formation and superposition technique considerably simplify the electric field computation for multi-circuit TLs configurations, which makes it possible to deal with complex engineering problems. 3) The electric field in the area covered by multiple intersecting overhead TLs is distorted and the hybrid electric field strength in some partial region increases so sharply that it might exceed the admissible value. 4) The configuration parameters of the TLs and the spatial configuration of multi-circuit TLs, for instance, the height of TLs, the length of span and the intersection angle of multiple circuits, influence the strength and the distribution of hybrid electric field. The influence regularities sum- marized in this paper can be referred by future TL designs to meet the electromagnetic environmental protection regulations.
文摘Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode. Finite element design software SAP2000 was used to model the towers and lines. Non-linear dynamic analysis including the large displacement effects was carried out. Macroscopic aspects of wind coherence along element length and integration time step were investigated. An approach is presented to compare the probabilistic dynamic response due to 7 different stochastically simulated wind fields with the response according to EN-50341. The developed model will be used to study the response recorded on a test line due to the actual wind speed time history recorded. It was found that static load from EN overestimated the strength of conductor cables. The response of coupled system considering towers and cables was found to be different from response of only cables with fixed supports.
基金Project supported by the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.61401373)the Research Fund for the Doctoral Program of Southwest University,China(Grant No.SWU111030)
文摘A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed non- linear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) technology. The structure parameters of CRLH NLTLs, e.g. host transmission line, rectangular spiral inductor, and nonlinear capacitor, have a great impact on the second harmonic performance enhancement in terms of second harmonic frequency, output power, and conversion efficiency. It has been experimentally demonstrated that the second harmonic frequency is deter- mined by the anomalous dispersion of CRLH NLTLs and can be significantly improved by effectively adjusting these structure parameters. A good agreement between the measured and simulated second harmonic performances of Ka-band CRLH NLTLs frequency multipliers is successfully achieved, which further validates the design approach of frequency multipliers on CRLH NLTLs and indicates the potentials of CRLH NLTLs in terms of the generation of microwave and millimeter-wave signal source.
文摘During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper presents analytical methods in order to determine the transmission towers potentials during ground faults,for long and short lines.The author developed a global systematic approach to calculate these voltages,which are dependent of a number of factors.Some of the most important factors are:magnitudes of fault currents,fault location with respect to the line terminals,conductor arrangement on the tower and the location of the faulted phase,the ground resistance of the faulted tower,soil resistivity,number,material and size of ground wires.The effects of these factors on the faulted tower voltages have been also examined for different types of power lines.
文摘This article describes the design, modelling and characterization of transmission lines for millimetre wave silicon integrated circuits up to 65 GHz. The simulation results of three different EM (electro-magnetic) simulators for a selected hybrid coplanar layout structure are presented. Two different deembedding methods are investigated and compared with respect to sensitivity to typical measurement errors. Finally both methods are applied to the measurement results of the fabricated test structures in a 250 nm BiCMOS technology showing good agreement to EM simulations and predicted sensitivity to measurement errors.
文摘Anewfault location algorithmfor double-circuit transmissionlines is described inthis paper.Theproposed method uses data extractedfromtwo ends of the transmissionlines andthus eliminates the effects ofthe source impedance andthe fault resistance.The distributed parameter model and the modal transformationare also employed.Depending on modal transformation,the coupled equations of the lines are converted intodecoupled ones.Inthis way,the mutual coupling effects between adjacent circuits of the lines are eliminatedandtherefore an accurate fault location can be achieved.The proposed methodis tested via digital simulationusing EMTP in conjunction with MATLAB.The test results corroborate the high accuracy of the proposedmethod.
基金Research Fund of Chinese State Grid Company (No.SGKJ[2007]413)
文摘A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.
文摘In this article, a transmission line is represented by a cascade of n circuits using a single phase. It is analyzed what is the reasonable number of n circuits and the number of blocks composed by parallel resistor and inductor in parallel for reduction of numerical oscillations. It is simulated the numerical routine with and without the effectof frequency in the longitudinal parameters. Initially, it is used to state variables and 7t circuits representing the transmission line composing a linear system which is solved by numerical routines based on the trapezoidal rule. The effect of frequency on the line is synthesized by resistors and inductors in parallel and this representation is analyzed in details. It is described as transmission lines and the frequency influence in these lines through the state variables.
基金supported by National Natural Science Foundation of China (Nos. 50637010, 51077111)the State Key Laboratory of Electrical Insulation and Power Equipment of Xi'an Jiaotong University of China (EIPE 09207)
文摘Output-pulse shaping capability of a linear transformer driver (LTD) module under different conditions is studied, by conducting the whole circuit model simulation by using the PSPICE code. Results indicate that a higher impedance profile of the internal transmission line would lead to a wider adjustment range for the output current rise time and a narrower adjustment range for the current peak. The number of cavities in series has a positive effect on the output- pulse shaping capability of LTD. Such an improvement in the output-pulse shaping capability can primarily be ascribed to the increment in the axial electric length of LTD. For a triggering time interval longer than the time taken by a pulse to propagate through the length of one cavity, the output parameters of LTD could be improved significantly. The present insulating capability of gas switches and other elements in the LTD cavities may only tolerate a slightly longer deviation in the triggering time interval. It is feasible for the LTD module to reduce the output current rise time, though it is not useful to improve the peak power effectively.